• Title/Summary/Keyword: sound absorption

Search Result 441, Processing Time 0.026 seconds

A Case Study on Inside Noise Reduction of Agricultural Tractor Cab(II) -Noise Reduction- (농용 트랙터의 안전캡 내부 소음 감소에 관한 연구(II) -소음 감소 효과-)

  • 유동호;김경욱;최창현
    • Journal of Biosystems Engineering
    • /
    • v.20 no.2
    • /
    • pp.127-132
    • /
    • 1995
  • In the first part of this paper, an analysis of the cab noise of a selected agricultural tractor was presented. In this study, using the results of the previous analysis, two passive noise control measures of the sound insulation and absorption were conducted to reduce the noise level inside the cab. These measures of noise control reduced the total noise level by 6.2㏈(A) at the operator position inside the cab. In order to further reduce the cab noise, particularly, of lower frequencies than 630Hz, stiffness and damping of the floor panel should be enforced. It was also suggested that a proper suspension for the cab mounting is necessary to reduce the level of structure-born noises.

  • PDF

A Study on the Absorption Characteristics of Soil Block and Soil Plaster as Eco-Friendly Building Materials (친환경 건축재료로서의 흙벽돌과 흙미장의 흡음 특성에 관한 연구)

  • Hwang, Seong Il;Chu, Mun Ki;Hwang, hey joo;Oh, yang ki
    • KIEAE Journal
    • /
    • v.7 no.3
    • /
    • pp.57-62
    • /
    • 2007
  • Most of current building materials are made of organic compounds or at least made with chemical treatments. Though easy to use and comparatively pay less, those materials are generally not enviornmentally sound. VOC is one of harmful effects. On contrary, natural materials such as soil are usually eco-friendly, and environmentally sustainable as well if not treated in autoclaves. Acoustica materials made of such environmentally sound and sustainable could be widely used. It is aimed to prove that soil based materials could be effectively used in acoustical fields rather than the other usual materials. Experiments with various types of soil blocks and soil plaster were performed. It is proved that the soil plaster has better apsorption features than cement plaster. Soil blocks have higher absorption cofficients than soil plaster, due to the thickness, and the absorption characteristics can be controlled by the design of the blocks.

Anechoic Chamber Design using Broadband Compact Absorber (패널형 흡음재를 이용한 무향실의 설계)

  • ;;Peter Brandstatt;Helmut V. Fuchs
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.393-396
    • /
    • 2003
  • Conventional method for designing and installing anechoic chambers is to utilize porous wedges for the sound absorbers. As cutoff frequency lowers down such as 63Hz or 50Hz, the corresponding long wedges diminish the free field area of the chamber. In this study, a new broadband compact absorber(BCA) is introduced which absorbs acoustic energy down to 50Hz. Most prominent is that it measures only 250mm thick. A freely vibrating panel between the non-fibrous absorbers allows tuned absorption at the low frequency region in addition to the high frequency absorption resulted from the conventional absorber installed at the front. Standing waves at low frequency range are suppressed as the BCA modules which are tuned to the corresponding modes absorb sound energy effectively, resulting in anechoic condition. Not only the low frequency performances, but the high frequency absorption is measured to meet adequate conditions for the anechoic chamber. Realized BCA chambers are presented.

  • PDF

Separate Reconstruction of Speed of Sound, Density, and Absorption Parameters in Ultrasound Inverse Scattering Tomography

  • Kwon, Sung-Jae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.2E
    • /
    • pp.18-23
    • /
    • 1999
  • This paper proposes a method of separately determining three intrinsic mechanical parameters of an unknown object in the framework of ultrasound inverse scattering tomography. Those parameters are the speed of sound, density, and absorption whose values are given as the solution of an inhomogeneous Helmholtz wave equation. The separate reconstruction method is mathematically formulated, the integral equations are discretized using the sinc basis functions, and the Newton-Raphson method is adopted as a numerical solver in a measurement configuration where the object is insonified by an incident plane wave over 360˚ and the scattered field is measured by detectors arranged in a rectangular fashion around it. Two distinct frequencies are used to separate each parameter of three Gaussian objects that are either located at the same position or separately from each other. Computer simulation results show that the separate reconstruction method is able to separately reconstruct the three mechanical parameters. The absorption parameter turns out to be a little difficult to reconstruct as compared with the other two parameters.

