• 제목/요약/키워드: spectrum imaging

Search Result 300, Processing Time 0.035 seconds

Preliminary Study for Imaging of Therapy Region from Boron Neutron Capture Therapy (붕소 중성자 포획 치료에서 치료 영역 영상화를 위한 예비 연구)

  • Jung, Joo-Young;Yoon, Do-Kun;Han, Seong-Min;Jang, HongSeok;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.151-156
    • /
    • 2014
  • The purpose of this study was to confirm the feasibility of imaging of therapy region from the boron neutron capture therapy (BNCT) using the measurement of the prompt gamma ray depending on the neutron flux. Through the Monte Carlo simulation, we performed the verification of physical phenomena from the BNCT; (1) the effects of neutron according to the existence of boron uptake region (BUR), (2) the internal and external measurement of prompt gamma ray dose, (3) the energy spectrum by the prompt gamma ray. All simulation results were deducted using the Monte Carlo n-particle extended (MCNPX, Ver.2.6.0, Los Alamos National Laboratory, Los Alamos, NM, USA) simulation tool. The virtual water phantom, thermal neutron source, and BURs were simulated using the MCNPX. The energy of the thermal neutron source was defined as below 1 eV with 2,000,000 n/sec flux. The prompt gamma ray was measured with the direction of beam path in the water phantom. The detector material was defined as the lutetium-yttrium oxyorthosilicate (Lu0,6Y1,4Si0,5:Ce; LYSO) scintillator with lead shielding for the collimation. The BUR's height was 5 cm with the 28 frames (bin: 0.18 cm) for the dose calculation. The neutron flux was decreased dramatically at the shallow region of BUR. In addition, the dose of prompt gamma ray was confirmed at the 9 cm depth from water surface, which is the start point of the BUR. In the energy spectrum, the prompt gamma ray peak of the 478 keV was appeared clearly with full width at half maximum (FWHM) of the 41 keV (energy resolution: 8.5%). In conclusion, the therapy region can be monitored by the gamma camera and single photon emission computed tomography (SPECT) using the measurement of the prompt gamma ray during the BNCT.

Development of $^1H-^{31}P$ Animal RF Coil for pH Measurement Using a Clinical MR Scanner (임상용 MR에서 pH 측정을 위한 동물 실험용 $^1H-^{31}P$ RF 코일 개발)

  • Kim, Eun Ju;Kim, Daehong;Lee, Sangwoo;Heo, Dan;Lee, Young Han;Suh, Jin-Suck
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.52-58
    • /
    • 2014
  • Purpose : To establish a pH measurement system for a mouse tumor study using a clinical scanner, to develop the $^1H$ and 31P radio frequency (RF) coil system and to test pH accuracy with phantoms. Materials and Methods: The $^1H$ and the $^{31}P$ surface coils were designed to acquire signals from mouse tumors. Two coils were positioned orthogonally for geometric decoupling. The pH values of various pH phantoms were calculated using the $^1H$ decoupled $^{31}P$ MR spectrum with the Henderson-Hasselbalch equation. The calculated pH value was compared to that of a pH meter. Results: The mutual coil coupling was shown in a standard $S_{12}$. Coil coupling ($S_{12}$) were -73.0 and -62.3 dB respectively. The signal-to-noise ratio (SNR) obtained from the homogeneous phantom $^1H$ image was greater than 300. The high resolution in vivo mice images were acquired using a $^{31}P$-decoupled $^1H$ coil. The pH values calculated from the $^1H$-decoupled $^{31}P$ spectrum correlated well with the values measured by pH meter ($R^2$=0.97). Conclusion: Accurate pH values can be acquired using a $^1H$-decoupled $^{31}P$ RF coil with a clinical scanner. This two-surface coil system could be applied to other nuclear MRS or MRI.

Stenotrophomonas maltophilia and Ventilator-Associated Pneumonia in Critically Ill Pediatric Patients: a Retrospective Analysis at a Single Center (소아 환자에서 Stenotrophomonas maltophilia와 인공 환기요법 관련 폐렴에 관한 연구)

