• Title/Summary/Keyword: surface grafting

Search Result 192, Processing Time 0.023 seconds

Fuctionalization of SBA-16 Mesoporous Materials with Cobalt(III) Cage Amine Complex

  • Han, Sang-Cheol;Sujandi, Sujandi;Park, Sang-Eon
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.9
    • /
    • pp.1381-1384
    • /
    • 2005
  • Surface modification of tridimensional cubic mesoporous silica, SBA-16, was investigated with pendant arm functionalized cobalt diaminosarcophagine (diAMsar) cage complex which covalently grafted onto the silica surface through the silication with sylanol group. The spectroscopic results showed that the mesoporous structure was preserved under the $[Co(diAMsar)]^{3+}$ grafting reaction condition. Successful grafting prevented the cobalt diAMsar cage from leaching out from the SBA-16 support.

Preparation of Acrylic Acid-grafted Kenaf Fibers Using E-beam Irradiation and Evaluation of Permeability of Kenaf Fiber-cement Composites (전자선을 이용한 아크릴산 그라프트 케냐프 섬유의 제조 및 이를 이용한 케냐프 섬유보강 시멘트의 투수특성 평가)

  • Kim, Du Yeong;Jeun, Joon Pyo;Kim, Hyun Bin;Oh, Seung Hwan;Kang, Phil Hyun
    • Journal of Radiation Industry
    • /
    • v.8 no.1
    • /
    • pp.53-57
    • /
    • 2014
  • The kenaf is quickly developing as a renewable resource. Kenaf can be grown under a wide range of weather conditions. Modification of kenaf fiber by graft polymerization provides a significant route to alter the chemical properties, including surface hydrophilicity or hydrophobicity. In this study, kenaf fiber surfaces were grafted with acrylic acid as a hydrophilic group using electron beam irradiation. The grafting rate increased with an increase in grafting time. The FT-IR results confirmed that acrylic acid was successfully grafted onto the kenaf fibers. The wettability of the kenaf fiber was increased, accompanied by acylic acid grafting on the fiber surface. According to the permeability test result, it was found that acrylic acid grafted kenaf fiber reinforced cement composite was more reduced than non-grafted kenaf fiber reinforced cement composite.

Plasma-induced Graft Copolymerization of Glycidyl Methacrylate on the Surface of Polyethylene (폴리에틸렌 표면에 글리시딜메타크릴레이트의 플라즈마 유도 그래프트 공중합)

  • Kim, Ji-Eun;Liu, Xuyan;Choi, Ho-Suk;Kim, Jae-Ha;Park, Han-Oh
    • Polymer(Korea)
    • /
    • v.36 no.2
    • /
    • pp.137-144
    • /
    • 2012
  • The surface of polyethylene (PE) was modified through Ar atmospheric pressure plasma treatment and subsequent grafting of glycidyl methacrylate (GMA). Optimum plasma treatment conditions were determined through analyzing the surface free energies calculated from the contact angles between PE samples and three probe liquids, which were RF-power of 200 W, plasma treatment time of 600 sec, Ar flow rate of 5 LPM, and sample-holder moving speed of 20 mm/sec. To introduce the maximum amount of GMA on PE surface treated under the conditions, graft copolymerization conditions such as GMA concentration, temperature, and time were carefully controlled. Grafting degree (GD) was obtained through weight difference analysis of PE film before and after graft copolymerization. A maximum GD was achieved at the GMA concentration of 20 vol%, the temperature of $80^{\circ}C$, and the treatment time of 4 hr.

Modified membrane with antibacterial properties

  • Aryanti, P.T.P.;Sianipar, M.;Zunita, M.;Wenten, I.G.
    • Membrane and Water Treatment
    • /
    • v.8 no.5
    • /
    • pp.463-481
    • /
    • 2017
  • Bacteria have been considered as a major foulant that initiates the formation of biofilm on the polymeric membrane surface. Some polymeric membranes are naturally antibacterial and have low fouling properties, however, numerous efforts have been devoted to improve their antibacterial performance. These modifications are mostly carried out through blending the membrane with an antibacterial agent or introducing the antibacterial agent on the membrane surface by chemical grafting. Currently, a significant number of researches have reported nanocomposite membrane as a new approach to fabricate an excellent antibacterial membrane. The antibacterial nanoparticles are dispersed homogenously in membrane structure by blending method or coating onto the membrane surface. Aim of the modifications is to prevent the initial attachment of bacteria to membrane surface and kill bacteria when attached on the membrane surface. In this paper, several studies on antibacterial modified membranes, particularly for water treatment, will be reviewed comprehensively. Special attention will be given on polymeric membrane modifications by introducing antibacterial agents through different methods, such as blending, grafting, and coating.

