• 제목/요약/키워드: temperature stable characteristics

검색결과 961건 처리시간 0.029초

증발기 과열도제어에 따른 냉동장치의 동특성에 관한 연구 (A Study on Dynamic Characteristics of a Refrigeration System by Controlling the Evaporator Superheat)

  • 김재돌;오후규;윤정인
    • 대한기계학회논문집
    • /
    • 제19권8호
    • /
    • pp.2012-2021
    • /
    • 1995
  • An experimental study was performed for the analysis of dynamic characteristics of refrigeration system by controlling the evaporator superheat. Experimental data have been taken utilizing two different devices, thermostatic expansion valve(T.E.V.) and electronic expansion valve(E.E.V.), for the control of the evaporator superheat. The ranges of parameters, such as superheat, mass flow rate of refrigerant and inlet temperature of evaporator were 5-30.deg. C 90-170 kg/h and 10-25.deg. C, respectively. The data taken from the T.E.v.and E.E.v.were discussed with the control of the superheat, pressure drop, refrigerating capacity, compression work, evaporating temperature, condensing temperature and COP affecting performance characteristics of refrigeration system. In case of the refrigerant flow control with T.E..V., the superheat and pressure drop of the evaporator varied periodically, but the control with E.E.V., the parameters were very stable. In E.E.v.control, refrigerating capacity, compression work and evaporating temperature were decreased with increasing superheat, and the highest COP was obtained in the range of superheat from 5.deg. C to 15.deg. C.

감습 고분자막이 코팅된 수정미소저울 습도센서 제작 및 특성연구 (Development of a hygroscopic polymer-coated QCM humidity sensor and its characteristics)

  • 권수용;김종철;최병일;남현수
    • 센서학회지
    • /
    • 제14권6호
    • /
    • pp.395-401
    • /
    • 2005
  • A highly stable quartz crystal microbalance (QCM) that showed a stability of frequencies and exhibited a very low noise level has been developed. The long-term drift was <0.05 Hz/h over a period of 10 h, and the short-term rms (root mean square) noise was <0.015 Hz. Our QCM sensor was used as a humidity sensor employing a poly(methyl methacrylate) (PMMA) polymer film as a hygroscopic layer, which showed good characteristics in the relative humidity (RH) range of $2{\sim}90%$ RH. Comparing the characteristics of the QCM sensor with those of other types of humidity sensors employing PMMA film as a hygroscopic layer, and with other QCM sensors employing other hygroscopic layers is represented.

이어도 종합해양과학기지에서 관측된 난류 플럭스의 계절적 특성 (Seasonal Characteristics of Turbulent Fluxes Observed at leodo Ocean Research Station)

  • 오현미;하경자;심재설;현유경;윤경숙
    • 대기
    • /
    • 제17권4호
    • /
    • pp.421-433
    • /
    • 2007
  • We have investigated the seasonal characteristics of surface turbulent fluxes observed at Ieodo Ocean Research Station from 2005 to 2006. Both 10Hz and 30 minutes flux data are quality controled, and tilt correction is performed in 10Hz data before quality control. The turbulent fluxes of open sea shows clear seasonal variations, though diurnal variations are barely shown. The seasonal ratio of stable and unstable conditions are closely related to the temperature difference between sea surface and air. In stable and semi-stable condition, latent and sensible heat fluxes have very small values without any relationship with wind speed. Though friction velocity shows slightly increasing trend with wind speed, it has many outliers. In unstable condition, turbulent fluxes increased with wind speed. Especially, latent heat flux increased rapidly during DJF. The latent heat flux at high wind speeds is more scatter.

