• Title/Summary/Keyword: skin-patch test

Search Result 83, Processing Time 0.173 seconds

Improvement of Skin Photoaging by Polysaccharide Extract Derived from Tremella fuciformis (White Jelly Mushroom)

  • Choi, Jae-Hwan;Kim, Bora
    • Natural Product Sciences
    • /
    • v.27 no.4
    • /
    • pp.300-306
    • /
    • 2021
  • Chronic ultraviolet (UV) radiation causes photoaging, which represents skin damage, disrupts skin barrier function, and promotes wrinkle formation. We investigated that the polysaccharide extract of an edible basidiomycetous white jelly mushroom, Tremella fuciformis, (TF-Glucan®) exhibited statistically photoprotective activity by inhibiting matrix metalloproteases (MMPs) and increasing collagen synthesis, and an anti-inflammatory activity by inhibiting nitric oxide and pro-inflammatory cytokines at the concentrations of less than 1000 ㎍/ml, which is not cytotoxic (p < 0.05). Additionally, TF-Glucan® increased the expression of involucrin and filaggrin to prevent the disruption of UVB-induced barrier function (p < 0.05). TF-Glucan® was assessed as a safe material by the human primary skin irritation (1, 3, 5%), human repeated insult patch test (no sensitization at 5%), 3T3 NRU phototoxicity assay (no phototoxicity, PIF < 2, MPE < 0.1), eye irritation test test by BCOP (no category, IVIS ≤ 3) and local lymph node assay (negative at 10, 25, 50%) for identifying potential skin sensitizing. These results suggest that TF-Glucan® may be useful as an anti-photoaging ingredient for developing cosmeceuticals.

lontophoretic Delivery of Prostaglandin $E_1$ (이온토포레시스를 이용한 프로스타글란딘 $E_1$의 경피흡수)

  • Shin, Dong-Suk;Oh, Seaung-Youl
    • Journal of Pharmaceutical Investigation
    • /
    • v.29 no.2
    • /
    • pp.111-115
    • /
    • 1999
  • We have studied the transdermal flux of prostaglandin $E_1$ $(PGE_1)$ from a hydrogel patch through hairless mouse skin, to test the possibility of developing a transdermal delivery system. Karaya gum patch containing $PGE_1$ was prepared by casting method. $PGE_1$ was stable in the patch for 10 weeks. The effect of current application, enhancer (propylene glycol monolaurate : PGML), adhesive and patch thickness on the flux was studied using side-by-side diffusion cell. Passive flux of $PGE_1$ was negligible. Cathodal delivery increased the flux about 20 fold. As the concentrations of PGML increased, flux increased. When 5% PGML was used as the enhancer, maximum flux by cathodal iontophoresis was $55\;{\mu}g/cm^2\;hr$. It increased about 2 folds to $100\;{\mu}g/cm^2\;hr$, when the amount of PGML used was 9%. Large increase in flux and the decrease in time to reach maximum flux were observed when the skin was pretreated with neat PGML (maximum flux obtained was about $200\;{\mu}g/cm^2\;hr$). Use of adhesive decreased the flux significantly. To the contrary of our expectation, increase in current density decreased the flux. These flux data together with the stability data indicate that, though the onset of sufficient delivery occur after 1-2 hours of application, therapeutic amount of $PGE_1$ can be delivered through skin using iontophoresis and penetration enhancer.

  • PDF

Evaluation of Hypersensitivity Reaction to Dental Materials with a Patch Test (첩포시험을 이용한 치과용 재료의 알러지 평가)

  • Jeon, Hee-Sun;Park, June-Sang;Ko, Myung-Yun
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.2
    • /
    • pp.167-172
    • /
    • 2000
  • Both immune reaction and hypersensitivity reaction are occurred by the same mechanism, the antigen and antibody reaction. The favorable result of this reaction towards a host is called clinically an immune reaction and the opposite results is called an hypersensitivity reaction. Type IV hypersensitivity reaction is a delayed type which is related to the cellular immune reaction and a contact hypersensitivity is included in this type. Various dental materials such as metal (mercury, nickel, chrome, cobalt), resin and eugenol are etiologic substances. Patch test kit is composed of test substance with a controlled concentration which respond only to a susceptible patient and an aluminum chamber, and etiologic substances for hypersensitivity can be easily and comfortably found just by applying the kit to the patient's skin. In this case report, the patch test was performed to a patients with oral lichen planus and the allergen, restorative material was found. After removal of the matching restoration from the patient's mouth, the symptom was improved.

