Influence of Manufacturing Conditions on the Reflectance and Life Time of the Gold Protected IR Mirror (금 증착 적외선 반사판의 반사율 및 수명에 미치는 제조공정 변수의 영향)

  • Choi, Yong-Sun;Lee, Young-Ki;Lee, You-Kee
    • Korean Journal of Materials Research
    • /
    • v.28 no.4
    • /
    • pp.201-207
    • /
    • 2018
  • Infrared(IR) heating has many advantages, such as energy efficiency, reduced heating time, cleanliness, equipment compactness, high drying rate and easy automation. These features of IR heating provide widely industrial applications, such as surface heat treatment in semiconductor fabrication, thermoforming of polymers, drying and disinfection of food products, heating to metal forging, and drying of wet materials. In this study, the characteristics of a protected gold mirror were examined by spectrophotometer and the lifetime of the coating layers were evaluated by a cross-cutting method and salt spray test. The effects of manufacturing conditions on the protected gold mirror were seen and remedies for these effects were noted in order to improve the properties of the protected gold mirror in the drying process. The reflectance and lifetime of the protected gold mirror was influenced by manufacturing conditions, such as surface roughness and forming conditions of the anti-oxide layer, the adhesion layer, the reflecting layer and the protection layer. The results of this study showed that the protected gold mirror manufactured using a buffing method for pre-treatment resulted in the most effective reflectance. In addition, $Al_2O_3$ coating on an Al substrate as an anti-oxide layer was more effective than the anodizing process in the test of reflectance. Furthermore, the protected gold mirror manufactured by layers forming of various materials resulted in the most effective reflectance and lifetime when coated with $Al_2O_3$ as the anti-oxide layer, coated Cr as the adhesion layer, and coated $MgF_2$ as the protection layer.

Development of Low-Cost Automatic Flight Control System for an Unmanned Target Drone (무인표적기용 저가형 자동비행시스템 개발)

  • Lee, Jang-Ho;Ryu, Hyeok;Kim, Jae-Eun;Ahn, Iee-Ki
    • Journal of Advanced Navigation Technology
    • /
    • v.8 no.1
    • /
    • pp.19-26
    • /
    • 2004
  • This paper deals with the automatic flight control system for an unmanned target drone which is operated by an army as an anti-air gun shooting training. By automation of unmanned target drone that is manually operated by external pilot, pilot can reduce workload and an army can reduce the budget. Most UAVs which are developed until today use high-cost sensors as AHRS and IMU to measure the attitude, but those are contradictory for the reduction of budget. This paper says the development of low-cost automatic flight control system which makes possible of automatic flight with low-cost sensors. We have developed the integrated automatic flight control system by integrating electricity module, switching module, monitoring module and RC receiver as an one module. We also prove the performance of automatic flight control system by flight test.

  • PDF

Technology and Market Trend Analysis of the Laser Slide Marking System (레이저 슬라이드 마킹 시스템의 기술 및 시장동향 분석)

  • Kwon, young-il
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2007.11a
    • /
    • pp.457-461
    • /
    • 2007
  • Laser slide marking systems are being considered by the staffs of clinical laboratories in hospitals as the main potential substituent for the conventional manual processes of the laboratory works. Many of the processes in domestic hospitals such as operations of test equipments in clinical laboratories and physical distributions in hospitals are being computerized due to the recent development of information technologies. The clinical laboratories in charge of inspection processes are putting their efforts on the computerization and automation of the test equipments, which increases the demand for the usage of laser marking slide systems which is the main component of the inspection works. The domestic market size of the laser slide marking systems is expected to be 250 million won in 2008, which is believed to increase to 1.75 billion won in 2012. The laser slide marking system was first introduced to domestic hospitals in 2005. It's product life cycle is currently on the early stage, and it is believed to have a very high growth potential in the future.

