• Title/Summary/Keyword: team treatment

Search Result 1,173, Processing Time 0.024 seconds

Embrittlement Behavior of Zirconium Alloy in Quenching Heat Treatment (급랭 열처리시 지르코늄 합금의 취성 거동)

  • Kim, Jun Hwan;Lee, Jong Hyuk;Choi, Byoung Kwon;Jeong, Yong Hwan
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.17 no.4
    • /
    • pp.216-222
    • /
    • 2004
  • Study was focused on the quenching embrittlement property of Zircaloy-4 cladding simulated Loss Of Coolant Accident (LOCA) environment in terms of high temperature oxidation and phase transformation. Property in LOCA condition of advanced cladding that contained Nb element was also investigated. Claddings were oxidized at given temperature and given time followed by water quenching. The results showed that ${\beta}$ phase which formed at quenching stage has an influence on cladding property. In case of advanced cladding, Nb retards cladding oxidation, thus enhances quenching resistance.

Transdermal Permeation Behavior of 5-FU using Microneedle (마이크로니들을 이용한 5-FU의 경피투과 거동)

  • Kim, Myoung-Jin;Park, Jung-Soo;Kim, Yun-Tae;Lee, Jun-Hee;Ahn, Sik-Il;Park, Jong-Hak;Mo, Jong-Hyun;Lee, Tae-Wan;Lee, Han-Koo;Khang, Gil-Son;Lee, Hai-Bang
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.1
    • /
    • pp.45-50
    • /
    • 2008
  • 5-Fluorouracil (5-FU) is an antimetabolic of the pyrimidine derivatives that is used in chemotherapy for the treatment of several types of cancer. 5-FU have poor oral absorption and short biological half-time and strong side effects. Microneedle introduced to find a solution of problems. Microneedle device with roll was manufactured for transdermal delivery of various drugs. 5-FU was mixed in non-ionic surfactant such as tween 20 and tween 80. Camscope was used to analysis the permeation magnitude of treated skin by microneedle and trypan blue staining. The 5-FU solution with surfactant measured by ZETA-potential analysis system for stability of solution. The skin permeation rate of 5-FU determined by HPLC. We confirmed that cross treated skin was dyed more deeply than parallel treated skin through trypan blue staining. The results indicate that skin permeation rate of 5-FU was increased with the treatment types and treatment times.

The effect of 3-mercapto-5-nitro-benzimidazole (MNB) and poly (methyl methacrylate) (PMMA) treatment sequence organic thin film transistor

  • Park, Jin-Seong;Suh, Min-Chul;Jeong, Jong-Han;Kim, Su-Young;Mo, Yeon-Gon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1174-1177
    • /
    • 2006
  • A bottom contact organic thin film transistor (OTFT) is fabricated with an organic double-layered gate insulator (GI) and pentacene. The PMMA and MNB layers are treated on gate insulator and source/drain (S/D, Au) before depositing pentacene to investigate device properties and pentacene growth. The sequence of surface treatment affects a device performance seriously. The ultra-thin PMMA (below 50A) was deposited on organic gate insulator and S/D metal by spin coating method, which showed no deterioration of on-state current (Ion) although bottom contact structure was exploited. We proposed that the reason of no contact resistance (Rc) increase may be due to a wettability difference in between PMMA / Au and PMMA / organic GI. As a result, the device treated by $PMMA\;{\rightarrow}\;MNB$ showed much better Ion behavior than those fabricated by $MNB\;{\rightarrow}\;PMMA$. We will report the important physical and electrical performance difference associated with surface treatment sequence.

  • PDF

Effect of Microstructure and Alloying Element on the ISCC Characteristics of Zr Cladding (Zr 피복관의 ISCC 특성에 미치는 미세조직 및 첨가원소의 영향)

  • Park, Sang Yoon;Choi, Byoung Kwon;Lee, Myung Ho;Kim, Jun Hwan;Jeong, Yong Hwan
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.18 no.3
    • /
    • pp.164-171
    • /
    • 2005
  • Iodine-Induced Stress Corrosion Cracking (ISCC) properties of Zircaloy-4 and HANA4 developed in KAERI for the high burn-up nuclear fuel cladding were evaluated. To confirm the effect of final heat treatment on ISCC resistance of Zr-alloy, stress relieved and recrystallized specimens were prepared and tested. With the pre-cracked specimen at internal surface, ISCC crack propagation rates and threshold stress intensity factor ($K_{ISCC}$) based on the fracture mechanics were measured by internal pressurization test at $350^{\circ}C$ in iodine environment. $K_{ISCC}$ of Zircaloy-4 and HANA4 cladding were $3.3MPa{\cdot}m^{1/2}$ and $4.4MPa{\cdot}m^{1/2}$, respectively. Pitting corrosion at the crack surface was observed and it seemed that TG crack propagation was derived from the pitting.

