• Title/Summary/Keyword: smoother

Search Result 465, Processing Time 0.03 seconds

SURFACE ROUGHNESS OF EXPERIMENTAL COMPOSITE RESINS USING CONFOCAL LASER SCANNING MICROSCOPE (공초점 레이저 주사 현미경을 이용한 실험적 레진의 표면 조도에 대한 연구)

  • Bae, J.H.;Lee, M.A.;Cho, B.H.
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of a new resin monomer, filler size and polishing technique on the surface roughness of composite resin restorations using confocal laser scanning microscopy. By adding new methoxylated Bis-GMA (Bis-M-GMA, 2,2-bis[4-(2-methoxy-3-methacryloyloxy propoxy) phenyl] propane) having low viscosity, the content of TEGDMA might be decreased. Three experimental composite resins were made: EX1 (Bis-M-GMA/TEGDMA = 95/5 wt%, 40 nm nanofillers); EX2 (Bis-M-GMA/TEGDMA = 95/5 wt%, 20 nm nanofillers); EX3 (Bis-GMA/TEGDMA = 70/30 wt%, 40 nm nanofillers). Filtek Z250 was used as a reference. Nine specimens (6 mm in diameter and 2 mm in thickness) for each experimental composite resin and Filtek Z250 were fabricated in a teflon mold and assigned to three groups. In Mylar strip group, specimens were left undisturbed. In Sof-lex group, specimens were ground with #1000 SiC paper and polished with Sof-lex discs. In DiaPolisher group, specimens were ground with #1000 SiC paper and polished with DiaPolisher polishing points. The Ra (Average roughness), Rq (Root mean square roughness), Rv (Valley roughness), Rp (Peak roughness), Rc (2D roughness) and Sc (3D roughness) values were determined using confocal laser scanning microscopy. The data were statistically analyzed by Two-way ANOVA and Tukey multiple comparisons test (p = 0.05). The type of composite resin and polishing technique significantly affected the surface roughness of the composite resin restorations (p < 0.001). EX3 showed the smoothest surface compared to the other composite resins (p < 0.05). Mylar strip resulted in smoother surface than other polishing techniques (p < 0.05). Bis-M-GMA. a new resin monomer having low viscosity, might reduce the amount of diluent, but showed adverse effect on the surface roughness of composite resin restorations.

Experimental brush wear pattern and cariostatic effect of Biscover (Biscover의 잇솔질에 따른 마모양상과 항우식 효과)

  • Oh, Eun-Ju;Park, Song-Soo;Jang, Mun-Ju;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.38 no.3
    • /
    • pp.214-222
    • /
    • 2008
  • Objective: The aim of this study was to investigate the experimental brush wear pattern of a light cured surface sealant, Biscover (Bisco, Schaumburg, IL), and to evaluate its cariostatic effect. Methods: Caries-free human premolars were used for the Biscover coating group (n = 90) and the control group (n = 10). The Biscover coating group was randomly assigned to nine subgroups of 10 each and the control group was assigned to two subgroups of 5 each according to the number of brushing strokes. An experimental 3-body wear test was conducted under different strokes of wear test. Tooth-brushing was accomplished with movement of each brush head set at a frequency of 100 rpm under a force of 1.5N, Surface roughness was tested before, and after Biscover coating, and after brushing. Then, each of the 10 teeth of both groups were placed in artificial caries inducing solution for 7 days. All tooth surfaces were assessed using scanning electron microscopy. Results: Biscover coated surfaces showed a smoother texture than enamel surfaces. The roughness was increased after experimental brushing and after 10,800 brushing strokes, the whole layer of Biscover wore out. However, teeth in the Biscover coating group had a cariostatic effect in cariogenic conditions. Conclusions: We suggest that white lesions in orthodontic patients can be suppressed by topical applications of Biscover.

