• Title/Summary/Keyword: standard regulations

Search Result 708, Processing Time 0.227 seconds

Assessment of Skin Irritation Caused by S-(-)-10,11-Dihydroxyfarnesoic Acid Methyl Ester, a Metabolite of Beauveria bassiana CS1029

  • Kim, Min-A;Lee, Sang-Han
    • Current Research on Agriculture and Life Sciences
    • /
    • v.32 no.3
    • /
    • pp.145-148
    • /
    • 2014
  • To determine whether S-(-)-10,11-dihydroxyfarnesic acid methyl ester (DHFAME) produced by Beauveria bassiana CS1029 potentially causes acute skin irritation as a cosmetic ingredient, a skin toxicity test was conducted as recommended for compliance with Korea Food and Drug Administration regulations. New Zealand White rabbits were treated with 100 mg/dose of DHFAME according to standard guidelines. No significant skin lesions or inflammation was observed in the DHFAME-treated group. Furthermore, DHFAME did not appear to cause skin irritation, as assessed by clinical observation of the rabbits. Thus, when taken together, the present results suggest that DHFAME is a promising potential cosmetic ingredient that does not irritate the skin.

A Response Characteristic Analysis of Impact Acceleration Using Crash Dynamics Models (충돌동역학 모델링 기법에 따른 충돌가속도 응답특성 분석)

  • Cho, Hyun-Jik;Kim, Woon-Gon;Koo, Jeong-Seo
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1602-1606
    • /
    • 2008
  • In the Rail Safety Regulations article 16, deceleration rate in the survival spaces should be limited as far as is practicable to 5g, and shall not be more than 7.5g. As it is impractical to evaluate complete train behaviour by testing, the achievement of the objectives shall be validated by dynamic simulations corresponding to the reference collisions scenarios. But initial design and evaluation procedure, impact dynamics model which classified 1D and 2D is more useful than full scale model. This paper presents acceleration response characteristics between 1D and 2D dynamics model under head-on collision in standard collision scenarios.

  • PDF

Study on Safety Control of The Laser Equipment (레이저 기기의 국제표준 평가 방법 및 안전 관리 방안 연구)

  • Park, Chan-keun;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.419-422
    • /
    • 2016
  • Recently, there are a lot of report about the safety accident in laser equipment for example laser pointer, laser level, laser distance meter, temperature measurement equipment and so on. But most of people doesn't care of the safety, and some of the people were damaged by laser in the retina and skin. So in this reaserch So in this thesis, research the safety control rules in global and domestic regulations and international standard IEC 60825-1. From the above research, develop the safety control rules to improve the consumer safety.

  • PDF

A Study on the Field Application of particulate matter Measurement Instruments in Light Scattering Method (광산란법 미세먼지 계측기의 현장 적용성 평가에 관한 연구 )

  • Liu, Bao-lin;Lee, Chung-Won;Lim, Hyo-Jin;Tae, Sung-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.201-202
    • /
    • 2023
  • Now, there are many cases where materials are maintained at construction sites or standard construction prices are not in accordance with the applicable regulations, resulting in a lot of fine dust. Therefore, a particulate matter measurement system is applied not only to manage particulate matter at construction sites but also to reduce particulate matter .This study aims to evaluate the applicability of this particulate matter measurement system to the construction site through long-term measurement experiments using a light scattering method particulate matter measurement instrument at the construction site.

