Browse > Article
http://dx.doi.org/10.14407/jrp.2014.39.1.054

Performance Test of Portable Hand-Held HPGe Detector Prototype for Safeguard Inspection  

Kwak, Sung-Woo (Korea Institute of Nuclear Nonproliferation and Control)
Ahn, Gil Hoon (Korea Institute of Nuclear Nonproliferation and Control)
Park, Iljin (Korea Institute of Nuclear Nonproliferation and Control)
Ham, Young Soo (Lawrence Livermore National Laboratory)
Dreyer, Jonathan (Lawrence Livermore National Laboratory)
Publication Information
Journal of Radiation Protection and Research / v.39, no.1, 2014 , pp. 54-60 More about this Journal
Abstract
IAEA has employed various types of radiation detectors - HPGe, NaI, CZT - for accountancy of nuclear material. Among them, HPGe has been mainly used in verification activities required for high accuracy. Due to its essential cooling component(a liquid-nitrogen cooling or a mechanical cooling system), it is large and heavy and needs long cooling time before use. New hand-held portable HPGe has been developed to address such problems. This paper deals with results of performance evaluation test of the new hand-held portable HPGe prototype which was used during IAEA's inspection activities. Radioactive spectra obtained with the new portable HPGe showed different characteristics depending on types and enrichments of nuclear materials inspected. Also, Gamma-rays from daughter radioisotopes in the decay series of $^{235}U$ and $^{238}U$ and characteristic x-rays from uranium were able to be remarkably separated from other peaks in the spectra. A relative error of enrichment measured by the new portable HPGe was in the range of 9 to 27%. The enrichment measurement results didn't meet partially requirement of IAEA because of a small size of a radiation sensing material. This problem might be solved through a further study. This paper discusses how to determine enrichment of nuclear material as well as how to apply the new hand-held portable HPGe to safeguard inspection. There have been few papers to deal with IAEA inspection activity in Korea to verify accountancy of nuclear material in national nuclear facilities. This paper would contribute to analyzing results of safeguards inspection. Also, it is expected that things discussed about further improvement of a radiation detector would make contribution to development of a radiation detector in the related field.
Keywords
Portable HPGe detector; Nuclear material; Safeguard inspection; Nuclear non-proliferation; Uranium; Enrichment;
Citations & Related Records
연도 인용수 순위
  • Reference
1 J. Dreyer, M. Burks, Spectroscopic portable germanium (SPG) user guide. LLNL-TM-639382. LLNL. 2013:3-5.
2 최관규, 김재광, 김정수, 김종숙, 서형민, 이나영, 이혜영, 임동혁, 장성순, 정진호, 조성연, 태재웅, 형상철, 원자력통제:안전조치.수출입통제.물리적방호 별책부록. 한국원자력통제기술원. 2013:132-139.
3 Safeguards Manual : Accountancy Verification Methods and C/S Measures. SMI 4.5 Annex 3. IAEA. 2003.
4 Delynn Clark, U235:A gamma ray analysis code for uranium isotope determination. UCRL-ID-125727. LLNL. 1996:3-7.
5 ORTEC, MGA++ V1.06 Safeguards Software (http://www.ortec-online.com).
6 최관규, 김재광, 김정수, 김종숙, 서형민, 이나영, 이혜영, 임동혁, 장성순, 정진호, 조성연, 태재웅, 형상철. 원자력통제:안전조치.수출입통제.물리적방호. 한국원자력통제기술원. 2013:103.