• Title/Summary/Keyword: temperature characteristic

Search Result 2,919, Processing Time 0.029 seconds

Fabrication of the thermopile using SOI structure (SOI 구조를 이용한 열전쌍열(Thermopile) 제작)

  • Lee, Young-Tae;Takao, Hidekuni;Ishida, Makoto
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • In this paper, a thermopile which is applied to wide uses of temperature measuring was fabricated and its characteristic was improved by appling SOI structure to the fabrication. We improved characteristic of the thermopile by using single crystal silicon strips that has high seebeck coefficient and dielectric isolating the silicon strips from substrate with silicon dioxide film which dramatically decrease thermal conductivity between hot and cold junction compared to a silicon strip which was fabricated by ion implantation. The thermopile consists of 17 p-type single crystal silicon strips and 17 n-types by serial connection. The result of electromotive force measuring showed very good characteristic as 130mV/K when temperature difference between the two ends of the thermopile occurs by applying light on the thermopile fabricated with silicon strips of $1600{\mu}m$ length, $40{\mu}m$ width, $1{\mu}m$ thickness.

Removal of Contaminants Deposited on Surfaces of Matrices by Using Low-Temperature Argon Plasma Treatment (저온 아르곤 플라즈마처리를 이용한 모재 표면의 오염물 제거)

  • Seo, Eun-Deock
    • Journal of Conservation Science
    • /
    • v.30 no.3
    • /
    • pp.299-306
    • /
    • 2014
  • The possibility of a low-temperature argon plasma treatment as a mean of restoration technology for contaminated invaluable archive materials and artefacts, and evidencing documents was investigated along with an oxygen plasma treatment for comparison. For this purpose, the degree of color changes, ${\Delta}E^*ab$, and surface morphological changes due to plasma treatments as an evaluation of removal performance of artificial contaminants such as brilliant green dye and carbon deposit on cellulose acetate and plain paper as matrices, respectively, were measured and analyzed using a spectrophotometer and a field emission scanning electron microscope. Compared to the argon plasma treatment with sputtering characteristic, that of the oxygen plasma with characteristic of an oxidation reaction has shown superior results in removing the contaminants; the oxygen plasma has proven to damage the matrices significantly due to its oxidative characteristic, and post-plasma reactions has anticipated to be also detrimental to the surfaces, whereas, the problems caused by the counterpart has resulted in being negligible and rather has thought to be an appropriate mean for delicate restoration and/or removal operations of contaminants.

Protection properties of HTS coil charging by rotary HTS flux pump in charging and compensation modes

  • Han, Seunghak;Kim, Ji Hyung;Chae, Yoon Seok;Quach, Huu Luong;Yoon, Yong Soo;Kim, Ho Min
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.4
    • /
    • pp.19-24
    • /
    • 2021
  • The low normal zone propagation velocity (NZPV) of high-temperature superconducting (HTS) tape leads to a quench protection problem in HTS magnet applications. To overcome this limitation, various studies were conducted on HTS coils without turn-to-turn insulation (NI coils) that can achieve self-protection. On the other hand, NI coils have some disadvantages such as slow charging and discharging time. Previously, the HTS coils with turn-to-turn insulation (INS coils) were operated in power supply (PS) driven mode, which requires physical contact with the external PS at room-temperature, not in persistent current mode. When a quench occurs in INS coils, the low NZPV delays quench detection and protection, thereby damaging the coils. However, the rotary HTS flux pump supplies the DC voltage to the superconducting circuit with INS coils in a non-contact manner, which causes the INS coils to operate in a persistent current mode, while enabling quench protection. In this paper, a new protection characteristic of HTS coils is investigated with INS coils charging through the rotary HTS flux pump. To experimentally verify the quench protection characteristic of the INS coil, we investigated the current magnitude of the superconducting circuit through a quench, which was intentionally generated by thermal disturbances in the INS coil under charging or steady state. Our results confirmed the protection characteristic of INS coils using a rotary HTS flux pump.