  • PDF

Rheological Behaviour of Emulsions Containing Polyacrylamide (폴리아크릴아마이드를 함유한 에멀젼의 유변학적 거동)

  • Cho, Wan-Goo;Kim, Song-E
    • Journal of the Korean Applied Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.99-106
    • /
    • 2010
  • We have investigated the rheological behaviours of emulsions containing polymers. The polymers used in this study were polyacrylamide and carboxy vinyl polymer. The emulsion with polyacrylamide shows better prior preference than that with carboxy vinyl polymer on the skin texture. In the toxicity test, such as, LLNA cell toxicity, skin organ culture and human patch test, polyacrylamide was the appropriate materials for the cosmetics. The viscosity of polyacrylamide shows maximum value in neutral pH and good stability against temperature. The decreasing effect of viscosity against salt was not good enough but showed a better result than that of carboxy vinyl polymer. Two times the amount of polyacrylamide should be used for the formation of a similar viscosity of carboxy vinyl polymer. Yield value of polyacrylamide was low and the effect for the stabilizing emulsions was also low.

Late adverse reactions to iopromide (Ultravist®) diagnosed by the patch test: a case report (첩포검사로 진단된 Iopromide (Ultravist®)의 지연성 부작용 1예)

  • Lee, Soon Joo;Yang, Eun Mi;Choi, Woo Yeon;Song, Eun Song;Han, Dong Kyun;Cho, Young Kuk;Ma, Jae Sook
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.4
    • /
    • pp.499-503
    • /
    • 2009
  • Iodinated contrast media (CM) can cause immediate and late reactions. We treated a patient with a recurrent generalized maculopapular rash and a fever that occurred within two days of exposure to iodinated CM, iopromide ($Ultravist^{(R)}$), for chest computed tomography. We performed skin testing including prick tests, intradermal tests, and patch tests. Our findings indicated a late skin reaction to $Ultravist^{(R)}$in addition to cross-reactions to other iodinated CM such as ioversol ($Optiray^{(R)}$), iohexol ($Iobrix^{(R)}$), and iobitridol ($Xenetix^{(R)}$). In this study, we report the case of a patient diagnosed with a late adverse reaction to $Ultravist^{(R)}$in addition to cross-reactions to other iodinated CM.

Use of Oil Red O Staining Method in Non-Comedogenic Test for Cosmetics (화장품의 면포 비유발 평가에서 오일 레드 오 염색법의 응용)

  • Lee, Sun Hwa;Lee, Jung Im;Kim, Yoo-Ri;Lee, Bum Chun;Kang, Min Ji;Choi, Kwang Seong;Moon, Tae Kee
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.39 no.3
    • /
    • pp.215-224
    • /
    • 2013
  • It has been reported that certain ingredients added to cosmetics clog the skin pores and this can cause outbreaks of comedones which are the primary sign of acne leading to inflammatory acne. This research aims to establish objective evaluation criteria for non-comedogenic cosmetics suitable for acne prone skin. The research has been carried out to examine non-comedogenic test performed in foreign clinical institutions and to establish the evaluation method for detecting comedones outbreaks through repetitive closed back-patch test, Also, usability evaluation on face skin is performed additionally to the same subjects. The analysis of the comedones collected through repetitive closed back-patch test confirmed that the test products, moisturizer and sunscreen product, did not cause comedones. These results had no correlation with the analysis result of the comedones collected from face skin or visual evaluation of acne by Global Acne Grading System (GAGS) in face usability test. Additionally, Oil red O staining was performed on the collected comedones specimen for easy distinction of comedones from hair follicle in image analysis. The analysis result of stained specimen showed higher precision than that of non-stained specimen. This study established a new version of non-comedogenic test for cosmetics, whose objectivity and reliability were improved by inclusion of comedones staining step.

