A Study on the Operation Condition by Electrical Fault in the High Temperature Fuel Cell Plant (고온 연료전지 발전단지의 내부계통 고장에 의한 운전환경에 대한 분석)

  • Chong, Young-Whan;Chai, Hui-Seok;Kim, Jae-Chul;Cho, Sung-Min
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.8
    • /
    • pp.51-59
    • /
    • 2013
  • High temperature fuel cell system, such as molten carbonate fuel cells(MCFC) and solid oxide fuel cells(SOFC), are capable of operating at MW rated power output. The power output change of high temperature fuel cell imposes the thermal and mechanical stresses on the fuel cell stack. To minimize the thermal-mechanical stresses on the stack, increases in the power output of high temperature fuel cell typically must be made at a slow rate. So, the short time interruption of high temperature fuel cell causes considerable generated energy losses. Because of the characteristic of high temperature fuel cell, we analyzed the impact of electrical fault in the fuel cell plant on other fuel cell generators in the same plant site. A various grounding configuration and voltage sag are analyzed. Finally, we presented the solution to minimize the effect of fault on other fuel cell generators.

Analyzing the Effects of MEA Designs on Cold Start Behaviors of Automotive Polymer Electrolyte Fuel Cell Stacks (자동차용 고분자전해질형연료전지 스택에서의 막-전극접합체 설계인자가 저온시동에 미치는 영향성 연구)

  • Gwak, Geon-Hui;Ko, Jo-Han;Ju, Hyun-Chul
    • Journal of Hydrogen and New Energy
    • /
    • v.23 no.1
    • /
    • pp.8-18
    • /
    • 2012
  • This paper presents a three-dimensional, transient cold-start polymer electrolyte fuel cell (PEFC) model to numerically evaluate the effects of membrane electrode assembly (MEA) design and cell location in a PEFC stack on PEFC cold start behaviors. The cold-start simulations show that the end cell experiences significant heat loss to the sub-freezing ambient and thus finally cold-start failure due to considerable ice filling in the cathode catalyst layer. On the other hand, the middle cells in the stack successfully start from $-30^{\circ}C$ sub-freezing temperature due to rapid cell temperature rise owing to the efficient use of waste heat generated during the cold-start. In addition, the simulation results clearly indicate that the cathode catalyst layer (CL) composition and thickness have an substantial influence on PEFC cold-start behaviors while membrane thickness has limited effect mainly due to inefficient water absorption and transport capability at subzero temperatures.

Device and Circuit Performance Issues with Deeply Scaled High-K MOS Transistors

  • Rao, V. Ramgopal;Mohapatra, Nihar R.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.4 no.1
    • /
    • pp.52-62
    • /
    • 2004
  • In this paper we look at the effect of Fringe-Enhanced-Barrier-lowering (FEBL) for high-K dielectric MOSFETs and the dependence of FEBL on various technological parameters (spacer dielectrics, overlap length, dielectric stack, S/D junction depth and dielectric thickness). We show that FEBL needs to be contained in order to maintain the performance advantage with scaled high-K dielectric MOSFETs. The degradation in high-K dielectric MOSFETs is also identified as due to the additional coupling between the drain-to-source that occurs through the gate insulator, when the gate dielectric constant is significantly higher than the silicon dielectric constant. The technology parameters required to minimize the coupling through the high-K dielectric are identified. It is also shown that gate dielectric stack with a low-K material as bottom layer (very thin $SiO_2$ or oxy-nitride) will be helpful in minimizing FEBL. The circuit performance issues with high-K MOS transistors are also analyzed in this paper. An optimum range of values for the dielectric constant has been identified from the delay and the energy dissipation point of view. The dependence of the optimum K for different technology generations has been discussed. Circuit models for the parasitic capacitances in high-K transistors, by incorporating the fringing effects, have been presented.

Psychological Characteristic Analysis of Brick Pavement Patterns in Rural Area (농촌공간에 적용된 벽돌포장 줄눈의 심리적 특성 분석)

  • Kim, Dae-Hyun;Shin, Ji-Hoon
    • Journal of Korean Society of Rural Planning
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2008
  • Recently, brick pavement were widely introduced on the pavement in rural area. A variety of vision effects can be created from patterns of brick pavement. However, in most of brick pavement works, human psychological characteristics were not concerned. The purpose of this research was to discover psychological effect on brick pavement pattern. The results of the research can be summarized as follows: 1)Psychological impression on brick pavement pattern is similar among man and woman groups. 2)Stack bond and running bond pattern have a simple, relaxed, organized, and comfortable psychological characteristics. Basket weave & stack bond pattern has a simple and organized psychological characteristic. Herringbone bond pattern has a complex, dislike and uncomfortable psychological characteristic. Pinwheel bond pattern has a highly complex psychological characteristic. Basket weave and Basket weave variation bond pattern have a common psychological characteristic. 3)Employment of brick pavement pattern on this research is not highly preferred, hence it is necessary to develop a brick pavement patterns that have human psychological characteristics be concerned.

