• Title/Summary/Keyword: stiff system

Search Result 158, Processing Time 0.025 seconds

A Study on Numerical Solution Methods in Stiff Constrained Mechanical Systems (강성 구속기계계의 해법에 관한 연구)

  • 한형석;박태원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.2
    • /
    • pp.374-381
    • /
    • 1995
  • In this paper, integration methods for stiff constrained mechanical systems are studied to analyze dynamic response of the stiff mechanical system efficiently. The stiff, non-stiff systems are identified by using eigenvalues of the Jacobian of the systems. To integrate both stiff system and non-stiff system efficiently a new switching method between the non-stiff differential equation solver and the stiff differential equation solver is presented.

An Experimental Study of Flexible-Stiff Mixed System of High Yield Ratio-High Strength Steel for the Practical Use (고항복비-고강도강의 유강혼합구조 시스템 적용에 관한 실험적 연구)

  • Oh, Sang Hoon;Kim, Jin Won;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.4 s.77
    • /
    • pp.395-405
    • /
    • 2005
  • This paper summarizes the test results of the flexible-stiff mixed system for the effective use of high-strength steel. Steel with a high degree of strength and performance is being increasingly required as buildings get larger and taller. High-strength steels cannot be used for many applications, though, because they have a number of defects. For instance, they have a high yield ratio, a small strain in maximum stress, and equal Young's modulus compared to mild steels. A new structural system is needed to effectively use high-strength steels with some defects. This paper proposes the flexible-stiff mixed system for the effective use of high-strength steels with high yield ratios. The possibility of using the system is discussed through the test of flexible-stiff mixed columns with high-strength steels. The main variable of the specimens is the yield displacement ratio, including both the force ratio and the stiffness ratio. The proper yield displacement ratio is proposed by adopting the flexible-stiff mixed system. The test results showed that the proposed flexible-stiff mixed system has a high capacity for energy absorption and the highest capacity for energy absorption when the yield displacement ratio of the flexible element to the stiff element ranges from 2.7 to 3.3.

Impact of soft and stiff soil interlayers on the pile group dynamic response under lateral harmonic load

  • Masoud Oulapour;Sam Esfandiari;Mohammad M. Olapour
    • Geomechanics and Engineering
    • /
    • v.33 no.6
    • /
    • pp.583-596
    • /
    • 2023
  • The interlayers, either softer or stiffer than the surrounding layers, are usually overlooked during field investigation due to the small thickness. They may be neglected through the analysis process for simplicity. However, they may significantly affect the dynamic behavior of the soil-foundation system. In this study, a series of 3D finite-element Direct-solution steady-state harmonic analyses were carried out using ABAQUS/CAE software to investigate the impacts of interlayers on the dynamic response of a cast in place pile group subjected to horizontal harmonic load. The experimental data of a 3×2 pile group testing was used to verify the numerical modeling. The effects of thickness, depth, and shear modulus of the interlayers on the dynamic response of the pile group are investigated. The simulations were conducted on both stiff and soft soils. It was found that the soft interlayers affect the frequency-amplitude curve of the system only in frequencies higher than 70% of the resonant frequency of the base soil. While, the effect of stiff interlayer in soft base soil started at frequency of 35% of the resonant frequency of the base soil. Also, it was observed that a shallow stiff interlayer increased the resonant amplitude by 11%, while a deep one only increased the resonant frequency by 7%. Moreover, a shallow soft interlayer increased the resonant frequency by 20% in soft base soils, whereas, it had an effect as low as 6% on resonant amplitude. Also, the results showed that deep soft interlayers increased the resonant amplitude by 17 to 20% in both soft and stiff base soils due to a reduction in lateral support of the piles. In the cases of deep thick, soft interlayers, the resonant frequency reduced significantly, i.e., 16 to 20%. It was found that the stiff interlayers were most effective on the amplitude and frequency of the pile group.

Seismic analysis of 3-D two adjacent buildings connected by viscous dampers with effect of underneath different soil kinds

  • Farghaly, Ahmed Abdelraheem
    • Smart Structures and Systems
    • /
    • v.15 no.5
    • /
    • pp.1293-1309
    • /
    • 2015
  • 3D two adjacent buildings with different heights founded in different kinds of soil connected with viscous dampers groups, with especial arrangement in plane, were investigated. Soil structure interaction for three different kinds of soil (stiff, medium and soft) were modeled as 3D Winkler model to give the realistic behavior of adjacent buildings connected with viscous dampers under various earthquake excitations taking in the account the effect of different kinds of soil beneath the buildings, using SAP2000n to model the whole system. A range of soil properties and soil damping characteristics are chosen which gives broad picture of connected structures system behavior resulted from the influence soil-structure interaction. Its conclusion that the response of connected structures system founded on soft soil are more critical than those founded on stiff soil. The behavior of connected structures is different from those with fixed base bigger by nearly 20%, and the efficiency of viscous dampers connecting the two adjacent buildings is reduced by nearly 25% less than those founded on stiff soil.

Lower extremity stiffness over different landing methods during hopping (호피 시 착지방법에 따른 하지 강성도)

  • Lee, J.J.;Son, J.S.;Kim, J.Y.;Kim, Y.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.105-108
    • /
    • 2011
  • The purpose of the present study was to analyze the lower stiffness over the difference between soft and stiff landings during hopping. Five male subjects performed hopping on two legs at 2.5 Hz. During the experiments, 3D motion capture system was used to obtain the kinematic data and two force plates were synchronized to calculate the kinetic data. We determined lower extremity stiffness of the knee and ankle from kinetic and kinematic data. Leg stiffness was approximately 1.2-times significantly higher in stiff landing than in soft landing_ There was no significant difference in knee joint stiffness between soft and stiff landings. Ankle joint stiffness was approximately 1.34-times significantly higher in stiff landing than in soft landing. These results suggest that humans adjust lower extremity stiffness over the comparison of two different landing methods we evaluated.

