• Title/Summary/Keyword: sterilization method

Search Result 274, Processing Time 0.038 seconds

Surface Characteristics of Dental Implant Fixture with Various Manufacturing Process (치과 임플란트 고정체의 여러 가지 제조공정과정에 따른 표면특성)

  • Jeong, Yong-Hoon;Moon, Young-Pil;Lee, Chung-Hwan;Yu, Jin-Woo;Choe, Han-Cheol
    • Journal of the Korean institute of surface engineering
    • /
    • v.43 no.1
    • /
    • pp.17-24
    • /
    • 2010
  • In this study, surface characteristics of dental implant fixture with various manufacturing process have been researched using electrochemical methods. The dental implant fixture was selected with 5 steps by cleaning, surface treatment and sterilization with same size and screw structure; the 1st step-machined surface, 2nd step-cleaned by thinner and prosol solution, 3th step-surface treated by RBM (resorbable blasting media) method, 4th step-cleaned and dried, 5th step-sterilized by gamma-ray. The electrochemical behavior of dental implant fixture has been evaluated by using potentiostat (EG&G Co, 2273A) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The corrosion surface was observed using field-emission scanning electron microscopy (FE-SEM) and energy dispersive x-ray spectroscopy (EDS). The step 5 sample showed the cleaner and rougher surface than step 3 sample. The step 5 sample of implant fixture treated by RBM and gamma sterilization showed the low corrosion current density compared to others. Especially, the step 3 sample of implant fixture treated by RBM was presented the lowest value of corrosion resistance and the highest value of corrosion current density. The step 3 sample showed the low value of polarization resistance compared to other samples. In conclusion, the implant fixture treated with RBM and gamma sterilization has the higher corrosion resistance, and corrosion resistance depends on the step of manufacturing process.

Safety of Temporary Use of Recycled Autoclaved Femoral Components in Infected Total Knee Arthroplasty: Confirming Sterility Using a Sonication Method

  • Park, Hyung-Jin;Kim, Hee-June;Kim, Shukho;Kim, Seong-Min;Mun, Jong-Uk;Kim, Jungmin;Kyung, Hee-Soo
    • Clinics in Orthopedic Surgery
    • /
    • v.10 no.4
    • /
    • pp.427-432
    • /
    • 2018
  • Background: The purpose of this study was to evaluate the usefulness of sonication technique for microbiological diagnosis and the sterility of the recycled autoclaved femoral components from infected total knee arthroplasty (TKA) using a sonication method. Methods: Nineteen femoral implants explanted from patients with infected TKA were sterilized with a standard autoclave method. Standard culture of the fluid before and after sonication of the sterilized implants was performed to detect pathogenic microorganisms. Additional experiments were performed to evaluate the sterility of the recycled implant by inducing artificial biofilm formation. Methicillin-resistant Staphylococcus aureus (MRSA) was inoculated into 10 implants and sterilization in a standard autoclave was performed, and then the fluid was cultured before and after sonication. Results: Two of the 19 sterilized implants were positive for growth of bacteria after sonication, whereas no growth was detected in the cultured fluid from the sterilized implants before sonication. The bacteria were Staphylococcus species in all two cases. In one of 10 implants inoculated with MRSA, the culture was positive for growth of bacteria both before and after sonication. However, Staphylococcus epidermidis was cultured from both occasions and thus this implant was thought to be contaminated. Conclusions: We found sonication for identification of pathogens could be helpful, but this finding should be interpreted carefully because of the possibility of contamination. Sterilization of an infected femoral implant with an autoclave method could be a good method for using the temporary articulating antibiotic spacer in two-stage revision arthroplasty.

Survey of Diease and Weed Control in Organic and Free-pesticide Cultivation of Chunnam Area 'Ssam' Vegegable (전남지역 쌈채류 무농약.유기재배농가의 잡초, 병해충관리 실태분석)

  • Lim, Kyeong-Ho;Kim, Sun-Guk;Choi, Kyong-Ju;Kim, Do-Ik;Kim, Seon-Gon;Lee, Yong-Hwan
    • Korean Journal of Organic Agriculture
    • /
    • v.15 no.1
    • /
    • pp.109-121
    • /
    • 2007
  • For developing standard method for diease, pest and weed control in environmental friendly 'Ssam' vegetable cultivation, this study was carried out to investigating agriculture material use in organic agriculture and no pesticide cultivation for lettuce, kale, leafy perilla and korean cabbage. The 28.6% of investigated farmer carried out seed sterilization by seed selection with salt solution and soaking in chitosan that not validated. For raising seedling periods, the 55.6% of farmer did not use environmental-friendly agriculture material for, diease control and the 50% of farmer used one time for. pest control. Therefore, the control of disease and pest could be achieved with one or two times use of environmental-friendly agriculture material. Seed sterilization was carried out by soil solar sterilization, one time per year in 71.4% of farmer. Weed was controled by black PE film for weed germination of furrow in many farmer, by man-power weeding for weed of ridge in 85% of farmer and by machine weeding and mulching in some farmer. During cultivation period, the major pest were Aphis gossypii in lettuce, Plutella xylostella in kale, Plutella xylostella and Phyllotreta striolata (Fabricius) in korean cabbage and Pyrausta panopealis (Walke) in feat perilla. The many farmers used environ-mental-friendly agriculture material for control of pest over 10 times for spring season, and more used sold materials in market than home-made materials. In result, it needs to develop standardized method and validate cultivation methods for control of disease and pest, and seed sterilization treatment environmental-friendly 'Ssam' vegetable.

