• 제목/요약/키워드: surface plasmon resonance (SPR) sensor

검색결과 54건 처리시간 0.026초

SK 지수를 이용한 표면 플라즈몬 공명 바이오 센서의 측정방법의 분류 (Classification of Measurement Methods of Surface Plasmon Resonance Biosensors by SK Index)

  • 이승기
    • 센서학회지
    • /
    • 제13권5호
    • /
    • pp.342-349
    • /
    • 2004
  • SK (SPR Kinds) index, which can categorize the complicated measurement methods of surface plasmon resonance by simple method, has been proposed and verified. SK index is composed of three digits, where each digit presents the type of immobilized ligand, the type of illumination and the kinds of varying parameter, sequentially. The measurement method of (33#) series among SK indices shows the possibility of the multi-sensing capability, by which the response of 2-dimensional array of immobilized ligands can be detected simultaneously. The proposed possibility of multi-sensing capability has been verified by the modeling that is based on Fresnel reflection model.

폴리스티렌 나노 비드를 이용한 플라즈모닉 나노 구조체의 광학 특성 (Optical Characteristics of Plasmonic Nano-structure Using Polystyrene Nano-beads)

  • 김두근;정병규;김홍승;김태룡;김선훈;기현철;김태언;신재철;최영완
    • 한국전기전자재료학회논문지
    • /
    • 제28권4호
    • /
    • pp.244-248
    • /
    • 2015
  • We proposed and demonstrated the double layered metallic nano-hole structure using polystyrene beads process to enhance the sensitivity of surface plasmon resonance (SPR). The double layered SPR structures are calculated using the finite-difference time-domain (FDTD) method for the width, thickness, and period of the metallic nano-hole structures. The thickness of the metal film and the metallic nano-hole is 30 and 20 nm in the 214 nm wide nano-hole size, respectively. The double layered SPR structures are fabricated with monolayer polystyrene beads of 420 nm wide. The sensitivities of the conventional SPR sensor and the double layered SPR sensor are obtained to 42.2 and 52.1 degree/RIU, respectively.

Development of SPR Gas Sensor for Small Molecules Using Molecularly Imprinted Polymer Thin Films

  • 장성우;진성일;박찬량
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.242.2-242.2
    • /
    • 2011
  • Molecularly imprinted polymer thin films were applied to develop a gas sensor based on the surface plasmon resonance phenomenon for small gaseous molecules such as toluene and xylene. The imprinted polymer films were synthesized via photo-polymerization method using various combination of templates, functional monomers and cross-linkers. The temperature of pre-polymerization solutions and the power of UV light were controlled for optimized performance of gas sensing. The morphology and porosity of the polymer films were controlled by varying the mixing ratios of the pre-polymerization solutions and confirmed by atomic force microscopy. By fitting the adsorption/desorption sensorgrams to conventional kinetic models, the effects of different templates and cross-linkers were interpreted in term of the structural differences of the polymer networks formed on the gold film. The sensitivity and selectivity of sensors were estimated for toluene and xylene, and also for humidity and other gaseous molecules such as formaldehyde and ammonia.

  • PDF

Immunoaffinity Characteristics of Exosomes from Breast Cancer Cells Using Surface Plasmon Resonance Spectroscopy

  • Sohn, Young-Soo;Na, Wonhwi;Jang, Dae-Ho
    • 센서학회지
    • /
    • 제28권6호
    • /
    • pp.355-359
    • /
    • 2019
  • Exosomes, known as nanoscale extracellular vesicles in the range of 30-150 nm, are known to contain clinically significant information. However, there is still insufficient information on exosomal membrane proteins for cancer diagnosis. In this work, we investigated the characteristics of the membrane proteins of exosomes shed by cultured breast cancer cell lines using a surface plasmon resonance (SPR) spectroscopy and pre-activated alkanethiols modified sensor chips. The antibodies of breast cancer biomarkers such as MCU-16, EpCAM, CD24, ErbB2, and CA19-9 were immobilized on the pre-activated alkanethiols surfaces without any activation steps. The purified exosomes were loaded onto each antibody surface. The affinity rank of the antibody surfaces was decided by the relative capture efficiency factors for the exosomes. In addition, an antibody with a relative capture efficiency close to 100% was tested with exosome concentration levels of 104/µl, 105/µl, and 106/µl for quantitative analysis.

