• Title/Summary/Keyword: system evaluation

Search Result 20,744, Processing Time 0.062 seconds

Antioxidant activities of Citrus junos seed shell extract and fractions cultivated in Korea (국내산 유자씨박 (Citrus junos seed shell) 추출물 및 분획물의 항산화 활성 평가)

  • Kim, A Young;Jeong, Hyo Jin;Park, Soo Nam
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.236-243
    • /
    • 2017
  • In the present study, 70% ethanol extract, the ethyl acetate fraction were prepared from citron (Citrus junos)seed and their antioxidative ability was evaluated. The yields of extract and fractions were 5.1 and 0.9% per dried powder, respectively. In the 1,1-Phenyl-2-picrylhydrazyl (DPPH) radical test, free radical scavenging activities ($FSC_{50}$) of 70 % ethanol extract, ethyl acetate fraction were 512.1 and $514.0{\mu}g/mL$, respectively. Evaluation of total antioxidant capacities ($OSC_{50}$) using $Fe^{3+}$-EDTA system. Their $OSC_{50}$ of ethyl acetate fraction were $86.5{\mu}g/mL$. this antioxidant capacities higher than that of 70% ethanol extract. but lower than that of L-ascorbic acid ($1.72{\mu}g/mL$), known as a prominent water soluble antioxidant. The cellular protective effects on the $^1O_2$-induced cellular damage of rabbit erythrocytes were evaluated and the results showed that the extract was lower than (+)-${\alpha}$-tocopherol and low concentration of ethyl acetate fraction was similar to (+)-${\alpha}$-tocopherol. but not at high concentrations of ethtyl acetate fraction. it was able to induce cellular damage at high concentration.

Domestic and International Experts' Perception of Policy and Direction on STEAM Education (융합인재교육(STEAM)의 정책과 실행 방향에 대한 국내외 전문가들의 인식)

  • Jung, Jaehwa;Jeon, Jaedon;Lee, Hyonyong
    • Journal of Science Education
    • /
    • v.39 no.3
    • /
    • pp.358-375
    • /
    • 2015
  • The purposes of this study were to investigate the value, necessity and legitimacy of STEAM Education and to propose practical approaching methods for STEAM Education to be applicable in Korea through a variety of literature review, case studies and collecting suggestions from domestic and international educational experts. The research questions are as follows: (1) To investigate the perception, understanding and recognitions of domestic and foreign professionals in STEAM education. (2) To analyze policy implications for an improvement in STEAM. The following aspects of STEAM were found to be challenges in our current STEAM policy after analyzing multiple questionnaires with the professionals and case studies including their experiences, understanding, supports and directions of the policy from the governments. The results indicate that (1) there was a lack of precise and conceptual understanding of STEAM in respect to experience. Training sessions for teachers in this field to help transform their perception is necessary. Development of practical programs with an easy access is also required. It is important to get the aims of related educational activities recognized by the professionals and established standards for an evaluation. The experts perceived that a theme-based learning is the most preferred and effective approaching method and the programs that develop creative thinking and learning applicable to practice are required to promote. (2) The results indicate that there was a lack of programs and inducements for supporting outstanding STEAM educators. It is shown that making an appropriate environment for STEAM education takes the first priority before training numbers of teachers unilaterally, thus securing enough budget seems critical. The professionals also emphasize on developing specialized teaching materials that include diverse inter-related subjects such as science technology, engineering, arts and humanities and social science with diverse viewpoints and advanced technology. This work requires a STEAM network for teachers to link up and share their materials, documents and experiences. It is necessary to get corporations, universities, and research centers participated in the network. (3) With respect to direction, it is necessary to propose policy that makes STEAM education ordinary and more practical in the present education system. The professionals have recommended training sessions that help develop creative thinking and amalgamative problem-solving techniques. They require reducing the workload of teachers and changing teachers' perspectives towards STEAM. They further urge a tight cooperation between departments of the government related with STEAM.

