• Title/Summary/Keyword: stereopsis

Search Result 43, Processing Time 0.027 seconds

Edge Extraction Method Based on Color Image Model (컬러 영상 모델에 기반한 에지 추출기법)

  • Kim Tae-Eun
    • Journal of Digital Contents Society
    • /
    • v.4 no.1
    • /
    • pp.11-21
    • /
    • 2003
  • In computer vision, the goal of stereopsis is to determine the surface structure of real world form two or more perspective views of scene. It is similar to human visual system. We can avoid obstacles, recognize objects, and manipulate machine using three-dimensional information. Until recently, only gray-level images have been used as input to computation for depth determination, but the availability of color can further enhance the performance of computational stereopsis. There are many models to provide efficient color system. The simplest model, RGB model treats color as if it were composed of separate entities. Each color channel is processed individually by the same stereopsis module as used in the gray-level model. His Model decouples intensity component from color information. So it can deal with color properties without defect intensity information. Opponent color model is based on human visual system. In this model, the red-green-blue colors are combined into three opponent channels before further processing.

  • PDF

Clinical Evaluation on Variation of Face Form Angle of Eyewear (안경 안면각 변화에 대한 임상적 고찰)

  • Ko, Da-young;Kim, Ki-hong;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.477-484
    • /
    • 2015
  • Purpose: This study was investigated to evaluate the effect of the variation of the face form angle(FFA) of spectacle frame on the visual acuity and the visual function. Methods: The visual acuity, the contrast sensitivity, the stereopsis, and the phoria were measured with the spectacle frame whose the FFA is at $5^{\circ}$ and $25^{\circ}$ and the surveys were conducted on subjective symptoms. Here, 30 adults (14 men and 16 women, average age:$25.46{\pm}3.9$), who did not have ocular diseases and were fully corrected in case of having had refractive error, were to act as experimental subjects for this measurement. Results: The visual acuity and the contrast sensitivity was decreased and the phoria was tended to increase to the esophoria direction at the FFA $25^{\circ}$ than at the FFA $5^{\circ}$. The stereopsis was significantly reduced at the FFA $25^{\circ}$ than at the FFA $5^{\circ}$. Also when the FFA was larger, the higher the degree of refractive error was, the more the increase of the subjective symptoms such as being blurred characters, being disturbed head, and having sore eyes was, which reveals a statistically significant correlation between them. Conclusions: If the FFA increases, the visual acuity, the contrast sensitivity and the stereopsis was found to decrease and the phoria to increase to the esophoria direction. Therefore it shows that the variation of the FFA of spectacle frame can influence the visual acuity and the visual function.

A review of space perception applicable to artificial intelligence robots (인공지능 로봇에 적용할 수 있는 공간지각에 대한 종설)

  • Lee, Young-Lim
    • Journal of Digital Convergence
    • /
    • v.17 no.10
    • /
    • pp.233-242
    • /
    • 2019
  • Numerous space perception studies have shown that Euclidean 3-D structure cannot be recovered from binocular stereopsis, motion, combination of stereopsis and motion, or even with combined multiple sources of optical information. Humans, however, have no difficulties to perform the task-specific action despite of poor shape perception. We have applied humans skill and capabilities to artificial intelligence and computer vision but those machines are still far behind from humans abilities. Thus, we need to understand how we perceive depth in space and what information we use to perceive 3-D structure accurately to perform. The purpose of this paper was to review space perception literatures to apply humans abilities to artificial intelligence robots more advanced in future.

A study on Monovision of Fitting soft contact lenses for College students (대학생에게 유도된 소프트 콘택트렌즈 모노비전에 관한 연구)

  • Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.181-188
    • /
    • 2004
  • Monovision is defined as correcting one eye for distance vision and the other eye for near vision. Single-vision contact lenses are used for each eye. The patient selectively suppresses one eye while using the other eye. This study was performed to measure binocular function and patient satisfaction with monovision induced by adding +3.00D to spectacle prescription for distance vision in nonpresbyopic students. This study comprised 144 nonpresbyopic students with monovision induced by adding +3.00D to spectacle prescription. Monovision was induced by undercorrecting the nondominant eye by adding 3.00 diopters for near vision and correcting the dominant eye with emmetropia for distance vision. For research of the binocular function on Monovision. This study was tested the obstacle course, water pouring test, catching and throwing, bead classification including the stereopsis test. These tests were comparative to the normal binocular state. As a results, the stereopsis have a significant reductions in Monovision. There was no significantly difference between monovision group and control group in monovision exercise (obstacle course, water pouring test, catching and throwing, and bead sorting) at near and distance. This study indicates that monovision is an effective and reasonable therapeutic modality for correcting presbyopia. By the application of above methods, this study could be used the student for the practical practice and understand on the Monovison.