Shear bond strength of rebonded ceramic brackets (세라믹 브라켓의 재접착이 전단 결합 강도에 미치는 영향)

  • Sung, Ji-Young;Kang, Kyung-Hwa
    • The korean journal of orthodontics
    • /
    • v.39 no.4
    • /
    • pp.234-247
    • /
    • 2009
  • Objective: The purpose of this study was to evaluate the shear bond strength of rebonded ceramic brackets according to each condition and find an appropriate method to rebond ceramic brackets with proper shear bond strength in clinical practice. Methods: The study consisted of 12 experimental groups, according to the types of brackets, debonding methods, and treatment methods of the bracket base. Shear bond strength was measured, and adhesive residues left on the tooth surface were assessed. The base of the bracket was examined under scanning electron microscopy. Results: The shear bond strength of the monocrystalline ceramic bracket group was significantly higher than thatof the polycrystalline bracket group with only sandblasting (p < 0.05). There was no significant difference in shear bond strength between groups that used rebonded brackets which were debonded with shear force and debonded with laser (p > 0.05). The shear bond strength of the sandblasted/silane group was significantly higher than that of the selectively grinded group with a low-speed round bur and the sandblasted only group (p < 0.001). The retentive structure was more presented in groups where laser was applied than in groups where shear force was applied to debond brackets prior to rebonding. The bracket bases which were treated before rebonding presented smoother surfaces than new brackets. Conclusions: Shear bond strength could be increased by applying a silane coupling agent after sandblasting before rebonding. Also, the bond strength of the selectively grinded group with a low-speed round bur and the sandblasted group showed acceptable bond strength for clinical orthodontic treatment.

Study on the effect of soldering methods on the characteristics of the Ni-Cr alloy (납착 방법이 치과용 금속의 성상(性狀)에 미치는 영향에 관한 연구)

  • Kim, Chul-Hyung;Song, Young-Gyun;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.53-60
    • /
    • 2012
  • Purpose: The purpose of this study was to compare Ni-Cr alloy property of gas-oxygen torch soldering and infrared welding using optical microscope and Electron Probe Micro Analyzer (EPMA). Materials and methods: Ni-Cr alloys were casted for specimens. Specimens had 3.0 mm diameter, 30.0 mm length and were divided into two groups. Each group had 4 specimens. One group was for gas-oxygen torch soldering and the other was infrared welding. Specimens were cut with low-speed disc and soldered each other with gas-oxygen torch and infrared machine. After soldering and polishing, specimens were observed at 3 points (soldering point, 5 mm distance point, 10 mm distance point) with optical microscope and analyzed 3 points (soldering point, 5 mm distance point, 10 mm distance point with EPMA. Results: The results of this study were as follows: 1. The observation of gas-oxygen torch soldering at 10 mm distance point under the optical microscope was not founded any specific surface properties, but some crack lines were observed at 5 mm distance and soldering point. 2. There were no crack lines were founded at the observation of infrared welding at 10 mm distance and 5 mm distance points under the optical microscope. However, at the 5 mm distance, the surface was not smooth enough compared with at 10 mm distance point. Some crack lines were observed at the welding point as well. 3. In the EPMA analysis of the gas-oxygen torch soldering, the component of Ni was increased by 4.5%, Cr was increased by 7.5% than that of the Ni-Cr alloy at the 10.0 mm distance. At the 5 mm distance, the component of Ni was decreased by 6.1%, Mo was increased by 9.0% than that of the Ni-Cr alloy but Cr was equally shown at the 5.0 mm distance. Only Ni was shown at the soldering point. 4. In the EPMA analysis of the infrared welding, the component of Ni was increased by 9.1%, Cr was increased by 0.4% than that of the Ni-Cr alloy but Al was equal at the 10.0 mm distance. At the 5 mm distance, the component of Ni was increased by 4.7%, Cr was increased by 4.7% and Al was increased by 0.1% than that of the Ni-Cr alloy. At the welding point, the component of Ni was increased by 8.8%, Cr was increased by 8.2% than that of the Ni-Cr alloy. Conclusion: From these results, at the 5 mm distance from the soldering point, the surface of the infrared welding was more smoother than that of the gas-oxygen torch soldering. On the EPMA analysis, the component of the specimens with infrared welding was more similar than that of the gas-oxygen torch soldering compared with the component of the Ni-Cr alloy.