  • PDF

Effects of Civil Blasting on Noise, Vibration and Total Suspended Particles (토목 발파가 소음, 진동, 부유 분진에 미치는 영향)

  • Jeong, Jin Do;Jeong, Yeong Guk
    • Journal of Environmental Science International
    • /
    • v.13 no.1
    • /
    • pp.99-107
    • /
    • 2004
  • This research is to determine the level of environmental pollution at a blasting construction area which is the origin of noise, vibration, and suspended particle, and to compare the results with other domestic and international standard data. This experiment is also to find out the effects resulting from blasting construction and to propose a plan that can decrease environmental pollution. The blasting construction area is a factory site which is about one and half million square meter and sewage disposal plant is about ninety thousand square meter. Both were selected as the areas for the tests to be conducted in determination test. The test to determine the level of noise, vibration, and total suspended particle was conducted thirty times around the blasting construction area by comparing measurement results and numerical analysis. However, as the test was not conducted in the laboratory but in the actual blasting construction area, it was not possible to do the test with the same exact conditions each true. Therefore, the test was not ideal as conditions could change from test to test. For the most part, the level of noise was below the standard level of 70dB. Every vibration test was under the standard limitation. For example, a house, 200m away was tested for noise and vibration and the level was found to be under the 0.2 cm/sec which is the standard for specialty designed cultural sites., i.e very low level. Also a buried oil pipeline that was 30m away also marked under 2.0cm/sec which is the norm for an industrial area. However, if there were an oil pipeline under the house, the amount of charging gunpowder per hole should be decreased compared to the amount used in the test. The test result for suspended particles under the standard limitation which is 24hour average 300$\mu\textrm{g}$/㎥ at a distance from blasting wavelength, but at detonator, total suspended particle from the blast origin exceeded the standard limitation. If explosion occurs when it detonates in the hole, most of the energy would be absorbed in the crushing of rocks, but some remaining energy would make noises and vibration inevitable. So the important thing is how to minimize the environmental pollution from the blasting. There should be regulations in order that the standard limitation is not exceeded, and to decrease the environmental pollution from the blasting.

A Theoretical Model for the Choice of Alternative Work Arrangements (비정형근로 유형의 선택에 대한 이론적 모형)

  • Rhee, Chong-Hoon
    • Journal of Labour Economics
    • /
    • v.29 no.1
    • /
    • pp.75-98
    • /
    • 2006
  • This study shows a theoretical model, based on transaction cost theory, for the choice of alternative work arrangement, Suppose that standard labor contract (permanent and full-time) is a typical labor contract of within-organization transaction and alternative labor contracts of variety are in the spectrum between market and within-organization transaction, the type and size of the market transaction cost for a specific labor would determine the appropriate labor contract. Firm-specificity and level of skill, scope and uncertainty of tasks, and duration of contract are the major determinants of transaction cost which, in turn, determines the type of labor contract. This theoretical model implies that there will be occupational segregation between standard and alternative work arrangements and that the legal regulations for protecting employment and wage of non-standard workers might not be so effective as expected.

  • PDF

Field Test on IEC60364-4-44 for the Application in Korean distribution system (IEC60364-4-44의 국내 배전계통 적용을 위한 실증시험)

  • Nam, Kee-Young;Choi, Sang-Bong;Jeong, Seong-Whan;Lee, Jae-Duck;Ryoo, Hee-Suk;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.486-487
    • /
    • 2006
  • The authors have studied on the application of IEC 60364-4-44 to Korean electrical installations of buildings from 2004 sponsored by Korean ministry of commerce, industry and energy and the test field is established in K.E.R.I. (Korea Electrotechnology Research Institute). This paper presents the summary results of establishment of test field and analysis for the application of IEC 60364 in Korea. IEC 60364-4-44 provides rules for the protection against the effects of conducted and radiated disturbances on electrical installations. Especially this standard deals with the protection of low voltage facility against the ground fault in the high voltage side of power distribution system. Many countries define the regulations on the use and production of electrical facilities based on their own power system and technical references which are considered to be suitable for them. The background of circuit of IEC 60364-4-44 is based on the ungrounded system as most of European countries. However, since Korean electric power distribution system is based on multi-grounding system different from European system, it is necessary to evaluate or prove the effect of the IEC 60364-4-44 for introducing and applying it to the domestic grounding system as a Korean standard. This paper presents the establishment of test field to get background data to introduce the IEC 60364-4-44 and to evaluate the standard is applicable to domestic rule for the protection against ground fault through the related test