Neuro PID Control for Ultra-Compact Binary Power Generation Plant (초소형 바이너리 발전 플랜트를 위한 Neuro PID 제어)

  • Han, Kun-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.11
    • /
    • pp.1495-1504
    • /
    • 2021
  • An ultra-compact binary power generation plant converts thermal energy into electric power using temperature difference between heat source and cooling source. In the actual power generation environment, the characteristic value of the plant changes due to any negative effects such as environmental condition or corrosion of related equipment. If the characteristic value of the plant changes, it may lead to unstable output of the turbine in a conventional PID control system with fixed PID parameters. A Neuro PID control system based on Neural Network adaptively to adjust the PID parameters according to the change in the characteristic value of the plant is proposed in this paper. Discrete-time transfer function models to represent the dynamic characteristics near the operating point of the investigated plant are deduced, and a design strategy of the proposed control system is described. The proposed Neuro PID control system is compared with the conventional PID control system, and its effectiveness is demonstrated through the simulation results.

Effects of Temperature and Salinity on the Hemolymp Characteristic and Composition of Free Amino Acid of the Abalone, Haliotis discuss hannai (수온과 염분이 참전복, Haliotis discuss hannai의 혈림프액 성상과 유리아미노산 조성에 미치는 영향)

  • Yang, Sung Jin;Lee, Jeong Young;Hwang, Hyung Kyu;Min, Byung Hwa;Shin, Yun Kyung;Myeong, Jeong In
    • Journal of Marine Life Science
    • /
    • v.1 no.1
    • /
    • pp.50-55
    • /
    • 2016
  • Glucose was continuously increased as time was elapsed under the temperature at 6℃ and 4℃. NH3 was significantly increased at 4℃. AST was increased as temperature and salinity were decreased which indicated that it was affected by temperature, salinity and interaction of temperature×salinity. ALT was significantly increased as temperature was decreased. Free amino acid contents, excluding aspartic acid, threonine, serine and glycine were increased as temperature was decreased. This decreasing tendency was also observed when salinity was decreased. Taurine, aspartic acid, glutamic acid and arginine were significantly increased as salinity was decreased, while glycine, alanine, methionine, tyrosine, and histidine were decreased as salinity was decreased. The result of this study suggested that transport condition to minimize the stress is considered in the range of 30~34 psu, 8~10℃.

Combustion Characteristic of Paper Sludge Using TGA Reactor (열중량 반응기를 이용한 제지슬러지의 연소 특성)

  • Yook, Chan-Nam;Kim, Jung-Soo;Han, Kwang-Soo
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.48-58
    • /
    • 2003
  • To obtain the preliminary design data for combustion of paper sludges, decomposition characteristics and combustion kinetics of paper sludges reactor have been determined in a TGA reactor. Also, the combustion characteristics of paper sludges have been determined in a fluidized bed reactor. The data obtained from the TGA reactor indicate that dewatering of paper sludge is terminated at temperature below 130${\circ}$C. With heating rate of 20${\circ}$C/min, combustion is terminated at temperature below 340${\circ}$C .The combustion rate is found to be first order with respect to temperature and oxygen concentration. Activation energies for paper wastes are found to be 570, 700, 2600, 4600 Kcal/mole, respectively. The calcination conversions were investigated with the operating temperature and residence time. In this investigation, it was found that calcination conversion was affected by the operating temperature and residence time. The optimum conditions of operating temperature and mean residence time were 850${\circ}$C and 6 minutes of respectively.

Heat Transfer by an Oscillating Flow in a Circular Pipe with Sinusoidal Wall Temperature Distributions (벽온도분포가 정현파인 원관에서 왕복유동에 의한 열전달 해석)

  • 이대영;박상진;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.12
    • /
    • pp.3208-3216
    • /
    • 1993
  • Heat transfer characteristics of the laminar oscillating flow in a circular pipe have been studied under the condition that the wall temperature of the pipe is distributed sinusoidally with the axial direction. The axial velocity was assumed to be uniform in radial direction and the temperature field was analyzed by means of the perturbation method. The results show that the difference between wall and section-time-averaged fluid temperature increases as the oscillating frequency increases and eventually converges to a constant value which is determined by the ratio of swept distance to the characteristic length of wall temperature distribution. Also it is shown that the dominant variable in the heat transfer process when swept distance ratio is greater than 1 is not thermal Womersley number(F) but thermal Womersley number multiplied by the square root of swept distance ratio. The variation of the time-averaged Nusselt number is obtained as a function of F. The results indicate that Nusselt number is proportional to $F_{\epsilon}^{1/2}$ when both of F and .epsilon. are much greater than 1.

