• 제목/요약/키워드: technical criteria

검색결과 635건 처리시간 0.032초

Application of surf-riding and broaching mode based on IMO second-generation intact stability criteria for previous ships

  • Shin, Dong Min;Moon, Byung Young;Chung, Jaeho
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제13권1호
    • /
    • pp.545-553
    • /
    • 2021
  • International Maritime Organization (IMO) have recently discussed the technical problems related to the second-generation intact stability criteria of ships. The second-generation intact stability criteria refer to five modes of vulnerability when the ship sailing in the ocean. In this study, we described a method to verify the criteria of the surf-riding/broaching. In case that Lv1 (Level 1) vulnerability criteria is not satisfied based on the relatively simple calculation using the Froude number (Fn), we presented the calculation procedure for the Lv2 (Level 2) criteria considering the hydrodynamics in waves. The results were reviewed based on the data for given previous ships. In absence of ship-specific data, a similar Lv2 result was confirmed by comparing the result obtained by calculating the added mass with the case where the added mass was 10% of the ship mass. This result will contribute to basic ship design process according to the IMO draft regulation.

고속화에 대응한 전차선로 설계 요소기술 (Design Essential Element Technology of Catenary System be in Correspondence with Speed-up)

  • 창상훈;김양수;박병수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.75-78
    • /
    • 2005
  • The decisive criteria to determine collection performance is the contact force between pantograph and catenary. The contact force consists of a static force and dynamic force related to vibration characteristics, train speed and etc. The low contact force leads to the loss of contact, and most countries regulate it below 1% at operation speed. This study presents a technical overview of criteria for collection performance of catenary system.

  • PDF

해수담수화 후보지역 조사 (A survey on the regional criteria required desalination)

  • 최병습
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.325-330
    • /
    • 1998
  • Seawater desalination is the production of the water, suitable for human consumption, from seawater. Since the water supply produced by desalination is at least as good, in quality than that provided by traditional catchment, the decision as to whether or not desalination plant is to be installed should be made on technical, social, economic grounds. By analysis of these criteria, we selected some regions required seawater desalination.

  • PDF

도시철도 simple catenary 가선구조에서의 집전성능 향상방안에 관한 연구 (Study on the Current Collection Characteristics and Improvement Methods of Simple Catenary Systems)

  • 박용철;창상훈;송중호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1360-1365
    • /
    • 2004
  • The decisive criteria to determine collection performance is the contact force between pantograph and catenary. The contact force consists of a static force and dynamic force related to vibration characteristics, train speed and etc. The low contact force leads to the loss of contact, and most countries regulate it below $3\∼5\%$ at operation speed. This study presents a technical overview of criteria for collection performance and modelling and simulation methods to analyze dynamic characteristics of catenary.

  • PDF

On the External Forces in Consideration for a Stability and Buoyancy Criteria of a Drilling Rig

  • Hun-Chol,Kim
    • 대한조선학회지
    • /
    • 제12권1호
    • /
    • pp.83-90
    • /
    • 1975
  • In order to establish a stability and buoyancy criteria of a floating vessel, the geometrical property as well as external forces and moments be dealt with. This paper discusses in general terms hidden but more salient factors of forces and moments of both natural and artificial origin, particularly wind, with regard to vessels of more general type such as oil drilling rigs.

  • PDF

건축전기설비분야의 성능중심 건설기술기준 작성 지침 개발 (Performance based Construction Specifications and Design Criteria Development Plan of Electrical Installations)

  • 김세동;이광식;최은혁
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.209-212
    • /
    • 2007
  • It is increased electrical energy consumption with the development of intelligence society in buildings and thus an energy conservation through efficient use of electricity and reliability, safety, etc became more important. This research paper intensively investigated performance based construction specifications and design criteria of electrical installations in domestic and foreign country. It is necessary to analyze the key features based on performance and general trend about contractor guarantee, warranty method, performance design criteria from the investigated data. This paper shows a reasonable performance based construction specifications and design criteria of electrical installations.