반사광 측정 모드에서 금과 은을 사용한 이층 금속 칩과 삼층 금속 칩의 특성 연구 (Characteristics of Gold and Silver Based Bi- and Tri-metallic SPR Chip in the Intensity Measurement Mode)

  • 김형진;김창득;손영수
    • 센서학회지
    • /
    • 제25권2호
    • /
    • pp.143-147
    • /
    • 2016
  • Characteristics of the conventional gold (Au) surface plasmon resonance (SPR) chip, bi-metallic(Au/silver (Ag)) SPR chip, and tri-metallic(Au/Ag/Au) SPR chip were investigated and compared in the intensity measurement mode for the enhancement of SPR image sensor reactivity. Reflectance curves of the Au, bi- and tri-metallic SPR chips were acquired in phosphate-buffered saline (PBS) solution and were compared. The line width of the reflectance curve of the bi-metallic chip was the narrowest among the three different types of the chips. Also, the tangential slope of the bi-metallic chip was steeper than those of the other chips. Various concentrations of bovine serum albumin (BSA) were utilized in the SPR experiment. As a result, among the above three chips reflectance variation value of the bi-metallic chip was the largest.

플라즈모닉스 현상을 이용한 전반사 기반 다층 유전체 박막 센서의 특성 분석 (Characteristics Analysis of Total Internal Reflection-based Dielectric Multi-layer Sensor Using Plasmonics Phenomena)

  • 김홍승;이태경;김두근;정유라;오금윤;이병현;기현철;최영완
    • 한국전기전자재료학회논문지
    • /
    • 제25권7호
    • /
    • pp.516-520
    • /
    • 2012
  • In this paper, we have theoretically analyzed and designed a dielectric multi-layer sensor with a SPR (surface plasmon resonance) using analytical calculation and FDTD (finite difference time-domain) methods. The proposed structure is composed of periodic layer and thin metal film. It has many advantages. One of that is a high sensitivity of the SPR. Another is a high Q-factor of the characteristics in the PhC (photonic crystals) micro-cavity structure. The incident light has double resonance characteristics, because the filtered light by PhC structure, dielectric multi-layer, is met the thin metal film for SPR effect. We have also observed the change of resonance characteristics according to the variation of effective index on the metal film.

회절격자가 집적된 일회용 다중채널 SPR 생체분자 검출 칩 (A Disposable Grating-Integrated Multi-channel SPR Sensor Chip for Detection of Biomolecule)

  • 진영현;조영호
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.147-154
    • /
    • 2009
  • This paper presents a grating~integrated SPR (Surface Plasmon Resonance) sensor chip for simple and inexpensive biomolecule detection. The grating-integrated SPR sensor chip has two sensing channels having a nano grating for SPR coupling. An external mirror is used for multi channel SPR sensing. The present sensor chip replaces bulky and expensive optical components, such as fiber-optic switches or special shaped prisms, resulting in a simple and inexpensive wavelength modulated multi-channel SPR sensing system. We fabricate a SPR sensor chip integrated with 835 nm-pitch gratings by a micromolding technique to reduce the fabrication cost. In the experimental characterization, the refractive index sensitivity of each sensing channel is measured as $321.8{\pm}8.1nm$/RI and $514.3{\pm}8.lnm$/RI, respectively. 0.5uM of the target biomolecule (streptavidin) was detected by a $1.13{\pm}0.16nm$ shift of the SPR dip in the 10%-biotinylated sample channel, while the SPR dip in the reference channel for environmental perturbation monitoring remained at the same position. From the experimental results, multi-channel biomolecule detection capability of the present grating-integrated SPR sensor chip has been verified. On the basis of the preliminary experiments, we successfully measured the binding reaction rate for the $2\;nM{\sim}200\;nM$ monoclonal-antibiotin, thus verifying biomolecule concentration detectability of the present SPR sensor chip. The binding reaction rates measured from the present SPR sensor chip agredd well with those from a commercialized SPR sensor.

