• 제목/요약/키워드: specific power.

검색결과 2,635건 처리시간 0.035초

초전도케이블의 실계통 적용가능 개소 도출 및 적용효과 검토 (Specific Case selection and basic power system analysis for applying HTSC to KEPCO system)

  • 이승렬;윤재영;김종율
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.167-170
    • /
    • 2003
  • This study alms at analyzing a power system, in case of installing HTS cable in the system. First of all, we determine the case that HTS cable can be applied to KEPCO systems and analyze the static state of power system. Then we propose a solution of the problem resulting from the analysis.

  • PDF

배터리 에너지 저장장치를 이용한 10kW 풍력발전출력 안정화 시스템 개발 (Battery energy storage system for 10kW wind turbine output stabilization)

  • 오승진;한병문
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.36-37
    • /
    • 2010
  • This paper presents a simulation model and results of experiment about analysis of grid-tied wind turbine generator with batteries. The system consists of two inverters and a bidirectional DC/DC converter. These inverters are to capture the maximum active power under varying wind conditions and to keep the DC-link voltage magnitude at a specific level. And the bidirectional DC/DC converter makes battery charging or discharging depend on power gap between wind turbine output and local load.

  • PDF

IEEE 1344를 이용한 Agent형 전력 관리 시스템 프로토콜 설계 (Development of the Protocol for the Power Management Agent System with IEEE 1344)

  • 이종은;이건영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.105-107
    • /
    • 2005
  • The Power system is one of the biggest and complicated non-linear systems. It is necessary to develop the power defense system to manage the power system efficiently and to prevent from the power failure, black out in nationwide, that is caused by a specific bus or power transmission line. In this paper, the power system developed here is called 'Power Management Agent System' in which a protocol to communicate for this system is developed. The protocol is designed based on the IEEE 1344 for synchronized system with GPS. Also we developed a simulation system to demonstrate how to implement the protocol.

  • PDF

ESTABLISHMENT OF A MAINTENANCE PROGRAM TO PREVENT LOSS OF OFFSITE POWER IN NUCLEAR POWER PLANTS

  • Lee, Eun-Chan;Na, Jang-Hwan
    • Nuclear Engineering and Technology
    • /
    • 제45권6호
    • /
    • pp.791-794
    • /
    • 2013
  • Since the Fukushima accident in 2011, the importance of the electrical systems in nuclear power plants (NPPs) has been emphasized. The result has been that NPP regulators are enhancing their monitoring of loss of offsite power (LOOP) events. Korea Hydro & Nuclear Power Co. (KHNP) is reviewing the status and issues related to LOOPs, and is attempting to establish specific countermeasures to prevent LOOPs, because they can have severe consequences in the complicated maintenance schedule during an outage. A starting point for preventing LOOPs is the control of the loss of voltage (LOV)-initiating components. In order to reflect this in the risk assessment program, an LOV monitor is being developed for use during plant outages.

특수섬유에 의한 전력계통의 고장유발 과정 고찰 (A Study on the Procedure of Fault on Electric Power Systems by Special Fibers)

  • 임완권;김성식;정동학
    • 한국군사과학기술학회지
    • /
    • 제12권5호
    • /
    • pp.667-675
    • /
    • 2009
  • Faults can be generated at electric power systems by variety of both certain and uncertain reasons, which may cause harmful effects on electrical apparatuses under operation and stability of electric power system operations, and may also lead to great confusions and inconveniences to individual livings, public works, industrial activities, services, military affairs, etc.. In some cases, intentional inductions of faults are committed for specific purposes, and it is necessary to understand the procedures of fault by some foreign materials. In this paper, compositions and operations of electric power systems, summaries of electrical fault phenomena and fault protection, and restrictions to power system operation were outlined. And the analogies on the procedure of faults from former papers were introduced, and test results that revealed the validity of those analogies were also introduced.

Deployment of Radioactive Waste Disposal Facility with the Introduction of Nuclear Power Plants (NPP) in Kenya

  • Shadrack, A.;Kim, C.L.
    • Journal of Nuclear Fuel Cycle and Waste Technology
    • /
    • 제1권1호
    • /
    • pp.37-47
    • /
    • 2013
  • This paper describes basic plans for the development of a radioactive waste disposal facility with the introduction of Nuclear Power Plants (NPPs) for Kenya. The specific objective of this study was to estimate the total projected waste volumes of low- and intermediate-level radioactive waste (LILW) expected to be generated from the Kenyan nuclear power programme. The facility is expected to accommodate LILW to be generated from operation and decommissioning of nuclear power plants for a period of 50 years. An on-site storage capacity of 700 $m^3$ at nuclear power plant sites and a final disposal repository facility of more than 7,000 $m^3$ capacity were derived by considering Korean nuclear power programme radioactive waste generation data, including Kori, Hanbit, and APR 1400 nuclear reactor data. The repository program is best suited to be introduced roughly 10 years after reactor operation. This study is important as an initial implementation of a national LILW disposal program for Kenya and other newcomer countries interested in nuclear power technology.

