• Title/Summary/Keyword: stiffness deterioration

Search Result 140, Processing Time 0.024 seconds

Sound Insulation Design of the Corrugated Steel Panel Considering Local Resonance (국부 공진을 고려한 주름강판의 차음 설계)

  • Kim, Seock-Hyun;Lee, Hyun-Woo;Kim, Jung-Tae;Kim, Jae-Cheol
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.7
    • /
    • pp.672-676
    • /
    • 2010
  • In a railway vehicle, corrugated steel panel is widely used for the floor structure because of its high bending stiffness and light weight. However, this panel shows lower sound insulation performance than that of the flat plate with the same weight. Especially, in a particular frequency region, transmission loss(TL) rapidly decreases and it results in the deterioration of sound insulation performance of the overall floor structure. This study identifies that the severe decrease in TL is caused from the local resonance of the periodic corrugated structure. TL decrease by local resonance is investigated by experiment and finite element analysis. Finally, design modification of the corrugation is proposed to improve TL and the effect is verified by experiment.

Hysteresis modeling for cyclic behavior of concrete-steel composite joints using modified CSO

  • Yu, Yang;Samali, Bijan;Zhang, Chunwei;Askari, Mohsen
    • Steel and Composite Structures
    • /
    • v.33 no.2
    • /
    • pp.277-298
    • /
    • 2019
  • Concrete filled steel tubular (CFST) column joints with composite beams have been widely used as lateral loading resisting elements in civil infrastructure. To better utilize these innovative joints for the application of structural seismic design and analysis, it is of great importance to investigate the dynamic behavior of the joint under cyclic loading. With this aim in mind, a novel phenomenal model has been put forward in this paper, in which a Bouc-Wen hysteresis component is employed to portray the strength and stiffness deterioration phenomenon caused by increment of loading cycle. Then, a modified chicken swarm optimization algorithm was used to estimate the optimal model parameters via solving a global minimum optimization problem. Finally, the experimental data tested from five specimens subjected to cyclic loadings were used to validate the performance of the proposed model. The results effectively demonstrate that the proposed model is an easy and more realistic tool that can be used for the pre-design of CFST column joints with reduced beam section (RBS) composite beams.

Hysteretic Behavior of RHS Columns Under Random Cyclic Loading Considering Local Buckling

  • Yamada, Satoshi;Ishida, Takanori;Jiao, Yu
    • International journal of steel structures
    • /
    • v.18 no.5
    • /
    • pp.1761-1771
    • /
    • 2018
  • In this paper, a hysteretic model of rectangular hollow section (RHS) columns that includes the deteriorating range caused by local buckling is proposed. The proposed model consists of the skeleton curve, the Bauschinger part that appears before reaching the maximum strength, the strength increasing part of the deteriorating range, and the unloading part. Of these, the skeleton curve, including the deterioration range caused by local buckling, which is considered to be equivalent to the load-deformation relationship under monotonic loading, is obtained through an analytical method. Bi-linear hysteretic models based on experimental results are applied to the Bauschinger part and the strength increasing part. The elastic stiffness is applied to the unloading part. The proposed model is verified by comparing with experimental results of RHS columns under monotonic and cyclic loading.

A coupled vibration model of double-rod in cross flow for grid-to-rod fretting wear analysis

  • H. Huang;T. Liu;P. Li;Y.R. Yang
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1407-1424
    • /
    • 2024
  • In Pressurized Water Reactors, most of the failed fuel rods are often observed at the periphery of the fuel assembly, especially near the core baffle. The rod vibration-induced fretting wear is a significant failure mechanism strongly correlated with the coolant and support conditions. This paper presents a coupled vibration model of double-rod to predict the grid-to-rod fretting (GTRF) wear. A motion-dependent fluid force model is used to simulate the coolant cross flow, the gap constraints with asymmetric stiffness between spring and dimple on the vibration form, and the fretting wear are discussed. The results show the effect of the coupled vibration on the deterioration of wear, providing a sound theoretical explanation of some failure phenomena observed in the previous experiment. Exploratively, we analyze the impact of the baffle jet on the GTRF wear, which indicates that the high-velocity cross-flow will significantly affect the vibration forms while sharply changing the wear behavior.

