• 제목/요약/키워드: test circuit

검색결과 1,833건 처리시간 0.036초

부스바(Busbar)형 전기접점의 단락통전성능 해석기법 개발 (Development of the Analysis Technology for Short Circuit Current Capability of Busbar-Type Electrical Contacts)

  • 오연호;송기동;김진기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권1호
    • /
    • pp.27-32
    • /
    • 2005
  • This study presents an analysis technique that can consider all variables which are needed in the design of short circuit current capability of electrical contacts. Required variables in the design are material of contact, contacting area, applied force, asperity of surface, current and so on. Short circuit current capability test was carried out for the interrelation of design variables and the verification of analysis technique. Temperature rise equation of the contacts was obtained from the test results, and also, a standard that is criterion of the occurrence availability of melting or spot of contact surface from test results was established.

BiCMOS 회로의 고장 검출을 위한 테스트 패턴 생성 (Test Pattern Generation for Detection of faults in BiCMOS Circuits)

  • 신재흥;이병효;김일남;이복용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.113-116
    • /
    • 2003
  • BiCMOS circuit consist of CMOS part which constructs logic function, and bipolar part which drives output load. In this paper, proposes a method for efficiently generating test pattern which detect faults in BiCMOS circuits. In proposed method, BiCMOS circuit is divided into pull-up part and pull-down part, using structural property of BiCMOS circuit, and we generate test pattern using set theory for efficiently detecting faults which occured each divided blocks.

  • PDF

BiCMOS 회로의Stuck-Open 고장과 Stuck-On 고장 검출을 위한 테스트 패턴 생성 (Test Pattern Genration for Detection of Stuck-Open and Stuck-On Faults in BiCMOS Circuits)

  • 신재흥;임인칠
    • 전자공학회논문지C
    • /
    • 제34C권1호
    • /
    • pp.1-11
    • /
    • 1997
  • A BiCMOS circuit consists of the CMOS part which performs the logic function, and the bipolar part which drives output load. In BiCMOS circuits, transistor stuck-open faults exhibit delay faults in addition to sequential beavior. Also, stuck-on faults enhanced IDDQ (quiscent power supply current) at steady state. In this paper, a method is proposed which efficiently generates test patterns to detect stuck-open faults and stuck-on faults in BiCMOS circuits. The proposed method divides the BiCMOS circuit into pull-up part and pull-down part, and generates test patterns detect faults occured in each part by structural property of the BiCMOS circuit.

  • PDF

전력설비 시험시 인적실수 방지를 위한 345kV 모선보호 배전반 회로개선 (Circuit Improvement of 345kV Bus bar protection panel for Human Error Prevention in the event of Field Test)

  • 김인섭;이종석;정시환;강대언;승재현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.675-676
    • /
    • 2007
  • This Paper presents circuit improvement of 345kV Bus bar protection panel by using VDD (Voltage disturbance detection) relay with distinctive ability between human error in the field test and real facility faults. Therefore, We expect that this improvement of circuit helps decrease of blackout coming from human error. In order to guarantee electric power system reliability, consistent study of human error prevention in the event of field test is necessarily required

  • PDF

다목적 수동형 라돈농도 측정기 개발 (Development of A Multipurpose Passive Type Radon Monitor)

  • 이봉재;박영웅
    • 동위원소회보
    • /
    • 제21권4호
    • /
    • pp.55-65
    • /
    • 2006
  • A passive type radon monitor adopting two silicon PIN detector as radiation detector has been developed, manufactured and test-evaluated. A radiation signal processing circuit has been electronically tested and then the radiation detection characteristics of this instrument has been performance-tested by using reference radon concentration and a reference photon radiation field. As a result, in a electronic performance test, radiation signals from each detector were well observed in each signal processing circuit. The radiation detection sensitivity of this instrument after several test-irradiations to a Cs-137 gamma radiation source and a standard radon concentration appeared to be 1.37 cph/$\mu$Svh-1 and 1.66 pCi/L respectively. The developed radon monitor in this paper could be used conveniently in monitoring of radon concentration in buildings which population utilize in Korea.