Transdermal Delivery of Bufexamac using Microneedle System (마이크로니들시스템을 이용한 부펙사막의 경피전달)

  • Mo, Jong Hyun;Kim, Yun Tae;Park, Jung Soo;Lee, Jun Hee;Lee, Tae-Wan;Khang, Gilson;Rhee, John Moon;Lee, Han-Koo;Lee, Hai Bang
    • Korean Chemical Engineering Research
    • /
    • v.46 no.2
    • /
    • pp.211-216
    • /
    • 2008
  • Bufexamac which was used for treatment of atopic dermatitis is the drug which was made as the ointment. However, penetration rate of bufexamac was very low for the barrier effect of stratum corneum. Microneedle was used to increase transdermal delivery rate of the bufexamac. We tried to conjugate bufexamac and FITC for the detection of penetration rate of bufexamac. FITC-bufexamac was mixed in hydrogel for the treatment skin surface. Fluorescent spectrophotometer was used to analysis the concentration of FITC-bufexamac. Microscope using fluorescent filter was used to capture the image about location of FITC-bufexamac in the skin. We confirmed that permeation rate of bufexamac was increased with the treatment by microneedle and was increased by the increasing number treatment of microneedle.

Gene Expression Analysis of Hepatic Response Induced by Gentamicin in Mice

  • Oh, Jung-Hwa;Park, Han-Jin;Hwang, Ji-Yoon;Jeong, Sun-Young;Lim, Jung-Sun;Kim, Yong-Bum;Yoon, Seok-Joo
    • Molecular & Cellular Toxicology
    • /
    • v.3 no.1
    • /
    • pp.60-67
    • /
    • 2007
  • Gentamicin is a broad-spectrum aminoglycoside antibiotic used in the treatment of bacterial infection. Although side effects of gentamicin such as nephrotoxicity and ototoxicity have been investigated, the information on the hepatic effects of gentamicin is still limited. In the present study, gene expression profiles were analyzed in the liver of gentamicin treated mice using Affymetrix GeneChip$^{(R)}$ Mouse Expression 430A 2.0 Array. Totally, 400 genes were identified as being either up- or down-regulated over 1.5-fold changes (P<0.01) in the liver of gentamicin treated mice. Among these deregulated genes, 16 up-regulated genes mainly involved in transport (Kif5b, Pex14, Rab14, Clcn3, and Necap1) and 20 down-regulated genes involved in lipid and other metabolisms (Hdlbp, Gm2a, Uroc1, and Dak) were selected using k-means clustering algorithm. The functional classification of differentially expressed genes represented that several stress-related genes were regulated in the liver by gentamicin treatment. This data may contribute in understanding the molecular mechanism in the liver of gentamicin treated mice.

Increase in Color Depth and Analysis of the Interfacial Electrokinetic Potential of Poly(Ethylene Terephthalate) Fabric by Plasma Treatment (폴리에스테르 직물의 저온플라즈마 처리에 따른 계면동전위와 심색성 향상에 관한 연구)

  • Jeon, Sang-Min;Lee, Ki-Poong;Gu, Kang
    • Textile Coloration and Finishing
    • /
    • v.15 no.4
    • /
    • pp.1-7
    • /
    • 2003
  • We investigated the effect of color depth on polyester fabrics by plasma treatment. In this study, although it have many paper about effects of plasma treatment, we observed interfacial electrokinetic potential of polyester fabrics by plasma treatment and also we investigated relationship between deep coloring agent and plasma treatment to get the effect of color depth on polyester fabrics. The results obtained are as follows, 1. Plasma treatment did not enhanced the effect of color depth of polyester fabrics by plasma treatment independently. 2. In the case of using the deep coloring agent with plasma treatment on polyester fabrics, lightness was more decreased than using the deep coloring agent itself. 3. Plasma treatment could not affect surface shape and tensile strength of treated polyester fabrics.

