• Title/Summary/Keyword: soil bearing capacity

Search Result 553, Processing Time 0.035 seconds

Behavior of High-Speed Rail Roadbed Reinforced by Geogrid under Cyclic Loading (지오그리드로 보강한 고속철도 노반의 거동 특성)

  • 신은철;김두환
    • Journal of the Korean Society for Railway
    • /
    • v.3 no.2
    • /
    • pp.84-91
    • /
    • 2000
  • The general concept of reinforced roadbed in the high-speed railway is to cope with the soft ground for the bearing capacity and settlement of foundation soil. The cyclic plate load tests were performed to determine the behavior of reinforced ground with multiple layers of geogrid underlying by soft soil. With the test results, the bearing capacity ratio, elastic rebound ratio, subgrade modulus and the strain of geogrids under loading were investigated. Based on these plate load tests, laboratory model tests under cyclic loading were conducted to estimate the effect of geogrid reinforcement in particular for the high-speed rail roadbed. The permanent settlement and the behavior of earth pressure in reinforced roadbed subjected to a combination of static and dynamic loading are presented.

  • PDF

Bearing Capacity Study for Small-Scale Testing of Rotary Pile with Helix Plate (축소모형 로타리 파일의 나선날개에 따른 지지성능에 관한 연구)

  • Shin, Eun-Chul;Kim, Kyeong-Sig;Moon, Hyeong-Rok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.1
    • /
    • pp.37-46
    • /
    • 2016
  • Rotary pile consists a single or multiple helix plate and it is installed into the ground using the rotation of the helix plate. Rotary pile in soft ground is able to be supported by pile shaft and helix plate. When the pile is installed into hard layer relatively, the end bearing capacity is possible to be increased by the lower helix plate. In this paper, small-size rotary piles were manufactured with using steel pipe which is reduced to 1/5 size of the rotary pile on the construction field. Pile load test was carried out on the foundation soil which was formed by weathered soft soil. The bearing capacity of small-scale piles depends on the number of helix plate, the length of plate diameter, and an interval of plates, respectively. The bearing capacity of pile increases about 40% with 3 helix plate and it is also confirmed that the bearing capacity is improved about 10% as the increment of plate interval.

An Experimental Study on Settlement Reduction of Artificial Reef using Geosynthetics (토목섬유를 이용한 인공어초 침하 저감에 대한 실험 연구)

  • Ha, Yong-Soo;Kim, Yun-Tae
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.3
    • /
    • pp.21-29
    • /
    • 2015
  • An artificial reef is a human-made underwater structure to improve marine environment and to provide a habitat for fish and other ocean wildlife. An artificial reef is placed on the ocean ground. In soft ground like most of the seabed soil, the ground has been settled due to weight of artificial reef. This study investigated the bearing capacity and settlement reduction effect of geosynthetics which were reinforced on the ground in a large size tank. Penetration tests and large soil tank laboratory tests were performed to investigate settlement reduction effect and bearing capacity on artificial reef with different spreading area of geogrid. Laboratory test results indicate that the spreaded geogrid under artificial reef reduce the settlement of ground and increase bearing capacity of ground.

A Study of Improvement Pile friction in Marine Clay using Electrokinetics Treatment (전기동역학을 이용한 해성 점토 지반내의 말뚝 마찰지지력 향상에 관한 연구)

  • Lee, Kwang-Yeol;Gu, Tae-Gon;Tjandra, Daniel;Hyun, Jae-Duck
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.211-218
    • /
    • 2004
  • The objective of this study is to enhance the ultimate bearing capacity of piles embedded in marine clay by electrokinetic(EK). The focus of improvement is at interlace between soil and pile. A series laboratory test was performed in EK cell. In each of test, the pile in the centre as anode is surrounded by cathode and it was installed in the vicinity of pile with triangular layout. The pile was made by stainless and embedded with 30cm of depth. Afterward, the DC voltage was applied to electrode over period of time. It caused flowing water from anode to cathode, thus the soil in the center of box has higher bearing capacity value than in the side of box has. It is shown by increasing of un-drained shear strength(Cu) near the pile and also ultimate bearing capacity of pile increase after EK treatment. In the future work, the continuous of this study is finding the effective DC voltage and makes EK treatment more applicable in the field.

