• Title/Summary/Keyword: test power

Search Result 10,130, Processing Time 0.043 seconds

Monte Carlo simulation for verification of nonparametric tests used in final status surveys of MARSSIM at decommissioning of nuclear facilities

  • Sohn, Wook;Hong, Eun-hee
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1664-1675
    • /
    • 2021
  • In order to verify the statistical performance of the nonparametric tests used in the MARSSIM approach, all plausible contamination distribution types that can be encountered in a survey area should be investigated. As the first of such investigations, this study aims to perform the verification for normal distribution of the contamination in a survey area by simulating the collection of random samples from it through the Monte Carlo simulation. The results of the simulations conducted for a total of 81 simulation cases showed that Sign test and WRS test both exhibited an excellent statistical performance: 100% for the former and 98.8% for the latter. Therefore, in final status surveys of the MARSSIM approach, a high statistical performance can be expected in applying the nonparametric hypothesis tests to survey areas whose net contamination can be assumed to be normally distributed.

Development of a Test Facility for Cold-air Performance of Small Axial Turbine (소형 축류터빈의 상온 성능시험기 개발)

  • 손창민;차봉준;이대성
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.7
    • /
    • pp.1780-1786
    • /
    • 1995
  • The main goal of the present study is to establish the techniques and methodolgies of turbine performance test through evaluating the objective turbine test piece, and checking the reliability of the self-developed test facility by performing a series of turbine tests under ambient temperature condition. A high speed coupling, a lubrication system and a test bed of the test facility were modified through a series of preliminary test in order to reduce the vibration and oil leakage. The flowrate control of the test facility and data acquisition were accomplished by using a software called "Labview" The measurement of shaft horse power and control of rotational speed according to the conditions of turbine rotation were performed by a separate system. The preliminary evaluation of the measured data suggests that the developed test facility and the test technique can be used reliably for the performance test of turbines with the minor improvement.provement.

A Study on the Water Absorption Test of Generator Stator Windings Using Probability Distributions (여러 가지 확률분포를 이용한 발전기 고정자 권선의 흡습 시험에 관한 연구)

  • Kim, Hee-Soo;Bae, Y.C.;Kim, Hee-Jeong;Na, Myung-Hwan
    • The Korean Journal of Applied Statistics
    • /
    • v.22 no.5
    • /
    • pp.961-969
    • /
    • 2009
  • Water absorption in water-cooled generator stator windings can cause serious accidents such as insulation breakdown and it brings a generator to the unexpected sudden outage. Accordingly, it is important to diagnose the water absorption of them in the effective operation of power plant. Especially, the capacitance value which is measured for diagnosis is very small so the special diagnosis methods like stochastic theory are needed. KEPRI developed the water absorption test equipment and diagnosis technology for them. In this paper we propose that water absorption test of generator stator windings using probability distributions. The proposed diagnosis technology is applied to the real system and the results of water absorption test for stator windings are agreed to them of water leak test.

Effect of Accommodation Control by Applying Fogging Method in Subjective Refraction and Auto-Refraction in Ametropia (비정시안에서 운무적용에 따른 자각적 및 자동굴절검사의 조절제어효과)

  • Lee, Kang-Cheon;Kim, Sang-Yeob;Cho, Hyun Gug;Yu, Dong-Sik;Moon, Byeong-Yeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.2
    • /
    • pp.119-126
    • /
    • 2016
  • Purpose: To analyze the effect of accommodative control and change values between subjective refraction (SR) and auto-refraction (AR) according to application of fogging after accommodative stimulation depending on ametropia type. Methods: Myopic ametropia 76 eyes and hyperopic ametropia 52 eyes participated for this study. SR and AR values measured by three test conditions (Before accommodative stimulation; Before AS, After accommodative stimulation; After AS, and After application of fogging; After AF) were compared, respectively. Results: In myopic eyes, (-)spherical power by SR and AR in After AS test was significantly increased as compared to Before AS test, (-)spherical power in After AF test was decreased to the level of Before AS test. The differences of spherical power between SR and AR were highly measured by SR in After AS test, and highly measured by AR in After AF test, respectively. In hyperopic eyes, (+)spherical power of SR significantly decreased in After AS test compared to Before AS test, more (+)spherical power was detected in After AF test compared to Before AS test. (+)spherical power of AR have no significant difference between Before AS and After AS test, but more (+)spherical power was detected in After AF test compared to Before AS test. The differences of (+)spherical power between SR and AR were significant in all test conditions. Among 52 eyes which were measured as hyperopic ametropia, 7 eyes were measured as myopia by SR in After AS test. In case of AR, 25 eyes among 52 eyes were mismeasured as myopia of ranges from -0.25 D to -1.25 D in Before AS test, 26 eyes in After AS test, and 19 eyes in After AF test were mismeasured as myopia of ranges from -0.25 D to -1.25 D. Conclusions: Regardless of ametropia type, accommodative control by After AF test was effective on both refraction process. However, in auto-refraction for hyperopic eyes, the misdetermined proportion of refractive error's type was high due to consistent accommodative intervention in all test condition. Therefore, in order to obtain an accurate value of refractive errors, full correction should be determined by subjective refraction process after fogging method.

