• Title/Summary/Keyword: simple and R-simple

Search Result 2,180, Processing Time 0.036 seconds

A Comparitive Study of MAUT and AHP in Priority Setting of R&B Projects (연구개발사업 우선순위 설정에 있어서 다속성효용이론(MAUT)과 계층분석과정(AHP)의 비교)

  • 박주형;김정흠
    • Journal of Korea Technology Innovation Society
    • /
    • v.2 no.2
    • /
    • pp.201-218
    • /
    • 1999
  • The article contains an introduction of possibility of applying Multi-Attribute Utility Theory(MAUT) for priority setting of R&D projects. MAUT is compared with AHP, which is widely used recently. These two techuiques are applied to set priorities of R&D projects In a Government-funded Research Institute. Six criteria are chosen from consultation with decision makers. They are composed of 1) validity as representative projects, 2) possibility of resource mobilization, 3) spillover effect of developed technologies, 4) possibility of success, 5) scope of participation and 6) clarity of research goal. To set priorities of R&D projects, SMART(Simple MultiAttribute Rating Technique) and DVM(Difference Value Measurement) out of many MAUT methods are used to design the utility function and to determine the weights among criteria. The aggregation model is additive on the assumption the criteria are independent. AHP executes pairwise comparisons for criteria and alternatives. From the results of the case study, the results and theoretical characteristics are compared.

  • PDF

Evaluation of Flow Stress of Metal up to High Strain (금속소재의 고변형률 영역 유동응력선도 평가)

  • Lee, S.K.;Lee, I.K.;Lee, S.Y.;Lee, S.M.;Jeong, M.S.
    • Transactions of Materials Processing
    • /
    • v.29 no.6
    • /
    • pp.316-322
    • /
    • 2020
  • The flow stress curve is usually determined via uniaxial tensile or simple compression test. However, the flow stress curve up to high strain cannot be obtained using these two tests. This study presents a simple method for obtaining the flow stress curve up to high strain via FE analysis, a simple compression test, and an indentation test. In order to draw the flow stress curve up to high strain, the indentation test was carried out with the pre-stained specimen using the simple compression test. The flow stress curve of Al6110 was evaluated up to high strain using the proposed method, and the result was compared with the flow stress curve of the uniaxial tensile test of the initial material.

Development of Quality of Life Measurement for Cancer Patients (암환자의 삶의 질 도구개발)

  • Tae, Young Sook;Kang, Eun-Sil;Lee, Myung Hwa;Park, Geum Ja
    • Korean Journal of Adult Nursing
    • /
    • v.12 no.4
    • /
    • pp.741-757
    • /
    • 2000
  • This study was undertaken to develop an instrument to be used for measuring the concept of quality of life of Korean patients with cancer multidimensionary and correctly. It can contribute in holistic nursing care for Korean cancer patients and also provide and validate basic data to help oncology nurses measure the outcome of nursing intervention correctly. To develop this instrument, the researchers first estabilished a conceptual framework based on the results of qualitative data analysis and indepth interview method Development of the scale was conducted using a method in which 31 items were assessed by subjects' self report using linear analogue scales. The subjects were 79 D.M. patients, 103 patients with acute illness, and 91 cancer patients residing in Busan, Korea. Data were collected during the period from July, 24 to August 14, 2000. This instrument consisted of 31 items with a self report scale. This instrument covered 4 dimensions of cancer patients : 1) physical wellbeing 2) psychological wellbeing 3) social wellbeing and 4)spiritual wellbeing. Each item had a possible score of 10. The reliability of the scale was tested with Cronbach's alpha. Validity was evaluated by examining the relationships of this scale, Youn's Quality of Life Questionnare scores and the Simple Quality of Life scale. Two separate runs of multiple regression were used to predict scores on the Simple Quality of Life measurement. Further validation was obtained by examining the correlation between the instrument subscores and Youn's Quality of Life measurement subscore for convergence of this scale. Examination of the discriminant. power of the instrument was done using ANOVA test. The results are summarized as follows: 1. The reliability of the instrument for the quality of life was 0.8321(Cronbach's alpha.), physical wellbeing dimension 0.6343, psychological wellbeing dimension 0.6501, spiritual wellbeing dimension 0.5883. 2. This instrument had a high correlation with Youn's Quality of Life measurement(r= 0.636) in cancer patients, whereas it had a low correlation with Simple Quality of Life measurement(r=0.455) in cancer patients. In the D.M. patients, the instrument correlated with both the Youn's Quality of Life measurement and Simple Quality of life measurement(r=0.313, r= 0.407) and in the acute stage patients, the instrument had no correlation. 3. Multiple regression of individual items on the Simple Quality of Life scores accounted for 56.8% of the variance in the Simple Quality of Life measurement, whereas, Youn's Quality of Life measurement scores accounts for 31.7%. 4. The correlations collected from the three group had the same patterns of variations but especially the instrument developed in this study had higher disciminant power than that of Youn's Quality of Life Measurement.