  • PDF

Anti-Melanogenic, Anti-Wrinkle, Anti-Inflammatory and Anti-Oxidant Effects of Xylosma congesta leaf Ethanol Extract (산유자 잎 에탄올 추출물의 미백, 주름억제, 항염증 및 항산화 효능)

  • Lee, Jae Yeon;Ahn, Eun-Kyung;Ko, Hye-Jin;Cho, Young-Rak;Ko, Woon Chul;Jung, Yong-Hwan;Choi, Kyung-Min;Choi, Mi-Rae;Oh, Joa Sub
    • Journal of Applied Biological Chemistry
    • /
    • v.57 no.4
    • /
    • pp.365-371
    • /
    • 2014
  • In the present study, we investigated the biological activities of Xylosma congesta leaf ethanol extract (XCO) using a variety of in vitro and cell culture model systems for anti-melanogenic, anti-wrinkle, anti-inflammatory and anti-oxidant activities. First, XCO markedly inhibited ${\alpha}$-melanocyte stimulating hormone-stimulated melanin synthesis in B16F10 cells. Secondly, XCO marginally induced procollagen synthesis in CCD-986SK cells. Thirdly, XCO dose-dependently suppressed lipopolysaccharide-induced nitric oxide (NO) production in RAW 264.7 cells. XCO did not affect cell viability at different concentrations used in this study, indicating that XCO-mediated inhibition of melanin, procollagen and NO synthesis is not mediated by cytotoxicity. Finally, XCO was found to exert anti-oxidant effect. Taken together, these findings demonstrate for the first time that XCO possesses anti-melanogenic, anti-wrinkle, anti-inflammatory and anti-oxidant activities, and suggest further evaluation and development of XCO as a functional supplement or cosmetic that may be useful for whitening skin, reducing wrinkles and treating inflammatory responses.

Oil Production Evaluation for Hybrid Method of Low-Salinity Water and Polymer in Carbonate Oil Reservoir (탄산염암 저류층에 저염수주입공법과 폴리머공법의 복합 적용에 따른 오일 생산량 평가)

  • Lee, Yeonkyeong;Kim, Sooyeon;Lee, Wonsuk;Jang, Youngho;Sung, Wonmo
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.5
    • /
    • pp.53-61
    • /
    • 2018
  • Low-salinity water based polymerflooding (LSPF) is one of promising enhanced oil recovery (EOR) method that has the synergetic effect of combining polymer injection method and low-salinity water injection method. In order to maximize EOR efficiency, it is essential to design low-salinity water appropriately considering the properties of polymer. In this aspect, the main purpose of this study is to investigate the effect of pH and $SO_4{^{2-}}$ ion which one of PDI (Potential Determining Ion) on oil production when applying LSPF to carbonate oil reservoir. First, the stability and adsorption of polymer molecule were analyzed in different pH of injection water and $SO_4{^{2-}}$ concentration in injection water. As a result, regardless of pH and $SO_4{^{2-}}$ concentration, when $SO_4{^{2-}}$ ion was contained in injection water, the stability of polymer solution was obtained. However, from the result of polymer retention analysis, in neutral state of injection water, since $SO_4{^{2-}}$ interfered the adsorption of polymer, the adsorption thickness of polymer was thinner as $SO_4{^{2-}}$ concentration was higher. On the other hand, when injection water was acidic as pH 4, the amount of polymer adsorption increased with the injection of polymer solution, so the mobility of polymer solution was greatly lowered. From the results of wettability alteration due to low-salinity water effect, in the case of neutral injection water injected, as $SO_4{^{2-}}$ concentration was increased, more oil which attached on rock surface was detached, altering wettability from oil-wet to water-wet. On the other hand, in acidic condition, due to complex effect of rock dissolution and polymer adsorption, wettability of the entire core system was less altered relatively to neutral condition. Therefore, it was evaluated that better EOR efficiency was obtained when injecting low-salinity water based polymer solution containing high concentration of $SO_4{^{2-}}$ with neutral condition, enhancing the oil production up to 12.3% compared to low-salinity water injection method.