  • PDF

Change of Fixation Disparity and Accommodation when the Fusion Contrast Varied (융합대비에 따른 주시시차와 조절의 변화)

  • Seo, Jae-Myoung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: To study the change of fixation disparity and accommodation as fusion contrast is deteriorated. Methods: 16 subjects who had above 20/20 and stereopsis took part. Monocular and binocular refraction were done with Zeiss Polatest Classic whereas the critical angle for stereopsis was done with TNO. A computer programmed with Random-Dot stereogram and vernier test managed a precise change of the fusion contrast and exposure time. Results: The fixation disparity was influenced by reduction of fusion contrast and had tendancy to exophoria (p=0.0004), especially it is considerably higher when uncrossed disparity was shown to exophoric subjects. Although accommodation was not influenced by a change of fusion contrast (p=0.803), vernier acuity was influenced (p=0.0000). Conclusions: Exophoric trend arose as the fusion contrast was reduced, nevertheless there was no accommadative change.

  • PDF

Time-dependent Changes of Visual Acuity After Alcohol Ingestion (음주 후 시간경과에 따른 시력의 변화)

  • Kim, Sang-Yoeb;Lee, Sun Haeng;Moon, Byeong-Yeon;Yu, Dong-Sik;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.59-62
    • /
    • 2008
  • Purpose: This study was designed to investigate the time-dependent changes of visual acuity after alcohol ingestion. Methods: Both the subjective and objective refraction, distant contrast sensitivity, and three needle tests were carried out at 1 and 3 hours after alcohol ingestion. Results: It was found that the degree of myoptization increased as the blood alcohol level increased in the range of average -0.25D ~ -0.35D when tested 1 and 3 hours after alcohol ingestion. Under the same test conditions the increase in blood alcohol resulted in the reduction in the function of dynamic stereopsis. However, the variation in contrast sensitivity was found to be insignificant for all spatial frequencies. Conclusions: The optician has to be well aware of the fact that alcohol could affect the visual acuity and functional tests, therefore inquiring of the alcohol ingestion prior to visual test can be necessary.

  • PDF

3D Image Conversion of 2D Still Image based-on Differential Area-Moving Scheme (차등적 영역 이동기법을 이용한 2차원 정지영상의 3차원 입체영상 변환)

  • 이종호;김은수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.11A
    • /
    • pp.1938-1945
    • /
    • 2001
  • In this paper, a new scheme for image conversion of the 2D input images into the stereoscopic 3D images by using differential shifting method is proposed. First, the relative depth information is estimated by disparity and occlusion information from the input stereo images and then, each of image objects are segmented by gray-level using the estimated information. Finally, through the differential shifting of the segmented objects according to the horizontal parallax, a stereoscopic 3D image having optimal stereopsis is reconstructed. From some experimental results, it is found that the horizontal disparity can be improved about 1.6dB in PSNR for the reconstructed stereo image using the proposed scheme through comparing to that of the given input image. In the experiment of using the commercial stereo viewer, the reconstructed stereoscopic 3D images, in which each of the segmented objects are horizontally shifted in the range of 4 ∼5 pixels are also found to have the mast improved stereopsis.