Antioxidant Activity and Cytotoxicity on cell of Arctium lappa L. root extract (우엉 뿌리 추출물의 항산화 활성 및 세포 독성 평가)

  • Moon, Ji-sun;Lee, Jin-Hee;You, Seon-hee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.41-49
    • /
    • 2017
  • In this study, to evaluate antioxidant activity and safety on skin of Arctium lappa L. root extract, antioxidant activity was understood through total content of polyphenol, total content of flavonoid and DPPH radical scavenging activity, and cytotoxicity for B16F10 melanoma and skin cell protection effect for ultraviolet rays A were confirmed. To verify the application as cosmetic material, the first skin patch test was performed. The result of this experiment showed that as the content of Arctium lappa L. root extract increased, the content of polyphenol and flavonoid increased, and DPPH radical scavenging activity was confirmed. The result of checking cytotoxicity for B16F10 melanoma cells showed that it had low toxicity, and over 80% cell protection effect for ultraviolet rays A was confirmed. In addition, through the first skin patch test, Arctium lappa L. root extract was confirmed to have almost no skin irritation. Through this result, Arctium lappa L. root extract is excellent in skin protection from ultraviolet rays, has low toxicity for skin cells and is safe on skin, so its possibility of being a cosmetic ingredient was verified.

Synthesis and Biocompatibility Study of Hydrogel for Patch Sensor in Non-invasive Glucose Monitoring System (무채혈 혈당 측정시스템의 Patch Sensor용 수화젤의 합성 및 생체적합성에 관한 연구)

  • Kwon, Jeong-Woo;Kim, Dong-Chul;Yoon, In-Joon;Jeong, Yoon-Na;Jeong, Ji-Young;Hwang, In-Sik
    • Polymer(Korea)
    • /
    • v.33 no.2
    • /
    • pp.111-117
    • /
    • 2009
  • This study aims to verify for humans the suitability of the enzyme-fixed hydrogel used for the patch sensor of the blood sugar testing system without blood sampling, which utilizes reverse iontophoresis. Using acrylate monomers, hydrogel was synthesized to which a certain unit of enzyme is fixed. In order to analyze the material property of the synthesized hydrogel, a structural analysis was performed using FT-IR spectroscopy, while the DSC was used to verify the thermal stability. In addition, with the UV-Vis spectrophotometer, it was verified that the degree of active enzyme is at least 50% greater than the standard product. The SEM was used to verify secure fixation of the enzyme onto the surface. As a result, it was observed that the enzyme is successfully fixed to the surface. Since the hydrogel makes direct contact with a patient's skin, it is essential to evaluate the toxicity when making direct contact with the skin. For that purpose, various sets of tests were undertaken according to the ISO 10993-cytotoxicity, intracutaneous reactivity, skin irritation test and maximization sensitization. Consequently, it was successfully verified that the enzyme-fixed hydrogel have bioavailability.

A Safety Test on Grapefruit Seed Extract (Grapefruit 종자추출물의 안전성 검사)

  • 조성환;고경혁;이근희
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.24 no.5
    • /
    • pp.690-694
    • /
    • 1995
  • Effects of grapefruit seed extract on the lethality, the primary skin irritation, and the acute eye irritation potentials were evaluated in rats. The acute oral $LD_{50}$ of GFSE for Sprague-Dawley derived rats was 3.75g/kg with 95% confidence limits of 2.55 and 5.52g/kg. Patch application to the intact and abraded skin of rabbits led to mild to moderate erythema and no or mild edema. Application to the eyes of rabbits led to severe corneal opacity, iritis, conjunctival erythema, edema, and discharge.

  • PDF

Effect of Lecithin on Dermal Safety of Nanoemulsion Prepared from Hydrogenated Lecithin and Silicone Oil

  • Bae, Duck-Hwan;Shin, Jae-Sup;Shin, Gwi-Su;Jin, Fan-Long;Park, Soo-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.4
    • /
    • pp.821-824
    • /
    • 2009
  • In this study, a hydrogenated lecithin-containing nanoemulsion was prepared from hydrogenated lecithin and silicone oil. Tween-60 and liquid paraffin, widely known emulsifiers, were used as standard substances, and high shear was produced by utilizing a high shear homogenizer and microfluidizer. The properties of the nanoemulsion prepared with hydrogenated lecithin were evaluated by measuring interfacial tension, dynamic interfacial tension, droplet size, zeta-potential, friction force, skin surface hygrometery, and dermal safety. The interfacial tension of lecinol S10/silicone oil was lower than that of lecinol S10/liquid paraffin. The nanoemulsion prepared from hydrogenated lecithin shows lower zeta-potential, skin surface hygrometery, and friction force compared with a general emulsion. The silicone nanoemulsion prepared from hydrogenated lecithin showed a zero value in the patch test and thus exhibits high dermal safety.