The nanoleakage patterns of experimental hydrophobic adhesives after load cycling (Load cycling에 따른 소수성 실험용 상아질 접착제의 nanoleakage 양상)

  • Sohn, Suh-Jin;Chang, Ju-Hae;Kang, Suk-Ho;Yoo, Hyun-Mi;Cho, Byeong-Hoon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.1
    • /
    • pp.9-19
    • /
    • 2008
  • The purpose of this study was: (1) to compare nanoleakage patterns of a conventional 3-step etch and rinse adhesive system and two experimental hydrophobic adhesive systems and (2) to investigate the change of the nanoleakage patterns after load cycling. Two kinds of hydrophobic experimental adhesives, ethanol containing adhesive (EA) and methanol containing adhesive (MA), were prepared. Thirty extracted human molars were embedded in resin blocks and occlusal thirds of the crowns were removed. The polished dentin surfaces were etched with a 35 % phosphoric acid etching gel and rinsed with water. Scotchbond Multi-Purpose (MP), EA and MA were used for bonding procedure. Z-250 composite resin was built-up on the adhesive-treated surfaces. Five teeth of each dentin adhesive group were subjected to mechanical load cycling. The teeth were sectioned into 2 mm thick slabs and then stained with 50 % ammoniacal silver nitrate. Ten specimens for each group were examined under scanning electron microscope in backscattering electron mode. All photographs were analyzed using image analysis software. Three regions of each specimen were used for evaluation of the silver uptake within the hybrid layer. The area of silver deposition was calculated and expressed in gray value. Data were statistically analyzed by two-way ANOVA and post-hoc testing of multiple comparisons was done with the Scheffe's test. Silver particles were observed in all the groups. However, silver particles were more sparsely distributed in the EA group and the MA group than in the MP group (p < .0001). There were no changes in nanoleakage patterns after load cycling.

EVALUATION OF THE INFLUENCE OF APICAL SIZES ON THE APICAL SEALING ABILITY OF THE MODIFIED CONTINUOUS WAVE TECHNIQUE (Modified Continuous Wave Technique을 이용한 근관충전시 형성된 치근단 크기가 치근단 폐쇄에 미치는 영향)

  • Ryu, Mu-Hyun;Jung, Il-Young;Lee, Seung-Jong;Shin, Su-Jung;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.1
    • /
    • pp.66-75
    • /
    • 2008
  • This study examined the influence of the apical sizes on the sealing ability of a root canal filling. Thirty-six single rooted teeth with a single canal were divided into 3 groups (n = 12) and instrumented with either the $Profile^{(R)}$ or $LightSpeed^{(R)}$ system to achieve three different apical sizes (master apical file [MAF] of #25, #40, or #60). The teeth were filled with gutta perch a using a modified continuous wave technique. The level of microleakage was determined by immersing ten teeth from each group into India ink for 1 week followed by clearing with nitric acid, ethyl-alcohol, and methylsalicylate. The microleakage was measured using vernier calipers. The data was analyzed statistically using Kruskal-Wallis one-way ANOVA and a Student-Newman-Keuls Method. Two teeth from each group were sectioned horizontally at 1, 2, 3 and 4 mm from the apex in order to observe a cross section. The apical size was significantly (p < .05) influenced the level of microleakage. In the Student-Newman-Deuls Method, MAF sizes of #25 and #40; and MAF sizes of #25 and #60, respectively showed a statistically significant difference. There was no significant difference between #40 and #60. In most cross sections, oval-shaped canals were observed, and the irregularity of the internal surface increased with decreasing apical size. There was also an increase in the area of recess, which is the area where the canal space is not filled with either gutta-percha or sealer. When the root canals are filled using a modified continuous wave technique, canal filling with more consistent and predictable outcome may be expected as the apical preparation size is increased.