폐암 바이오마커 검출용 나노SPR 바이오센서 (Nano SPR Biosensor for Detecting Lung Cancer-Specific Biomarker)

  • 장은윤;염세혁;엄년식;한정현;김형경;신용범;강신원
    • 센서학회지
    • /
    • 제22권2호
    • /
    • pp.144-149
    • /
    • 2013
  • In this research, we developed a biosensor to detect lung cancer-specific biomarker using Anodic Aluminum Oxide (AAO) chip based on interference and nano surface plasmon resonance (nanoSPR). The nano-porous AAO chip was fabricated $2{\mu}m$ of pore-depth by two-step anodizing method for surface uniformity. NanoSPR has sensitivity to the refractive index (RI) of the surrounding medium and also provides simple and label-free detection when specific antibodies are immobilized to the Au-deposited surface of nano-porous AAO chip. To detect the lung cancer-specific biomarker, antibodies were immobilized on the surface of the chip by Self Assembled Monolayer (SAM) method. Since then lung cancer-specific biomarker was applied atop the antibodies immobilized layer. The specific reaction of the antigen-antibody contributed to the change in the refractive index that cause shift of resonance spectrum in the interference pattern. The Limit of Detection (LOD) was 1 fg/ml by using our nano-porous AAO biosensor chip.

나노형상을 가진 표면플라즈몬공명 센서칩의 감도 개선 효과 (Effect of SPR Chip with Nano-structured Surface on Sensitivity in SPR Sensor)

  • 조용진;김철진;김남수;김종태;김태은;김효섭;김재호
    • 산업식품공학
    • /
    • 제14권1호
    • /
    • pp.49-53
    • /
    • 2010
  • 표면 플라즈몬 공명을 이용한 센서는 굴절계 기기의 일종으로서 높은 감도를 가질 뿐만 아니라 비표지 방식이라는 장점을 가지고 있다. 본 연구에서는 재래식 SPR 칩을 이용하여 시판 술 4종의 알코올 함량을 측정하였다. 또한, 재래식 SPR 칩의 감도를 개선하기 위하여 금 박막 위에 금으로 나노형상을 구축하여 나노형상 SPR 칩을 제조하여 모형 술에 대한 감도 개선 효과를 분석하였다. 재래식 SPR 칩을 이용하여 시판 술의 알코올 함량을 측정하기 위한 검량선을 개발하였을 때 시료를 전처리 하지 않고 그대로 측정하였을 때 가장 좋은 검량선을 얻을 수 있었다. 소주, 청주, 이과두주, 탁주 등 시판 술 4종에 대한 1차 회귀식의 검량식에서 결정계수는 각각 0.992, 0.933, 0.918, 그리고 0.984로 나타났다. 한편, 재래식 SPR 칩의 감도를 개선하기 위해 나노형상 SPR 칩을 제조하기 위하여 Langmuir-Blodgett(LB) 방법을 활용하였다. 본 연구에서는 수십 nm 두께의 금 박막을 바닥층으로 하여 그 위에 나노 크기의 실리카 입자를 단분자 층으로 덮어 형틀을 제조하고 다시 그 위에 금을 증착한 후 실리카 입자를 제거하는 방법으로 나노형상을 갖는 SPR 칩을 제조하였다. 나노형상 SPR 칩의 성능을 평가하였을 때 20% 알코올 함량을 가지는 모형 술에 대해서 바닥층의 두께가 50 nm, 나노형상에서 골의 깊이가 20 nm, 나노형상의 배열주기가 300 nm일 때 SPR의 감도가 가장 좋아서 95%의 감도 향상을 얻을 수 있었다. SPR의 감도는 칩과 관련된 인자, 시료의 종류 및 상태에 따라 다르게 나타날 수 있으므로 측정 목적에 알맞은 칩의 설계와 선택이 요구된다.

A Novel Photonic Crystal Fiber Sensor with Three D-shaped Holes Based on Surface Plasmon Resonance

  • Bing, Pibin;Sui, Jialei;Huang, Shichao;Guo, Xinyue;Li, Zhongyang;Tan, Lian;Yao, Jianquan
    • Current Optics and Photonics
    • /
    • 제3권6호
    • /
    • pp.541-547
    • /
    • 2019
  • A novel photonic crystal fiber (PCF) sensor with three D-shaped holes based on surface plasmon resonance (SPR) is analyzed in this paper. Three D-shaped holes are filled with the analyte, and the gold film is deposited on the side of three planes. The design of D-shaped holes with outward expansion can effectively solve the uniformity problem of metallized nano-coating, it is beneficial to the filling of the analyte and is convenient for real-time measurement of the analyte. Compared with the hexagonal lattice structure, the triangular arrangement of the clad air holes can significantly reduce the transmission loss of light and improve the sensitivity of the sensor. The influences of the air hole diameter, the distance between D-shaped holes and core, and the counterclockwise rotation angle of D-shaped holes on sensing performance are studied. The simulation results show that the wavelength sensitivity of the designed sensor can be as high as 10100 nm/RIU and the resolution can reach 9.9 × 10-6 RIU.