  • PDF

An Analysis of the Effect of Government Support on Automation and Smart Factory (자동화 및 스마트 공장 구축에 대한 정부 지원사업의 효과 분석)

  • Kang, Jung-Seok;Cho, Keun-Tae
    • Journal of Korea Technology Innovation Society
    • /
    • v.21 no.2
    • /
    • pp.738-766
    • /
    • 2018
  • The purpose of this paper is to figures out the impact on the business performance based on the case studies about the establishment of automated smart factories supported by the government. In this study, the effectiveness of supporting business is verified by comparing supported company with non-supported ones using methods such as T-test and ANOVA. The PSM method was used to solve the selection bias issue between the experimental group and the controlled group. The research results have shown that the effect of the supporting business to the automated system was tenuous, and the amount of sales and research and development costs was increased after a certain schedule passed in case of the supporting project to the smart factory. There is some time lag to appear the effect of the government supporting businesses and the supporting business to the automated system leads to long term sales increase by increasing parameters like research and development costs rather than direct influence. Therefore, this research will be useful information for the process of establishing useful basic data and policies which helps to secure new budget Government Supporting Businesses and find ways improve the business.

Effect on Flow Boiling Heat Transfer of Minichannel Diameter for R-410A (R-410A 비등열전달에 미치는 미세관경의 영향)

  • Choi, Kwang-Il;Pamitran, A.S.;Oh, Jong-Taek;Hrnjak, Pega;Park, Chang-Yong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.12
    • /
    • pp.663-670
    • /
    • 2009
  • Two-phase flow boiling heat transfer of R-410A in horizontal small tubes was reported in the present experimental study. The local heat transfer coefficients were obtained over a heat flux range of 5 to 40 kW/$m^2$ a mass flux range of 170 to 600 kg/$m^2s$, a saturation temperature range of 3 to $10^{\circ}C$, and quality up to 1.0. The test section was made of stainless steel tubes with inner diameters of 0.5 and 3.0 mm, and lengths of 330 and 3000 mm, respectively. The test section was heated uniformly by applying a direct electric current to the tubes. The effects on heat transfer of mass flux, heat flux, inner tube diameter, and saturation temperature were presented. The experimental heat transfer coefficients are compared with six existing heat transfer coefficient correlations. A new boiling heat transfer coefficients correlation based on the superposition model for R-410A in small tubes was developed with mean deviation of 10.13%.

A Study on the EMS Analysis of Image Variations for EUT (EUT의 영상변화에 의한 EMS 해석에 관한 연구)

  • Yun, Ki-Bang;Lee, Chang-Bok;Jung, Ki-Beom;Kim, Ki-Doo
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.2
    • /
    • pp.76-83
    • /
    • 2002
  • In this paper, we developed the real-time automation program for the immunity test according to the determination of the EUT image, and analyzed the image of standard PC monitor and the monitor image affected by the electromagnetic field. The image change detection algorithm was realized for the real-time determination of the malfunction, and we attempted to obtain the consistent results for the electromagnetic immunity measurement. We showed the possibility to determine the immunity of the PC monitor and other equipment by performing the image change detection of EUT, and the experimental results for the EUT immunity determination of EMS (Electro-Magnetic Susceptibility, IEC 61000-4-3) are also proposed in line with the international standard and domestic trends. 

A Performance Test for Assessment of the RFID/USN Inter-working System's Applicability to the Construction Industry (RFID/USN 연동 시스템의 건설 산업 적용을 위한 성능 실험에 관한 연구)

  • Yoo, Ji-Yeon;Choi, Nu-Ri;Kim, Chang-Wan;Kim, Hyoung-Kwan;Han, Seung-Heon;Kim, Moon-Kyum
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.880-885
    • /
    • 2007
  • In the last decades, the resource used in the construction process has become much more various in kinds and increased in number as construction has become enlargement and complexity. Resource management on a construction site has been recognized as a detrimental factor to influence project success, therefore various technologies have been applied by the construction industry to streamline resource management. RFID/USN interworking system composed of RFID technology and sensor network supports automation of resource management and real-time information networking. Most of research efforts for RFID technology in the construction industry have been limited to object identification technology. The study proposed herein it to verify the applicability of RFID/USN interworking system to the construction industry. The identification rates of RFID/USN interworking system by distance and degree and by type of materials was identified and analyzed.