  • Lee, Byung-Kee;Choi, Soo-Han;Kim, Soo Jin;Cho, Joong Bum;Ae, Hong;Yoo, So-young;Kim, Ji Hye;Lee, Nam Young;Kim, Yae-Jean
    • Pediatric Infection and Vaccine
    • /
    • v.22 no.2
    • /
    • pp.75-80
    • /
    • 2015
  • Purpose: Ventilator-associated pneumonia (VAP) is a serious threat in critically ill pediatric patients. Data regarding Stenotrophomonas maltophilia VAP in pediatric population is limited. We evaluated the clinical data of S. maltophilia associated VAP in critically ill pediatric patients. Methods: A retrospective chart review was performed in pediatric patients 18 years old or younger who developed S. maltophilia associated VAP at Samsung Medical Center, Seoul Korea from January 2008 to December 2012. Results: A total of 31 patients were identified S. maltophilia associated VAP. Median age was 8 months (range, 0.5 month to 16.6 years) and 13 patients were male (40.6%). Underlying illnesses were cardiologic diseases (n=11, 34.4%), hematologic oncologic malignancies (n=7, 25%), neurologic diseases (n=4, 12.5%), pulmonary diseases (n=3, 9.4%), and others (n=4, 12.5%). The median duration of ventilator use before S. maltophilia VAP diagnosis was 14 days (range, 4-256 days). Overall mortality at 30 days was 12.5% (4/32). Conclusions: S. maltophilia should be also considered as a possible pathogen for VAP in critically ill pediatric patients. Empiric antibiotic choice should include agents that are active against S. maltophilia in patients who are deteriorating on broad spectrum beta-lactam antimicrobial agents.

Fabrication of [320×256]-FPA Infrared Thermographic Module Based on [InAs/GaSb] Strained-Layer Superlattice ([InAs/GaSb] 응력 초격자에 기초한 [320×256]-FPA 적외선 열영상 모듈 제작)

  • Lee, S.J.;Noh, S.K.;Bae, S.H.;Jung, H.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.1
    • /
    • pp.22-29
    • /
    • 2011
  • An infrared thermographic imaging module of [$320{\times}256$] focal-plane array (FPA) based on [InAs/GaSb] strained-layer superlattice (SLS) was fabricated, and its images were demonstrated. The p-i-n device consisted of an active layer (i) of 300-period [13/7]-ML [InAs/GaSb]-SLS and a pair of p/n-electrodes of (60/115)-period [InAs:(Be/Si)/GaSb]-SLS. FTIR photoresponse spectra taken from a test device revealed that the peak wavelength (${\lambda}_p$) and the cutoff wavelength (${\lambda}_{co}$) were approximately $3.1/2.7{\mu}m$ and $3.8{\mu}m$, respectively, and it was confirmed that the device was operated up to a temperature of 180 K. The $30/24-{\mu}m$ design rule was applied to single pixel pitch/mesa, and a standard photolithography was introduced for [$320{\times}256$]-FPA fabrication. An FPA-ROIC thermographic module was accomplished by using a $18/10-{\mu}m$ In-bump/UBM process and a flip-chip bonding technique, and the thermographic image was demonstrated by utilizing a mid-infrared camera and an image processor.

Growth Evaluation of Lipid Production Microalgae Scenedesmus obliquus using Raman Spectroscopy (라만 분광법을 이용한 지질생산 미세조류 Scenedesmus obliquus 성장 평가)

  • Yoo, Yong Jin;Lee, Geon Woo;Baek, Dong Hyun;Lee, Jin Woo;Kim, Ho Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.223-229
    • /
    • 2020
  • Biodiesel produced using microorganisms, which are recognized as the third-generation biomass, is among the various known renewable energy sources that can replace fossil fuels used in conventional transportation. Scenedesmus obliquus has been identified as an excellent species for biodiesel production, as it grows faster and can accumulate up to 40-50 percent of the dry cell weight. Enhancing production using S. obliquus requires measuring the cell mass for controlling the cultivation process. In the current study, S. obliquus was cultured for 75 days, and growth changes of the microalgae were measured by absorbance, microscopic imaging, and Raman spectroscopy. Between days 60 to 75 of culture, the change in absorbance was observed to be less than 3%, whereas the number of microalgae observed microscopically was more than three times higher. Moreover, the Raman spectroscopy results showed three strong peak values of β-carotene at 997 cm-1, 1148 cm-1, and 1515 cm-1, with peak values of β-carotene showing greater than 3-fold increase during the culture period. Therefore, we predict that application of Raman spectroscopy will help in identifying the growth elements and growth degree in microalgae culture during increased biomass production.