Development of a Novel Tracking System for Photovoltaic Efficiency in Low Level Radiation

  • Choi, Jung-Sik;Ko, Jae-Sub;Chung, Dong-Hwa
    • Journal of Power Electronics
    • /
    • 제10권4호
    • /
    • pp.405-411
    • /
    • 2010
  • This paper proposes a novel tracking algorithm considering radiation to improve the power of a photovoltaic (PV) tracking system. The sensor method used in a conventional PV plant is unable to track the sun's exact position when the intensity of solar radiation is low. It also has the problem of malfunctions in the tracking system due to rapid changes in the climate. The program method generates power loss due to unnecessary operation of the tracking system because it is not adapted to various weather conditions. This tracking system does not increase the power above that of a power of tracking system fixed at a specific position due to these problems. To reduce the power loss, this paper proposes a novel control algorithm for a tracking system and proves the validity of the proposed control algorithm through a comparison with the conventional PV tracking method.

전력계통설비의 정지관리 체계화 방안에 대한 연구 (A Study on the Outage Management Standards for Power System)

  • 허정용;김철환;김재철;이건웅;이성진;이창규;조범섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.107-109
    • /
    • 2004
  • It is very important to operate a power system safely. An fault may causes the cascading outages in power system. Use of systematic, precise definitions related to the outages is essential for meaningful exchange of data. Moreover, it is necessary that specific instructions for reporting outages is developed. This paper presents the outage management for a power system. The outage managements of the many utilities are researched, which include the definition, classification, index and report of outage. Finally, the outage management standard is proposed, and the necessity and structure of KERC(Korean Electric Reliability Council) are presented

  • PDF

곤륜의 전침 자극이 뇌파에 미치는 영향 (The Effect of Electroacupuncture at the BL60 (Kollyun) on the EEG)

  • 이태영;이광규;장윤성;육상원;이창현;이상룡
    • Korean Journal of Acupuncture
    • /
    • 제20권2호
    • /
    • pp.31-46
    • /
    • 2003
  • Objectives : The aim of this study was to examine the effects of electroacupuncture(EA) at the BL60 (Kollyun) on normal humans using power spectral analysis. Methods : EEG power spectrum exhibit site-specific and state-related differences in specific frequency bands. In this study, power spectrum was used as a measure of complexity. 30 channel EEG study was carried out in 10 subjects $(10\;males;\;age=22.4{\pm}0.5$ years). Results : In alpha band, the power values at Fz during the non-acupoint treatment and at Fp2, T5 during the BL60-acupoint treatment significantly were decreased. In beta band, the power values at C3, Po2, O2, Oz during the BL60-acupoint treatment significantly were increased than the before-acupuncture treatment. In theta band, the power values at F7 during the BL60-acupoint treatment significantly was increased. However, the comparison with that before and after the treatment shows no significant differences in all channels.

  • PDF

내관$(PC_6)$의 황련해독탕 약침이 EEG 변화에 미치는 효과 (The Effect of Hwangryunhaedoktang Herbal Acupuncture at the $PC_6$(Naegwan) on the EEG)

  • 김동석;이상룡
    • Korean Journal of Acupuncture
    • /
    • 제21권3호
    • /
    • pp.39-58
    • /
    • 2004
  • Objectives : The aim of this study was to examine the effects of Hwangryunhaedoktang Herbal acupuncture at the PC6(Naegwan) on the EEC of normal human being by using power spectral analysis. Methods : EEC power spectrum exhibit site-specific and state-related differences in specific frequency bands. In this study, power spectrum was used as a measure of complexity. 32 channel EEC study was carried out in 11 subjects (11 males; age=27.8 years). Results : In ${\alpha}(alpha)$ band, the power values at T3, TT1, CP1, T5, Po2, O1, Oz channels(p<0.05) during the PC6-acupoint treatment were increased significantly. In ${\beta}(beta)$ band, the power values at TT1, CP1, T5, P3, Po2, O1, Oz channels(p<0.05) during the PC6-acupoint treatment were increased significantly. In ${\theta}(theta)$ band, the power values at T3, TT1, CP1, Po2, O1, Oz channels(p<0.05) during the PC6-acupoint treatment were increased significantly. In ${\delta}(delta)$ band, the power values at F4, T3, CP1, O1, Oz, O2 channels(p<0.05) during the PC6-acupoint treatment were increased significantly. Conclusions : This results suggest that Hwangryunhaedoktang Herbalacupuncture at the PC6 is significantly in ${\alpha}(alpha)$ band.

  • PDF