HIGH ORDER IMPLICIT METHOD FOR ODES STIFF SYSTEMS

  • Vasilyeva, Tatiana;Vasilev, Eugeny
    • Journal of applied mathematics & informatics
    • /
    • v.8 no.1
    • /
    • pp.165-180
    • /
    • 2001
  • This paper presents a new difference scheme for numerical solution of stiff system of ODE’s. The present study is mainly motivated to develop an absolutely stable numerical method with a high order of approximation. In this work a double implicit A-stable difference scheme with the sixth order of approximation is suggested. Another purpose of this study is to introduce automatic choice of the integration step size of the difference scheme which is derived from the proposed scheme and the one step scheme of the fourth order of approximation. The algorithm was tested by means of solving the Kreiss problem and a chemical kinetics problem. The behavior of the gas explosive mixture (H₂+ O₂) in a closed space with a mobile piston is considered in test problem 2. It is our conclusion that a hydrogen-operated engine will permit to decrease the emitted levels of hazardous atmospheric pollutants.

Evaluation of Strengthening Performance of Stiff Type Polyurea Retrofitted RC Slab Based on Attachment Procedure (경질형 폴리우레아의 개발 및 보강 순서에 따른 RC 슬래브의 성능 평가)

  • Kim, Jang-Ho Jay;Park, Jeong-Cheon;Lee, Sang-Won;Kim, Sung-Bae
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.4
    • /
    • pp.511-520
    • /
    • 2011
  • Recent studies to improve reinforcement of structures have developed stiff type Polyurea by using highly polymized compound Polyurea, but the reinforcing effect of it appears to be merely good. To find the proper usage of Polyurea as structural reinforcement, stiff type Polyurea has developed by manipulating the ratio of the components that consist flexural type Polyurea and the developed stiff type Polyurea shows higher hardness and tensile capacity. The reinforcement effect evaluation of has been performed by the polyurea applied RC slab specimens, and the reinforcement effect of the combination of fiber sheet and polyurea has been tested. The results shows that the Polyurea applied specimens have significant improvement on hardness and ductility compare to those of unreinforced. Also, the specimens that stiff type Polyurea is sprayed on fiber sheet reinforcement has higher reinforcing effect than only sheet reinforced specimens. However, the specimens that and fiber sheet attached after polyurea applied on showed that the high toughness of fiber sheet restrains the ductile behavior of Polyurea due to the high ductility, thereby the specimen suffers the concentration of load, which leads the brittle fracture behavior.

A Novel Stiff Membrane Seesaw Type RF Microelectromechanical System DC Contact Switch on Quartz Substrate

  • Khaira, Navjot K.;Singh, Tejinder;Sengar, Jitendra S.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.3
    • /
    • pp.116-120
    • /
    • 2013
  • This paper proposes a novel RF MEMS dc-contact switch with stiff membrane on a quartz substrate. The uniqueness of this work lies in the utilization of a seesaw mechanism to restore the movable part to its rest position. The switching action is done by using separate pull-down and pull-up electrodes, and hence operation of the switch does not rely on the elastic recovery force of the membrane. One of the main problems faced by electrostatically actuated MEMS switches is the high operational voltages, which results from bending of the membrane, due to internal stress gradient. This is resolved by using a stiff and thick membrane. This membrane consists of flexible meanders, for easy movement between the two states. The device operates with an actuation voltage of 6.43 V, an insertion loss of -0.047 dB and isolation of -51.82 dB at 2 GHz.

The combined deterministic stochastic subspace based system identification in buildings

  • Bakir, Pelin Gundes
    • Structural Engineering and Mechanics
    • /
    • v.38 no.3
    • /
    • pp.315-332
    • /
    • 2011
  • The Combined Deterministic Stochastic Subspace based System Identification Technique (CDSSSIT) is a powerful input-output system identification technique which is known to be always convergent and numerically stable. The technique determines a Kalman state sequence from the projection of the output-input data. The state space matrices are determied subsequently from this Kalman state sequence using least squares. The objective of this paper is to examine the efficiency of the CDSSSIT in identifying the modal parameters (frequencies and mode shapes) of a stiff structure. The results show that the CDSSSIT predicts the modal parameters of stiff buildings quite accurately but is very sensitive to the location of sensors.

Efficient 3D Analysis of Building Structures with A Rigid Floor System (주상복합구조물의 효율적인 3차원 해석)

  • 황현식;이동근
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1996.10a
    • /
    • pp.239-246
    • /
    • 1996
  • Very stiff floor system in a residential-commercial building causes some problems in the numerical analysis procedure due to significant difference in stiffness with adjacent structural elements. Static analysis of structure with a stiff transfer-floor can be peformed approximately in two steps for upper and lower pons for the structure. However, it is impossible to perform dynamic analysis in two steps with separate models. An efficient method for dynamic analysis of a structure with a rigid floor system is proposed in this study. The matrix condensation technique is employed to reduce the degree of freedom for upper and lower parts of the structure and a beam elements with rigid bodies of both ends are introduce to model the rigid floor system. Efficiency end accuracy of the proposed method ore verified through analysis of several example structures.

  • PDF