  • PDF

Investigation into influence of sound absorption block on interior noise of high speed train in tunnel (터널 내부 도상 블록형 흡음재의 고속철도차량 내부 소음에 미치는 영향에 대한 고찰)

  • Lee, Sang-heon;Cheong, Cheolung;Lee, Song-June;Kim, Jae-Hwan;Son, Dong-Gi;Sim, Gyu-Cheol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.4
    • /
    • pp.223-231
    • /
    • 2018
  • Recently, due to various environmental problems, blast tracks in tunnel are replaced with concrete tracks, but they have more adverse effects on noise than blast tracks so that additional noise measures are needed. Among these measures, sound-absorbing blocks start to be used due to its easy and quick installation. However, the performance of sound absorption blocks need to be verified under real environmental and operational conditions. In this paper, interior noise levels in KTX train cruising in Dalseong tunnel are measured before and after the installation of sound-absorbing blocks and the measured data are analyzed and compared. Additionally, noise reduction are estimated by modeling the high speed train, the tunnel and absorption blocks. Measurement devices and methods are used according to ISO 3381 and the equivalent sound pressure levels during the cruising time inside the tunnel are computed. In addition to overall SPLs(Sound Pressure Levels), 1/3-octave-band levels are also analyzed to account for the frequency characteristics of sound absorption and equipment noise in a cabin. In addition, to consider the effects of train cruising speeds and environmental conditions on the measurements, the measured data are corrected by using those measured during the train-passing through the tunnels located before and behind the Dalseong tunnel. Analysis of measured results showed that the maximum noise reduction of 6.8 dB (A) can be achieved for the local region where the sound-absorbing blocks are installed. Finally, through the comparison of predicted 1/3-octave band SPLs for the KTX interior noise with the measurements, the understanding of noise reduction mechanism due to sound-absorbing blocks is enhanced.

Hot Pressing Technology for Improvement of Density Profile and Sound Absorption Capability of Particleboard (파티클보드의 밀도경사와 흡음성 개선을 위한 열압기술)

  • Park, Hee Jun;Kim, Hyun-Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.25-33
    • /
    • 2002
  • Improvement of density profile and sound absorption capability of particleboard was attempted. Three types of hot pressing methods examined ; flat-platen pressing method (A-type pressing), hot pressing in forming box (B-type pressing), and hot pressing set up jagged caul in forming box (C-type pressing). The raw materials were larch(Larix leptolepis (S, et. Z.) Gorden) shavings, phenol formaldehyde resin, and the particleboard perforated with stair type. The physical and mechanical properties such as specific gravity, bending strength (MOR), internal bonding strength (IB) and sound absorption coefficients were examined. The results are summarized as follows : 1) The MOR and internal bonding strength of the board pressed in forming box were higher than those of flat-platen pressed board. 2) The minimum density to average density ratio in thickness direction which pressed in forming box showed about 923%, in the case of 35 mm commercial particleboard and 50 mm flat-platen pressed board, its values showed about 66.4% and 865% respectively. 3) Sound absorption coefficients of the particleboard perforated with stair type were higher than those of flat-plated pressed board and commercial particleboard.

The evaluation of Sound Power Level and development of index for Sound Quality of Vacuum Cleaner according to performances of Sound Absorbtion Materials (흡음재 성능에 따른 진공청소기의 음향파워 평가 및 음질인덱스 개발)

  • Kwon, Hyuk-Je;Lee, Sang-Kwon;Gu, Jin-Hoi;Lee, Hyun-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.112-120
    • /
    • 2008
  • Today, the use of a vacuum cleaner gave us the higher quality of life than past time, but sometimes made us w1comfortable in the house because of the specific noise that is annoying. So we need to study how sound absorbtion materials affect sound power level and sound quality with sound metrics. In this paper, we will measure and calculate sound power level for vacuum cleaner and analyze characteristics of the noise for 10 Signals according to materials positioned in vacuum cleaner. The multiple regression analysis can estimate the nonlinear characteristics of relation between subjective evaluation and sound metrics. So we will develop sound quality index for vacuum sound.

  • PDF