Surface Metallization of Polyethylene Films Modified by Radiation Grafting of N-vinyl Pyrollidone (감마선 자극에 의한 금속이온 이식 도전성 폴리머)

  • A. Aal;V. V. Khutoryanskiy;Z. S. Nurkeeva;G. A. Mun;Soh, Dea-Wha
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.403-406
    • /
    • 2003
  • Poyethylene(PE) films could be modified by radiation grafting of N-vinyl pyrollidone(NVP) using radiation. FTIR spectra was used to confirm the modification of PE films. The modified films were activated by one-step or two-step methods for electroless Cu plating. Morphology of metallized films has been investigated. Electroless Cu plating onto the modified films depends mainly on the grafting degree and activation type. The electrical conductivity and adhesion of the metallized films has been investigated and tested in regard of grafting degree of samples.

  • PDF

GINGIVAL COVERAGE WITH CONNECTIVE TISSUE GRAFT TECHNIQUES ON DENUDED ROOT SURFACES (결합조직 이식술을 이용한 노출치근면의 치은피개)

  • Kim, Young-Jun;Jin, Yoo-Nam;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.1
    • /
    • pp.121-132
    • /
    • 1995
  • Patients, who have gingival recession and complain of root sensitivity, or esthetic concerns, are candidates for root coverage. When free gingival grafting is used for complete root corverage, the results may not be entirely predictible unless the recession is shallow and narrow because a free gingival graft depends on collateral circulation from the lateral and apical parts of the recipient bed to survive over the avascular root. Various pedicle graft techniques can produce more esthetic results, but these procedures are only indicated when adequate donor tissues are available adjacent to the defect. This case report presents three cases for root coverage using the various connective tissue graft techniques. In the first case(Class III & IV), subepithelial connective tissue grafting was done and resulted in gingival coverage on the two-thirds of exposed root surface and blended with the adjacent tissue in color and texture. In the second case(Class I), connective tissue and partial thickness double pedicle graft resulted in complete coverage of denuded root surface. In the third case(Class I), recession was treated by supraperiosteal envelope technique. The root surface was covered completely and esthetically. Finally, the esthetics in both colors and tissue contours were acceptable to patients in all cases by the connective tissue grafting. However, in the case of the reduced interdental bone, the denuded root surfaces were hardly covered completely.

  • PDF

Surface Characteristics and Fibroblast Adhesion Behavior of RGD-Immobilized Biodegradable PLLA Films

  • Jung Hyun Jung;Ahn Kwang-Duk;Han Dong Keun;Ahn Dong-June
    • Macromolecular Research
    • /
    • v.13 no.5
    • /
    • pp.446-452
    • /
    • 2005
  • The interactions between the surface of scaffolds and specific cells play an important role in tissue engineering applications. Some cell adhesive ligand peptides including Arg-Gly-Asp (RGD) have been grafted into polymeric scaffolds to improve specific cell attachment. In order to make cell adhesive scaffolds for tissue regeneration, biodegradable nonporous poly(L-lactic acid) (PLLA) films were prepared by using a solvent casting technique with chloroform. The hydrophobic PLLA films were surface-modified by Argon plasma treatment and in situ direct acrylic acid (AA) grafting to get hydrophilic PLLA-g-PAA. The obtained carboxylic groups of PLLA-g-PAA were coupled with the amine groups of Gly-Arg-Asp-Gly (GRDG, control) and GRGD as a ligand peptide to get PLLA-g-GRDG and PLLA-g-GRGD, respectively. The surface properties of the modified PLLA films were examined by various surface analyses. The surface structures of the PLLA films were confirmed by ATR-FTIR and ESCA, whereas the immobilized amounts of the ligand peptides were 138-145 pmol/$cm^2$. The PLLA surfaces were more hydrophilic after AA and/or RGD grafting but their surface morphologies showed still relatively smoothness. Fibroblast adhesion to the PLLA surfaces was improved in the order of PLLA control