  • PDF

Influence of SF6/N2 Gas Mixture Ratios on the Lightning Streamer Propagation Characteristics of 22 kV MV Circuit Breaker

  • Gandhi, R.;Chandrasekar, S.;Nagarajan, C.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1663-1672
    • /
    • 2018
  • In recent times, gas insulated medium voltage (MV) circuit breakers (CB) form a vital component in power system network, considering its advantages such as reduced size and safety margins. Gas insulation characteristics of circuit breakers are generally measured by lightning impulse (LI) test according to IEC standard 60060-1 as a factory routine test. Considering the environmental issues of $SF_6$ gas, many research works are being carried out towards the mixture of $SF_6$ gases for high voltage insulation applications. However, few reports are only available regarding the LI withstand and streamer propagation characteristics (at both positive and negative polarity of waveform) of $SF_6/N_2$ gas mixture insulated medium voltage circuit breakers. In this paper, positive and negative polarity LI tests are carried out on 22 kV medium voltage circuit breaker filled with $SF_6/N_2$ gas mixture at different gas pressures (1-5 bar) and at different gas mixture ratios. Important LI parameters such as breakdown voltage, streamer velocity, time to breakdown and acceleration voltage are evaluated with IEC standard LI ($1.2/50{\mu}s$) waveform. Weibull distribution analysis of LI breakdown voltage data is carried out and 50% probability breakdown voltage, scale parameter and shape parameter are evaluated. Results illustrate that the $25%SF_6+75%N_2$ gas filled insulation considerably enhances the LI withstand and breakdown strength of MV circuit breakers. LI breakdown voltage of circuit breaker under negative polarity shows higher value when compared with positive polarity. Results show that maintaining the gas pressure at 0.3 MPa (3 bar) with 10% $SF_6$ gas mixed with 90% $N_2$ will give optimum lighting impulse withstand performance of 22 kV MV circuit breaker.

근거리선로고장시험의 실제시험상태를 고려한 인공선로 파라미터 조정 (Parameter Tuning of Artificial Lines for SLF tests on Circuit Breakers Considering Stray Capacitances of Testing and Measuring Equipment)

  • 이용한;류형기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.544-547
    • /
    • 2002
  • In a high power laboratory, artificial lines are used for SLF tests of circuit breakers. The line side PTRV is affected by the stray capacitances of testing and measuring equipment as well as the circuit parameters of artificial lines. The changing pattern of PTRV was examined, and the circuit parameters of artificial line for some examples were compensated using the changing pattern to satisfy test conditions specified.

  • PDF

순환식 과제 지향 운동이 경증치매환자의 균형능력과 인지기능에 미치는 영향 (The Effects of Task Oriented Circuit Exercise on Balance and Cognition in Mild Dementia Patients)

  • 정은지;김원복
    • 대한물리의학회지
    • /
    • 제9권1호
    • /
    • pp.83-91
    • /
    • 2014
  • PURPOSE: The purpose of this study was to investigate the effects of task oriented circuit exercise(TOCE) on the balance and cognition in mild dementia patients. METHODS: The subjects of the study were 30 patients with mild dementia and assigned to the TOCE(task oriented circuit exercise) group(n=15) and aerobic exercise(AE) group(n=15). TOCE group performed six task three times weekly for 12 weeks. AE group underwent the cycle ergometer and treadmill exercise three times a week during the experimental period respectively. Timed up and go test(TUG), Berg balance scale(BBS) and AP1153 Biorescue were used to assess the parameters for the balance. Korean-mini mental state examination and Global deterioration scale(GDS) were used to assess the parameters for the cognition. For the statistical analysis, paired t-test and independent t-test were used to compare the differences among two groups. RESULTS: Each group showed improvement in balance and possibility for improving cognitive function. TOCE group especially, there were significant improvements in limit of stability. CONCLUSION: The results of the study suggest that TOCE is a more diverse exercise programs introduced in the study. Furthermore, TOCE can be a helpful to improve the balance and cognition in mild dementia patients.

초고압 $SF_6$ 가스 차단기의 실험적 차단성능 평가 (Performance Evaluation of a $SF_6$ Gas Circuit Breaker with Experimental Investigation)

  • 정영우;박홍태;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.96-99
    • /
    • 2005
  • In this study, we build system and techniques of evaluating the interruption performance of the GCB with experimental method. We constructed a simplified synthetic test circuit of which ability is up to 245kV, 50kA BTF test. And We composed a model test circuit breaker with puffer assisted self blasting type GCB. With this circuit breaker, we carried out the experiment of no load and SLF90. During the tests, we measured the several factors such as stroke, pressure, arc temperature, the voltage and current near the current zero and dI/dt, dV/dt. Arc conductivity before 200ns before current zero which is one of the indexes of the thermal recovery of a GCB was measured. With these kinds of measurement, we could estimate the performance of a GCB fundamentally. Futhermore these results were used to adjust the arc modeling with CFD(computational fluid dynamics) and we could increase the plausibility of the analytical method.

  • PDF