FORMULATION AND STABILITY TEST OF ANTIAGING CREAM CONTAINING METHANOL FRACTION OIL OF PANGIUM EDULE.REINW. AS A RADICAL SCAVENGER AGENT

  • Djajadisastra, J.;Anwar, E.;Milani, E.
    • 대한화장품학회:학술대회논문집
    • /
    • 대한화장품학회 2003년도 IFSCC Conference Proceeding Book II
    • /
    • pp.303-306
    • /
    • 2003
  • Indonesia is a tropical country having a temperature range of 25-35$^{\circ}C$ which can affect the skin and causes damages like aging. This aging process is due, at least, to free radical reactions. For this reason, many attempts had been done to find out creams containing natural antioxidant compound which have a potential of free radical scavenger. Kluwek, a fermented form of foot ball fruit or picung (Pangium edule.Reinw), had been proved to contain antioxidant compound in its methanol fraction oil to which antiaging cream was formulated. Stability evaluation was conducted for cream with Kluwek oil compared to base cream, including organoleptic (colour and odour), pH, viscosity, particle size, centrifugation test and flow characteristics either in room temperature (27$^{\circ}C$) or stress condition (4$^{\circ}C$ and 5$0^{\circ}C$) for 8 weeks continuously, and six times cycling test at 4$^{\circ}C$ and 5$0^{\circ}C$ every 24 hours. The results showed that cream with Kluwek oil and base cream were stable at temperature 27 and 4$^{\circ}C$, cycling test and centrifugation test, but not stable at 5$0^{\circ}C$. Free radical evaluation was done by Electron Spin Resonance and the result showed that cream with Kluwek oil had less free radicals compared to base cream.

  • PDF

Damped Bypass Valve의 내부 누설 유동 특성 전산 해석 (Numerical Analysis for Internal Leakage Flow Characteristics of Damped Bypass Valve)

  • 이세욱;김대현;김상범;박상준;조진수
    • 한국항공우주학회지
    • /
    • 제41권2호
    • /
    • pp.85-90
    • /
    • 2013
  • 비행조종작동기 제어용 파일럿 밸브의 내부 유동 및 응답 특성을 분석하기 위해 유동의 수치 해석을 수행하였고 내부 누설 특성을 해석하였다. 온도 변화에 따른 누설을 고려한 밸브의 작동온도를 결정할 수 있는 영역을 제안 할 수 있었다. 미량의 작동유체가 누설 영역으로 유출된다는 것을 확인하였으나 누설 효과는 작동 온도에 따라 영향을 미치지 않는 것을 확인하였다. 압력 상승률이 온도가 하강할수록 높아지는 경향을 나타냈다.

기-액 상변화 열전달식 고온 히터 플레이트의 작동 특성과 성능에 관한 연구 (A Study on the Heat Transfer Characteristics and Performance of the High Temperature Range Heater Plate Using Liquid-Vapor Phase Change Heat Transfer)

  • 강환국;임광빈
    • 한국표면공학회지
    • /
    • 제46권6호
    • /
    • pp.283-289
    • /
    • 2013
  • The experimental study for the temperature uniformity on the wafer using liquid-vapor phase heat transfer mechanism is performed. For the experiment, the heater plate which is consist of stainless steel container, working fluid and electrical heater is designed, manufactured and tested at the range of 600 to $850^{\circ}C$. The results showed that the phase change type heater plate was much more uniform and stable temperature on the heater plate surface and wafer than the uniform heat flux type heater plate at the atmospheric condition. Also, the results of 300 mm outer diameter of heater plate showed that the same temperature uniformity compared with 230 mm.

지르코니아 겔에서 열처리에 따른 광발광의 변화 (Variation of Photoluminescence in Zirconia Gel by Pyrolysis)

  • 한규석;고태경
    • 한국세라믹학회지
    • /
    • 제45권2호
    • /
    • pp.126-131
    • /
    • 2008
  • In this study, we prepared zirconia gel by the sol-gel method and investigated its photoluminescence properties by varying pyrolysis temperature. The addition of acetic acid into a Zr-alkoxide solution resulted in forming the bidentate ligands with Zr ions and producing a stable gel. At the pyrolysis temperature of $350^{\circ}C$, the zirconia nanocrystals with tetragonal structure gradually appeared in the gel. The PL intensity of the zirconia gel increased with increasing the pyrolysis temperature up to $350^{\circ}C$, but decreased above the temperature. Concurrently, its PL peak wavelength continuously shifted from ${\sim}440\;nm$ to ${\sim}550\;nm$ with the temperature. The PL characteristics of the zirconia gels were closely associated with decomposition of residual organic groups, the formation of the zirconia nanocrystals, and the tetragonal to monoclinic phase transformation.

저온잠열저장을 위한 TMA-물계 포접화합물의 냉각특성에 대한 연구 (A Study on Cooling Characteristic of TMA-Water Clathrate Compound for Low Temperature Latent Heat Storage)

  • 김창오;김진흥;정낙규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2471-2475
    • /
    • 2007
  • Clathrate compound is the material that host in hydrogen bond forms cage and guest is included into it and combined. Crystallization of hydrate is generated at higher temperature than that of ice from pure water. And physical properties according to temperature are stable and congruent melting phenomenon is occurred without phase separation. But clathrate compound still had supercooling problem occurred in the course of phase change and supercooling should be minimized because it affects efficiency of equipment very much. Therefore, various studies on additives to restrain this or heat storage methods are needed. In this study was investigated the cooling characteristics of the TMA-water clathrate compound including TMA (Tri-methyl-amine, $(CH_3)_3N)$ of 20${\sim}$25 wt% as a low temperature latent heat storage material. And ethanol$(CH_3CH_2OH)$ was added and its cooling characteristics were studied experimentally to restrain supercooling of TMA-water clathrate compound.

  • PDF

Modified Ramp-Reset Waveform Robust for Variable Panel Temperature and its Discharge Characteristics

  • Jang, Soo-Kwang;Tae, Heung-Sik;Kim, Soon-Bae;Jung, Eun-Young;Suh, Kwang-Jong;Ahn, Jung-Chull;Heo, Eun-Gi;Lee, Byung-Hak;Lee, Kwang-Sik
    • Journal of Information Display
    • /
    • 제7권1호
    • /
    • pp.25-29
    • /
    • 2006
  • By the voltage threshold (Vt) close-curve measurement method, the changes in the discharge characteristics such as a firing voltage and IR emission among the three electrodes were examined relative to the low or high panel temperature ranging from -10 to $80^{\circ}$. The variation in the panel temperature was found significantly influence the surface discharge between the MgO surfaces rather than the plate gap discharge between the MgO and phosphor layers. Based on this experimental observation, a modified reset waveform that alleviates the surface discharge during a ramp-up and -down period was deeloped. By adopting the proposed reset waveform, a stable address discharge could be obtained irrespective of the panel temperature variation.

지중열전도도 측정과 지중열교환기의 열확산 특성 분석 (Measurement of Ground Thermal Conductivity and Characteristics of Thermal Diffusion by the Ground Heat Exchanger)

  • 정영만;구경민;황유진;장세용;이영호;이동혁;이재근
    • 설비공학논문집
    • /
    • 제20권11호
    • /
    • pp.739-745
    • /
    • 2008
  • This paper presents the measurement of ground thermal conductivity and the characteristics of ground thermal diffusion by a ground heat exchanger(GHE). A borehole is installed to a depth of 175 m with a diameter of 150 mm. To analyze the thermal diffusion property of the GHE, thermocouples are installed under the ground near the GHE. The outdoor temperature, the ground temperature, and the water temperature of the GHE are monitored for evaluating the characteristics of ground thermal diffusion. The ground thermal conductivity is evaluated by the in-situ thermal response tester and the line source model. It is found to be 3.08 W/$m^{\circ}C$ in this study. The ground temperature is greatly dependent on the outdoor temperature from the ground surface to 2.5 m in depth and is stable below 10 m in depth. The surface temperature of the GHE varies as a function of the temperature of circulating water. But the ground temperature at 1.5 m far from the GHE is not changed in accordance with the temperature of circulating water.