Fluctuation Characteristic of Temperature and Salinity in Coastal Waters around Jeju Island (제주도 연안 천해역의 수온 · 염분 변동 특성)

  • KO Jun-Cheol;KIM Jun-Teck;KIM Sang-Hyun;RHO Hong-Kil
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.3
    • /
    • pp.306-316
    • /
    • 2003
  • We conducted a time-series analysis of temperature and salinity of sea water around Jeju Island, Korea. Monthly mean temperature and salinity was influenced by precipitation and weather conditions on Jeju as well as by oceanographic conditions of the open sea such as the Tsushima Warm Current and sea water in coastal areas. Salinity of Jeju coastal waters was the highest in April, and it was always over 34.00 psu with tiny fluctuation between December and June. Due to the effects of the Tsushima Warm Current, Jeju coastal waters maintained high salinity and stability. Low salinity and its large fluctuations during summer were closely associated with the China Coastal Water and precipitation in Jeju. The place of the lowest water temperature was the northeast coasts of Jeju (Gimneong, Hado, Jongdalri). In winter, as warmer water of the Tsushima Warm Current appeared in western area of Jeju dwindled flowing along the northern coasts of Jeju area and becoming cool, the lowest water temperature often appeared locally in Gimnyeong and its vicinitly in summer. The Tsushima Warm Current flows into the east entrance of Jeju Strait, but its influence is weak because of geometry and strong vertical mixing due to fast tidal currents.

A study on the viscosity-temperature characteristics of the emulsified heavy fuel oils (유화중유의 점도-온도특성에 관한 연구)

  • 전대희;김기준;이상태
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.15-21
    • /
    • 1983
  • Preparing for treatment and management of the emulsified fuel oil which will be generalized henceforth, this paper is an attempt to examine the viscosity-temperature characteristics of emulsified heavy fuel oil which is mixed with water and emulsifier in various mixture ratio by mechanical mixer. The experimental results are summarized as follows: 1. The viscosity-temperature characteristics of the emulsified C & B grade heavy fuel oil mixed with water of same or less weight, is changed according to log.log(v+0.6)=b-3.8log T. 2. The emulsifier has to be added to the emulsified A grade heavy fuel oil mixed with water of same or less weight, because it is instable. Especially if the emulsifier is sodium stearate, it is added more than 0.3% of the weight of oil and water. 3. In the emulsified A grade heavy fuel oil mixed with water and emulsifier, the higher the ratio of water addition becomes, the higher the viscosity is and the more the viscosity-temperature slope decreases. But the higher the ratio of emulsifier addition is, the more the viscosity-temperature slope increases. In this case, the linearity of viscosity-temperature characteristic curve is poorer than that of B and C grade heavy fuel oil. 4. In the emulsified A grade heavy fuel oil mixed with emulsifier of 0.3% or less, the emulsion type is O/W type when water addition ratio is 40%, but it is W/O type when it is 10%, 20%, 30% and 50%.

  • PDF

Rock mechanics and wellbore stability in Dongfang 1-1 Gas Field in South China Sea

  • Yan, Chuanliang;Deng, Jingen;Cheng, Yuanfang;Yan, Xinjiang;Yuan, Junliang;Deng, Fucheng
    • Geomechanics and Engineering
    • /
    • v.12 no.3
    • /
    • pp.465-481
    • /
    • 2017
  • Thermal effect has great influence on wellbore stability in Dongfang 1-1 (DF 1-1) gas field, a reservoir with high-temperature and high-pressure. In order to analyze the wellbore stability in DF1-1 gas field, the variation of temperature field after drilling was analyzed. In addition, the effect of temperature changing on formation strength and the thermal expansion coefficients of formation were tested. On this basis, a wellbore stability model considering thermal effect was developed and the thermal effect on fracture pressure and collapse pressure was analyzed. One of the main challenges in this gas field is the decreasing temperature of the wellbore will reduce fracture pressure substantially, resulting in the drilling fluid leakage. If the drilling fluid density was reduced, kick or blowout may happen. Therefore, the key of safe drilling in DF1-1 gas field is to predict the fracture pressure accurately.