Experimental Study on the Strengthening Effect of External Prestressing Method Considering Deterioration (구조물 노후도를 반영한 외부긴장 보강 효과에 관한 실험적 연구)

  • Kim, Sang-Hyun;Jung, Woo-Tai;Kang, Jae-Yoon;Park, Hee-Beom;Park, Jong-Sup
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.1
    • /
    • pp.1-6
    • /
    • 2021
  • Concrete structures gradually age due to deterioration of materials or excess loads and environmental factors, and their performance decreases, affecting the usability and safety of structures. Although external tension construction methods are widely used among the reinforcement methods of old bridges, it is insufficient to identify the effects and effects of reinforcement depending on the level of aging. Therefore, in this study, a four-point loading experiment was conducted on the subject with the non-reinforced and external tensioning method to confirm the reinforcement effect of the external tensioning method, assuming the aging of the structure as a reduction in the compressive strength and tensile reinforcement of concrete, to analyze the behavior of the reinforcement and confirm the reinforcement effect. As a result of the experiment, it was difficult to identify the amount of reinforcement in the extreme condition due to early elimination of the anchorage. Therefore, compliance with the regulations on anchor bolts is required when applying the external tension reinforcement method. Crack load and yield load increased depending on whether external tension was reinforced, but before the crack, the stiffness before and after reinforcement was similar, making it difficult to confirm the reinforcement effect.

Analytical Model of Beam-Column Joint for Inelastic Behavior Under Various Loading History (철근콘크리트 보-기둥 접합부 해석모델)

  • 유영찬;서수연;이원호;이리형
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.1
    • /
    • pp.120-130
    • /
    • 1994
  • The purpose of this study is to propose the analytical model for the hysteretic behavior of Reinforced Concrete bearn-column joints under various loading history. Discrete line elernents , YVith inelastic rotational spring was adopted to consider the movement of plastic hinging zone influenced by the details of longitudinal reinforcements. Also hysteretic model was constructed by excluding such variables which can not be utilized in dynamic analysis of Reinforced Concrete. structure that it will be adoptable in two-dimensional inelastic frame ardysis with 6-DOF. From the analysis of previous test results, it was found that stiffness deterioration caused by inelastic hysteretic loadings can be predicted by the functron of basic pinching coefficients, ductility ratio.and yield strength ratio of members. Strength degradation coefficients were newly proposed to explain the difference of inelastic behavior of members caused by spacing ratio of transverse steel and sectlon aspect ratio. The energy dissipation capacities calculated using the analytical model proposed in thls paper show a good agreements w~lh test results by an error of 10~20%.

Inelastic Cyclic Behavior of Locally Buckled Steel Members (국부좌굴된 강구조부재의 비탄성 반복 거동)

  • Lee, Eun Taik;Song, Keum Jung
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.2 s.75
    • /
    • pp.139-149
    • /
    • 2005
  • Post-local buckling behavior is a very important consideration in plastic and seismic design of steel structures. It describes the structural behavior up to the final collapse state. In order to assess the actual reliability of structures under severe repeated loading, such as strong earthquakes, it is necessary to evaluate the progressive cyclic deterioration of stiffness as well as the strength and energy dissipation capacity of the structures after local buckling happens. In this study, a simple analytical model developed for predicting post-local buckling behavior for cyclic and non-proportional loading histories, has been proposed. This analytical model uses the stress resultant model based on the two surface model. Analytical moment-curvature relationship using this model compare well with the experimental results in constant amplitude cycling, and linearized energy deterioration which is very important in seismic design can be predicted from the proposed model.

