• Title/Summary/Keyword: stability of treatment

Search Result 2,388, Processing Time 0.033 seconds

Optimization of Culture Conditions and Encapsulation of Lactobacillus fermentum YL-3 for Probiotics (가금류 생균제 개발을 위한 Lactobacillus fermentum YL-3의 배양조건 최적화 및 캡슐화)

  • Kim, Kyong;Jang, Keum-Il;Kim, Chung-Ho;Kim, Kwang-Yup
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.255-262
    • /
    • 2002
  • This experiment was performed to improve the stability of Lactobacillus fermentum YL-3 as a poultry probiotics. The culture conditions that improve acid tolerance of L. fermentum YL-3 were investigated by changing several factors such as medium composition, temperature, anaerobic incubation and culture time. Also, L. fermentum YL-3 was encapsulated with alginate, calcium chloride and chitosan. The stable culture conditions of L. fermentum YL-3 were obtained in anaerobic incubation using MRS media without tween 80 for 20 hour at $42^{\circ}C$. The capsule after treatment with 1% chitosan was formed close membrane by a bridge bond. Immobilization of L. fermentum YL-3 in capsule was observed by confocal laser scanning microscopy, and cell viability was $2.0{\times}10^9\;CFU/g$ above the average. L. fermentum YL-3 capsule after acid treated at pH 2.0 for 3 hour survived about 40%, but those encapsulated with 1% chitosan survived about 65%. Survival rate of capsule stored at room temperature decreased about $2{\sim}3$ log cycle during 3 weeks, but viability of capsule stored at $4^{\circ}C$ during 3 weeks maintained almost $10^8\;CFU/g$ levels.

Properties of Dietary Fiber Extract from Rice Bran and Application in Bread-making (미강에서 추출한 식이섬유추출물의 특성 및 제빵에의 응용)

  • Kim, Young-Soo;Ha, Tae-Youl;Lee, Sang-Hyo;Lee, Hyun-Yu
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.502-508
    • /
    • 1997
  • Rice bran dietary fiber extract, which was obtained after termamyl treatment of defatted rice bran contained $27.3{\sim}30.5%$ protein, $49.7{\sim}54.1%$ insoluble dietary fiber, and $1.9{\sim}2.7%$ soluble dietary fiber. Extrusion decreased the insoluble dietary fiber content but increased the soluble dietary fiber content, while roasting did not. Influence those content. Each mineral element content was depended upon heat processing method. Extrusion increased the water binding capacity and L value, while roasting reduced the water binding capacity and L value. Scanning electron microscopy showed damaged cell walls for extruded sample compared to roasted one which had fully collapsed cell walls. The increase of water absorption, developing time, and stability and the of MTI of wheat flour-dietary fiber extract composites with addition of dietary fiber extract were observed by Farinograph. Rice bran dietary fiber extract had an effect on the bread making resulting in increase of bread weight and color of crumb and crust, and decrease of bread volume and texture. As a result of sensory evaluation, appearance, texture, overall acceptability were significantly different from control but flavor and taste were not different significantly up to 6% level. Heat treated samples had differences in mean values, but not significant differences statistically.

  • PDF

Posterior Cruciate Ligament Reconstruction by Tibial Inlay Technique (Tibial Inlay 방법을 이용한 후방 십자 인대 재건술의 결과)

  • Song Eun Kyoo;Yoon Taek Rim;Jung Jong Wook;Kim Jong Seon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.80-84
    • /
    • 2001
  • Purpose : To evaluate the clinical and radiological results of posterior cruciate ligament reconstruction(PCL) by tibial inlay technique. Materials and Methods : Twenty four patients(25 cases), who underwent reconstruction of posterior cruciate ligament by tibial inlay technique and were followed up for at least 2 years, were reviewed retrospectively. Mean age at operation was 35 years and mean period of follow up was 34 months. Clinically Lysholm knee socre, posterior drawer test and step off sign were evaluated. Instrumented posterior laxity test with $Telos^{\circledR}$ device(Telos stress device; Austin & Associates, Inc., Polston, US) was performed. Results : Lysholm knee score was improved from 56.9 points preoperatively to 94.6 points at fellow up. Posterior drawer test showed grade II instability in 1 case, grade III in 18 and Grade IV in 6 preoperatively and improved to grade I In 12, grade II in 10 and grade III in 3 at follow up. Step off signs were changed from -10mm in 6 cases, -5mm in 18 and flush in 1 preoperatively to -5mm in 3, flush in 10 and +5mm in 12 at follow up. Side to side difference of instrumented posterior laxity test was improved front 13.6mm preoperatively to 4.3mm at follow up. Conclusions : PCL reconstruction by tibial inlay technique is considered to be a good treatment method to restore posterior stability of the knee, which could result in satisfactory clinical and radiological results at more than 2 years' follow up.