Comparison of Quality Characteristics of Sesame leaf Cleaned with Various Electrolyzed Water during Storage (다양한 전기분해수 세정처리에 따른 깻잎의 저장중 품질특성 비교)

  • Jeong Jin-Woong;Kim Jong-Hoon;Kwon Kee-Hyun
    • Food Science and Preservation
    • /
    • v.12 no.6
    • /
    • pp.558-564
    • /
    • 2005
  • This study was carried out to investigate the cleaning effect of sesame leaf, the sterilization effect and physicochemical properties, treated with various electrolyzed water. Initial physicochemical properties could be kept more than 1 month in electrolyzed oxidizing water(EW-1) of diaphragm type and 15 days in electrolyzed water(EW-2 and EW-3) of non-diaphragm system, there was no significant difference by storage temperature. 4 kinds of microorganism (initial total counts, $10^7\~10^9$ CFU/mL) were sterilized within $0.5\~1$ minutes by electrolyzed water. In fresh sesame leaves, total viable cell count and coliform group in the treatment of electolyzed water were decreased to about $2\~3$ log scale comparing non-treated ones. Especially Bacillus cereus was not detected until 13th day when treated with EW-l. Decaying ratio of sesame leaf appears on day 6 of storage in the untreated but the treatments of electrolyzed water has no sign until day 10 of storage. Change in color difference(${\Delta}E$) during storage was observed the treatments of electrolyzed low-alkaline water(EW-2) and electrolyzed neutral water(EW-3) were very desirable at the level $1\~2$ after day 13 of storage comparative to the untreated Change of Chlorophyll content was biggest decreased to 6.8 $mg\%$ on the untreated and decreased least to 8.35 $mg\%$ on EW-3 treated group on 13th day from initial value of $9.0\~10.3\;mg\%$ The overall sensory evaluation appeared most acceptable in the treatments of EW-2 and EW-3.

The Effect of the Axial Plane on Measurement of Available Bone Height for Dental Implant in Computed Tomography of the Mandible (하악의 전산화 단층사진에서 횡단면이 임플랜트를 위한 가용골 높이의 결정에 미치는 영향)

  • Jhin, Min-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.2
    • /
    • pp.379-388
    • /
    • 2002
  • For the success of dental implant, accurate radiographic evaluation is prerequisite for planning the location of the osseointegrated implants and avoiding injury to vital structures. CT/MPR(computed tomography/multiplanar reformation) shows improved visualization of inferior alveolar canal. In order to obtain cross-sectional images parallel to the teeth, the occlusal plane is used to orientate for the axial plane. If the direction of axial plane is not parallel to the occlusal plane, the reformatted cross-sectional scans will be oblique to the planned fixture direction and will not show the actual dimension of the planned fixture's location. If the available bone height which measured in the cross-sectional view is much greater than the actual available bone height, penetration of canal may occur. The aim of this study is to assess the effect of the axial plane to measurement of available bone height for dental implant in computed tomography of the mandible. 40 patients who had made radiographic stents and had taken CT were selected. The sites that were included in the study were 45 molar regions. In the central panoramic scan, the length from alveolar crest to superior border of inferior alveolar canal(available bone height, ABH) was measured in direction of reformatted cross-sectional plane(uncorrected ABH). Then, length from alveolar crest to superior border of canal was measured in direction of stent(corrected ABH). The angle between uncorrected ABH and corrected ABH was measured. From each ABH, available fixture length was decided by $Br{{\aa}}nemark$ system. The results were following ; the difference between two ABHs was statistically significant in both first and second molar(p< 0.01). The percentage of difference more than 1 mm was 8.7% in first molar and 15.5% in second molar. The percentage of difference more than 2 mm was 2.0% in first molar and 6.6% in second molar. The maximum value of difference was 2.5 mm in first molar and 2.2 mm in second molar. The correlations between difference of 2 ABHs and angle was positive correlations in both first and second molar. The correlation coefficient was 0.534 in first molar and 0.728 in second molar. The second molar has a stronger positive correlation. The percentage of disagreement between 2 fixture lengths from two ABHs was 24.4% in first molar and 28.9% in second molar.