  • PDF

Large scale interactive display system for touch interaction in stereopsis (입체 영상에서 터치 인터랙션을 위한 대규모 인터랙티브 디스플레이 시스템)

  • Kang, Maeng-Kwan;Kim, Jung-Hoon;Jo, Sung-Hyun;Joo, Woo-Suck;Yoon, Tae-Soo;Lee, Dong-Hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.252-255
    • /
    • 2010
  • In this thesis, it suggests large scale interactive display system which is able to various touch interaction and bases on infrared LED BAR and using 3D. Interaction layer formed on space from screen which is able to feel 3D using suggested IR LED BAR. It gets the image in real time what is composed in interaction section using infrared camera with band pass filter. The image finds touch interaction coordinate through image processing module and saves as packet. It send packet to server through network data communication. It analyze packet by metaphor analysis module and save as metaphor event and send it to contents. On contents, it practices to metaphor event result in real time so it makes use touch interaction in stereopsis. According to this process, it does not need touch the screen at firsthand but it is possible system and touch interaction so touch interaction is possible while use 3D.

  • PDF

A Convergent Approach to Gain a Better Understanding of Alzheimer's Disease: Stereoscopic Vision (융복합적 접근을 통한 알츠하이머형 치매의 이해 증진 : 양안 지각)

  • Kim, Nam-Gyoon;Lee, Ho-Won
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.5
    • /
    • pp.103-110
    • /
    • 2019
  • The present study investigated the effects of AD on stereoscopic vision. Sixty participants (20 AD patients, 20 mild cognitive impairment patients, 20 healthy elderly controls) participated in the study. Two cubes, one on the left and the other on the right of the center of the monitor, appeared at varying distances from the observer with their relative distances controlled in two disparity conditions (absolute vs relative disparity) combined with two disparity directions (crossed vs uncrossed disparity). Participants identified the object that appeared closer to them. Results demonstrated comparable performance with all three groups performing accurately, suggesting that the effect of AD on stereopsis is negligible. Discussion focused on brain pathology affected by AD involving high level visual processing.

The Clinical Examination of Netspeg Lens for Good Visual Acuity (시력 개선을 위한 Netspeg 렌즈의 임상적 검증)

  • Kim, Douk-Hoon;Bae, Han-Young;Kim, Sun-Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.281-291
    • /
    • 2006
  • The aim of this study was performed the clinical test using Netspeg lens for good visual acuity on subjects with abnormal refraction status. The subjects of one hundreds adults (fifty males, fifty females, mean=21 years, range=19 to 24) were recorded. The subjects were researched the history including the systemic health, medication, genetics, allergy, systemic disease and ocular disease. The refraction test was recorded the monocular and binocular using objective method. Visual acuity was performed the binocular status using the Netspeg lens and CR-39. Stereopsis test was performed the titmus fly and TNO at near distance using Netspeg lens and CR-39. The P-VEP test was used the 16 pattern size(Bausch Lomb, production in USA) with three channels. Also Subjects viewed the p-vep stimulus with binocular vision through the corrected visual acuity using the Netspeg lens and CR-39. The contrast sensitivity test was performed the contrast sensitivity chart(pelli-Robertson, USA) at 1m distance using the Netspeg lens and CR-39. The ultrastructure of surface on the Netspeg lens and CR-39 was observed the SEM(JMS-5800, made in Japan). The results of this study was as follows: 1. In corrected visual acuity of abnormal refraction using the Netspeg lens and CR-39, the Netspeg lens wearer were acquired the good visual field and clear visual acuity comparative to CR-39 wearer in the subject vision test. however the comfort of visual acuity was similar results in the Netspeg lens and CR-39. Also the subjects of Netspeg lens wearer was good visual acuity more than CR-39 wearer and in the analysis of P-VEP, the amplitude of wave on Netspeg lens used appears to be better through the CR-39(p>0.5). Besides, on the contrast sensitivity, the Netspeg lens wearer was good results than CR-39. The value on stereopsis with TNO by Netspeg lens wearer was better than CR-39 in results. However, in the stereopsis test with Titmus, the Netspeg lens and CR-39 wearer was similar results. 2. The ultrastructure of Netspeg lens surface was the smooth and fine shape more than CR-39. Also, Netspeg lens have a fine line structure in ultrastructure. In conclusion, the results of this study conformed that the surface ultrastructure of Netspeg lens used is more specific pin hole design structure than CR-39. This study indicated that the vision of Netspeg lens used have a better than CR-39 in the corrected visual acuity for abnormal refraction eye. Therefore, In this paper, we suggested that the ultrastructure and line structure of Netspeg lens was related to good visual function. However the visual function of the aspheric Netspeg and ultra waterproof Netspeg lens was similar results.

  • PDF