  • PDF

Middle and Long Term Results of 34 Cases of Emergency Coronary Artery Bypass Graft Surgery (응급 관상동맥 우회술 34예의 중장기 성적)

  • 손정환;김응중;지현근;신윤철;김건일;최광민;이원진;이원용
    • Journal of Chest Surgery
    • /
    • v.36 no.10
    • /
    • pp.741-747
    • /
    • 2003
  • Background: Coronary artery bypass graf t (CABG) has been settled as most safe surgery among the open heart surgeries. However, in patients with cardiogenic shock, the emergency CABG has higher mortality than elective CABG. We analyzed thirty four patients who underwent emergency CABG and report the middle and long-term results. Material and Method: From June 1994 to December 2001, 34 patients who underwent emergency CABG at Kang-dong Sacred Heart Hospital were include in this study. On the basis of hospital databases and Out Patient Department (OPD) follow up data, preoperative diagnosis, risk factor, coronary artery anatomy, operation technique, postoperative mortality, complication, recurrence of symptom, and mid and long term mortality were analyzed retrospectively. Result: Indications for emergency CABG were 29 cardiogenic shocks (85.3%), 4 intractable chest pains (11.8%), and 1 polymorphic ventricular tachycardia (2.9%). Preoperative angiographic diagnoses were triple vessel disease in 16 (47.1%) and left main disease in 8 (23.5%) patients. We used saphenous vein grafts in 81 and left internal thoracic artery grafts in 14 anastomosis. The mean number of grafts per patients was 2.8$\pm$0.8. The mean aortic cross clamp time was 91.9$\pm$34.6 minutes and the mean cardiopulmonary bypass time was 262.7$\pm$198.3 minutes. Early mortality was 50% and the most common cause of early mortality was low cardiac output in 7 (20.6%) patients. The mean follow-up period was 30.9$\pm$35.7 months. There were no recurrences of symptom and late mortality. Conclusion: In the case of emergency operation, aggressive and proper management with drugs and IABP should be done for preoperative hemodynamic stability and early surgical intervention is the most important factor for patient salvage.

Production of yuzu granules using enzyme treated yuzu pulp powder and evaluation of its physiochemical and functional characterization (유자박 식이섬유를 이용한 유자과립 제조 및 이화학적 특성조사)

  • Seong, Hyeon Jun;Lee, Bo-Bae;Kim, Duck-Hyun;Lee, Seung-Hyun;Ha, Ji-Young;Nam, Seung-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.53 no.4
    • /
    • pp.382-390
    • /
    • 2021
  • In this study, solubilized yuzu pulp powder (EYP) was produced using enzyme treated yuzu pulp powder (YP) and used to manufacture yuzu granules (0-20% EYP content). The physicochemical, product stability, and functional properties of Yuzu granules were compared among five enzyme treatments. Among the five treatments, CL had the highest YP solubilization yield (48.68%). Microstructural observation of EYP using FE-SEM revealed that its surface became irregular and porous after enzymatic treatment. Compared to YP, EYP had 2 times lower insoluble dietary fibers and 3 times lower hemicellulose and cellulose content. Among the yuzu granules, IV (yuzu granules with 15% EYP) had an excellent water and oil holding capacity and flowability. IV granule had the highest narirutin and hesperidin content of 3.4 mg and 2.2 mg/g DW, respectively and the highest antioxidant (68.4%) and tyrosinase inhibitory activities (82.5%). Therefore, EYP or granule with EYP can be used as a functional component in food industry or pharmaceutical field.