Usefulness of the PRESS Technique using 3.0T Magnetic Resonance Spectroscopy for Evaluation of Non-Alcoholic Fatty Liver Disease Patients (비알콜성 지방간환자 평가를 위한 3.0T 고자기장 자기공명분광법을 이용한 PRESS 기법의 유용성)

  • Goo, Eun-Hoe
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5931-5936
    • /
    • 2012
  • This study was to evaluate the clinical usefulness of the PRESS technique based on the correlation between PRESS technique and biopsy results by applying 3.0T high magnetic field MRS technique for evaluation of non-alcoholic fatty liver disease patients. This experiment were carried out using a 3.0T magnetic resonance imaging equipment. The part data of each spectrum is taken by peak area integration. The part data of resonance peak was used to calculate relative ratio. MR spectral peak in patients with non-alcoholic fatty liver disease is from 0.9 to 1.6 ppm. According to MRS method study result, Patients with NAFLD were obtained with 94% sensitivity and 80% specificity(p=0.000). When compared to normal based on MRS and Biopsy results was valid correlation(r=0.79, p=0.04). Results for NAFLD(r=0.89, p=0.002) also showed a correlation. Therefore, PRESS technique to evaluate patients with non-alcoholic fatty liver disease, the distribution difference between normal liver and fatty liver part is significantly distinguished. Biopsy and MRS fatty liver peak ratio(%) proves high lipid over grade(r = 0.7).

Processing of Side Scan Sonar and SBP Data for the Artificial Reef Area (인공어초지역에 대한 사이드스캔소나와 SBP 탐사 자료처리)

  • Shin, Sung-Ryul;Lim, Min-Hyuk;Jang, Won-Il;Lim, Jong-Se;Yoon, Ji-Ho;Lee, Seong-Min
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.2
    • /
    • pp.192-198
    • /
    • 2009
  • Side scan sonar and SBP (sub-bottom profiler) play a very important role in the survey for seafloor imaging and sub-bottom profiling. In this study, we have acquired side scan sonar and SBP data from the artificial reef area. We applied digital image processing techniques to side scan sonar data in order to improve an image quality. For the enhancement of data quality and image resolution, we applied the typical seismic data processing sequence including gain recovery, muting, spectrum analysis, predictive deconvolution, migration to SBP data. We could easily estimate if artificial reef structures were settled properly and their distribution on the seafloor from the integrated interpretation of side scan sonar and SBP data. From the sampling analysis of seabed sediments, texture filtering of side scan sonar data and SBP data interpretation, we could evaluate the sediment type, distribution and thickness of seafloor sediments in detail.

Characteristics of InGaAs/GaAs/AlGaAs Double Barrier Quantum Well Infrared Photodetectors

  • Park, Min-Su;Kim, Ho-Seong;Yang, Hyeon-Deok;Song, Jin-Dong;Kim, Sang-Hyeok;Yun, Ye-Seul;Choe, Won-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.324-325
    • /
    • 2014
  • Quantum wells infrared photodetectors (QWIPs) have been used to detect infrared radiations through the principle based on the localized stated in quantum wells (QWs) [1]. The mature III-V compound semiconductor technology used to fabricate these devices results in much lower costs, larger array sizes, higher pixel operability, and better uniformity than those achievable with competing technologies such as HgCdTe. Especially, GaAs/AlGaAs QWIPs have been extensively used for large focal plane arrays (FPAs) of infrared imaging system. However, the research efforts for increasing sensitivity and operating temperature of the QWIPs still have pursued. The modification of heterostructures [2] and the various fabrications for preventing polarization selection rule [3] were suggested. In order to enhance optical performances of the QWIPs, double barrier quantum well (DBQW) structures will be introduced as the absorption layers for the suggested QWIPs. The DBWQ structure is an adequate solution for photodetectors working in the mid-wavelength infrared (MWIR) region and broadens the responsivity spectrum [4]. In this study, InGaAs/GaAs/AlGaAs double barrier quantum well infrared photodetectors (DB-QWIPs) are successfully fabricated and characterized. The heterostructures of the InGaAs/GaAs/AlGaAs DB-QWIPs are grown by molecular beam epitaxy (MBE) system. Photoluminescence (PL) spectroscopy is used to examine the heterostructures of the InGaAs/GaAs/AlGaAs DB-QWIP. The mesa-type DB-QWIPs (Area : $2mm{\times}2mm$) are fabricated by conventional optical lithography and wet etching process and Ni/Ge/Au ohmic contacts were evaporated onto the top and bottom layers. The dark current are measured at different temperatures and the temperature and applied bias dependence of the intersubband photocurrents are studied by using Fourier transform infrared spectrometer (FTIR) system equipped with cryostat. The photovoltaic behavior of the DB-QWIPs can be observed up to 120 K due to the generated built-in electric field caused from the asymmetric heterostructures of the DB-QWIPs. The fabricated DB-QWIPs exhibit spectral photoresponses at wavelengths range from 3 to $7{\mu}m$. Grating structure formed on the window surface of the DB-QWIP will induce the enhancement of optical responses.

