• 제목/요약/키워드: test power

검색결과 10,130건 처리시간 0.033초

차수형 케이블의 수트리 가속실험후 와이블분포 해석 (The Analysis of Weibull Distribution after an Accelerated Aging Test of MV Cable)

  • 김진국;임장섭;송일관;이재봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.178-181
    • /
    • 2003
  • For many years, testing laboratories, research institutes and manufactures try to find a reliable water tree accelerated ageing test that is able to show whether a polymer Medium Voltage cable os susceptible to water treeing or not. Test on laboratory samples, model cable designs, and fell size cable are presented Apart form aging, another important aspect of any accelerated aging test is the right choice of th preconditioning method. This paper is the analysis of weibull distribution method after an accelerated aging test of MV(Medium Voltage) cable.

  • PDF

수력발전소 자동제어설비 시험용 신호변환장치 개발에 관한 연구 (A Study on Development of Signal Conditioner for Test of Automatic Control Equipments in Hydro Power Plant)

  • 변두균;장문성;김주현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.169-171
    • /
    • 1995
  • Automatic control equipment in hydro power plant, such as turbine governor or automatic voltage regulator have to act promptly against for variation of power system, so it is necessary to check and test continuously. During last five years, the performance test of automatic control equipment was performed about 20 units of hydro turbine generator. In this process, because it has complex connection and before calibration, signal conditioner was developed as an auxiliary equipment for performance test. It includes function of signal amplifier, transducer, and meters. As a result of use this equipment for electric governor test at soyang-gang hydro power plant, it was possible to find output data equal to old one.

  • PDF

Tracking wheel 시험을 통한 배전용 폴리머애자 열화특성 평가 (Evaluation of Ageing Characteristics of Polymeric Insulators for Distribution Lines by Tracking Wheel Test)

  • 이병성;한재홍;한용희;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2314-2316
    • /
    • 1999
  • This study describes the results of aging characteristics of polymer insulators through the tracking wheel test. In order to evaluate the reliability of polymer insulators, 4 polymer insulators which used in the field were selected. Electrical tests such as power frequency voltage test, steep-front impulse voltage test were performed after tracking wheel test. Chemical structure and contact angle were measured for investigating an aging characteristics. Although some changes have occurred on the surface of insulator, there are no critical changes between new and tracking wheel tested insulator.

  • PDF

고분자(高分子) 장간애자용(長幹碍子用) 옥외(屋外)시험장(試驗場) 구축(構築) (Field Test Facilities for Composite Long Rod Insulator)

  • 한기만;김동욱;권혁삼;유성종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1499-1501
    • /
    • 1994
  • This paper studies on the outdoor field test facilities which are established for weather-resist and mechanical-resist property teat of composite insulator. We have established measuring and data acquisition system for various test conditions -leakage current, temperature, humidity, wind direction, wind velocity and rainfall. The merry-go-round test and salt fog test have been studied in order to evaluate non tracking property of rubber material. Especially we have checked the relationship between hydrophobicity and outdoor exposure degree by contact angle measurement.

  • PDF

22.9kV 트리억제형 전력케이블의 성능평가 (Efficiency appraisal of 22.9kV tree retardant power cable)

  • 김위영;윤대혁;박태곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.179-182
    • /
    • 2002
  • XLPE compound have used for insulation of 22.9(kV) power cable. But tree retardant power cable has developed and is going to br used commonly. TR XLPE compound retard production and growth of water tree. In this paper, tensile strength, elongation at break, degree of crosslinking, lightning impulse test, AC breakdown test, cyclic aging for 14days and accelerated water treeing test of TR XLPE insulated power cable were examined according to the KEPCO buying spec. & AEIC CS 5-94 standards. before and after As the result, tensile strength, elongation at break and degree of crosslinking test results of TR XLPE insulation were higher than requirement values. After accelerated water treeing test for 120 days, 240 days and 360 days, AC breakdown voltages were not decreased for accelerated water treeing aging duration

  • PDF

MMC 기반 HVDC 시스템용 서브모듈 시험회로의 커패시터 용량 분석 (Capacitance Value Analysis of Sub-module Test Circuit for MMC-based HVDC System)

  • 서병준;박권식;조광래;노의철;김흥근;전태원;김태진;이종필
    • 전력전자학회논문지
    • /
    • 제23권6호
    • /
    • pp.433-439
    • /
    • 2018
  • This study considers the design of a submodule test circuit for the modular multi-level converter (MMC)-based HVDC systems. A novel submodule test circuit is proposed to provide not only an AC but also a DC component to the submodule current. However, the current waveforms depend on the capacitor voltages. Therefore, determining the capacitance value of the test circuit is important. Finding a proper capacitance value is easy when the proposed analysis method is used. Simulation and experimental results show the usefulness of the proposed method.

