• 제목/요약/키워드: slow-fast dynamics

검색결과 51건 처리시간 0.025초

The effect of typhoon translation speed and landfall angle on the maximum surge height along the coastline

  • Qian, Xiaojuan;Son, Sangyoung
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2021년도 학술발표회
    • /
    • pp.153-153
    • /
    • 2021
  • Storm Storm event is one of major issues in South Korea due to devastating damage at its landfall. A series of statistical study on the historical typhoon records consistently insist that the typhoon translation speed (TS) is on slowdown trend annually, and thus provides an urgent topic in assessing the extreme storm surge under future climate change. Even though TS has been regarded as a principal contributor in storm surge dynamics, only a few studies have considered its impact on the storm surge. The landfall angle (LA), another key physical factor of storm surge also needs to be further investigated along with TS. This study aims to elucidate the interaction mechanism among TS, LA, coastal geometry, and storm surge synthetically by performing a series of simulations on the idealized geometries using Delft3D FM. In the simulation, various typhoons are set up according to different combinations of TS and LA, while their trajectories are assumed to be straight with the constant wind speed and the central pressure. Then, typhoons are subjected to make landfall over a set of idealized geometries that have different depth profiles and layouts (i.e., open coasts or bays). The simulation results show that: (i) For the open coasts, the maximum surge height (MSH) increases with increasing TS. (ii) For the constant bed level, a typhoon normal to the coastline resulted in peak MSH due to the lowest effect of the coastal wave. (iii) For the continental shelf with different widths, the slow-moving typhoon will generate the peak MSH around a small LA as the shelf width becomes narrow. (iv) For the bay, MSH enlarges with the ratio of L/E (the length of main-bay axis /gate size) dropping, while the greatest MSH is at L/E=1. These findings suggest that a fast-moving typhoon perpendicular to the coastline over a broad continental shelf will likely generate the extreme storm surge hazard in the future, as well as the slow-moving typhoon will make an acute landfall over a narrow continental shelf.

  • PDF

입자 동역학 시뮬레이션과 선적분 볼륨 렌더링을 이용한 실시간 유체 애니메이션 (Real-time Fluid Animation using Particle Dynamics Simulation and Pre-integrated Volume Rendering)

  • 이정진;강문구;김동호;신영길
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제32권1호
    • /
    • pp.29-38
    • /
    • 2005
  • 유체 애니메이션은 물리적 시뮬레이션과 시각적 렌더링으로 구성된다. 물리적 시뮬레이션은 입자 동역학을 이용한 해석 방법과 나비어-스토크스(Navier-Stokes) 방정식을 이용한 연속체 유동해석 방법이 많이 사용된다. 입자 동역학을 이용한 시뮬레이션은 연산 속도는 빠르나 유체의 움직임이 경우에 따라 부자연스러우며, 나비어-스토크스 방정식을 이용한 방법은 적절한 조건 하에서 사실적인 유체의 움직임을 표현할 수 있으나 방대한 연산량과 계산의 복잡성으로 인하여 실시간 응용이 어렵다. 우수한 품질의 렌더링 영상은 주로 전역적 조명 방법을 사용하여 얻을 수 있는데, 이 역시 실시간 응용에 적합한 속도론 내기에는 부적합하다. 본 논문에서는 개선된 입자 동역학 시뮬레이션과 선적분 볼륨 렌더링을 이용한 고속유체 애니메이션 방법을 제안한다 레나드-존스(Lennard-Jones) 모턴을 이용한 입자동역학 해석기법을 이용하여 유체의 움직임을 고속으로 시뮬레이션 하였으며, 적은 수의 입자만으로도 충분한 유체의 부피를 표현할 수 있도록 연산효율을 개선하였다. 또한 실시간 렌더링을 위하여 적은 수의 슬라이스로도 우수한 품질의 영상을 빠르게 얻을 수 있는 선적분 볼륨 렌더링 방식을 사용하였다. 본 제안 방법을 사용하여 실시간 응용에 적절한 속도와 화질을 보여주는 유체 애니메이션이 가능하다.