Stabilization of Radioactive Molten Salt Waste by Using Silica-Based Inorganic Material (실리카 함유 무기매질에 의한 폐용융염의 안정화)

  • Park, Hwan-Seo;Kim, In-Tae;Kim, Hwan-Young;Kim, Joon-Hyung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.3
    • /
    • pp.171-177
    • /
    • 2007
  • This study suggested a new method to stabilize molten salt wastes generated from the pyre-process for the spent fuel treatment. Using conventional sol-gel process, $SiO_2-Al_2O_3-P_2O_5$ (SAP) inorganic material that is reactive to metal chlorides were prepared. In this paper, the reactivity of SAP with the metal chlorides at $650{\sim}850$, the thermal stability of reaction products and their leach-resistance under the PCT-A test method were investigated. Alkali metal chlorides were converted into metal aluminosilicate($LixAlxSi1-_xO_{2-x}$) and metal phosphate($Li_3PO_4\;and\;Cs_2AlP_3O_{10}$) While alkali earth and rare earth chlorides were changed into only metal phosphates ($Sr_5(PO_4)_3Cl\;and\;CePO_4$). The conversion rate was about $96{\sim}99%$ at a salt waste/SAP weight ratio of 0.5 and a weight loss up to $1100^{\circ}C$ measured by thermogravimetric analysis were below 1wt%. The leach rates of Cs and Sr under the PCT-A test condition were about $10^{-2}g/m^2\;day\;and\;10^{-4}g/m^2\;day$. From these results, it could be concluded that SAP can be considered as an effective stabilizer for metal chlorides and the method using SAP will give a chance to reduce the volume of salt wasteform for the final disposal through further researches.

  • PDF

The Alignment Evaluation for Patient Positioning System(PPS) of Gamma Knife PerfexionTM (감마나이프 퍼펙션의 자동환자이송장치에 대한 정렬됨 평가)

  • Jin, Seong Jin;Kim, Gyeong Rip;Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.203-209
    • /
    • 2020
  • The purpose of this study is to assess the mechanical stability and alignment of the patient positioning system (PPS) of Leksell Gamma Knife Perfexion(LGK PFX). The alignment of the PPS of the LGK PFX was evaluated through measurements of the deviation of the coincidence of the Radiological Focus Point(RFP) and the PPS Calibration Center Point(CCP) applying different weights on the couch(0, 50, 60, 70, 80, and 90 kg). In measurements, a service diode test tool with three diode detectors being used biannually at the time of the routine preventive maintenance was used. The test conducted with varying weights on the PPS using the service diode test tool measured the radial deviations for all three collimators 4, 8, and 16 mm and also for three different positions of the PPS. In order to evaluate the alignment of the PPS, the radial deviations of the correspondence of the radiation focus and the LGK calibration center point of multiple beams were averaged using the calibrated service diode test tool at three university hospitals in Busan and Gyeongnam. Looking at the center diode for all collimators 4, 8, and 16 mm without weight on the PPS, and examining the short and long diodes for the 4 mm collimator, the means of the validation difference, i.e., the radial deviation for the setting of 4, 8, and 16 mm collimators for the center diode were respectively measured to 0.058 ± 0.023, 0.079 ± 0.023, and 0.097 ± 0.049 mm, and when the 4 mm collimator was applied to the center diode, the short diode, and the long diode, the average of the radial deviation was respectively 0.058 ± 0.023, 0.078 ± 0.01 and 0.070 ± 0.023 mm. The average of the radial deviations when irradiating 8 and 16 mm collimators on short and long diodes without weight are measured to 0.07 ± 0.003(8 mm sd), 0.153 ± 0.002 mm(16 mm sd) and 0.031 ± 0.014(8 mm ld), 0.175 ± 0.01 mm(16 mm ld) respectively. When various weights of 50 to 90 kg are placed on the PPS, the average of radial deviation when irradiated to the center diode for 4, 8, and 16 mm is 0.061 ± 0.041 to 0.075 ± 0.015, 0.023 ± 0.004 to 0.034 ± 0.003, and 0.158 ± 0.08 to 0.17 ± 0.043 mm, respectively. In addition, in the same situation, when the short diode for 4, 8, and 16 mm was irradiated, the averages of radial deviations were 0.063 ± 0.024 to 0.07 ± 0.017, 0.037 ± 0.006 to 0.059 ± 0.001, and 0.154 ± 0.03 to 0.165 ± 0.07 mm, respectively. In addition, when irradiated on long diode for 4, 8, and 16 mm, the averages of radial deviations were measured to be 0.102 ± 0.029 to 0.124 ± 0.036, 0.035 ± 0.004 to 0.054 ± 0.02, and 0.183 ± 0.092 to 0.202 ± 0.012 mm, respectively. It was confirmed that all the verification results performed were in accordance with the manufacturer's allowable deviation criteria. It was found that weight dependence was negligible as a result of measuring the alignment according to various weights placed on the PPS that mimics the actual treatment environment. In particular, no further adjustment or recalibration of the PPS was required during the verification. It has been confirmed that the verification test of the PPS according to various weights is suitable for normal Quality Assurance of LGK PFX.