Studies on the Grafting of the Magnolia grandiflora L. (III) (태산목(泰山木)의 접목(接木)에 관(關)한 연구(硏究)(제(第)III보(報)))

  • Lee, Jyung Seuk
    • Journal of Korean Society of Forest Science
    • /
    • v.26 no.1
    • /
    • pp.49-55
    • /
    • 1975
  • This study was carried out to find out the proper method of grafting of Magnolia grandiflora L. Magnolia kobus DC. was used as stocks and the modified veneer grafting method in which a flap was attached to the cut surface of scion was adopted. And also the environment of the grafting beds was controlled for giving optimum humidity (90-100%) and temperature ($20-25^{\circ}C$). The results are summarized as follows: 1. Two year-old seedlings of M. kobus were best as stocks for grafting of M. gantiflora. 2. The modified veneer grafting which brought the successful result of 43 to 89.5 percent found to be very efficient method. 3. The environmental control made of vinyl tunnel and screen (lath) was very effective to attain to the excellent result of 89 percent. 4. For scions, one to two year-old branches with well developed winter buds collected just before the time of grafting gave the best results. 5. The optimum season for grafting in Kwangju districts was 15 to 20, April.

  • PDF

Synthesis and Characterization of Polypropylene-grafted Graphene Oxide via "Grafting-to" Method (폴리프로필렌으로 그래프트된 그래핀 옥사이드 제조 및 특성 분석)

  • Lee, Jong-Hee;Oh, Chang-Ho;Lim, Jung-Hyurk;Kim, Kyung-Min
    • Polymer(Korea)
    • /
    • v.39 no.1
    • /
    • pp.180-184
    • /
    • 2015
  • PP-grafted GO was prepared by the reaction of graphene oxide (GO) containing 2-bromoisobuyryl groups and polypropylene (PP) having hydroxyl groups (PP-OH) via a "grafting-to" method. GO-Br was synthesized by the reaction of GO and 2-bromoisobutyryl bromide under a basic condition. PP-MAH was reacted with ethanolamine to produce PP-OH. The melting temperature of PP-grafted GO was shifted to the higher temperature than that of PP-OH. Also, the thermal stability of PP-grafted GO was increased as compared to PP-OH and GO. These results demonstrated that the grafted coating polymer PP was effective for enhancing the thermal stability of GO. The higher surface roughness of PP-grafted GO was resulted from the chemical attachment of PP on the surface of GO. The characterization of PP-grafted GO was conducted from Fourier transform infrared spectroscopy (FTIR), Raman spectroscopy, differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and scanning electron microscope (SEM).

A systematic review of the scalp donor site for split-thickness skin grafting

  • Oh, Suk Joon
    • Archives of Plastic Surgery
    • /
    • v.47 no.6
    • /
    • pp.528-534
    • /
    • 2020
  • Split-thickness skin grafting (STSG) is the gold standard for coverage of acute burns and reconstructive wounds. However, the choice of the donor site for STSG varies among surgeons, and the scalp represents a relatively under-utilized donor site. Understanding the validity of potential risks will assist in optimizing wound management. A comprehensive literature search was conducted of the PubMed database to identify studies evaluating scalp skin grafting in human subjects published between January 1, 1964 and December 31, 2019. Data were collected on early and late complications at the scalp donor site. In total, 27 articles comparing scalp donor site complications were included. The selected studies included analyses of acute burn patients only (21 of 27 articles), mean total body surface area (20 of 27), age distribution (22 of 27), sex (12 of 27), ethnicity (5 of 27), tumescent technique (21 of 27), depth setting of the dermatome (24 of 27), number of harvests (20 of 27), mean days of epithelization (18 of 27), and early and late complications (27 of 27). The total rate of early complications was 3.82% (117 of 3,062 patients). The total rate of late complications was 5.19% (159 of 3,062 patients). The literature on scalp skin grafting has not yet identified an ideal surgical technique for preventing donor site complications. Although scalp skin grafting provided superior outcomes with fewer donor site complications, there continues to be a lack of standardization. The use of scalp donor sites for STSG can prevent early and late complications if proper surgical planning, procedures, and postoperative care are performed.