  • PDF

Estimating blood pressure using the pulse transit time of the two measuring from pressure pulse and PPG

  • Kim, Gi-Ryon;Ye, Soo-Young;Kim, Jae-Hyung;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.87-94
    • /
    • 2008
  • Blood pressure (BP), one of the most important vital signs, is used to identify an emergency state and reflects the blood flow characteristics of the cardiovascular system. The conventional noninvasive method of measuring BP is inconvenient because patients must wear a cuff on their arm and the measurement process takes time. This paper proposes an algorithm for estimating the BP using the pulse transit time (PTT) of the photoplethysmography (PPG) and pressure pulse from finger at the same time as a more convenient way to measure the BP. After recording the electrocardiogram (ECG), measuring the pressure pulse, and performing PPG, we calculated the PTT from the acquired signals. Then, we used a multiple regression analysis to measure the systolic and diastolic BP indirectly. Comparing the BP measured indirectly using the proposed algorithm and the real BP measured with a sphygmomanometer, the systolic pressure had a mean error of ${\pm}3.240$ mmHg and a standard deviation of 2.530 mmHg, while the diastolic pressure had a satisfactory result, i.e., a mean error of ${\pm}1.807$ mmHg and a standard deviation of 1.396 mmHg. These results are more superior than existing method estimating blood pressure using the one PTT and satisfy the ANSI/AAMI regulations for certifying a sphygmomanometer i.e., the measurement error should be within a mean error of ${\pm}5$ mmHg and a standard deviation of 8 mmHg. These results suggest the possibility of applying our method to a portable, long-term BP monitoring system.

A study on the regulation of durability standard of underground structures monitoring sensors (지하구조물 계측센서의 내구연한 기준에 대한 규정 분석 연구)

  • Woo, Jong-Tae
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.1
    • /
    • pp.73-81
    • /
    • 2018
  • The purpose of this study is to research the regulation of durability standard of underground structures monitoring sensors. The durability criteria for construction monitoring sensors of domestic construction companies, the standard years of contents such as buildings on the income tax implementation regulations, and the standards of the Public Procurement Service for construction monitoring and construction machinery were analyzed. The durability criterion on products such as the inclination meter and the strain gauge, which are purchased from the Public Procurement Service prior to installation on the underground structure, is 8 to 10 years. It is considered that the monitoring sensor installed in the paperboard and the concrete structure at the time of construction will have considerably shortened service life rather than the useful life of the product itself due to various adverse factors such as groundwater influence and compaction.

A Study on the Utilization Planning of Unused Classrooms of Primary Schools by the Change of Curriculums (교육과정 변천에 따른 초등학교 유휴교실 활용방안에 대한 연구 - 충청북도 초등학교를 대상으로 -)

  • Kim, Seunggeun;Jung, Jinju;Choi, Hyoseung
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.2 no.1
    • /
    • pp.13-24
    • /
    • 2000
  • This study aims at revealing important utilization planning by surveying and analyzing unused classrooms in primary school's facilities. That is various and positive utilization planning of unused classrooms in order to cope with the changes of educational environment focused on high and multi-functionization, rather qualitative aspect than quantitative. By field-survey and interview, physical and environmental factors such as, the change procedure of students, unused facilities in schools and improvement affairs and purpose stressed by schools were surveyed. Additionally, the way of educational facilities to future society linked with residents was examined by surveying about the relationship between educational facilities and regional communities. The curriculums and "School facilities standard ordinance" have been revised in part by several times individually and couldn't meet with educational facilities, educational and social change positively. In rural area, to apply the standard of the capacity by a class with 40 students like city is not desirable. To make educational environment better qualitatively, the capacity should be reduced by 30 students and the unit square per a student enlarged by $2.4m^2$. By room unit module "school institution and managerial regulations under high school" should be applied distinctively to break down like 6, 7~12, 13~24 and over 25 classes. So re-institution of the capacity by a class and the standard unit of the number of class by scale is needed.

  • PDF