Isolation of Marine Bacteria Killing Red Tide Microalgae -IV. Characteristics of Algicidal Substances, Produced from Micrococcus sp. LG-5 and the Effects on Marine Organisms- (적조생물 살조세균 탐색 -IV. 살조세균 Micrococcus sp. LG-5가 생산하는 살조물질의 특성과 해양생물에 미치는 영향-)

  • JEONG Seong-Youn;PARK Young-Tae;KIM Mu-Chan;CHOI Seok-Cheol;SEONG Hee-Kyung;KIM Jai-Young;KIM Tae-Un;LEE Won-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.33 no.4
    • /
    • pp.339-347
    • /
    • 2000
  • An algicidal bacterium, Micrococcus sp. LG-5 against the harmful dinoflagellate, Cochlodinium polykrikoides was isolated. The optimal conditions for the highest algicidal activity of bacterial culture filtrate showed in the range of $20{\~}30^{\circ}C$, at pH 7.0 and $3.0{\%}$ of NaCl concentration. In addition, $IC_(50)(mean of 50{\%} inhibitory concentration)$ of the culture filtrate against C. polykrikoides after incubation of 5 days was $0.482{\%}$. To investigate heat and pH stability of the culture filtrate of Micrococcus sp. LG-5, the culture filtrate ($pore size, 0.1 {\mu}m$) was heated to $121^{\circ}C for 15 min$ and adjusted pH from 2.0 to 10.0. There were no significant changes in algicidal activity by heat treatment and the pH change between pH from 5.0 to 10.0. The algicidal substances produced from Micrococcus sp. LG-5 were mainly detected in the fraction of $10,000{\~}1,000$ MWCO (molecular weight cut-off). The culture filtrate of Micrococous sp. LG-5 showed antimicrobial activity against Enterococcus faecalis, Escheiichia coli, Uebsiella pneunioniae and Vibrio altinolyticus, but did not show against Pseudomonas aeminosa, P. Buorescens, Salmonella typhi, Staphylococcus aureus, V. cholerae and V parahaemolyicus. The culture filtrate of Micrococcus sp. LG-5 was examined against 16 phytoplankton species and showed the algicidal activity against Ajexandzium tuarense, Eutreptiella Drnnastin, Gymnodinium catenatum, G. mikimotoi, G. sanguineum, eyodinium impuaicum, Heterocapsa triquetra, Heterosipa akashiwo, Prorocentrum micans and Pyraminonas sp.. However no algicidal effects of Micrococcus sp. LG-5 were observed against Chlamydomonas sp., Cylindrotheoa closterium, P. mininum, P. triestimum, Pseudonieschia sp. and Sczipuiella trochoidea. On the other hand, algicidal activity on the tested marinelivefood was not detected except for Isochrysis galbana. In addition, physiological responses of cultured olive flounder (Paralichthys oliraceus) exposed to $1 and 10{\%}$ of the culture filtrate of Micrococcus sp. LG-5 were measured. There were no clear changes in AST, GGT, creatinine, urea, total cholesterol, total protein, albumine, $Mg^(+2), Ca^(+2), Na^+, K^+, and Cl^-$. These results indicate that olive flounders were not affected when they were exposed to the culture filtrate of Micrococcus sp. LG-5.

  • PDF