The Clinical Examination of Netspeg Lens for Good Visual Acuity

시력 개선을 위한 Netspeg 렌즈의 임상적 검증

  • Received : 2006.06.03
  • Published : 2006.07.31

Abstract

The aim of this study was performed the clinical test using Netspeg lens for good visual acuity on subjects with abnormal refraction status. The subjects of one hundreds adults (fifty males, fifty females, mean=21 years, range=19 to 24) were recorded. The subjects were researched the history including the systemic health, medication, genetics, allergy, systemic disease and ocular disease. The refraction test was recorded the monocular and binocular using objective method. Visual acuity was performed the binocular status using the Netspeg lens and CR-39. Stereopsis test was performed the titmus fly and TNO at near distance using Netspeg lens and CR-39. The P-VEP test was used the 16 pattern size(Bausch Lomb, production in USA) with three channels. Also Subjects viewed the p-vep stimulus with binocular vision through the corrected visual acuity using the Netspeg lens and CR-39. The contrast sensitivity test was performed the contrast sensitivity chart(pelli-Robertson, USA) at 1m distance using the Netspeg lens and CR-39. The ultrastructure of surface on the Netspeg lens and CR-39 was observed the SEM(JMS-5800, made in Japan). The results of this study was as follows: 1. In corrected visual acuity of abnormal refraction using the Netspeg lens and CR-39, the Netspeg lens wearer were acquired the good visual field and clear visual acuity comparative to CR-39 wearer in the subject vision test. however the comfort of visual acuity was similar results in the Netspeg lens and CR-39. Also the subjects of Netspeg lens wearer was good visual acuity more than CR-39 wearer and in the analysis of P-VEP, the amplitude of wave on Netspeg lens used appears to be better through the CR-39(p>0.5). Besides, on the contrast sensitivity, the Netspeg lens wearer was good results than CR-39. The value on stereopsis with TNO by Netspeg lens wearer was better than CR-39 in results. However, in the stereopsis test with Titmus, the Netspeg lens and CR-39 wearer was similar results. 2. The ultrastructure of Netspeg lens surface was the smooth and fine shape more than CR-39. Also, Netspeg lens have a fine line structure in ultrastructure. In conclusion, the results of this study conformed that the surface ultrastructure of Netspeg lens used is more specific pin hole design structure than CR-39. This study indicated that the vision of Netspeg lens used have a better than CR-39 in the corrected visual acuity for abnormal refraction eye. Therefore, In this paper, we suggested that the ultrastructure and line structure of Netspeg lens was related to good visual function. However the visual function of the aspheric Netspeg and ultra waterproof Netspeg lens was similar results.

본 연구는 굴절이상을 가진 피검자의 시력 개선을 위한 Netspeg 렌즈의 임상적 검증을 하였다. 피검자는 성인 100명(남성 50인, 여성 50명; 평균 21세, 연령은 19세와 24세 사이)의 200개 눈을 대상으로 검사하였다. 피검자는 전신건강, 약물복용, 유전병, 알레르기, 전신질환 그리고 안질환을 포함하는 문진 등을 조사하였다. 굴절검사는 객관적인 방법을 사용해서 단안과 양안을 기록하였다. 시력측정은 양안에 Netspeg 렌즈와 CR-39를 착용하여 실시하였다. 입체시 검사는 Netspeg 렌즈와 CR-39를 착용해서 근거리에서 Titmus fly와 TNO를 사용해서 하였다. P-VEP 검사는 3채널의 16 pattern size(Bausch Lomb, production in U.S.A.)를 사용하였다. 피검자는 Netspeg 렌즈와 CR-39 렌즈를 사용하여 교정된 시력을 통해서 양안으로 patten 자극을 사용하였다. 역시 피검자는 Netspeg 렌즈와 CR-39 렌즈를 사용하여 교정된 시력을 통해서 양안시로 P-VEP 자극을 본다. 대비감도 검사는 대비감도 차트(Pelli-Robertson, made in USA)를 이용해서 1m 거리에서 Netspeg 렌즈와 CR-39를 장용해서 실시하였다. Netspeg 렌즈와 CR-39의 표면 미세구조는 SEM(JMS-5800, made in Japan)을 이용해서 관찰하였다. 연구의 결과는 다음과 같다. 1. Netspeg 렌즈와 CR-39를 사용한 비정상 굴절 피검자의 교정된 시력에서 Netspeg 렌즈를 착용한 피검자는 시각의 주관적 테스트에서 CR-39 착용자에 비해서 좋은 시야와 깨끗한 시력을 얻었다. 그러나 시력의 편안함은 Netspeg 렌즈와 CR-39는 비슷한 결과를 가졌다. 역시 Netspeg 렌즈 착용자의 피검자는 CR-39보다 좋은 시력을 가졌다. 한편 P-VEP 분석에서는 사용된 Netspeg 렌즈 착용자의 파의 진폭은 CR-39보다 더 증가한 모습을 가졌다(p>0.5). 또한 대비감도 검사에서 Netspeg 렌즈 착용자는 CR-39보다 좋은 결과를 가졌다. Netspeg 렌즈를 착용한 피검자의 TNO 입체시 검사 값은 그 결과가 CR-39보다 좋았다. 그러나 Titmus 입체시 검사에서는 Netspeg 렌즈와 CR 착용자는 비슷한 검사 결과를 나타내었다. 특히 초경발수 Netspeg 렌즈와 비구면 Netspeg 렌즈는 시기능 테스트에서 다소 비슷한 결과를 가졌다. 2. Netspeg 렌즈 표면의 미세구조는 CR-39보다는 매끄럽고 섬세한 구조와 선을 가졌다. 역시 Netspeg 렌즈는 미세구조에서 섬세한 선상 구조를 가졌다. 결론적으로 이 연구의 결과는 사용된 Netspeg 렌즈의 표면 미세구조는 CR-39보다는 더욱 특수한 pinhole 디자인 구조를 나타내었다. 이 연구는 사용된 Netspeg 렌즈의 시각은 비정상 굴절 눈을 위한 교정된 시력에 CR-39보다 좋은 것을 나타낸다. 따라서 저자들은 Netspeg 렌즈의 미세구조와 선 구조는 좋은 시기능과 관계되었을 것으로 추측된다. 그러나 비구면 Netspeg 렌즈와 초경발수 Netspeg 렌즈의 시기능에 대한 결과는 비슷하였다.

Keywords

Acknowledgement

Supported by : 마산대학