  • PDF

Analyzing the bearing capacity of shallow foundations on two-layered soil using two novel cosmology-based optimization techniques

  • Gor, Mesut
    • Smart Structures and Systems
    • /
    • v.29 no.3
    • /
    • pp.513-522
    • /
    • 2022
  • Due to the importance of accurate analysis of bearing capacity in civil engineering projects, this paper studies the efficiency of two novel metaheuristic-based models for this objective. To this end, black hole algorithm (BHA) and multi-verse optimizer (MVO) are synthesized with an artificial neural network (ANN) to build the proposed hybrid models. Based on the settlement of a two-layered soil (and a shallow footing) system, the stability values (SV) of 0 and 1 (indicating the stability and failure, respectively) are set as the targets. Each model predicted the SV for 901 stages. The results indicated that the BHA and MVO can increase the accuracy (i.e., the area under the receiving operating characteristic curve) of the ANN from 94.0% to 96.3 and 97.2% in analyzing the SV pattern. Moreover, the prediction accuracy rose from 93.1% to 94.4 and 95.0%. Also, a comparison between the ANN's error decreased by the BHA and MVO (7.92% vs. 18.08% in the training phase and 6.28% vs. 13.62% in the testing phase) showed that the MVO is a more efficient optimizer. Hence, the suggested MVO-ANN can be used as a reliable approach for the practical estimation of bearing capacity.

A Case Study on the Design of Drilled Shaft on Soft Ground in Vietnam (베트남 연약지반에서의 현장타설말뚝 설계 사례)

  • Seo, Won-Seok;Cho, Sung-Han;Choi, Ki-Byung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.591-604
    • /
    • 2008
  • In this study, two design examples of drilled shafts on soft ground in Ho-Chi-Minh City, Vietnam are introduced. One is for a 27-story apartment and the other is for a Arch bridge over Saigon river. Unlikely the normal cases in Korea, all of the bored pile foundations are supposed to be placed on soil layers. Therefore, skin friction between pile and ground is the most crucial design parameter. Three methods using SPT N value of sandy soil -Korean Road Bridge Code(1996), Reese and Wright (1977), and O'Neill and Reese (1988)- were adopted to obtain an ultimate axial bearing capacity. In order to verify the calculated bearing capacity, 3 sets of static load test and a Osterberg Cell test were performed at an apartment site and a bridge site respectively. LRFD (Load Resistance Factored Design) method was compared with ASD (Allowable Stress Design) method. On application of ASD method, safety factor for skin friction was adopted as 2 or 3 while safety factor for end bearing was 3. The design bearing capacities from ASD method matched well with those from LRFD method when safety factor for skin friction was adopted as 2.

  • PDF

Experimental analysis of rocking shallow foundation on cohesive sand

  • Moosavian, S.M. Hadi;Ghalandarzadeh, Abbas;Hosseini, Abdollah
    • Earthquakes and Structures
    • /
    • v.22 no.6
    • /
    • pp.597-608
    • /
    • 2022
  • One of the most important parameters affecting nonlinearsoil-structure interaction, especially rocking foundation, is the vertical factor of safety (F.Sv). In this research, the effect of F.Sv on the behavior of rocking foundations was experimentally investigated. A set of slow, cyclic, horizontal loading tests was conducted on elastic SDOF structures with different shallow foundations. Vertical bearing capacity tests also were conducted to determine the F.Sv more precisely. Furthermore, 10% silt was mixed with the dry sand at a 5% moisture content to reach the minimum apparent cohesion. The results of the vertical bearing capacity tests showed that the bearing capacity coefficients (Nc and Nγ) were influenced by the scaling effect. The results of horizontal cyclic loading tests showed that the trend of increase in capacity was substantially related to the source of nonlinearity and it varied by changing F.Sv. Stiffness degradation was found to occur in the final cycles of loading. The results indicated that the moment capacity and damping ratio of the system in models with lower F.Sv values depended on soil specifications such cohesiveness or non-cohesiveness and were not just a function of F.Sv.