Analytical Modeling for Reinforced Concrete Columns with Relaxed Section Details

  • Kim, Taewan;Chu, Yurim;Park, Hong-Gun
    • Architectural research
    • /
    • v.19 no.3
    • /
    • pp.79-87
    • /
    • 2017
  • In earthquake engineering, dynamic analyses are usually conducted by using a nonlinear analytical model of the entire building in order to identify the performance against earthquakes. At the same time, a large number of dynamic analyses are required to consider uncertainties on analytical models and ground motions. Therefore, it is necessary for the analytical model to be adequate, that is to say, the runtime should not be too long as the entire building is modeled to be in much detail, or the nonlinear model should not yield outputs very far from the actual ones by excluding important behaviors too much. The analytical model is usually developed based on experimental results, which have been already conducted for reinforced concrete columns with relaxed details. Therefore, this study aimed at making analytical models to be able to simulate the hysteretic behavior of the columns simply and easily. The analytical model utilizes a lumped hinge model to represent nonlinear moment-rotation hysteretic behavior of RC columns, which is feasible for nonlinear dynamic analyses usually conducted in earthquake engineering and for matching the analytical model to test results. For the analytical model, elements and material models provided by OpenSees are utilized. The analytical model can define the envelope curve, pinching, and unloading stiffness deterioration, but shortcoming of this model is not to be able to consider axial force-moment interaction directly and to simulate strength deterioration after post-capping completely. However, the analytical model can still represent test results well by considering that the goal of this study is to propose a general way to represent the hysteretic behavior of RC columns with relaxed details, not to provide parameters for a refined hysteretic model that can be just applied case by case.

Inelastic and Local Buckling Behavior of H-Beams with Web Opening under Cyclic Loadings (반복하중을 받는 H형강 유공보의 소성 및 국부좌굴 거동)

  • Lee, Eun Taek;Kim, Cheol Hwan;Oh, Woo Hun
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.3
    • /
    • pp.271-279
    • /
    • 2003
  • Many researches have been conducted to describe the elastic and inelastic behavior of H-shaped beams with web openings, and were generally concentrated on the uniaxial loading conditions. With previous research results, the formulae for the design of beams with web openings, considering local buckling, have been proposed by Darwin. Although the formulae are so simple and useful to apply to real situations, it needs more research on cyclic loading conditions. In this experimental study, a total of seven H-shaped beams with circular web openings under cyclic loading conditions were investigated. The dimension criteria were based on the formulae proposed by Darwin. The suitability of the existing design formulae, the effects of plastic hinges on beams with web openings, and the local bucking around the web openings to the beam strength under cyclic loading were also investigated through by the observations of the behavior of these beams with various dimensional openings.

Seismic torsional vibration in elevated tanks

  • Dutta, Sekhar Chandra;Murty, C.V.R.;Jain, Sudhir K.
    • Structural Engineering and Mechanics
    • /
    • v.9 no.6
    • /
    • pp.615-636
    • /
    • 2000
  • Some elevated water tanks have failed due to torsional vibrations in past earthquakes. The overall axisymmetric structural geometry and mass distribution of such structures may leave only a small accidental eccentricity between centre of stiffness and centre of mass. Such a small accidental eccentricity is not expected to cause a torsional failure. This paper studies the possibility of amplified torsional behaviour of elevated water tanks due to such small accidental eccentricity in the elastic as well as inelastic range; using two simple idealized systems with two coupled lateral-torsional degrees of freedom. The systems are capable of retaining the characteristics of two extreme categories of water tanks namely, a) tanks on staging with less number of columns and panels and b) tanks on staging with large number of columns and panels. The study shows that the presence of a small eccentricity may lead to large displacement of the staging edge in the elastic range, if the torsional-to-lateral time period ratio $({\tau})$ of the elevated tanks lies within a critical range of 0.7< ${\tau}$ <1.25. Inelastic behaviour study reveals that such excessive displacement in some of the reinforced concrete staging elements may cause unsymmetric yielding. This may lead to progressive strength deterioration through successive yielding in same elements under cyclic loading during earthquakes. Such localized strength drop progressively develop large strength eccentricity resulting in large localized inelastic displacement and ductility demand, leading to failure. So, elevated water tanks should have ${\tau}$ outside the said critical range to avoid amplified torsional response. The tanks supported on staging with less number of columns and panels are found to have greater torsional vulnerability. Tanks located near faults seem to have torsional vulnerability for large ${\tau}$.