  • PDF

Design of a shoe rack for effective sterilization and deodorization of the shoes contaminated by various bacteria (오염된 신발의 효율적인 살균과 탈취를 위한 신발장의 설계)

  • Lee, Sam-Cheol;Jang, Yong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.199-206
    • /
    • 2016
  • The aim of this study was to establish the optimal conditions to design a shoe rack that could effectively sterilize and deodorize shoes contaminated by various bacteria. The manufacture and evaluation of a shoe rock was conducted for one year from October 2014 to September 2015. The antibacterial efficacies were evaluated using Escherichia coli and Staphylococcus aureus by JIS Z 2801:2010. The deodorization efficiency was identified by the standard method for deodorization efficiency evaluation of an indoor air cleaner established by Korea Air Cleaning Association, SPS-KACA002-132:2006. The results showed that antibacterial evaluation showed more than 99.9% of the sterilization effects on Escherichia coli and Staphylococcus aureus after exposure to ultraviolet (UV) light for 30 seconds. The average deodorization efficiency for the test gases was 42.5%. The temperature in the shoes and in the shoe rack was lower than $40^{\circ}C$ and $25^{\circ}C$, respectively, when the UV lamp was turned on for 5 minutes and off for 25 minutes repeatedly. This was controlled by turning the UV lamp on and off to maintain the appropriate temperature in the shoes. In conclusion, the real deodorization efficiency is expected to be higher than the measured value because the internal volume of the shoe rack was smaller than the test chamber used to measure the deodorization efficiency. The deodorization effect could be increased further by the sterilization of bacteria causing bad odors in shoes. Further studies will be needed to determine the temperature deviations within the shoe rack to provide constant conditions.

Effect of Growth Medium and Extract Sterilization on a Seedling Bioassay of Alfalfa Autotoxicity (생장배지 및 추출액의 멸균이 알팔파 Autotoxicity 의 유묘 생물검정에 미치는 영향)

  • Chon, Sang-Uk;Nelson, C.Jerry;Han, Sung-Uk;Guh, Ja-Ock
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.2
    • /
    • pp.185-190
    • /
    • 1999
  • Autotoxic substance(s) from alfalfa(Medicago sativa L.) plants reduces germination and growth of adjacent new alfalfa after alfalfa. The autotoxic chemical(s) in alfalfa are clearly unknown. Our objective was to improve the sensitivity of an alfalfa seedling bioassay for evaluating autotoxic leaf extracts. We determined critical extract concentrations that inhibit seed germination and seedling growth, compared two different culture media, and evaluated the effects of extract sterilization on the sensitivity of the assay, by using streptomycin and autoclaving method. An agar medium in petri plate gave better responses of germination and seedling growth to the extracts than using filter paper in the plate. On agar medium, the concentration of extract required to reach 50% inhibition of root length was 2.7 g $kg^{-1}$, and of germination and hypocotyl length were 3.8 and 9.9 g $kg^{-1}$, respectively. Leaf extracts with 100 ppm streptomycin stimulated germination significantly compared to Leaf extract alone but reduced root length of control by 43%. Root length was more sensitive to the autotoxin(s) than was germination or hypocotyl length. These results suggest that agar medium mixed with extract and sterilization by autoclaving could be improved the consistency and precision of bioassay, and that root length was the best parameter of autotoxic effect of alfalfa leaf extract.