  • PDF

A Clinicopathologic Analysis of Neck Masses (경부 종괴의 임상 및 병리학적 고찰)

  • Km Jeong-Ho;Oh Sang-Hoon;Kim Sang-Hyo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.13 no.1
    • /
    • pp.51-57
    • /
    • 1997
  • A mass appearing in the anterior or lateral side of neck often can be a diagnostic challenge. Differential diagnosis of the neck mass covers a broad spectrum of diseases and the proper evaluation and management of a neck mass requires an impressive amount of anatomic and pathologic information. Because improper diagnosis and management may convert a potentially curable malignant metastasis into incurable disease, a differential diagnosis must be considered in all patients who present with a neck mass. Authors reviewed 2,148 cases of neck mass who were diagnosed by surgical resection, biopsy or aspiration during the period between October 1982 to December 1993, excluding those with thyroid and parathyroid disease. The evaluated characteristics were age, sex, site of lesion, and pathologic diagnosis. The results were as follows: Of 2,148 cases of neck mass, the overall ratio of benign to malignant tumor was 3 : 1. In 1,603 cases of benign mass lesion, the most common disease was lymphadenitis(non-specific and tuberculosis) showing 53% incidence, the second was salivary gland tumor(13%), and the third was congenital lesion(12%). The minor problems such as lipoma and sebaceous cyst were 21 %. In the age distribution of benign lesion, tuberculous lymphadenitis showed peak incidence in second decade, non-specific lymphadenitis was main disease of childhood, salivary gland tumor was peak in fourth decade, and most of congenital lesions were diagnosed at the age below 15. In 545 malignant tumors, the most common lesion was metastatic cancer to cervical lymph nodes yielding 71 % incidence(head and neck primary 52%, infraclavicular primary 42%, unknown primary 5%), the second common disease was lymphoma(19%), and the third was salivary gland cancer(9%). In the age incidence of malignant tumor, 60% of them developed in the fifth and sixth decade, head and neck primary was more common in the fifth decade than sixth, however lymphoma showed higher incidence in sixth decade. In the analysis of mass location according to lymph node level grouping(I - V), lymphadenitis developed mostly in level V nodes, the next common occurring site was level IV in tuberculous lymphadenitis and level II in non-specific lymphadenitis. The majority of metastatic cancers were found in level IV and III, and common occurring site of lymphoma was in level II and IV. Pathologic diagnosis of neck masses were made by fine needle aspiration cytology 80 cases, incisional biopsy 533 cases, excisional surgery 1,399 cases, and neck dissection 116 cases. For the proper management of neck mass, a proper diagnostic modality should be selected from imaging techniques, cytology, biopsy or neck dissection, with the consideration of patient's age, history and clinical findings. The scapel biopsy could be used freely in the inflammatory disease or inoperable metastatic cancer, but it should be reserved in the curable metastatic cancer or clinically possible malignancy.

  • PDF

Effectiveness of multi-mode surface wave inversion in shallow engineering site investigations (토목관련 천부층 조사에서 다중 모드 표면파 역산의 효과)

  • Feng Shaokong;Sugiyama Takeshi;Yamanaka Hiroaki
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.26-33
    • /
    • 2005
  • Inversion of multi-mode surface-wave phase velocity for shallow engineering site investigation has received much attention in recent years. A sensitivity analysis and inversion of both synthetic and field data demonstrates the greater effectiveness of this method over employing the fundamental mode alone. Perturbation of thickness and shear-wave velocity parameters in multi-modal Rayleigh wave phase velocities revealed that the sensitivities of higher modes: (a) concentrate in different frequency bands, and (b) are greater than the fundamental mode for deeper parameters. These observations suggest that multi-mode phase velocity inversion can provide better parameter discrimination and imaging of deep structure, especially with a velocity reversal, than can inversion of fundamental mode data alone. An inversion of the theoretical phase velocities in a model with a low velocity layer at 20 m depth can only image the soft layer when the first higher mode is incorporated. This is especially important when the lowest measurable frequency is only 6 Hz. Field tests were conducted at sites surveyed by borehole and PS logging. At the first site, an array microtremor survey, often used for deep geological surveying in Japan, was used to survey the soil down to 35 m depth. At the second site, linear multichannel spreads with a sledgehammer source were recorded, for an investigation down to 12 m depth. The f-k power spectrum method was applied for dispersion analysis, and velocities up to the second higher mode were observed in each test. The multi-mode inversion results agree well with PS logs, but models estimated from the fundamental mode alone show f large underestimation of the depth to shallow soft layers below artificial fill.