Large-scale and small-scale self-excited torsional vibrations of homogeneous and sectional drill strings

  • Gulyayev, V.I.;Glushakova, O.V.
    • Interaction and multiscale mechanics
    • /
    • 제4권4호
    • /
    • pp.291-311
    • /
    • 2011
  • To simulate the self excited torsional vibrations of rotating drill strings (DSs) in vertical bore-holes, the nonlinear wave models of homogeneous and sectional torsional pendulums are formulated. The stated problem is shown to be of singularly perturbed type because the coefficient appearing before the second derivative of the constitutive nonlinear differential equation is small. The diapasons ${\omega}_b\leq{\omega}\leq{\omega}_l$ of angular velocity ${\omega}$ of the DS rotation are found, where the torsional auto-oscillations (of limit cycles) of the DS bit are generated. The variation of the limit cycle states, i.e. birth (${\omega}={\omega}_b$), evolution (${\omega}_b<{\omega}<{\omega}_l$) and loss (${\omega}={\omega}_l$), with the increase in angular velocity ${\omega}$ is analyzed. It is observed that firstly, at birth state of bifurcation of the limit cycle, the auto-oscillation generated proceeds in the regime of fast and slow motions (multiscale motion) with very small amplitude and it has a relaxation mode with nearly discontinuous angular velocities of elastic twisting. The vibration amplitude increases as ${\omega}$ increases, and then it decreases as ${\omega}$ approaches ${\omega}_l$. Sectional drill strings are also considered, and the conditions of the solution at the point of the upper and lower section joints are deduced. Besides, the peculiarities of the auto-oscillations of the sectional DSs are discussed.

특이섭동 모델역변환을 이용한 멀티콥터 위치제어 연구 (Multicopter Position Control using Singular Perturbation based Dynamic Model Inversion)

  • 최형식;정연득;이장호;유혁;이상종
    • 한국항공우주학회지
    • /
    • 제45권4호
    • /
    • pp.276-283
    • /
    • 2017
  • 본 논문은 4개의 로터를 가지는 쿼드콥터에 대한 비선형 운동모델을 구성하고, 특이섭동 기법을 이용한 모델 역변환 위치 제어기 설계 결과에 대해 나타낸다. 특이섭동 모델 역변환방식은 느린 동역학과 빠른 동역학을 시분할 기법(time scale separation)기법을 이용하여 각각 역변환 시키는 방법이다. 수립한 6자유도 비선형 운동모델 기반으로, 모델 역변환 제어기를 설계하고 시뮬레이션을 수행한 결과 정확한 위치 추종을 수행함을 확인하였다.

델타연산자 섭동방법에 의한 항공기 동력학의 연산시간 감소 (Reduction of Computing Time in Aircraft Control by Delta Operating Singular Perturbation Technique)

  • 심규홍;사완
    • 한국항공우주학회지
    • /
    • 제31권3호
    • /
    • pp.39-49
    • /
    • 2003
  • 본 논문에서는 먼저 델타연산자 접근법과 섭동기법을 소개하였다. 전자는 수치연산에 있어서 round-off error를 줄여주고 후자는 시스템을 빠른 종속시스템과 느린 종속시스템으로 분리하여 연산시간을 줄여준다. 항공기의 동력학은 종방향 혹은 횡방향 모두 장주기(Phugoid)와 단주기 운동을 동시에 보여준다. 여기서는 경비행기 Beaver의 횡방향 모델에 섬동기법과 델타접슨법을 적용하여 얻는 근사치 해를 정확한 해와 비교하였다. 그 겨로가 개루프 시스템의 경우는 단 한번의 iteration을 시행하여 얻은 근사치 해가 정확한 해와 일치했고, 페루프 시스템의 경우는 iteration없이도 근사치 값이 정확한 해와 일치하였다. 이로써 제안된 방법들의 적용이 항공기 동력학 및 제어에 있어서 매우 유효함이 검증되었다.