  • PDF

대안 평가를 위한 의사결정 기법 (Decision Methods for Evaluation of Alternatives)

  • 남기창;홍상표
    • 환경영향평가
    • /
    • 제9권4호
    • /
    • pp.363-372
    • /
    • 2000
  • For any particular development project or environmental regulations, decision-making criteria is required and conflicts among criteria should be resolved. It is necessary to investigate criteria that government agencies employ in making decisions that influence the environment. The evaluation of alternative development proposals and regulatory measures involves much more than environmental issues. Economic, technical, and social factors should be considered along with environmental impacts when making evaluations. Evaluation should be based on values of all individuals who may be affected by public or private decisions. There are many evaluation methods for determining how individuals and groups value alternative public actions. Numerous weighting-scaling methodologies can be used in such evaluations. These methodologies represent adaptations of multiple-criteria or multiple-attribute decision-making techniques. Environmental risk assessment which accounts for uncertainties in choosing among alternative policies and projects is increasingly used.

  • PDF

원전 터빈 발전기 비틀림 진동기준 국제표준규격(ISO 22266-1) 적용 사례 (Application Case of ISO 22266-1 for Establishing the Torsional Vibration Criteria of a Nuclear Turbine Generator)

  • 정혁진;송우석;이혁순
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 춘계학술대회 논문집
    • /
    • pp.225-226
    • /
    • 2010
  • ISO 22266-1 issued in May 2009 provides guidelines for applying shaft torsional vibration criteria, under normal operating conditions, for the coupled shaft system and long blades of a turbine generator set. In case that a turbine generator vendor do not meet the separation margin of torsional natural frequencies in the technical specifications of the purchaser, this standard can present the reasonable and objective criteria about torsional vibration which both purchaser and supplier can agree on, while ensuring the integrity of turbine generator. This paper describes the application case of ISO 22266-1 for the establishment of torsinal vibration criteria under retrofitting the turbine generator of 'U' nuclear power plant.

  • PDF

200 km/h급 전차선로 구조강도 설계기준에 관한 기술적 검토 (A Technical Review on the Structure Design Criteria for a Catenary System with Maximum Design Speed of 200 km/h)

  • 조용현;이기원;권삼영;최강윤;창상훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 춘계학술대회 논문집
    • /
    • pp.273-280
    • /
    • 2001
  • In this study, a comparison between the structural design criteria for a catenary system with the maximum design speed of 100km/h and that of 300km/h was performed in order to establish that of 200km/h. According to the result, catenary design criteria for 300km/h operation is more conservative than that for 100km/h operation. This result shows that higher wind pressure and safety factor are adopted to catenary design for 300km/h operation. So, for the purpose of the economic structural design for catenary system, it is necessary to review the adoption possibility of catenary system for 100km/h operation first. In order to review the adoption possibility for catenary system for 100km/h operation, design criteria for 300km/h operation should be chosen for safer catenary structure.

  • PDF

원전 증기발생기 전열관 관막음 한계 고찰 (A Review of Plugging Limit for Steam Generator Tubes in Nuclear Power Plants)

  • 강용석;이국희
    • 한국압력기기공학회 논문집
    • /
    • 제16권2호
    • /
    • pp.10-17
    • /
    • 2020
  • Securing the integrity of steam generator tubes is an essential requirement for safe operation of nuclear power plants. Therefore, tubes that do not satisfy integrity requirements are no longer usable and must be repaired according to the related requirements. In general, the repair criterion is that the damage depth is more than 40% of the tube wall thickness. However, the plugging limit can be changed and be applied, provided a technical proof is given that integrity can be secured against specific degradation at a specific plants and that approval can be obtained from a regulatory agency. A typical example is alternative repair criteria for defects within the tube sheet or tube support plates. In this paper, a background of establishing the plugging limit for steam generator tubes and changes in maintenance criteria are reviewed as examples.