Simulation analysis of type I error and power for F test and rank transformed F test in $2 times 2$ factorial ANOVA ($2 times 2$ 요인 계획법의 F 검정과 순위 F 검정에 따른 제1종 오류와 검정력 분석에 대한 의태 연구)

  • 최영훈
    • The Korean Journal of Applied Statistics
    • /
    • v.8 no.2
    • /
    • pp.87-97
    • /
    • 1995
  • When there is no main effcts or only one main effect in a $2 \times 2$ factorial design, Type I error rates and power for the rank transformed F test (FR test) for interaction are nearly equal to those of the classical F test. However the power of FR test is quite superior under the exponential distribution rather than the of FR test is quite superior under the exponential distribution rather than the normal distribution. Meanwhile when both main effects are in the model, Type I error rates of FR test, compared with those of F test, decrease as the effect size increases and are dependent on the fashion in which main effects are constructed. In addition, the power of FR test increases as the effect size and the sample size increase and is highly dependent on the manner in which main effects are constructed and the type of population distribution.

  • PDF

Power Test of Trend Analysis using Simulation Experiment (모의실험을 이용한 경향성 분석기법의 검정력 평가)

  • Ryu, Yongjun;Shin, Hongjoon;Kim, Sooyoung;Heo, Jun-Haeng
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.3
    • /
    • pp.219-227
    • /
    • 2013
  • Time series data including change, jump, trend and periodicity generally have nonstationarity. Especially, various methods have been proposed to identify the trend about hydrological time series data. However, among various methods, evaluation about capability of each trend test has not been done a lot. Even for the same data, each method may show the different result. In this study, the simulation was performed for identification about the changes in trend analysis according to the statistical characteristics and the capability in the trend analysis. For this purpose, power test for the trend analysis is conducted using Men-Kendall test, Hotelling-Pabst test, t test and Sen test according to the slope, sample size, standard deviation and significance level. As a result, t test has higher statistical power than the others, while Mann-Kendall, Hotelling-Pabst, and Sen tests were similar results.

The Field Test of Power Performance Measurement for U50 Wind Turbine (U50 풍력발전기 출력성능 실증연구)

  • Hwang, Jin-Su;Jang, Seong-Tae;Kim, Dae-Hyun;Bang, Jo-Hyug;Ryu, Ji-Yune
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.372-375
    • /
    • 2007
  • 750kW gearless type wind turbine, named U50, is developed by UNISON in Korea. The newly developed wind turbine should be evaluated the power curve and the estimated annual energy production by following international standard to verify the power performance characteristics. This paper shows the test and evaluation procedure according to IEC 61400-12-1 which specifies a procedure of measuring the power performance characteristics of a single wind turbine and applies to the testing of wind turbines of all types and sized connected to the electrical power network. And this paper also shows the power performance characteristics for U50 wind turbine which is determined in accordance with IEC regulation.

  • PDF

Soil Breakdown Test using Fixture (Fixture를 이용한 토양 절연파괴 실험)

  • Lee, H.G.;Ha, T.H.;Jung, D.H.;Ha, Y.C.;Kim, D.K.;Bae, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.384-385
    • /
    • 2007
  • The fault current through the earth originated from a power line ground fault might cause arcing through the soil to an adjacent pipeline, which might bring about not only a catastrophic accident such as gas explosion and oil leakage but also a hazard to the safety of workers responsible for the maintenance and repair of the pipeline. In this paper we experimented on the soil breakdown test using the fixture and outlined the standards for the separation distance of a buried pipeline adjacent to the power line tower.

  • PDF

An Efficient Test Data Compression/Decompression for Low Power Testing (저전력 테스트를 고려한 효율적인 테스트 데이터 압축 방법)

  • Chun Sunghoon;Im Jung-Bin;Kim Gun-Bae;An Jin-Ho;Kang Sungho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.2 s.332
    • /
    • pp.73-82
    • /
    • 2005
  • Test data volume and power consumption for scan vectors are two major problems in system-on-a-chip testing. Therefore, this paper proposes a new test data compression/decompression method for low power testing. The method is based on analyzing the factors that influence test parameters: compression ratio, power reduction and hardware overhead. To improve the compression ratio and the power reduction ratio, the proposed method is based on Modified Statistical Coding (MSC), Input Reduction (IR) scheme and the algorithms of reordering scan flip-flops and reordering test pattern sequence in a preprocessing step. Unlike previous approaches using the CSR architecture, the proposed method is to compress original test data, not $T_{diff}$, and decompress the compressed test data without the CSR architecture. Therefore, the proposed method leads to better compression ratio with lower hardware overhead and lower power consumption than previous works. An experimental comparison on ISCAS '89 benchmark circuits validates the proposed method.

Study of Selection Plan of Circuit breakers, Cables and Modeling of Korean Low Voltage Electrical Installation integration Test Site based on IEC 60364 (IEC 60364 기반의 한국형 저압전기설비 통합 실증단지 모델링 및 차단기와 케이블의 선정 방안 고찰)

  • Kim, Doo-Ung;Ryu, Kyu-Sang;Kim, Han-Soo;Shin, Dae-Sung;Ryu, Ki-Hwan;Kim, Chul-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.59-64
    • /
    • 2015
  • IEC is an international standards which are used in many countries with Europe as the center. IEC standard is introduced in Korea according to WTO/TBT agreements, however until now there are no buildings in Korea which are designed applying IEC standard. Therefore, KEA(Korea Electric Association) is scheduled to construct Korean low voltage electrical installation integration test site which is designed applying IEC standard. In this paper, before being under construction of Korean low voltage electrical installation integration test site, power substation is modeled based on real design parameters and method to select circuit breakers and cables is presented applying IEC standard in the modeled power substation. EMTP(ElctroMagnetic Transient Program) is used for simulation program. EMTP which is power system analysis program is easy to model power system and power substation.