DEVELOPMENT OF MATDYMO(MULTI-AGENT FOR TRAFFIC SIMULATION WITH VEHICLE DYNAMICS MODEL) II: DEVELOPMENT OF VEHICLE AND DRIVER AGENT

  • Cho, K.Y.;Kwon, S.J.;Suh, M.W.
    • International Journal of Automotive Technology
    • /
    • 제7권2호
    • /
    • pp.145-154
    • /
    • 2006
  • In the companion paper, the composition and structure of the MATDYMO (Multi-Agent for Traffic Simulation with Vehicle Dynamic Model) were proposed. MATDYMO consists of the road management system, the vehicle motion control system, the driver management system, and the integration control system. Among these systems, the road management system and the integration control system were discussed In the companion paper. In this paper, the vehicle motion control system and the driver management system are discussed. The driver management system constructs the driver agent capable of having different driving styles ranging from slow and careful driving to fast and aggressive driving through the yielding index and passing index. According to these indices, the agents pass or yield their lane for other vehicles; the driver management system constructs the vehicle agents capable of representing the physical vehicle itself. A vehicle agent shows its behavior according to its dynamic characteristics. The vehicle agent contains the nonlinear subcomponents of engine, torque converter, automatic transmission, and wheels. The simulation is conducted for an interrupted flow model and its results are verified by comparison with the results from a commercial software, TRANSYT-7F. The interrupted flow model simulation is implemented for three cases. The first case analyzes the agents' behaviors in the interrupted flow model and it confirms that the agent's behavior could characterize the diversity of human behavior and vehicle well through every rule and communication frameworks. The second case analyzes the traffic signals changed at different intervals and as the acceleration rate changed. The third case analyzes the effects of the traffic signals and traffic volume. The results of these analyses showed that the change of the traffic state was closely related with the vehicle acceleration rate, traffic volume, and the traffic signal interval between intersections. These simulations confirmed that MATDYMO can represent the real traffic condition of the interrupted flow model. At the current stage of development, MATDYMO shows great promise and has significant implications on future traffic state forecasting research.

토석류 유동성 평가를 위한 링 전단시험장치 개발 및 활용 (Ring-shear Apparatus for Estimating the Mobility of Debris Flow and Its Application)

  • 정승원;;송영석
    • 대한토목학회논문집
    • /
    • 제33권1호
    • /
    • pp.181-194
    • /
    • 2013
  • 산사태는 토사, 거석, 유목 등 산사태 물질의 중력사면 이동현상이다. 산사태는 수리학적, 지형학적, 지반공학적 요인에 따라 다양한 흐름 및 퇴적특성을 보인다. 흐름특성은 아주 느리게 움직이는 산사태(활동, 이류 등)에서 아주 빠르게 움직이는 산사태(토석사태, 토석류 등)까지 다양하다. 이런 점에서 산사태 발생과 확산 메커니즘의 이해를 위해 전단변형률에 따른 전단강도특성에 대한 연구가 필요하다. 본 연구는 한국형 산사태에 적합한 링 전단시험장치의 개발과 활용성에 대한 것이다. 링 전단시험장치는 산사태 유형별 피해 및 영향성 평가에 사용되는 전단강도를 측정할 수 있으며, 전단속도에 따른 산사태의 유동성을 평가하기 위한 장치이다. 비배수 전단강도 측정용 링 전단시험장치는 기존에 개발된 링 전단시험기의 수정보완형으로 '포화-압밀-배수-전단' 순으로 시험조건을 자유롭게 조절할 수 있다. 링 전단상자내 흙 시료의 전단강도의 정확한 측정을 위해 미끄럼 방지, 밀폐성 및 회전성 향상 기능을 갖춘 시험장치이다. 링 전단시험장치는 모래와 자갈 시료에 대한 예비실험을 수행하였으며 기존 시험결과와 비교하여 신뢰할 만한 결과를 확인하였다. 회전속도 100 mm/sec 로 구속할 때 배수조건에 따른 일시적 액상화 현상으로 인한 강도저하 현상이 관측되며, 전단면에 따른 입자파쇄 현상이 뚜렷하게 나타났다. 마지막으로 토석류 유변학에 기초하여 링 전단시험장치를 이용한 산사태 유동성 평가기법을 제안하였다.