$H_2$ plasma treatment effects on electrical and optical properties of the BZO (ZnO:B) thin films

  • Yoo, Ha-Jin;Son, Chan-Hee;Choi, Joon-Ho;Kang, Jung-Wook;Cho, Won-Tae;Park, Sang-Gi;Lee, Yong-Hyun;Choi, Eun-Ha;Cho, Guang-Sup;Kwon, Gi-Chung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.309-309
    • /
    • 2010
  • We have investigated the effect of $H_2$ plasma treatment on the BZO (ZnO:B, Boron doped ZnO) thin films. The BZO thin films are prepared by LP-MOCVD (Low Pressure Metal Organic Chemical Vapor Deposition) technique and the samples of BZO thin film are performed with $H_2$ plasma treatment by plasma treatment system with 13.56 MHz as RIE (Reactive Ion Etching) type. After exposing $H_2$ plasma treatment, measurement of transmittance, reflectance and haze spectra in 300~1100 nm, electrical properties as resistivity, mobility and carrier concentration and work function was analysed. Regarding the results of the $H_2$ plasma treatment on the BZO thin films are application to the TCO for solar cells, such as the a-Si thin films solar cell.

  • PDF

Programmed Follow-up and Quality Control of Treatment Techniques Enhance Chronic Thromboembolic Pulmonary Hypertension Management: Lessons From a Multidisciplinary Team

  • Taek Kyu Park;Sung-A Chang;Jeong Hoon Yang;Woochan Kwon;Min Yeong Kim;Young Seok Cho;Hye Yun Park;Dong Seop Jeong;Hojoong Kim;Duk kyung Kim
    • Korean Circulation Journal
    • /
    • v.54 no.7
    • /
    • pp.409-421
    • /
    • 2024
  • Background and Objectives: The recent developments in chronic thromboembolic pulmonary hypertension (CTEPH) are emphasizing the multidisciplinary team. We report on the changes in clinical practice following the development of a multidisciplinary team, based on our 7 years of experience. Methods: Multidisciplinary team was established in 2015 offering both balloon pulmonary angioplasty (BPA) and pulmonary endarterectomy (PEA) with technical upgrades by internal and external expertise. For operable cases, PEA was recommended as the primary treatment modality, followed by pulmonary angiography and right heart catheterization after 6 months to evaluate treatment effect and identify patients requiring further BPA. For patients with inoperable anatomy or high surgical risk, BPA was recommended as the initial treatment modality. Patient data and clinical outcomes were closely monitored. Results: The number of CTEPH treatments rapidly increased and postoperative survival improved after team development. Before the team, 38 patients were treated by PEA for 18 years; however, 125 patients were treated by PEA or BPA after the team for 7 years. The number of PEA performed was 64 and that of BPA 342 sessions. World Health Organization functional class I or II was achieved in 93% of patients. The patients treated with PEA was younger, male dominant, higher pulmonary artery pressure, and smaller cardiac index, than BPA-only patients. In-hospital death after PEA was only 1 case and none after BPA. Conclusions: The balanced development of BPA and PEA through a multidisciplinary team approach proved synergistic in increasing the number of actively treated CTEPH patients and improving clinical outcomes.

Effect of Cooling Rate on the Behavior of the Embrittlement in Zircaloy-4 Cladding (냉각속도가 지르칼로이-4 피복관의 취성에 미치는 영향)

  • Kim, Jun Hwan;Lee, Myoung Ho;Choi, Byoung Kwon;Jeong, Yong Hwan
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.18 no.2
    • /
    • pp.112-118
    • /
    • 2005
  • Study was focused on the effect of the cooling rate on the embrittlement behavior of Zircaloy-4 cladding simulated Loss Of Coolant Accident (LOCA) environment. Claddings were oxidized at given temperature and given time followed by various water quenching in the range of $0.6^{\circ}C$ and $100^{\circ}C$ per second. Cladding failed after water quenching above the threshold oxidation. Threshold oxidation was decreased as the cooling rate increased, which is due to the matensite structure formed during fast cooling rate.