Browse > Article
http://dx.doi.org/10.5369/JSST.2008.17.2.087

Estimating blood pressure using the pulse transit time of the two measuring from pressure pulse and PPG  

Kim, Gi-Ryon (PhysioLab Co. Ltd)
Ye, Soo-Young (BK21 Medical Science Education Center, College of Medicine, Pusan National University)
Kim, Jae-Hyung (School of Computer Aided Science, Inje University)
Jeon, Gye-Rok (Department of Biomedical Engineering, College of Medicine, Pusan National University)
Publication Information
Abstract
Blood pressure (BP), one of the most important vital signs, is used to identify an emergency state and reflects the blood flow characteristics of the cardiovascular system. The conventional noninvasive method of measuring BP is inconvenient because patients must wear a cuff on their arm and the measurement process takes time. This paper proposes an algorithm for estimating the BP using the pulse transit time (PTT) of the photoplethysmography (PPG) and pressure pulse from finger at the same time as a more convenient way to measure the BP. After recording the electrocardiogram (ECG), measuring the pressure pulse, and performing PPG, we calculated the PTT from the acquired signals. Then, we used a multiple regression analysis to measure the systolic and diastolic BP indirectly. Comparing the BP measured indirectly using the proposed algorithm and the real BP measured with a sphygmomanometer, the systolic pressure had a mean error of ${\pm}3.240$ mmHg and a standard deviation of 2.530 mmHg, while the diastolic pressure had a satisfactory result, i.e., a mean error of ${\pm}1.807$ mmHg and a standard deviation of 1.396 mmHg. These results are more superior than existing method estimating blood pressure using the one PTT and satisfy the ANSI/AAMI regulations for certifying a sphygmomanometer i.e., the measurement error should be within a mean error of ${\pm}5$ mmHg and a standard deviation of 8 mmHg. These results suggest the possibility of applying our method to a portable, long-term BP monitoring system.
Keywords
pulse transit time; blood pressure;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 X. F. Teng and Y. T. Zhang, 'Continuous and noninvasive estimation of arterial blood pressure using a plethysmographic approach', Proc. of the 25th Annual International Conf. of the IEEE EMBS, pp. 3153-3156, 2003
2 D. K. Jung, G. R. Kim, K. N. Kim, B. C. Choi, D. J. Suh, G. R. Jeon, and S. Y. Ye, 'Change of pulse wave velocity in arm according to characteristic points of pulse wave', Proc. of the 2007 international conf. on convergence information technology, pp. 821-826, 2007
3 G. V. Marie, C. R. Lo, and D. W. Johnston, 'The relationship between pulse transit time and blood pressure', Psychophysiology, vol. 21, no. 5, pp. 521-527, 1984   DOI   ScienceOn
4 D. U. Jeong, J. W. Bae, J. M. Shon, S. Y. Yea, B. C. Choi, K. G. Nam, C. H. Kim, and G. R. Jeon, 'Implementation of impedance method to estimate blood flow variation with cuff presssure change', J. Kor. Sensors Soc., vol. 13, no. 6, pp. 462-472, 2004   과학기술학회마을   DOI
5 E. K. Park, S. M. Lee, Y. H. Han, J. Y. Lee, S. Y. Kwon, I. Y. Kim, and S. I. Kim, 'A study on estimation of systolic blood pressure using PTT', J. Biomed. Eng. Res., vol. 25, no. 6, pp. 605-609, 2004   과학기술학회마을
6 J. Lass, K. Meigas, D. Karai, R. Kattai, J. Kaik, and M. Rossmann, 'Continuous blood pressure monitoring during exercise using pulse wave transit time measurement,' Proc. of the 26th Annual International Conf. of the IEEE EMBS, pp. 2239-2242 , 2004
7 L. A. Geddes, M. Voelz, C. Combs, D. Reiner, and C. F. Babbs., 'Characterization of the oscillometric method for measuring indirect blood pressure', Ann. Biomed. Eng., vol. 10, pp. 271-280, 1982   DOI
8 K. G. Ng and C. F.Small, 'Survey of automated noninvasive blood pressure monitors', J. Clin. Eng., vol. 19, pp. 452-487, 1994   DOI
9 R. P. Kelly, C. S.Hayward, A. P. Avolio, and M. F. O'Rourke, 'Noninvasive determination of agerelated changes in the human arterial pulse', Circulation, vol. 80, pp. 1652-1659, 1989   DOI   ScienceOn
10 D. Franchi, R. Bedini, F. Manfredini, S. Berti, G. Palagi, S. Ghione, and A. Ripoli, 'Blood pressure evaluation based on arterial pulse wave velocity', Proc. of IEEE Computers in Cardiology, pp. 397- 400, 1996
11 G. R. Kim, G. N. Kim, B. C. Choi, G. R. Jeon, K. Y. Ham, D. J. Suh, and D. K. Jung, 'Implementation and evaluation of the sensor assessing pressure and photoplethysmogram', J. Kor. Sensors Soc., vol. 15, no. 2, pp. 32-37, 2006   과학기술학회마을   DOI
12 S. Hales, Statistical Essay: Containing Hemastaticks, pp. 1-9, 1773