• 제목/요약/키워드: system response

검색결과 13,106건 처리시간 0.037초

Rotordynamic Analysis and Experiment of Superconducting Magnetic Bearings-Flywheel System (초전도 자기베어링-플리이휠 시스템의 회전체 해서 및 실험)

  • Kim, Jong-Soo;Lee, Soo-Hun
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제16권9호
    • /
    • pp.104-109
    • /
    • 1999
  • The flywheel energy storage system using superconducting magnetic bearings is a device to store electrical energy as rotatioal kinetic energy by motor and to convert it to electrical energy by generator when it is necessary. The rotordynamic analysis should be performed with an adequate analytical model and equations of motion to identify the stable driving condition and the dynamic behavior. The critical speed and the unbalance response of superconducting magnetic bearings-flywheel system are studied in this paper. The analytical results show that the system has one forward whirling mode and two backward whirling models below 500rpm. The maximum displacement 0.75mm is detected at the first forward mode (385rpm)through unbalance response analysis. The analytical results are compared with the experimental result by the spin-down test. The experimental result shows that the maximum displacement is 0.7mm at 370rpm.

  • PDF

Harmonic Generation and System Response Characteristics in Electrified Railway(I) - Focused on System Response Characteristics - (전기철도에서의 고조파 발생과 계통응답특성(I) - 계통응답특성을 중심으로 -)

  • 오광해;이장무
    • Journal of the Korean Society for Railway
    • /
    • 제7권1호
    • /
    • pp.60-64
    • /
    • 2004
  • Harmonic current originating from electric locomotives can be magnified due to the impedance characteristics of power supply circuit and bring about various problems. That is, electromagnetic interference with communication lines, operational trouble in signaling, overheat and/or vibration in power capacitor, mis-operation in protection relay and so on. Therefore, the exact assessment of the harmonic current flow must be undertaken at design and planning stage for the electric traction systems. for these reasons, this study propose a new approach to model and to analyse traction power feeding system focused on system response to current and voltage harmonic(PART I). Measurements of harmonics are also performed for railway power supply systems under normal operation. Spectrum and distortion analyses in measurement data are variously described in PART II.

An Analysis of Seismic Response of High - Rise Building with Mid-Story Isolation System According to Change of Characteristics of the Seismic Isolation Device (중간층 면진시스템이 적용된 고층건물의 면진장치 특성변화에 따른 지진응답분석)

  • Kang, Joo-Won
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • 제35권8호
    • /
    • pp.149-156
    • /
    • 2019
  • In this study, dynamic responses of high - rise buildings were analyzed through the change of horizontal stiffness and yield strength among characteristics of seismic isolation system by applying middle - layer seismic isolation system to high - rise buildings of 120m height. As a result in order to prevent the displacement of the isolation layer and to control the maximum torsion angle, it is possible to appropriately control by increasing or decreasing the horizontal stiffness and the yield strength. However, depending on the maximum torsional angle and the hysteretic behavior of the seismic isolation system, excessive yield strength and horizontal stiffness increase may induce the elastic behavior of the structure and amplify the response. Therefore, it is considered that it is necessary to select the property value of the appropriate isolation device.

Performance Investigation of a Cylindrical Valve Featuring Electro-Rheological Fluids (전기유동유체를 이용한 실린더형 밸브의 성능 고찰)

  • Kim, K.S.;Jung, D.D.;Lee, H.J.;Choi, S.B.;Cheong, C.C.
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제11권4호
    • /
    • pp.148-157
    • /
    • 1994
  • A multi-cylindrical hydraulic valve incorporating with an electro-rheological(ER) fluid is developed in this study. Field-dependent Bingham properties of the ER fluid are exploited to devise the valve system which features fast system response as well as simple mechanism. The fast response is accrued from almost instant response characteristics of the ER fluid itself, and the mechanism configuration is simplified since no nechanically moving parts are required. The material properties of the ER fluids to be utilized for modeling of the proposed valve system are firstly tested with a couette-type electroviscometer. The design and manufacturing processes are then undertaken on the basis of model parameters. The performance characteristics of the valve system are evaluated in terms of pressure variations with respect to the intensity of employed electric fields and flow rates.