COMPARATIVE STUDY OF FLUORIDE RELEASE AND RE-UPTAKE OF SEVERAL RESTORATIVE MATERIALS (수종 수복재에 불소 도포제 적용 후 불소유리에 관한 비교연구)

  • Kim, Soo-Yeon;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.3
    • /
    • pp.408-419
    • /
    • 2007
  • In the child, it is very important that he/she will have the ability to suppress aesthetic restorative materials of secondary caries. With the representative preventive material against caries, the importance of fluoride is more emphasized. This study examined the differences in fluoride release and re-uptake among some restorative materials, following a treatment of APF gel and fluoride varnish. The surface roughness was observed under scanning electron microscope. Studying this will provide for the research to find effective restorative materials and fluoride type in tooth caries prevention. It is applied from presence at a clinic that restorative materials are resin, flowable resin, compomer and glass ionomer. Fluoride release was measured at 24-hour intervals for 7 days, 3-day intervals from 8th to 38th day using an ion-selective electrode and analyzer. Then, the materials were treated with the fluoride gel and fluoride varnish respectively, fluoride release was measured and specimens were evaluated under scanning electron microscope for 4 weeks. It was concluded that 1. Fluoride was released for 38 days from restorative materials under 1 ppm in case of flowable resin, 1-2 ppm in compomer and 2-8 ppm in glass ionomer, a few of fluoride was released after 45 days 2. Fluoride has more releasing after application of APF gel than fluoride varnish. Fluoride re-uptake was observed under 0.6-0.2 ppm in fluoride varnish and 0.6-2.6 ppm in APF gel after starting the procedure one day(p<0.05). For the remaining 4 weeks, they demonstrated a similar release. 3. Specimens were evaluated under scanning electron microscope. Applied fluoride in the experimental group surface was rougher than the control group that did not receive fluoride application. Fluoride varnish group had a smoother surface than both the APF gel group and the varnish APF gel group that received a fluoride application.

  • PDF

Study of the Tone Variation on Juniperus chinensis L. and Populus glandulosa Uyeki by Photographs (사진상(寫眞上)에 나타난 향나무(Juniperus chinensis L.)와 수원사시나무(Populus glandulosa Uyeki)의 색조변화(色調變化)에 관(關)한 연구(硏究))

  • Kim, Kap Duk
    • Journal of Korean Society of Forest Science
    • /
    • v.13 no.1
    • /
    • pp.1-24
    • /
    • 1971
  • In order to elucidate the feasibility to identify the plant species through the photographic tone this study was made. In this study the author made photographs of Juniperus chinensis L., and Populus glandulosa Uyeki, with the panchromatic film using either yellow filter or red filter in different seasons respectively. The author analyzed the value of tone variation at the level of stereoscopic view of the same photographs by using tone scale and Automatic Micro-Photo-Densitometer. The results obtained are summarized as follows: A. Tone scale reading 1. The tone of Populus glandulosa Uyeki was darker than that of Juniperus chinensis L. in a photograph. 2. Regardless of the tree species, tone of photographs obtained with yellow filter was darker than that with red filter. 3. Along the progresses of seasons, the photographic tone was changed. That is, from the spring to the summer it showed darker and than, from the summer to winter it changed lighter. 4. During winter and spring the discrimination between the both species of trees can be easily made by stereoscopic view whether there are leaves on the tree or not rather than by tone observation. 5. Regardless of tree species, variation of tone due to the age was noticed. The older trees have darker tone than the younger one. 6. It is recognized that the yearly difference depends on insolation quantities. 7. The highest reflex light-waves were in between $600m{\mu}$ and $660m{\mu}$ for both species of trees. B. Density reading 1. For the density reading, there was the same tendency as in tone scale reading. 2. The changes of peaks of the scanning curves with Populus glandulosa Uyeki is smoother and takes place in lower position than with Juniperus chinensis L. 3. The scanning curves on the 20th May was smoothest, and change of peaks increased gradually according to the season progresses. 4. In relation to the types of filter the photographs with yellow filter showed less changes of peaks then that with red filter.