  • PDF

Rotating Arm Test for Assessment of an Underwater Hybrid Navigation System for a Semi-Autonomous Underwater Vehicle (반자율무인잠수정의 수중 복합항법 시스템 성능평가를 위한 회전팔 시험)

  • Lee, Chong-Moo;Lee, Pan-Mook;Kim, Sea-Moon;Hong, Seok-Won;Seo, Jae-Won;Seong, Woo-Jae
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.141-148
    • /
    • 2003
  • This paper presents a rotating ann test for assessment of an underwater hybrid navigation system for a semi-autonomous underwater vehicle. The navigation system consists of an inertial measurement unit (IMU), an ultra-short baseline (USBL) acoustic navigation sensor and a doppler velocity log (DVL) accompanying a magnetic compass. The errors of inertial measurement units increase with time due to the bias errors of gyros and accelerometers. A navigational system model is derived to include the error model of the USBL acoustic navigation sensor and the scale effect and bias errors of the DVL, of which the state equation composed of the navigation states and sensor parameters is 25 in the order. The conventional extended Kalman filter was used to propagate the error covariance, update the measurement errors and correct the state equation when the measurements are available. The rotating ann tests are conducted in the Ocean Engineering Basin of KRISO, KORDI to generate circular motion in laboratory, where the USBL system was absent in the basin. The hybrid underwater navigation system shows good tracking performance against the circular planar motion. Additionally this paper checked the effects of the sampling ratio of the navigation system and the possibility of the dead reckoning with the DVL and the magnetic compass to estimate the position of the vehicle.

  • PDF

A Study on the Test Method of Local Information Processing Device in Digital Substation Based on IEC 61850 (IEC 61850 기반 디지털변전소 현장정보처리장치 시험 방법에 관한 연구)

  • Kim, Nam-Dae;Kim, Woo-Jung;Lee, Nam-Ho;Kim, Seok-Kon;Jang, Byung-Tae
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.3
    • /
    • pp.253-257
    • /
    • 2020
  • The local information processing devices are devices that process information by converting voltage, current, and digital electric signals from legacy-type power facility into IEC 61850 based data. It acquires and processes the operation information of legacy-type power facility, performs control of power facility, and interlock function using internal logic. In particular, the time to convert data to process input and output information for a device is important because a number of protection relay input and output signals are handled by only one device. This paper introduces test methods and cases for measuring IEC 61850 communication function and input/output data conversion time of local information processing device.

A Study on the Facility and Equipment of Laboratory Medicine in General Hospital - Focused on more than 550 bed sized hospitals (종합병원 진단검사의학과 검사실의 시설 설비 현황 조사 - 550 병상 이상 종합병원을 중심으로)

  • Kim, Youngaee;Song, Sanghoon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.26 no.1
    • /
    • pp.73-84
    • /
    • 2020
  • Purpose: Though Korean healthcare services have been upgraded, infection and fire had been broken out in general hospitals. And higher concerns about quality assessment made it to clinical laboratory design guideline studies. So, this study investigates the facilities, equipment and personnel of laboratory medicine focusing on more than five hundred fifty bed hospital, and contributes to make guidelines for safety and efficiency in lab. Methods: Questionnaires to supervisor technologist and field surveys to medical laboratories in korean hospitals have been conducted for the data collection. 16 answers have been analysed statistically by MS Excel program. Results: Most of the sample tests such as hematology, clinical chemistry, immunology, transfusion, urinalysis, microbiology and molecular diagnosis are performed by more than 80% in large sized general hospital laboratory. In the test methods, automatic analyzers are used up to 80%, total laboratory automation up to 43% in clinical chemistry and immunology, and manual tests in all sorts of the test. There are placed in single lab or two and three labs above the ground, which are all in semi-open lab. There is some correlation with the number of specimens and the number of lab people depending on the number of hospital beds. Laboratory environment shows that work distance is good, but evacuation path width, visibility, separation of staff area from automatic analyzer, and equipment installations are needed to have more spaces and gears. Most of the infection controls are equipped with mechanical ventilation, air-conditioning, washbasin and wastewater separation, BSC installation and negative pressure lab room. Implications: Although the laboratory space area is calculated considering the number of hospital beds, type of tests and number of staff, hospital's expertise and the samples numbers per year should be taken into account in the planning of the hospital.