  • PDF

Performance Improvement of the Horizontal Control System for a Tractor Implement Using Sensor Signal from the Front Axle

  • Ro, Young-Min;Moon, Jun-Hee;Kim, Kyeong Uk
    • Journal of Biosystems Engineering
    • /
    • 제41권2호
    • /
    • pp.67-74
    • /
    • 2016
  • Purpose: Many tractors have adopted the horizontal control system designed to maintain the three-point mounted implements in horizontal position when they are tilted sideways. The control system rotates the implement in the opposite direction to the inclination of rear axle of the tractor. However, the current control system was found to have poor performance in accuracy and response. A new control system was therefore developed to improve the performance. Methods: The new control system was designed to get the response of the implement to be started earlier by using the tilt information from the front axle of the tractor. By this approach, the rotation of the implement can be adjusted as required to make it horizontal at the expected time, even though the response is slow. The optimal values of the control parameters for the new system were determined by computer simulation and validated by a performance test conducted with an obstacle of 120 mm height on a flat concrete surface. The performance of the control system was evaluated by the root mean square error (RMSE) of the rotation angle of the implement with respect to the actual inclination of the rear axle. Results: The new control system reduced the RMSE of the current control system by 44.6% indicating a high performance improvement. The inclination of the front axle was easily obtained from a sensor mounted on the front axle of the tractor and used as input to the new control system. Conclusions: The method of getting the response of the implement to be started earlier by utilizing the inclination information of the front axle can be applied to improve the performance of the current control system at least cost.

ON THE DYNAMICS OF PREDATOR-PREY MODELS WITH IVLEV'S FUNCTIONAL RESPONSE

  • RYU, KIMUN
    • Journal of the Chungcheong Mathematical Society
    • /
    • 제28권3호
    • /
    • pp.465-472
    • /
    • 2015
  • In this paper, we study the existence and the stability of equilibria of predator-prey models with Ivlev's functional response. We give a simple proof for the uniqueness of limit cycles of the predator-prey system. The existence and the stability at the origin and a boundary equilibrium point(including the positive equilibrium point) are also investigated.

Leak Detection of Circular Piping Systems by Using Unit Impulse Response Function Analysis (단위 충격 응답함수를 이용한 원형관 시스템의 주출감지 연구)

  • 전오성;윤병옥;김창호
    • Journal of KSNVE
    • /
    • 제4권3호
    • /
    • pp.337-343
    • /
    • 1994
  • A method of the leak detection from the pipe system by using accelerometer is proposed. The signal detected from accelerometer is proved experimentally to be a dispersive wave. Based on the experiments, a method using the narrow band pass filter and the unit impulse response function is analyzed. The method uses the characteristics of the unit impulse response function, that the function is available evenin the narrow band signal because, unlike the cross correlation, it is normalized by the auto spectrum. The accelerometer is quite easier to use than the hydrophone in adapting to the pipe system.

  • PDF

Assessment of the Generators Constant from Frequency Response Properties of Korean Power System (우리나라 계통의 주파수응답특성에 의한 발전기정수 산정에 관한 연구)

  • Jeong, Bong-Sang;Chun, Yeong-Han;Kim, Il-Dong;Yang, Jeong-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제58권4호
    • /
    • pp.688-693
    • /
    • 2009
  • The response characteristics of power system frequency are determined by generator droop characteristics and load damping properties. The characteristics of governor droops are termed by generators constant, while those of load damping by load constant. In this paper, the generator constant and the load constant are assessed by measured data at the event of generator trips.

Effects of Carrier Wave on the Brain Stem Electric Response (BER) in Scala Tympanic Electrode Array

  • Duck-Hwann Lim;Byu
    • Journal of Biomedical Engineering Research
    • /
    • 제3권2호
    • /
    • pp.105-112
    • /
    • 1982
  • Using electronic cochlear implant system, we studied in cats the difference in the response of the brain stem evoked response (BER) during the stimulation with the acoustic signals and the electric signals. These brain stem electric responses were analyzed using the integral pulse frequency modulation method of the auditory nervous system. Animal experimental results and the analysis show that the carrier wave hasimprored the frequency specificity. of the electronic auditory prosthesis.

  • PDF

Control Methodology of Inverse Response Process

  • Pratch, Tontirittiphol;Kiattisak, Kumwachara;Mongkol, Janchookiat
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.48.6-48
    • /
    • 2002
  • in this paper, each methodology, e.g. normal single PID controller, direct synthesis method and inverse response compensator, will be compared to determine the best inverse response plant control method, by based on the appearance of the control performance and robustness from the simulation results. The flexibility of being able to maintain the system stability during the presence of plant model mismatch is one of the criteria to measure the robustness of overall control system. Once, plant has changed the condition, the model will need to be updated. Hence, the designed controller will not work properly. The caused of plant model mismatch is stayed by definition unknown but the most possib...

  • PDF