Ventilation Performance According to Outdoor and Operating Conditions of the Vertical Exhaust Duct System in High Riser Public Houses (초고층 공동주택의 입상덕트 환기시스템에서 외기조건과 작동조건에 따른 환기성능평가)

  • Kim, Young-Bae;Kim, Jae-Hong;Sung, Jae-Yong;Lee, Myeong-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.2
    • /
    • pp.139-146
    • /
    • 2011
  • The ventilation performance of a vertical exhaust duct system in the high riser public house has been evaluated by a commercial software, Fluid Flow, which solves pressure losses through the duct system including bathroom fans and a hybrid roof fan. During the numerical simulations, outdoor wind condition and stack effects in summer and winter were considered as well as the operating conditions of a basement damper and the roof fan. The results show that the bathroom ventilation in summer is the most unsatisfactory. The opening of the basement damper has a problem that the polluted air in the lower floors is exhausted to the underground parking lot, not to the rooftop. If the basement damper is closed, the exhaust flow rate in the lower floors is not sufficient due to the strong flow resistance in the long vertical duct even though the roof fan is under operating.

Application of Solar Chimney System for Natural Ventilation in Underground Space (지하공간의 자연환기를 위한 태양 굴뚝 시스템의 응용)

  • Jang, Hyang-In;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.2
    • /
    • pp.87-95
    • /
    • 2010
  • This study analyzed the performance of solar chimney system for natural ventilation in underground space. A mathematical model of the solar chimney was proposed in order to predict its performance under varying parameters and Korea climatic condition. Steady state heat transfer equations were set up using a energy balanced equations and solved using a inverse matrix method. Numerical simulation program to analyze system was developed by using MATLAB. As the results, the ventilation performance of the solar chimney was determined by the temperature difference of air channel and inlet, and the temperature difference was influenced by insolation, stack height and distance of air gab. Also the solar chimney system can provide $262.9m^3/h$ of annual average ventilation rate. Because seasonal differences of ventilation rate was calculated within 25%, the solar chimney system can be used for every season in Korea climatic condition. Through this study, performance of solar chimney system for natural ventilation was verified by numerical method. Consequently, the solar chimney system is proved to be effective device for natural ventilation utilizing at all times, and the additional studies should be made through the experimental method for imagineering and commercialization.

Microcavity-enhanced White OLED for efficient lighting application

  • Chin, Byung-Doo;Kim, Jae-Kyeong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1591-1594
    • /
    • 2006
  • In this work, we fabricated efficient white organic light emitting device (WOLED) by the stack of complementary fluorescent dye-doped layers, Effect of dye-doping ratio and thickness of each layers on WOLED efficiency and emission spectrum was investigated. Moreover, out-coupling efficiency enhancement using microlens array was analyzed for bottom and top-emitting device architecture, leading to higher light extraction properties.

  • PDF

An Optimal Register resource Allocation Algorithm using Graph Coloring

  • Park, Ji-young;Lim, Chi-ho;Kim, Hi-seok
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.302-305
    • /
    • 2000
  • This paper proposed an optimal register resource allocation algorithm using graph coloring for minimal register at high level synthesis. The proposed algorithm constructed interference graph consist of the intermediated representation CFG to description VHDL. and at interference graph fur the minimal select color selected a position node at stack, the next inserted spill code and the graph coloring process executes for optimal register allocation. The proposed algorithm proves to effect that result compare another allocation techniques through experiments of bench mark.

  • PDF

Construction Process & Technologies Applied to Parc.1 Project

  • Hoi-soo, Seo;Jae-min, Baek
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.3
    • /
    • pp.181-187
    • /
    • 2022
  • POSCO E&C has completed Parc.1 project successfully. The construction period was 42months, and 1.5 million workers were participated till completion. To meet schedule management and quality control, POSCO E&C has adopted a lot of technologies such as GPS measurement, 3D scanning, vibration control, stack effect control, column shortening control, etc