Browse > Article
http://dx.doi.org/10.5695/JKISE.2010.43.1.017

Surface Characteristics of Dental Implant Fixture with Various Manufacturing Process  

Jeong, Yong-Hoon (Department of Dental Materials & Research Center of Nano-Interface Activation for Biomaterials, School of Dentistry, Chosun University)
Moon, Young-Pil (Department of Dental Materials & Research Center of Nano-Interface Activation for Biomaterials, School of Dentistry, Chosun University)
Lee, Chung-Hwan (Department of Prosthodontics, School of Dentistry, Chosun University)
Yu, Jin-Woo (Shingyeong University)
Choe, Han-Cheol (Department of Dental Materials & Research Center of Nano-Interface Activation for Biomaterials, School of Dentistry, Chosun University)
Publication Information
Journal of the Korean institute of surface engineering / v.43, no.1, 2010 , pp. 17-24 More about this Journal
Abstract
In this study, surface characteristics of dental implant fixture with various manufacturing process have been researched using electrochemical methods. The dental implant fixture was selected with 5 steps by cleaning, surface treatment and sterilization with same size and screw structure; the 1st step-machined surface, 2nd step-cleaned by thinner and prosol solution, 3th step-surface treated by RBM (resorbable blasting media) method, 4th step-cleaned and dried, 5th step-sterilized by gamma-ray. The electrochemical behavior of dental implant fixture has been evaluated by using potentiostat (EG&G Co, 2273A) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The corrosion surface was observed using field-emission scanning electron microscopy (FE-SEM) and energy dispersive x-ray spectroscopy (EDS). The step 5 sample showed the cleaner and rougher surface than step 3 sample. The step 5 sample of implant fixture treated by RBM and gamma sterilization showed the low corrosion current density compared to others. Especially, the step 3 sample of implant fixture treated by RBM was presented the lowest value of corrosion resistance and the highest value of corrosion current density. The step 3 sample showed the low value of polarization resistance compared to other samples. In conclusion, the implant fixture treated with RBM and gamma sterilization has the higher corrosion resistance, and corrosion resistance depends on the step of manufacturing process.
Keywords
Dental implant; Corrosion resistance; RBM; Surface treatment; Gamma-ray;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 W. G. Kim, C. H. Lee, C. H. Chung, H. C. Choe, J. Kor. Inst. Surf. Eng., 43(1) (2010) In press.   과학기술학회마을
2 D. M. Brunette, P. Tengvall, M. Textor, P. Thomsen, Titanium in Medicine, Springer, Berlin (2001).
3 H. Hamanaka, Titanium and Titanium Alloys: Dental Materials of Preference in the 21th Century. in: Proceedings of the Fifth International Symposium on Titanium in Dentistry, Society for Titanium Alloys in Dentistry, (2001) 1.
4 L. R. Rubin, Biomaterials in Reconstructive Surgery. C. V. Mosby, St. Louis (1983).
5 Z. Schwarts, K. Kieswetter, D. D. Dean, B. D. Boyan, J. Periodontal Res., 32 (1997) 166.   DOI
6 N. Ibris, J. C. M. Rosca, J. Electro. Chem., 526 (2002) 53.   DOI
7 E. Obayashi, T. J. Wang, H. Doi, T. Yoneyama, H. Hamanaka, Mater Sci.:Mater. Med., 9 (1998) 567.   DOI
8 P. Binon, Implant Dentistry, 5 (1996) 235.   DOI
9 A. Balfour, R. Gray, J. Prosthet. Dent., 73 (1995) 36.   DOI
10 B. Feng, J. Y. Chen, S. K. Qi, L. He, J. Z. Zhao, X. D. Zhang, J. Mater. Sci. Mater. Med., 13 (2002) 457.   DOI
11 R. R. Winston, N. D. Greene, Corros. Sci., 9 (1969) 755.   DOI
12 S. Hobo, E. Ichida, L. T. Garcia, Osseointegration and Occlusal Rehabilitation. Quintessence Int., Tokyo (1989).
13 K. Lee, H. C. Choe, Y. M. Ko, The J. Korean Res. Soc. Dent. Mater., 35 (2008) 285.
14 D. M. Brunette, P. Tengvall, M. Textor, P. Thomsen, Titanium in Medicine. Engineering Materials, Springer, (2001).
15 D. D Deligianni, N. Katsala, S. Ladas, D. Sotiropoulou, J. Amedee, Y. F. Missirlis, Biometer. Res., 32 (2001) 166.
16 A. F. Recum, Biomaterials, 9 (1990) 297.
17 B. Kasemo, J. Lausmaa, Metal Selection and Surface Characteristics. Quintessence, Chicago, (1985) 99.
18 A. K. Shukla, R. Balasubramaniam, S. Bharagava, J. Alloys Comp., 24 (2005) 144.