• Title/Summary/Keyword: statically-balanced

Search Result 7, Processing Time 0.021 seconds

Haptic Device For Haptic Interaction With Virtual Environment (가상환경과 촉감적 상호작용을 위한 햅틱 디바이스)

  • 정영훈;이재원;주해호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.27-30
    • /
    • 2000
  • In this paper, we determine the design criteria of haptic device considering the human haptic system and determine the design specifications. We developed a new 2DOF haptic device based on the specifications. It has the wide workspace, statically-balanced, constant inertia matrix, well-conditioned Jacobian matrix and so on. There also is not singularity point within workspace of the device. We show that it has better performance than other 2DOF haptic device in the many aspects.

  • PDF

The Plantar Pressure Comparison between the Curved Rear Balance Shoes and Normal Shoes (유선형 후방 밸런스 신발과 일반 신발의 족저압 비교)

  • Kim, Youn-Joung;Chae, Woen-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.173-180
    • /
    • 2007
  • The purpose of study was to compare plantar pressure during walking wearing the curved rear balance and normal shoes. Twelve university students(height: $177.2{\pm}4.6cm$, weight: $68.4{\pm}5.8kg$, age: $26.2{\pm}1.6yrs.$) who have no known musculoskeletal disorders were recruited as the subjects. Plantar foot pressures were evaluated using the Tekscan's pressure measurement systems while subjects walked upright position wearing the curved rear balance and normal shoes in random order at a speed of 1.3 m/s. The contacting dimension, the mean plantar pressure, and the peak plantar pressure were determined for each trial. For each dependent variable, paired t-test was performed to test if significant difference existed between shoe conditions (p<.05). As a result, the curved rear balanced shoes showed as large as 38 up to 50 % of area at the rear side of feet than the normal shoes when measuring the contact area with upright position. In the distribution of average pressure, the curved rear balanced shoes displayed fairly low pressure compared to other normal shoes in general except for one area, which is M2, and especially, the measured pressures at the both rear (M1) and middle (M5) side of feet were low and statically significant. The contact area of the curved rear balanced shoes when walking was significantly larger at the rear (M1) and fore (M6, M7) side of feet. When considering pressure distribution at walking, low pressure was detected at the rear side of feet with the curved rear balanced shoes and at the fore side of feet for other normal shoes. The results showed that the contacting dimension of the curved rear balance shoes that acts between shoes and feet was higher than the corresponding value for the normal shoes in general; therefore it would reduce the pressure to the feet by allowing the each sole of the foot on the ground evenly.

Dynamics of a Micro Three-axis Ring Gyroscope Considering Electrode Effects (전극 효과를 고려한 마이크로 3축 링 자이로스코프의 동역학)

  • 김창부;강태민
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.1
    • /
    • pp.64-72
    • /
    • 2004
  • In this paper. we analyse and present electro-mechanical dynamic characteristics of a micro-machined vibrating silicon ring gyroscope which can measure angular velocities about three orthogonal axes. The ring gyroscope has a ring connected to the gyroscope main body by support-ligaments which are arranged with cyclic symmetry. The natural modes of its vibration can be distinguished into the in-plane motion and the out-of-plane motion which are coupled by the gyro-effect due to the rotation of the gyroscope main body. The motions of the ring are electro-statically derived. sensed and balanced by electrodes. The equations of motion are formulated. The measuring method of angular velocities by force-to-rebalance is presented. The dynamic characteristics of a ring gyroscope are calculated and compared.

Dynamics of a Micro Three-Axis Ring Gyroscope Considering Electrode Effects (전극 효과를 고려한 마이크로 3축 링 자이로스코프의 동역학)

  • 강태민;김창부
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.970-976
    • /
    • 2003
  • In this paper, we analyse and present electro-mechanical dynamic characteristics of a micro-machined vibrating silicon ring gyroscope which can measure angular velocities about three orthogonal axes. The ring gyroscope has a ring connected to the gyroscope main body by support-ligaments which are arranged with cyclic symmetry. The natural modes of its vibration can be distinguished into the in-plane motion and the out-of-plane motion which are coupled by the gyro-effect due to the notation of the gyroscope main body. The motions of the ring are electro-statically derived, sensed and balanced by electrodes. The equations of motion are formulated. The scheme of angular velocities sensing by force-to-rebalance method is presented. The dynamic characteristics of a ring gyroscope are calculated and compared.