  • PDF

Optical Property of Super-RENS Optical Recording Ge2Sb2Te5 Thin Films at High Temperature (초해상 광기록 Ge2Sb2Te5 박막의 고온광물성 연구)

  • Li, Xue-Zhe;Choi, Joong-Kyu;Lee, Jae-Heun;Byun, Young-Sup;Ryu, Jang-Wi;Kim, Sang-Youl;Kim, Soo-Kyung
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.5
    • /
    • pp.351-361
    • /
    • 2007
  • The samples composed of a GST thin film and the protective layers of $ZnS-SiO_2$ or $Al_2O_3$ coated on c-Si substrate were prepared by using the magnetron sputtering method. Samples of three different structures were prepared, that is, i) the GST single film on c-Si substrate, ii) the GST film sandwiched by the protective $ZnS-SiO_2$ layers on c-Si substrate, and iii) the GST film sandwiched by $Al_2O_3$ protective layers on c-Si substrate. The ellipsometric constants in the temperature range from room temperature to $700^{\circ}C$ were obtained by using the in-situ ellipsometer equipped with a conventional heating chamber. The measured ellipsometric constants show strong variations versus temperature. The variation of ellipsometric constants at the temperature region higher than $300^{\circ}C$ shows different behaviors as the ambient medium is changed from in air to in vacuum or the protective layers are changed from $ZnS-SiO_2$ to $Al_2O_3$. Since the long heating time of 1-2 hours is believed to be the origin of the high temperature variation of ellipsometric constants upon the heating environment and the protective layers, a PRAM (Phase-Change Random Access Memory) recorder is introduced to reduce the heating time drastically. By using the PRAM recorder, the GST samples are heated up to $700^{\circ}C$ decomposed preventing its partial evaporation or chemical reactions with adjacent protective layers. The surface image obtained by SEM and the surface micro-roughness verified by AFM also confirmed that samples prepared by the PRAM recorder have smoother surface than the samples prepared by using the conventional heater.

Abnormal Fractal Correlation of Heart Rate in Children with Neurocardiogenic Syncope (소아 신경심장성 실신환자에서 비정상적 심박수 프랙탈 상관에 대한 연구)

  • Kim, Keoung-Young;Joo, Eun-Young;Yum, Myung-Kul;Oh, Je-Wen;Kim, Chang-Ryul;Kim, Nam-Su;Lee, Cheol-Beom;Noh, Chung-Ill
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.9
    • /
    • pp.1114-1119
    • /
    • 2002
  • Purpose : The purposes of this study were to determine short- and long-term fractal correlation behavior of heart rates during daily activity in patients with neurocardiogenic syncope. Methods : Twenty five patients with histories of neurocardiogenic syncope episodes were included. Their analogue 24h ambulatory Holter electrocardiograms were analyzed. The tape was digitized and the digitized electrocardiograms were partioned into sections of one hour. Then their RR intervals were measured and 20,000 points of RRI were used. To quantify the fractal correlation behavior, we employed the detrended fluctuation analysis, and short-term($n{\leq}16$, ${\alpha}_1$) and long-term(n>16, ${\alpha}_2$) fractal scaling exponents were calculated. Results : When compared to control, 24-hour average values of ${\alpha}_1$ and all ${\alpha}_1$ values at quarters of each day were significantly higher in patients with syncope. On the contrary, their 24-hour average value of ${\alpha}_2$ and all ${\alpha}_2$ values at quarters of each day were lower in patients with syncope. However, statistical significances were found in 24-hour average value of ${\alpha}_2$ and in ${\alpha}_2$ value at MN-6AM. Conclusion : In the syncope patients with neurocardiogenic syncope, short-term fractal scaling exponents of RR interval was significantly high throughout the day. Therefore, their RR intervals were smoother in the short term scale and had a tendency to continue in the same direction of increase or decrease, which may contribute to persistent decrease in heart rate during a syncopal attack.

