Magazine of the Korea Concrete Institute (콘크리트학회지)
- Volume 6 Issue 1
- /
- Pages.120-130
- /
- 1994
- /
- 1018-1415(pISSN)
DOI QR Code
Analytical Model of Beam-Column Joint for Inelastic Behavior Under Various Loading History
철근콘크리트 보-기둥 접합부 해석모델
Abstract
The purpose of this study is to propose the analytical model for the hysteretic behavior of Reinforced Concrete bearn-column joints under various loading history. Discrete line elernents , YVith inelastic rotational spring was adopted to consider the movement of plastic hinging zone influenced by the details of longitudinal reinforcements. Also hysteretic model was constructed by excluding such variables which can not be utilized in dynamic analysis of Reinforced Concrete. structure that it will be adoptable in two-dimensional inelastic frame ardysis with 6-DOF. From the analysis of previous test results, it was found that stiffness deterioration caused by inelastic hysteretic loadings can be predicted by the functron of basic pinching coefficients, ductility ratio.and yield strength ratio of members. Strength degradation coefficients were newly proposed to explain the difference of inelastic behavior of members caused by spacing ratio of transverse steel and sectlon aspect ratio. The energy dissipation capacities calculated using the analytical model proposed in thls paper show a good agreements w~lh test results by an error of 10~20%.
본 연구의 목적은 반목하중을 받는 철근콘크리트 부재의 이력거동을 적절히 예측할 수 있는 해석모델을 구축하고 기존 연구자들의 실험결과를 분석하여 부재의 다양한 이력거동을 예측할 수 있는 이력모델을 제안하는데 있다. 이력모델의 구축에는 골조의 동적해석에 정량적으로 사용할 수 없는 변수들을 배제함으로써 6개 자유도를 갖는 평면 프레임의 비선형 동적해석에 적용가능한 해석요소를 개발하였다. 해석모델은 소성힌지부를 단일 스프링으로 치환한 분리선형요소 모델을 사용하였으며 부재의 길이방향 철근 배근상태에 따라 소성힌지부의 이동을 고려할 수 있도록 하였다. 기존 연구자들의 실험결과를 비교
Keywords
- reinforced concrete;
- discrete line element;
- hysteretic model;
- beam-column joint;
- inelastic rotational spring;
- plastic hinging zone;
- strength degradation;
- stiffness deterioration;
- energy dissipation capacity