지방정부의 정책추진과 갈등관리 -남양주시 소각잔재매립장 입지선정 및 건설갈등 사례- (Policy Process and Conflict Management of Local Government -A Case of Namyangju City's Landfill Site Construction for Incineration Remnants-)

  • 강문희
    • 한국콘텐츠학회논문지
    • /
    • 제11권11호
    • /
    • pp.156-172
    • /
    • 2011
  • 본 연구는 오랜 기간 동안 난항을 거듭해왔던 한 사례를 통해 지방정부의 정책추진과정에서 갈등관리능력이 차지하는 중요성을 부각시켜보고자 하는 목적으로 시도되었다. 본 연구가 주목한 사례는 지난 1991년 입지선정에서 시작하여 무려 20년이란 긴 세월 동안 정책추진의 난항을 거듭해오다가 최근에 이르러서야 해결의 문턱을 넘어 비교적 안정적인 정책추진의 기미를 보이고 있는 경기도 남양주시의 쓰레기 소각잔재 매립장 건설사례다. 유사한 입지선정 및 건설과정의 갈등을 겪었음에도 불구하고 상대적으로 짧은 기간 내에 성공적인 정책추진을 경험했던 기타의 많은 지방정부 사례와 달리 남양주시 사례의 경우 장기간 동안 대립적 상황을 거듭해 왔던 점은 갈등관리의 차원에서 주목해 볼만한 특이사례다. 과연 남양주시는 왜 정책추진에 그토록 오랜 세월을 허비하며 난항을 거듭해 온 것일까? 본 연구는 일정한 분석모형에 입각하여 정책 성패요인의 인과관계를 검증하는 연역적 접근과는 달리, 정책단계별 사례의 개요와 쟁점 및 구조를 기술하는데 치중함으로써 정책단계별 갈등관리의 중요 요소를 귀납적으로 추론해 나가는 방식을 취했다. 분석 결과, 지방정부의 정책추진과정에서 갈등관리는 정책수립 및 결정단계와 홍보단계 그리고 집행단계에 이르기까지 지속적인 민주적 절차와 토론 및 주민과의 협력을 도출하기 위한 노력을 요하는 연속적 과정임을 확인할 수 있었으며, 이는 궁극적으로 정책성공의 중요한 요인으로 작용하고 있음을 확인하고 있다.

스크린설치높이·공기유입량 차이에 따른 벤로형 유리온실 미기상 CFD 유동해석 (CFD Analysis for Microclimate of Venlo Type Glasshouse with the Screen Height and Air-inflow Quantity)

  • 양원모
    • 생물환경조절학회지
    • /
    • 제29권1호
    • /
    • pp.52-61
    • /
    • 2020
  • 겨울철 벤로형 유리온실(W59×L68×H5.9m) 보온스크린 높이의 차이에 따른 실내온도 변화를 파악하기 위하여 00시부터 04시까지 30분 간격으로 열유동해석을 하였다. 초기에는 상대적으로 난방 외부접촉면적이 큰 보온스크린 설치높이 5.9m에서 보온스크린 설치높이 4.1m에 비해 온도감소가 빨라 낮은 온도를 나타냈으나 해석 2시간 이후부터는 상대적으로 온도감소가 느렸고 04시에는 0.6℃ 높았다. 그러나 해석시작1시간 후 실내온도가 약13℃까지 내려가고, 그 이전에 난방기가 작동해야 된다고 볼 때, 해석 2시간 동안 온도감소가 상대적으로 느렸던 보온스크린 설치높이 4.1m에서 5.1m에 비해 난방에너지 절감에 유리할 것으로 판단되었다. 토마토가 자라는 지면 2m 높이에서의 유동은 보온스크린 설치높이 5.9m에서 4.1m에 비해 상대적으로 넓고 빨랐으며 유동해석 1시간 후인 01시의 평균차이는 0.034m·s-1였다. 여름철 차광스크린 설치높이를 5.7m와 3.9m로 달리하되70%닫힘 조건에서 12시부터 13시까지는 온실하부덕트 외부공기유입량 0.67㎥·s-1 상태 그 후부터는 외부 유입공기를 3배로 증가하여 냉방효과를 비교하였다. 초기 12시부터 13시까지는 차광스크린 70%닫힘 상태에서 무차광에 비해 오히려 평균 약0.9℃ 높았지만 외부공기유입량이 증가하는 13시 이후 부터는 차광스크린 70%닫힘 조건에서 온도가 감소하였고 14시 30분에는 무차광에 비해 0.5℃ 낮았다. 차광스크린 70% 닫힘 조건에서 바닥면의 온도분포는 스크린 설치높이와 개방 정도에 비례하여 낮았으며 무차광에 비해 8℃이상 낮았다. 온실 내 상대습도는 차광스크린을 30% 개방하는 조건에서는 차광스크린의 높이나 개방정도에 따른 차이가 미미하였다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF