• Title/Summary/Keyword: temperature limit

Search Result 1,360, Processing Time 0.028 seconds

Molecular Isolation and Characterization of the 2CysPrx Gene from Salicornia herbacea (퉁퉁마디로부터 2CysPrx 유전자 분리 및 특성 분석)

  • Kim, Suk-Kyu;Chung, Sang Ok;Na, Gil-Jong
    • Korean Journal of Environment and Ecology
    • /
    • v.30 no.5
    • /
    • pp.810-820
    • /
    • 2016
  • This study is focused on the investigation of the genes which are induced by various stresses of the halophyte Salicornia herbacea. One of the factors influencing in the germination of Salicornia herbacea is salt stress. The highest germination rate was found in the condition without NaCl, and the upper limit of the NaCl concentration for the germination of Salicornia herbacea was 7%. The optimal temperature of $20^{\circ}C$showed a germination rate of 98%. Among genes induced by stress the 2CysPrx gene was cloned and analyzed for this study. The 2CysPrx gene has two cysteine conserved residues and is composed of 275 amino acids with molecular weight of 30.1kDa. The 2CysPrx gene appeared to be one copy in the genome and consists of 6 introns and 7 exons. Quantitative real-time PCR revealed that the highest transcription rate induced by NaCl and $H_2O_2$ appeared to be at the concentration of 3.5% NaCl and 40mM $H_2O_2$, respectively. The amount of transcript induced by high temperature($40^{\circ}C$) and $75{\mu}M$ of ABA was respectively highest. The gene at low temperature ($4^{\circ}C$) appeared not to be expressed. We are conducting to clone other peroxyredoxin genes induced by various environmental stresses.

Detonation Characteristics of L. P. G /$O_2$Gas Mixture and the Self-Ignition Condition for the Formation of Detonative Wave (액화석유 가스 (L. P. G) 와 산소 혼합물의 폭발특성 및 점화조건에 관한 연구)

  • Sung Nak Choi;Kyu Sun Shim;Un Sik Kim;Sock Sung Yun;Ung Kim
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.4
    • /
    • pp.394-402
    • /
    • 1986
  • Detonation reaction in L.P.G./$O_2$ mixture gas has been investigated over the L.P.G. concentration range of 3∼45 volume%. The variation of detonation velocity with mixture ratio is very interesting as it shows and inflection point near at the stoichiometric ratio. This might be ascribed to the fact that the detonation reactions at fuel-rich condition and fuel-lean condition proceed via different mechanisms. The maximum detonation velocity of 2.65km/sec occurs not at stoichiometric ratio(${\phi}$=1) but at fuel-rich condition (${\phi}$=1.57). Assuming that a stable detonation wave must propagates with the constant velocity, The upper and lower limit of detonation were determined and found to be 40.0 and 3.40 L.P.G. volume% respectively. The shock-heating technique was also utilized for the measurement of self-ignition temperature onsetting a stable detonation wave at varous mixture ratios. The self-ignition temperature at stoichiometric ratio is $742{\pm}3{\circ}K$ and the self-ignition temperature increases as the mixture ratio deviates from the stoichiometric condition.

  • PDF

Quantitative Microbial Risk Assessment of Non-thermal Processed Japanese Foods Using Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 일식메뉴 중 비가열 처리 식품의 정량적 위해평가)

  • Song, Ju-Hyun;Choi, Yu-Jin;Nang, Hyo-Min;Lee, Kwang-Geun
    • Food Engineering Progress
    • /
    • v.13 no.1
    • /
    • pp.56-63
    • /
    • 2009
  • The aim of this study was to control the outbreak of food pathogen through quantitative microbial risk assessment (QMRA). We used Monte Calro Simulation (MCS) to predict contamination levels of Staphylococcus aureus on the raw materials, equipments and cook in Japanese restaurant located in Seoul. The result of sensitivity analysis showed that the most significant factor for the outbreak of food pathogen was consumption temperature and storage time. In shrimp and octopus sushi, 'consumption temperature' was the highest sensitivity value of 0.419 followed by 'storage time' of 0.374. To increase safety of sushi, consumers should have sushi as soon as possible after cooking. In sushi 'storage time after cooking' was determined as Critical Control Point (CCP). To determine Control Limit (CL), Scenario Analysis (SA) was carried out. In sushi, SA was carried out using storage time as a unit condition. Safety level of S. aureus was set lower than 5 log CFU/g. After 2 hr 'storage time' the number of S. aureus increased to 3.908 log CFU/g. Therefore, 'storage time' of sushi was set as CL in case of room temperature storage.

Agrometeorological Analysis on the Freeze Damage Occurrence of Yuzu Trees in Goheung, Jeonnam Province in 2018 (2018년 전라남도 고흥 유자나무 동해 발생에 대한 기상학적 구명)

  • Kim, Gyoung Hee;Koh, Young Jin;Kim, Kwang-Hyung
    • Research in Plant Disease
    • /
    • v.25 no.2
    • /
    • pp.71-78
    • /
    • 2019
  • In 2018, severe diebacks have occurred on yuzu trees cultivated in Goheung, Jeonnam Province. On-farm surveys at 18 randomly selected orchards revealed the dieback incidence ranged from 7.5% to 100% with an average of 43.6%, and 56.6% of the affected yuzu trees were eventually killed. In order to find the reason for this sudden epidemic, we investigated the weather conditions that are exclusively distinct from previous years, hypothesizing that certain weather extremes might have caused the dieback epidemic on yuzu trees. Since different temperatures can cause freeze damage to plants depending on their dormancy stages, we investigated both periods when yuzu becomes hardy under deep dormancy (January-February) and when yuzu loses its cold hardiness (March-April). First, we found that daily minimum air temperatures below $-10^{\circ}C$ were recorded for 7 days in Goheung for January and February in 2018, while no occasions in 2017. In particular, there were two extreme temperature drops ($-12.6^{\circ}C$ and $-11.5^{\circ}C$) beyond the yuzu cold hardiness limit in 2018. In addition, another occasion of two sudden temperature drops to nearly $0^{\circ}C$ were occurred right after abnormally-warm-temperature-rises to $13^{\circ}C$ of daily minimum air temperatures in mid-March and early April. In conclusion, we estimated that the possible damages by several extreme freeze events during the winter of 2018 could be a major cause of severe diebacks and subsequently killed the severely affected yuzu trees.

Assessment of temperature-dependent water quality reaction coefficients and monthly variability of residual chlorine in water distribution networks (수온 변화에 따른 상수관망 내 수질반응계수 추정 및 월별 잔류염소농도 분포 변화 분석)

  • Jeong, Gimoon;Choi, Taeho;Kang, Doosun;Lee, Juwon;Hwang, Taemun
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.11
    • /
    • pp.705-720
    • /
    • 2023
  • In South Korea, ongoing incidents related to drinking water quality have eroded consumer trust. Specifically, beyond quality incidents, there have been complaints about taste, odor, and other issues stemming from the presence of chlorine. To address this, water service operators are employing various management strategies from both temporal (scheduling) and spatial (rechlorination) perspectives to ensure uniform and safe distribution of chlorine residuals. In this study, we focus on the optimal monthly management of chlorine residuals, based on water distribution network analysis. Water quality reaction coefficients, including bulk fluid and wall reaction coefficients, were estimated through lab-scale tests and EPANET water quality simulations, respectively, accounting for temperature variations in a large-scale water distribution network. Utilizing these estimated coefficients, we examined the monthly variations in chlorine residual distribution under different chlorine injection conditions. The results indicate that the efficient concentration for chlorine injection, which satisfies the residual chlorine limit range, varies with temperature changes. Consequently, it is imperative to establish a specific and quantitative chlorine injection plan that considers the accurate spatial distribution of monthly chlorine residuals.

A study on prediction and improvement method of fire risk for a newly built college dormitory (신축 승선생활관의 화재 위험성 예측 및 개선방안에 관한 연구)

  • Kim, Byeol;Hwang, Kwang-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.228-234
    • /
    • 2016
  • As a college dormitory has the features of high dwelling density and a floating population that becomes crowded during particular times, when a disaster such as a fire occurs, it has the risk of causing much loss of life. In this study, the fire simulation program Fire Dynamics Simulator (FDS), is used to predict the risk when a fire occurs, to analyze the problem, and to suggest an improvement plan for a new cadet dormitory at an university in Korea. The research results are as follows. When a fire occurred in the ironing room inside the cadet dormitory, a smoke detector operated after 65 seconds. Thirteen seconds later, a sprinkler started to operate. The temperature and carbon monoxide density reached the limit value at 241 and 248 seconds, respectively. Because the limit visibility value was reached within 66 seconds after the occurrence of a fire, it is predicted that preparation must be finished and evacuation should begin within 1 minute after the fire occurs, in order to have no casualties. Synthesizing this dormitory fire risk prediction result, the visibility value is considered to be the most dangerous factor for personal safety. Because of this, installing a smoke extraction system is suggested to secure visibility. After the installation of a smoke extraction system, the problem of smoke diffusion in the corridors improved.

Simultaneous analysis of 12 kind maker components in Banhabaekchulchhonma-tang by RP-HPLC (RP-HPLC를 이용한 반하백출천마탕에서 12종 지표성분의 동시분석)

  • Lee, Kwang Jin;Yang, Hye Jin;Ma, Jin Yeul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4682-4691
    • /
    • 2014
  • Banhabaekchulchhonma-tang is a traditional Korean herbal prescription with a range of pharmacological activities. In this study, the simultaneous analysis of 12 kinds of marker components, Homogentisic acid, Hesperidin, Naringin, Alisol A, Atractylenolide II, Atractylenolide III, Ginsenoside Rg1, Formononetin, Gastrodin, Berberine, Palmatine and 6-gingerol, in Banhabaekchulchhonma-tang was performed using high-performance liquid chromatography (RP-HPLC). The standard sample of commercial $C_{18}$ reversed phase-column using water (0.1% TFA) and acetonitrile as the mobile phase with a step gradient elution mode. The flow rate (1.0mL/min), injection volume ($10{\mu}L$) and column oven temperature ($40^{\circ}C$) at a 200, 220, 280 and 340nm wavelength was conducted. All calibration curves of the standard components showed good linearity ($r^2$ >0.999). In addition, the limit of detection (LOD) and limit of quantification (LOQ) ranged from 0.012 to $0.878{\mu}g/mL$ and 0.009 to $0.290{\mu}g/mL$. The precision intra-day and inter-day were ranged from 0.07 to 1.21% and 0.20 to 0.90%, respectively. The recoveries ranged from 97.17 to 108.40%. Each sample amount showed a very small change. These results highlight the efficient quality evaluation of Banhabaekchulchhonma-tang.

A Study on Establishment of Technical Guideline of the Installation and Operation for the Efficient Bio-gasification Facility of Pig Manure and Food Waste(III): Design and Operation Guideline (가축분뇨 병합처리 바이오가스화를 위한 설계 및 운전 기술지침 마련 연구(III) 설계 및 운전 지침(안) 중심으로)

  • Lee, Dongjin;Moon, HeeSung;Son, Jihwan;Bae, Jisu
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.25 no.3
    • /
    • pp.99-111
    • /
    • 2017
  • The purpose of this study is to provide a design and operation technical guideline for meeting the appropriate design criteria to bio-gasification facilities treating organic wastes. Based on the results obtained during the field surveys, the overall design and operation guidelines for bio-gasification facilities, monitoring items, cycle and commissioning period were presented. According to the flow of anaerobic digestion process, Various design factors for bio-gasification facilities were proposed in this study. When designing the initial anaerobic digestion capacity, 10 ~ 30% of the treatment capacity was applied considering the discharge characteristics by the incoming organic wastes. At the import storage hopper process, limit concentration of transporting organic wastes was limited to TS 10 % or less, and limit concentration of inhibiting factor was suggested in operation of anaerobic digester. In addition, organic loading rate (OLR) was shown as $1.5{\sim}4.0kgVS_{in}/(m^3{\cdot}day)$ for the combined bio-gasification facilities of animal manure and food wastes. Desulfurization and dehumidification methods of biogas from anaerobic digestor and proper periods of liquifization tank were suggested in design guideline. It is recommended that the operating parameters of the biogasification facilities to be maintained at pH (acid fermentation tank 4.5~6.5, methane fermentation tank 6.0~8.0), temperature variation range within $2^{\circ}C$, management of volatile fatty acid and ammonia concentration less than 3,000 mg/L, respectively.

A Case Study on the Ventilation and Heat Environment in a Underground Limestone Mine with Rampway (Rampway 설치 석회석 광산내 환기 현황 및 열환경 분석 사례연구)

  • Kim, Doo-Young;Lee, Seung-Ho;Jeong, Kyu-Hong;Lee, Chang-Woo
    • Tunnel and Underground Space
    • /
    • v.22 no.3
    • /
    • pp.163-172
    • /
    • 2012
  • As more diesel engines have been employed in underground limestone mines with large cross section, underground space environment is worsened by diesel exhausts and heat flow. This paper aims for the ultimate goal to optimize the work place environment through assuring the optimal required ventilation rate based on the analysis of the airflow, diesel exhaust gas concentrations and the effects of mechanization and deepening working face on temperature and humidity. Due to the insufficient capacity of the main exhaust fan and poor airway management, stagnant airflows were observed at various locations, while the flow direction was reversed instantly with passing diesel equipment and the flow reversal was also made by the seasonal variation of the outside surface weather. During the loading operation, CO concentration measurements were found to be frequently higher than the threshold limit of 50 ppm, and most of the $NO_2$ measurements during drilling and loading operations shows even more serious levels surpassing the permissible limit of 3 ppm. The actual ventilation quantity was considerably less than the required quantity estimated by the mine health and safety law, and this shortage problem was less serious in colder winter showing more effectiveness of the natural ventilation.

Optimization of Analytical Conditions for the Quantification of Explosive Compounds in Soil using HPLC (HPLC에 의한 토양내 화약물질 정량분석조건 최적화)

  • Cho, Jung-Hyun;Bae, Bum-Han;Kim, Kye-Hoon
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.1
    • /
    • pp.51-60
    • /
    • 2009
  • A series of experiments was performed to develop an optimized analytical procedure for the analysis of explosives in soil by HPLC with soil samples collected at two live-fire military shooting ranges. The minimum amount of soil to be collected, Wmin, for the analysis of explosive compounds was 125g, based on the segregation and homogeneity constants that account for soil heterogeneity and non-homogeneous distribution of target explosive compounds. The optimization of extraction and HPLC analytical conditions were also studied based on analytes CV values. The most effective soil/ extractant ratio was estimated to be 10g-pretreated soil/20 mL acetonitrile as extractant. The optimized HPLC elution conditions for the separation of US EPA designated 14 explosive compounds, were column temperature 30${\circ}C$, eluents ratio of isopropanol: acetonitrile: water = 18 : 12: 70, and flow rate of 0.8 mUmin at 230 nm. However, UV wavelength 254 nm was better for the analysis of NB, 2,4-DNT, 2NT, 4NT, and 3NT.