Performance Test of Portable Hand-Held HPGe Detector Prototype for Safeguard Inspection (안전조치 사찰을 위한 휴대형 HPGe 검출기 시제품 성능평가 실험)

  • Kwak, Sung-Woo;Ahn, Gil Hoon;Park, Iljin;Ham, Young Soo;Dreyer, Jonathan
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.54-60
    • /
    • 2014
  • IAEA has employed various types of radiation detectors - HPGe, NaI, CZT - for accountancy of nuclear material. Among them, HPGe has been mainly used in verification activities required for high accuracy. Due to its essential cooling component(a liquid-nitrogen cooling or a mechanical cooling system), it is large and heavy and needs long cooling time before use. New hand-held portable HPGe has been developed to address such problems. This paper deals with results of performance evaluation test of the new hand-held portable HPGe prototype which was used during IAEA's inspection activities. Radioactive spectra obtained with the new portable HPGe showed different characteristics depending on types and enrichments of nuclear materials inspected. Also, Gamma-rays from daughter radioisotopes in the decay series of $^{235}U$ and $^{238}U$ and characteristic x-rays from uranium were able to be remarkably separated from other peaks in the spectra. A relative error of enrichment measured by the new portable HPGe was in the range of 9 to 27%. The enrichment measurement results didn't meet partially requirement of IAEA because of a small size of a radiation sensing material. This problem might be solved through a further study. This paper discusses how to determine enrichment of nuclear material as well as how to apply the new hand-held portable HPGe to safeguard inspection. There have been few papers to deal with IAEA inspection activity in Korea to verify accountancy of nuclear material in national nuclear facilities. This paper would contribute to analyzing results of safeguards inspection. Also, it is expected that things discussed about further improvement of a radiation detector would make contribution to development of a radiation detector in the related field.

Inspiratory Flow Rate for the Evaluation of Bronchodilator in Patients with COPD (만성폐쇄성폐질환 환자에서 기관지확장제 흡입에 대한 흡기환기지표의 반응)

  • Baik, Jae-Joong;Park, Keon-Uk;Chung, Yeon-Tae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.3
    • /
    • pp.342-350
    • /
    • 1995
  • Background: Although there are improvements of clinical symtoms after bronchodilator inhalation in COPD patients, it has been noted that there was no increase of $FEV_1$ in some cases. $FEV_1$ did not reflect precisely the improvement of ventilatory mechanics after bronchodilator inhalation in these COPD patients. The main pathophysiology of COPD is obstruction of airway in expiratory phase but in result, the load of respiratory system is increased in inspiratory phase. Therefore the improvement of clinical symptoms after bronchodilator inhalation may be due to the decrease of inspiratory load. So we performed the study which investigated the effect of bronchodilator on inspiratory response of vetilatory mechanics in COPD patients. Methods: In 17 stable COPD patients, inspiratory and expiratory forced flow-volume curves were measured respectively before bronchodilator inhalation. 10mg of salbutamol solution was inhaled via jet nebulizer for 4 minutes. Forced expiratory and inspiratory flow-volume curves were measured again 15 minutes after bronchodilator inhalation. Results: $FEV_1$, FVC and $FEV_1$/FVC% were $0.92{\pm}0.34L$($38.3{\pm}14.9%$ predicted), $2.5{\pm}0.81L$($71.1{\pm}21.0%$ predicted) and $43.1{\pm}14.5%$ respectively before bronchodilator inhalation. The values of increase of $FEV_1$, FVC and PIF(Peak Inspiratory Flow) were $0.15{\pm}0.13L$(relative increase: 17.0%), $0.58{\pm}0.38\;L$(29.0%) and $1.0{\pm}0.56L$/sec(37.5%) respectively after bronchodilator inhalation. The increase of PIF was twice more than $FEV_1$ in average(p<0.001). The increase of PIF in these patients whose $FEV_1$ was not increased after bronchodilator inhalation were 35.0%, 44.0% and 55.5% respectively. Conclusion: The inspiratory parameter reflected improvement of ventilatory mechanics by inhaled bronchodilater better than expiratory parameters in COPD patients.

  • PDF