Low Power Scan Chain Reordering Method with Limited Routing Congestion for Code-based Test Data Compression

  • Kim, Dooyoung;Ansari, M. Adil;Jung, Jihun;Park, Sungju
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권5호
    • /
    • pp.582-594
    • /
    • 2016
  • Various test data compression techniques have been developed to reduce the test costs of system-on-a-chips. In this paper, a scan chain reordering algorithm for code-based test data compression techniques is proposed. Scan cells within an acceptable relocation distance are ranked to reduce the number of conflicts in all test patterns and rearranged by a positioning algorithm to minimize the routing overhead. The proposed method is demonstrated on ISCAS '89 benchmark circuits with their physical layout by using a 180 nm CMOS process library. Significant improvements are observed in compression ratio and test power consumption with minor routing overhead.

RTDS 시험모듈을 이용한 태양광 인버터의 성능시험에 관한 연구 (A Study on Performance Test of a Photovoltaic System Inverter using Real Time Digital Simulator (RTDS))

  • 김응상;김슬기;전진홍;안종보
    • 전기학회논문지
    • /
    • 제56권2호
    • /
    • pp.325-333
    • /
    • 2007
  • A PV system inverter test module using RTDS was developed and performance test of a commercial PV inverter was carried out. The developed module consists of one RTDS hardware rack, RTDS software models representing PV array and simple distribution system, and two power amplifiers that was specifically designed for generating power corresponding to signals from RTDS. Performance test results verified effectiveness and reliability of the test module. It is expected that the developed test module may help PV inverter manufacturers improve ana test their systems in the developing stage.

반도체 테스트 비용 절감을 위한 랜덤 테스트 효율성 향상 기법 (A Method on Improving the Efficiency of Random Testing for VLSI Test Cost Reduction)

  • 이성제;이상석;안진호
    • 반도체디스플레이기술학회지
    • /
    • 제22권1호
    • /
    • pp.49-53
    • /
    • 2023
  • In this paper, we propose an antirandom pattern-based test method considering power consumption to compensate for the problem that the fault coverage through random test decreases or the test time increases significantly when the DUT circuit structure is complex or large. In the proposed method, a group unit test pattern generation process and rearrangement process are added to improve the problems of long calculation time and high-power consumption, which are disadvantages of the previous antirandom test.

  • PDF

석탄화력발전소 보일러 노내압력 제어알고리즘과 분산제어시스템의 개발 (The Development of Boiler Furnace Pressure Control Algorithm and Distributed Control System for Coal-Fired Power Plant)

  • 임건표;허광범;박두용;이흥호
    • 전기학회논문지P
    • /
    • 제62권3호
    • /
    • pp.117-126
    • /
    • 2013
  • This paper is written for the development and application of boiler furnace pressure control algorithm and distributed control system of coal-fired power plant by the steps of design, coding, simulation test, site installation and site commissioning test. The control algorithms were designed in the shape of cascade control for two parts of furnace pressure control and induced draft fan pitch blade by standard function blocks. This control algorithms were coded to the control programs of distributed control systems. The simulator for coal-fired power plant was used in the test step and automatic control, sequence control and emergency stop tests were performed successfully like the tests of the actual power plant. The reliability was obtained enough to be installed at the actual power plant and all of distributed control systems had been installed at power plant and all signals were connected mutually. Tests for reliability and safety of plant operation were completed successfully and power plant is being operated commercially. It is expected that the project result will contribute to the safe operation of domestic new and retrofit power plants, the self-reliance of coal-fired power plant control technique and overseas business for power plant.