Parametric Images of Standardized Uptake Values using P-18-FDG Attenuation Corrected Whole Body PET (F-18-FDG감쇠보정 전신 PET을 이용한 표준섭취계수 추정과 매개변수 영상의 구성)

  • Kim, Kyeong-Min;Kwark, Cheol-Eun;Lee, Dong-Soo;Jeong, Jae-Min;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Kim, Yong-Jin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.560-569
    • /
    • 1996
  • Background and Purpose : Standardized uptake value(SUV) has been used as a quantitative index for differentiating benign and malignant tumors with F-18-FDG PET In this study, we produced whole body parametric images of SUV(WBPIS) by body weight normalization, and validated the values by comparison with SUV's calculated with regional scans. Subjects and Methods : Whole body scans were followed by regional scans sequentially on 23 patients. In whole body study, transmission and emission scans were acquired for 2 minutes and 6 minutes for each bed position, respectively. In regional study, transmission and emission scans were acquired for 20 minutes. Measured and segmented/ smoothed attenuation correction were applied using these 2 min transmission scans in whole body studies. The effects of attenuation correction on SUVs were evaluated quantitatively using F-18 filled cylindrical phantom. The mean and peak SUVs obtained from WBPIS were compared with SUVs of the regional scans. Results : In phantom studies, with any method of attenuation correction using regional or whole body studies of phantom, SUVs were nearly consistent. In whole body scan, SUV obtained using measured attenuation correction method was a little higher than SUV of regional scan. SUV obtained using segmented/smoothed attenuation correction method was a little lower. In patient studies, WBPIS using segmented/smoothed attenuation correction method was much smoother and more readable. SUVs of WBPIS obtained with both methods of attenuation correction were well correlated with SUVs of regional scans(r=0.9). SUVs of WBPIS with measured attenuation correction method were 5% lower than SUVs of regional scans. SUVs of WBPIS with segmented/smoothed attenuation correction method were 10% lower than SUVs of regional scans. The differences of SUVs of WBPIS by the two attenuation correction methods were relatively small compared with the possible differences derived from biological characteristics of tumors. Conclusion : We concluded that WBPIS could be useful in the quantification of tumor as well as in localization of whole body lesions, which were often outside the field of view in regional scan. WBPIS made using segmented/smoothed attenuation correction method could be used in clinical routines and SUVs from attenuation corrected F-18-FDG PET could be used interchangeably with SUVs of regional studies.

  • PDF

Surface roughness and $Candida$ $albicans$ adhesion to flexible denture base according to various polishing methods (연마방법에 따른 탄성의치의 표면거칠기와 $Candida$ $albicans$의 부착율 변화)

  • Oh, Ju-Won;Seo, Jae-Min;Ahn, Seung-Keun;Park, Ju-Mi;Kang, Cheol-Kyun;Song, Kwang-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.106-111
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the effect of 3 chairside polishing methods and laboratory polishing methods on surface roughness and $C.$ $albicans$ adhesion of polyamide denture base. Materials and methods: Using contact profilometer, the surface of polyamide specimens ($25{\times}15{\times}2mm$) was studied after conventional polishing without finishing and after chiarside polishing with 2 chiarside polishing kits and chairside-pumice polishing following finishing with tungsten carbide bur. To evaluate the adhesion of $C.$ $albicans$, $C.$ $albicans$ suspension was overlayed on the test specimen. And the specimens were incubated for 2 hours. Imprint culture method was achieved and counted the colony on the agar plate. Polished polyamide were evaluated using a scanning electron microscope. The statistics were conducted using one-way ANOVA and in case of difference, Scheffe test and Tamhane's T2 test were used. Results: Surface roughness (Ra) of surfaces polished with 2 chairside polishing kits had higher than conventional polishing and pumice polishing. The highest roughness value was $0.32{\pm}0.10{\mu}m$, and the lowest was $0.02{\pm}0.00{\mu}m$. The adhesion of $C.$ $albicans$ on the specimens polished with chairside polishing group and pumice polishing group were increased than conventional polishing group ($P$<.01). Conclusion: Conventional laboratory polishing was found to produce the smoothest surface and the lowest adhesion of $C.$ $albicans$. Two groups polished with Chairside polishing kits were similar with respect to surface roughness. Surface of the specimen polished with pumice is significantly smoother than 2 chairside polishing groups, but the result of $C.$ $albicans$ adhesion is that group polished with pumice was similar with 2 chairside polishing groups ($P$>.01).