• 제목/요약/키워드: stray field

검색결과 86건 처리시간 0.052초

국가기간시설물의 전식대책(안) 및 그 적용 사례(1) (A Case Study(1) of Mitigation Methode of DC Stray Current for Underground Metallic Structures in KOREA)

  • 배정효;하윤철;하태현;이현구;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1612-1614
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) design of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system. We installed the mitigation system at the real field and test of its efficiency in Busan and Seoul, Korea. In this paper, the results of field test, especially, distributed ICCP system is described.

  • PDF

$^{60}Co\;\gamma$선과 10MV X선의 조사면 밖의 선량분포에 관한 연구 (A Study on Dobe Distribution outside Co-60 $\gamma$ Ray ana 10MV X Ray Fields)

  • 강위생;허승재;하성환
    • Radiation Oncology Journal
    • /
    • 제2권2호
    • /
    • pp.271-280
    • /
    • 1984
  • The peripheral dose, defined as the dose outside therapeutic photon fields, which is responsible for the functional damage of the critical organs, fetus, and radiation. induced carcinogenesis, has been investigated for $^{60}Co\;\gamma$ ray and 10 MV Xray. It was measured by silicon diode controlled by semiautomated water phantom without any shielding or with lead plate of HVL thickness put horizontally or vertically to shield stray radiations. Authors could obtain following results. 1. The peripheral dose was larger than $0.7\%$ of central axis maximum dose even at 20cm distance from field margin. That is clinically significant, so it should be reduced. 2. Even for square fields of 10 MV Xray, radial peripheral dose distribution did not coincide with transverse distribution, because of the position of collimator jaws. 3. Between surface and $d_m$, the peripheral dose distributions show a pattern of the dose distribution of electron beams and the maximum doss was approximately proportional to the length of a side of square field. 4. The peripheral doses depended on radiation quality, field size, distance from field margin and depth in water. Distance from field margin was the most important factor. 5. Except for near surface, the peripheral dose from phantom was approximately equal to that from therapy unit. 6. To reduce the surface dose outside fields, therapist should shield stray radiations from therapy unit by lead plate of at least one HVL for 10 MV X-ray and by bolus equivalent to tissue of 0.5cm thickness for $^{60}Co$. 7. To reduce the dose at depth deeper than $d_m$, it is desirable to shield stray radiations from therapy unit by lead.

  • PDF

도시철도 전식방지 기술기준에 따른 시험방법 비교분석 (Comparison Analysis of Field Test Methods Based on Technical Criteria of Electrolytic Corrosion Protection in Urban Railway)

  • 김재문;정호성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1885-1891
    • /
    • 2010
  • Recently metropolitan local governments is actively introducing urban railway's expand and light rail transit as a means of new transport system. DC electricity feeder system operating in the domestic urban railway is typically a feedback circuit consisted of the contact wire and electric railway vehicle via rail. But stray current is to be defined as a current flowing on a structure that is not part of the intended electrical circuit with respect to a given structure. Stray current is generally results from the leakage of return currents from large DC traction systems that are grounded or have a bad earth-insulated return path. At the place where the current leaves the rail and metallic structures, electrolytic corrosion may take place. This paper presents comparison analysis of field test methods based on criteria of electrolytic corrosion protection of buried metallic structures adjacent to DC traction systems.

  • PDF

국내 도시철도 전식방지 기술기준에 따른 시험사례 비교분석 (The Comparison Analysis of Field Test Cases on Technical Specifications of Electrolytic Corrosion in Urban Railway)

  • 김재문;정호성;김양수
    • 전기학회논문지P
    • /
    • 제59권3호
    • /
    • pp.305-310
    • /
    • 2010
  • DC electricity feeder system operating in the urban railway is typically a feedback circuit consisted of the contact wire and electric railway vehicle via rail. But stray current is flowed on a structure that is not part of the intended electrical circuit with respect to a given structure. This paper presents comparison analysis of field test cases based on criteria of electrolytic corrosion protection of buried metallic structures adjacent to DC traction systems. As a result of it, we confirmed that measurement methods are different from each other about the same tests. Therefore measurement methods to prevent electrolytic corrosion need to establish electrical facilities standards to be applied domestic.

Electric Field Energy Harvesting Powered Wireless Sensors for Smart Grid

  • Chang, Keun-Su;Kang, Sung-Muk;Park, Kyung-Jin;Shin, Seung-Hwan;Kim, Hyeong-Seok;Kim, Ho-Seong
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권1호
    • /
    • pp.75-80
    • /
    • 2012
  • In this paper, a new energy harvesting technology using stray electric field of an electric power line is presented. It is found that energy can be harvested and stored in the storage capacitor that is connected to a cylindrical aluminum foil wrapped around a commercial insulated 220 V power line. The average current flowing into 47 ${\mu}F$ storage capacitor is about 4.53 ${\mu}A$ with 60 cm long cylindrical aluminum foil, and it is possible to operate wireless sensor node to transmit RF data every 42 seconds. The harvested average power is about 47 ${\mu}W$ in this case. Since the energy can be harvested without removing insulating sheath, it is believed that the proposed harvesting technology can be applied to power the sensor nodes in wireless ubiquitous sensor network and smart grid system.