  • PDF

Correlation between balance and thickness of abdominal and quadriceps muscles (복부근육 및 넙다리네갈래근과 균형의 상관관계)

  • Seok-hyun Kim;Jae-hong Kim;Jeongwoo Jeon;Jiheon Hong;Jaeho Yu;Jinseop Kim;Seong-Gil Kim;Dongyeop Lee
    • Journal of Advanced Technology Convergence
    • /
    • v.2 no.2
    • /
    • pp.31-38
    • /
    • 2023
  • This study compares the correlation between muscle thickness (abdominal, quadriceps muscle) and how the muscle thickness affects the static balance when the static balance is measured in a standing position. The subjects of study were to select 29 subjects to find out what relationship muscle thickness had on the static balance when measuring muscle thickness and static balance. rectus femoris muscle thickness showed a significant correlation in statically balanced weight distribution index. In this study, only healthy men in their twenties were selected, and the results could not be generalized to other age groups. As a limitation of this study, muscle strength and peripheral vision were not measured, so it seems difficult to express the accuracy of the study and generalize the results. In future studies, the number of subjects and muscle strength should be measured to proceed with the study.

The Comparison between Single Shot Turbo Spin Echo and B-FFE (Balanced Turbo Field-echo) in the Differentiation of Focal Liver Lesions (국소 간병변 감별에서 단발고속스핀에코 기법과 균형항정상 태세차를 이용한 고속영역 기법간의 비교)

  • Kim, Young-Chul;Kim, Myeong-Jin;Cha, Seung-Whan;Chung, Yong-Eun;Han, Kwang-Hyup;Choi, Jin-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.39-48
    • /
    • 2007
  • Purpose : To determine the diagnostic accuracy of four different sequences : moderately T2 weighted, two heavily T2-weighted single shot turbo spin-echo sequence and breath-hold axial-2D balanced turbo field-echo sequence(bFFE) for characterization of focal lesions. Materials and Methods : During the 3-month period between June and August 2005, seventy-six patients were proved to have ninety-three focal hepatic lesions on MR imaging. The patients consisted of 49 men and 27 women (age range, 15-75 years; mean age, 56.23 years). All MR images were acquired on a 1.5-T MR using the following sequences: 1. A breath-hold axial T2-weighted single shot turbo spin-echo sequence, 2. a breath-hold axial-2D balanced turbo field-echo sequence. Two radiologists performed quantitative analysis. Another radiologist measured the lesion-to-liver contrast-to-noise ratio at the region-of-interest in the four sequences. Results : There was no significant difference in inter-observer variability between the four sequences. The accuracy for both cyst and malignancy of moderate T2 weighted MRI (echo time: 80 msec) was also highest. There was significant difference for lesion characterization between moderate T2 weighted MRI and balanced steady state procession (p-value: 0.004) in the second reader. For longer echo time, the CNR of cystic lesions were markedly increased in comparison to lesions of other component. Conclusion : The accuracy and inter-observer variability of single shot turbo spin echo T2 weighted sequence was higher than bFFE. Although there was no statically significant difference, moderate T2 weighted MRI (echo time: 80 msec) was more accurate than heavily T2 weighted sequence (echo time: 300 msec). If the results for lesion characterization is equivocal in TE 80, the addition of heavily T2 weighted MRI (echo time: 180 msec) can be helpful.

  • PDF

Relationships of Changing Social Atmosphere, Lifestyle and Bone Mineral Density in College Students (대학생의 골밀도와 사회분위기 및 생활습관과의 관계)

  • Lee, In-Ja;Ko, Yo-Han;Kim, Chung-Kyung;Kim, Hee-Sol;Park, Da-Jeong;Yoon, Hyeo-Min;Jeong, Yu-Jin
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.263-271
    • /
    • 2013
  • The decrease of bone mineral density gives rise to the outbreak of osteopenia and makes the possibility of a bone fracture. It makes health problems in society. It's very important to prevent osteopenia in advance. Also it's critical to prevent and take care of it in adolescent because it's the most developing period comparing to middle ages because that bone mineral density decreases. There are genetic, physical and enviromental factors that affect bone mineral density. Recently, a lifestyle and eating habits are also changing as the society atmosphere is gradually doing. This study have shown that 134 women and 75 men was chosen and responded to the survey of measuring bone mineral density and investigating a lifestyle. The measure of bone mineral density is to use Dual energy X-ray absorptiometry(DEXA) and check femoral neck and lumbar spine. Also questionaries was required to pre-made survey about their lifestyles. Analysis of data was done with SPSS program. Multiple regression analysis was used for the relation of bone mineral density, the heigths and BMI. The sample of Groups are checked for drinking, smoking or excercising about differences by t-test. The results of the experiments were; first, there is statistically significant differences in the comparisons between BMD and BMD. But there isn't any special correlation between drinking, smoking and BMD. Secondly, bone mineral density becomes low related to an intake of caffeine. Particularly, this is statically significant on women. Also there is statically significant correlation between femoral neck and quantity of motion for both men and women. Third, there is significant relation between eating habits and bone mineral density on women's lumbar spine. However, there is no significant relation between men's lumbar spine and women's one. Therefore, to prevent osteopenia, it's good to abstain from intaking caffeine within an hour after a meal. In addition, it's helpful to walk or run regularly and have a balanced meal.