Browse > Article
http://dx.doi.org/10.4047/jkap.2012.50.1.53

Study on the effect of soldering methods on the characteristics of the Ni-Cr alloy  

Kim, Chul-Hyung (Department of Prosthodontics, School of Dentistry, Dankook University)
Song, Young-Gyun (Department of Prosthodontics, School of Dentistry, Dankook University)
Lee, Jong-Hyuk (Department of Prosthodontics, School of Dentistry, Dankook University)
Publication Information
The Journal of Korean Academy of Prosthodontics / v.50, no.1, 2012 , pp. 53-60 More about this Journal
Abstract
Purpose: The purpose of this study was to compare Ni-Cr alloy property of gas-oxygen torch soldering and infrared welding using optical microscope and Electron Probe Micro Analyzer (EPMA). Materials and methods: Ni-Cr alloys were casted for specimens. Specimens had 3.0 mm diameter, 30.0 mm length and were divided into two groups. Each group had 4 specimens. One group was for gas-oxygen torch soldering and the other was infrared welding. Specimens were cut with low-speed disc and soldered each other with gas-oxygen torch and infrared machine. After soldering and polishing, specimens were observed at 3 points (soldering point, 5 mm distance point, 10 mm distance point) with optical microscope and analyzed 3 points (soldering point, 5 mm distance point, 10 mm distance point with EPMA. Results: The results of this study were as follows: 1. The observation of gas-oxygen torch soldering at 10 mm distance point under the optical microscope was not founded any specific surface properties, but some crack lines were observed at 5 mm distance and soldering point. 2. There were no crack lines were founded at the observation of infrared welding at 10 mm distance and 5 mm distance points under the optical microscope. However, at the 5 mm distance, the surface was not smooth enough compared with at 10 mm distance point. Some crack lines were observed at the welding point as well. 3. In the EPMA analysis of the gas-oxygen torch soldering, the component of Ni was increased by 4.5%, Cr was increased by 7.5% than that of the Ni-Cr alloy at the 10.0 mm distance. At the 5 mm distance, the component of Ni was decreased by 6.1%, Mo was increased by 9.0% than that of the Ni-Cr alloy but Cr was equally shown at the 5.0 mm distance. Only Ni was shown at the soldering point. 4. In the EPMA analysis of the infrared welding, the component of Ni was increased by 9.1%, Cr was increased by 0.4% than that of the Ni-Cr alloy but Al was equal at the 10.0 mm distance. At the 5 mm distance, the component of Ni was increased by 4.7%, Cr was increased by 4.7% and Al was increased by 0.1% than that of the Ni-Cr alloy. At the welding point, the component of Ni was increased by 8.8%, Cr was increased by 8.2% than that of the Ni-Cr alloy. Conclusion: From these results, at the 5 mm distance from the soldering point, the surface of the infrared welding was more smoother than that of the gas-oxygen torch soldering. On the EPMA analysis, the component of the specimens with infrared welding was more similar than that of the gas-oxygen torch soldering compared with the component of the Ni-Cr alloy.
Keywords
Gas-oxygen torch soldering; infrared welding; Optical microscope; EPMA;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Bellagamba RL. The effects of prewetting on postsoldering of base metal alloys. J Prosthet Dent 1985;54:355-358.   DOI   ScienceOn
2 Tambasco J, Anthony T, Sandven O. Laser welding in the dental laboratory: an alternative to soldering. J Dent Technol 1996; 13:23-31.
3 Townsend LW, Vermilyea SG, Griswold WH. Soldering nonnoble alloys. J Prosthet Dent 1983;50:51-53.   DOI   ScienceOn
4 Stade EH, Reisbick MH, Preston JD. Preceramic and postceramic solder joints. J Prosthet Dent 1975;34:527-532.   DOI   ScienceOn
5 Bernard C, Moon PC, Knap F. Strength of PFM solder connectors, with and without gold plating. J Dent Res 1982;61:245-248.
6 Sobieralski JA, Brukl CE, Smith NK. Tensile strengths and microscopic analysis of nickel-chromium base metal postceramic solder joints. J Prosthet Dent 1987;58:35-42.   DOI   ScienceOn
7 Cattaneo G, Wagnild G, Marshall G, Watanabe L. Comparison of tensile strength of solder joints by infrared and conventional torch technique. J Prosthet Dent 1992;68:33-37.   DOI   ScienceOn
8 Monday JJ, Asgar K. Tensile strength comparison of presoldered and postsoldered joints. J Prosthet Dent 1986;55:23-27.   DOI   ScienceOn
9 Tehini GE, Stein RS. Comparative analysis of two techniques for soldered connectors. J Prosthet Dent 1993;69:16-19.   DOI   ScienceOn
10 Lee SY, Lee JH. Effect of soldering techniques and gap distance on tensile strength of soldered Ni-Cr alloy joint. J Adv Prosthodont 2010;2:117-121.   DOI   ScienceOn
11 Chai T, Chou CK. Mechanical properties of laser-welded cast titanium joints under different conditions. J Prosthet Dent 1998; 79:477-483.   DOI   ScienceOn
12 Lancaster JF. Metallurgy of welding. 5th ed. London; Chapman and Hall; 1993.
13 Lorenzana RE, Staffanou RS, Marker VA, Okabe T. Strength properties of soldered joints for a gold-palladium alloy and a palladium alloy. J Prosthet Dent 1987;57:450-454.   DOI   ScienceOn
14 Bergman M. Combinations of gold alloys in soldered joints. Swed Dent J 1977;1:99-106.
15 Lanin VL. Infrared heating in the technology of soldering components in electronics. Surf Engineer Appl Electrochem 2007;43:381-386.   DOI   ScienceOn