A Miniaturized Catadioptric Laser-Irradiation-Precision Test System

  • Liu, Huan;Sun, Hao;Wang, Chunyan
    • Current Optics and Photonics
    • /
    • 제5권2호
    • /
    • pp.164-172
    • /
    • 2021
  • In this paper a catadioptric laser-irradiation-precision test system is designed, to achieve a high-precision laser-irradiation-accuracy test. In this system, we adopt the method of imaging the entire target surface at a certain distance to realize the measurement of laser-irradiation precision. The method possesses the advantages of convenient operation, high sensitivity, and good stability. To meet the test accuracy requirement of 100 mm/km (0.01%), the coma, field curvature, and distortion over the entire field of view should be eliminated from the optical system's design. Taking into account the whole length of the tube and the influence of stray light on the structure type, a catadioptric system with a hood added near the primary imaging surface is designed. After optimization using the ZEMAX software, the modulation transfer function (MTF) of the designed optical system is 0.6 at 30 lp/mm, the full-field-of-view distortion is better than 0.18%, and the energy concentration in the 10-㎛-radius surrounding circle reaches about 90%. The illumination-accuracy test results show that the measurement accuracy of the radiation hit rate is better than 50 mm when the test distance is 1 km, which is better than the requirement of 100 mm/km for the laser-irradiation-accuracy test.

MRI용 초전도 마그네트의 능동차폐 효과 (Shield Effects of the Actively Shielded Superconduction Magent for MRI)

  • 배준환;진홍범;고락길;권영길;이언용;손명환;백승규;김해종;류강식
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.113-116
    • /
    • 1999
  • The shield effects of the actively shielded superconducting magnet systems for MRI were investigated. The magnetic field was calculated by FEM considering the winding error and the homogeneity of the magnetic field at the 30cm DSV was presented. The 5 gauss stray field line was restricted within 5m form the magnet center.

  • PDF

매설배관과 직류전기철도의 표유전류 간섭분석 (Analysis of Stray Current Interference between Underground Pipelines and DC Electric Railways)

  • 하윤철;배정효;하태현;이현구;김대경
    • 한국가스학회지
    • /
    • 제10권3호
    • /
    • pp.41-47
    • /
    • 2006
  • 가스배관, 상수관, 송유관 등의 지중 매설배관이 직류 전기철도와 인접해 있는 경우, 전기철도 시스템의 귀선 회로로 사용되는 레일에서 누설되는 표유전류에 의해 이들 금속배관에는 전기적 부식, 즉 전식이 발생할 수 있다. 전식에 의한 집중 부식은 전기방식으로 보호되는 배관에 있어서도 지속적인 재료의 열화와 이에 따른 파손을 일으킬 수 있어 대형사고로 발전할 소지를 가지고 있다. 국내에서는 이러한 표유전류에 대한 대책으로 배관과 레일을 전기적으로 접속하는 배류법이 적용되고 있는데 특히 가스배관을 중심으로 한 강제배류법의 급속한 증가에 의해 간섭문제가 매우 복잡해지고 있다. 본 논문에서는 직류전기철도시스템과 매설배관 사이의 전기적 간섭 문제를 서울과 부산 지역에서 수행한 현장 실태조사의 결과를 통해 살펴본다.

  • PDF

과학기술위성3호 부탑재체 소형영상분광기 미광 해석 (Stray Light Analysis of a Compact Imaging Spectrometer for a Microsatellite STSAT-3)

  • 이진아;이준호
    • 한국광학회지
    • /
    • 제23권4호
    • /
    • pp.167-171
    • /
    • 2012
  • 과학기술위성3호 부탑재체인 COMIS(Compact Imaging Spectrometer)는 무게 4.25 kg의 소형영상분광기로써 지표면 및 대기과학을 연구할 목적으로 개발되었다. COMIS는 지표면, 대기, 수면으로부터 반사되는 태양 에너지를 고도 700 km에서 가시광 및 근적외선 영역(0.4 ~1.05 ${\mu}m$)에서 해상도 27 m, 관측폭 28 km, 파장 분해능 2 ~ 15 nm를 갖도록 결상 광학계와 분광 광학계로 구성된다. 먼저 지상 $27m{\times}28km$의 해당되는 지표면에서 반사된 빛은 COMIS의 결상 광학계에 의하여 상면에 위치한 $11.8{\mu}m{\times}12.1mm$의 선형 슬릿으로 맺히고, 이후 약 1.1배의 배율을 갖는 분광 광학계의 상면에 $1.4mm{\times}13.3mm$의 크기를 갖는 분광 스펙트럼 영상으로 나타난다. 이 때 부분 반사 및 산란 등에 의한 신호대잡음비(SNR, signal to noise ratio) 저하를 방지하기 위하여 렌즈 및 거울 면에 무반사 및 고반사 코팅이 적용되었고, 내부에는 미광 차단 구조물 등이 설치되었다. 미광 차단 설계의 적정성을 확인하기 위하여 미광 모델 수립과 상용 프로그램을 이용한 미광 해석을 수행하였다. 해석 결과 미광의 세기는 정상 결상 대비 무시할 정도의 값($10^{-5}$)으로 영상에는 실질적인 영향이 없음을 확인하였다.

Stray Field Effect of Py Electrodes in Spin FET

  • Shim, Seong-Hoon;Chang, Joon-Yeon;Han, Suk-Hee;Lee, Yun-Hi
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2007년도 동계학술연구발표회 및 스핀트로닉스와 나노물리에관한 국제심포지움
    • /
    • pp.112-113
    • /
    • 2007
  • PDF