The Bearing Capacity of Top Base Foundations in Soft Ground (연약지반상 팽이기초 적용에 따른 지지특성)

  • Kim, Chan-Kuk;Kim, Hak-Moon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.401-414
    • /
    • 2010
  • Top Base Foundation(TBF) is a stabilization method for light weight structures particularly in the soft ground. It is widely used for the increment of bearing capacity and restraining settlement of foundations when the bearing capacity of ground is not enough. However, when the design values from exiting Japanese standard are compared with the observation values from the field measurement, the bearing capacity of exiting standard estimated smaller For this reason, it is necessary to establish more reasonable prediction technique considering to understand the behavior of TBF in soft ground. In this study, 1/5 scale model tests were performed in the laboratory. Also, full scale tests were carried out in order to investigate the behavior of TBF with various shapes. In addition, about 100 sites measurement data were evaluated to investigate the behavior of TBF in various ground conditions. Based on the results of the model tests and field measurement data, it was possible to establish more reasonable the bearing capacity equation of TBF considering various N-value of soil, the effect of underground water and failure shapes.

  • PDF

A Study on Bearing Capacity Characteristics of Group Crushed-Stone Compaction Piles (군쇄석다짐말뚝의 지지력 특성에 관한 연구)

  • Hwang, Geun-Bae;Lee, Min-Hee;Shin, Hyeon-Cheol;Choi, Yong-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.705-712
    • /
    • 2005
  • Among soft ground treatment methods with granular soil used in domestic, the sand compaction pile method has been utilized greatly, but, as a result of exhaustion of sand and increase of unit cost, a necessity of an alternative method is suggested. In this study, the static load tests for group crushed-stone compaction piles which were constructed at in-situ site were performed. Pile diameter was 700mm and area of loading plates were changed. The static load tests of single and group piles were performed for area replacement ratio of 20, 30 and 40%. Based on test results, bearing capacity of group crushed-stone compaction pile were estimated. The more both single pile and group pile increase, the more yield bearing capacity tended to increase. Also, the yield bearing capacity of a group pile is about 50% less than the yield bearing capacity of a single pile. If the ground reinforced with the crushed-stone compaction pile is replacement ratio of $20{\sim}40%$, RIYB of both single pile and group pile increases qualitative tendency of linear more than original ground

  • PDF

Evaluation of Bearing Capacity of Piled Raft Foundation on OC Clay using Centrifuge and Numerical Modeling (원심모형 실험과 수치해석을 이용한 과압밀 지반에서의 piled raft 기초의 지지력 평가)

  • Park, Jin-Oh;Choo, Yun-Wook;Kim, Dong-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.376-387
    • /
    • 2009
  • Piled raft foundation is a geotechnical composite construction to support the superstructure by pile-soil-raft interaction. General conventional design for piled raft doesn't consider the contribution of a raft. This is very conservative and requires more piles to satisfy the factor of safety. It is important to evaluate the load sharing features of piled raft. In this research, this characteristics of piled raft evaluated using both centrifuge and numerical modelings. The ultimate bearing capacity of piled raft foundation was also evaluated and predicted through comparisons of ultimate bearing capacity of single pile (SP), unpiled raft (UR), freestanding pile group (FPG) and piled raft (PR). $\xi_{pr}$ and $\eta$ were determined by centrifuge model tests to simply evaluate the ultimate bearing capacity of piled raft and bearing capacity of piled raft was predicted using the calibrated numerical model based on the centrifuge tests and laboratory tests data.

  • PDF