  • PDF

Clinical Efficacy of Latex Cover for Dental Handpiece (치과 핸드피스용 감염방지구의 임상적 효용성)

  • Lee, Ki-Ho;Paek, Dong-Heon
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.3
    • /
    • pp.237-245
    • /
    • 2009
  • The purpose of this study was to investigate the clinical efficacy of latex cover developed for dental handpiece on contamination of microorganisms during dental treatment and to determine whether it can be an alternative to conventional sterilization such as autoclaving. E. fecaelis was used as a experimental microorganism instead of oral flora. Experimental bowl with 2 cm of rectangular cavity was fabricated for handpiece operating instead of oral cavity. Latex covers ($Orokeeper^{(R)}$, Orobiotech Co., Korea) and several handpieces were used after sterilization by autoclave. Four experiments were performed to evaluate bacterial contamination related with (1) various parts of dental handpiece, (2) swabbing time with alcohol sponge, (3) postoperative air-water spraying time and (4) consecutive use of latex covers without autoclaving. The results show that face of handpiece uncovered with latex cover was severely contaminated than the covered area and that most bacteria were removed by swabbing face and head area of dental hand-piece and by air-water spraying more than 15 seconds nearly up to the level of sterilization. Conclusively it can be suggested that use of latex cover for handpiece during dental procedure, swabbing with alcohol sponge is air-water spraying for more than 15 seconds after use of dental handpiece should be very useful and practical for prevention of cross infection and should be an alternative method for the sterilization of dental handpiece under some difficult situations not being able to sterilize a handpiece with autoclave.

Study on Surface Plasmon Electrode Using Metal Nano-Structure for Maximizing Sterilization of Dielectric Discharge (유전체 방전 살균 극대화를 위한 금속 나노 구조를 이용한 표면 플라즈몬 전극에 관한 연구)

  • Ki, Hyun-Chul;Oh, Byeong-Yun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.2
    • /
    • pp.80-84
    • /
    • 2018
  • In this study, we investigated plasmon effects to maximize the sterilization of dielectric discharge. We predicted the effect using the finite difference time domain (FDTD) method as a function of electrode shape, size, and period. The structure of the electrode was designed with a thickness of 100 nm of silver nanoparticles on a glass substrate, and was varied according to the shape, size, and period of the electrode hole. Based on the results, it was confirmed that the effect of plasmons was independent of the shape of the electrode hole. It was thus confirmed that the plasmon effect depended only on the size and period of the holes. Further, the plasmon effect was affected by the size rather than period of the holes. Because the absorption of light by the metal varied according to the size of the hole, the plasmon effect generated by the absorption of light also varied. The best results were obtained when the radius and period of the electrode holes were $0.1{\mu}m$ and $0.4{\mu}m$, respectively.

Energy self-sufficient electrolysis apparatus for sterilization of portable toilet in small vessels (소형선박에 설치 가능한 해상기인 오염원 멸균용 에너지 자급형 전기분해 장치 개발)

  • Oh, Seung-Won;Hahn, Min-Soo;Choi, Hae-Wook
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.48 no.3
    • /
    • pp.269-276
    • /
    • 2012
  • Marine caused pollution occurs mostly near coastal area and its main cause was known to be human feces issued from small vessels. To sterilize liquid pollutants from portable toilets of small vessels, an electrolysis treatment is judged to be the most economic and stable method considering an environment of its use. In this paper, we presents an electrolysis apparatus which is the most appropriate for sterilizing pollutants from portable toilets of small vessels and derives the minimum operating time of the apparatus for sterilizing norovirus which is a main target of marine caused pollution sources. In order to utilize renewable energy, we designed an apparatus which generates a renewable energy from solar cells. As a result, we could confirm the applicability of the proposed system with the results from experiments in three cases of different weather conditions.

Air sterilization using filter and air ions: A review (필터와 이온을 이용한 공기살균법 연구동향)

  • Woo, Chang Gyu;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo
    • Particle and aerosol research
    • /
    • v.12 no.3
    • /
    • pp.73-80
    • /
    • 2016
  • Bioaerosol inactivation becomes important as people recognize the significance on the health effects of bioaerosols. There are several ways to inactivate such bioaerosols such as antimicrobial filters, UV, etc. For the on-filter-inactivation, proper antimicrobial materials coating should be applied. Recently, air ions are adopted to effectively reduce germ and virus activity. Limitations arise when each method is applied separately. Coating materials can experience chemical instability over time and temperature. Ionizers can generate ozone to prepare high ion concentrations. Combinations of developed techniques to enhance the inactivation efficiency were suggested. Researches on the air sterilization are reviewed and outlook is highlighted. Proper techniques such as combinations of filter material coating and air ion generation can be used to make air quality better for human living.

A study on the design development of a domestic disinfector using UV LED (UV LED를 이용한 가정용 소독기의 디자인 개발에 관한 연구)

  • Zhu, Wang;Sheng, Ying;Kang, Seung-Min;Jee, Moon-Hwan
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.29 no.6
    • /
    • pp.264-269
    • /
    • 2019
  • The design for household sterilizer applying UV LED was studied. Based on UV LED sterilization distance and time data, the concept of home disinfectioner design was presented. Using technologies such as computer aided design software, 3D printing and laser cutting, etc., three different UV LED operating method models were produced. The final design was derived by conducting an analysis of the product's merits and demerits on the three plans from the result of each model.