  • PDF

Development of the 120kV/70A High Voltage Switching Circuit with MOSFETs Operated by Simple Gate Drive Unit (120kV/70A MOSFETs Switch의 구동회로 개발)

  • Song In Ho;Shin H. S.;Choi C. H.
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.707-710
    • /
    • 2002
  • A 120kV/70A high voltage switch has been installed at Korea Atomic Energy Research Institute in Taejon to supply power with Korea Superconducting Tokamak Advanced Research (KSTAR) Neutral Beam Injection (NBI) system. NBI system requires fast cutoff of the power supply voltage for protection of the grid when arc detected and fast turn-on the voltage for sustaining the beam current. Therefore the high voltage switch and arc current detection circuit are important part of the NBI power supply and there are much need for high voltage solid state switches in NBI system and a broad area of applications. This switch consisted of 100 series connected MOSFETs and adopted the proposed simple and reliable gate drive circuit without bias supply, Various results taken during the commissioning phase with a 100kW resistive load and NBI source are shown. This paper presents the detailed design of 120kV/70A high voltage MOSFETs switch and simple gate drive circuit. Problems with the high voltage switch and gate driver and solutions are also presented.

  • PDF

ON SOME GENERALIZATIONS OF CLOSED SUBMODULES

  • DURGUN, YILMAZ
    • Bulletin of the Korean Mathematical Society
    • /
    • v.52 no.5
    • /
    • pp.1549-1557
    • /
    • 2015
  • Characterizations of closed subgroups in abelian groups have been generalized to modules in essentially dierent ways; they are in general inequivalent. Here we consider the relations between these generalizations over commutative rings, and we characterize the commutative rings over which they coincide. These are exactly the commutative noetherian distributive rings. We also give a characterization of c-injective modules over commutative noetherian distributive rings. For a noetherian distributive ring R, we prove that, (1) direct product of simple R-modules is c-injective; (2) an R-module D is c-injective if and only if it is isomorphic to a direct summand of a direct product of simple R-modules and injective R-modules.

A simple and sensitive assay for chitinolytic activity of the recombinant CHT1 proteins from the hard tick H. longicornis using ethylene glycol chitin (Ethylene glycol chitin을 이용한 진드기 H. longicornis 재조합 CHT1 단백의 키틴분해능 검정 연구)

  • You, Myung-Jo;Fujisaki, Kozo
    • Korean Journal of Veterinary Research
    • /
    • v.43 no.1
    • /
    • pp.145-150
    • /
    • 2003
  • To determine effectively the chitinolytic activity of rCHT1 from the hard tick H. longicornis expressed in baculovirus-mediated Spodoptera frugtperda (Sf) 9 cells, a simple and sensitive assay system was established in solid phase using agarose gel containing ethylene glycol chitin as substrate. The various factors affecting the efficacy of the assay were also investigated. The effects of various temperature, dosages of proteins, pH of media and time courses of reaction were examined to verify the sensitivity of assay for chitinolytic activity of rCHT1 protein. It was found that the optimal reactive conditions were $37^{\circ}C$ of temperature, 12 to 15 hours of reactive times, $0.1{\mu}g$ of protein concentration and pH 5 to 7 of media. Using the assay system designed, the functional activities of H. longicornis rCHT1l protein could be evaluated simply and sensitively.

Generalized Divisibility Rule of Natural Number m (자연수 m의 일반화된 배수 판정법)

  • Lee, Sang-Un
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.87-93
    • /
    • 2014
  • For n/m=qm+r, there is no simple divisibility rule for simple m=7 such that is the n multiply by m? This problem can be more complex for two or more digits of m. The Dunkels method has been known for generalized divisibility test method, but this method can not compute very large digits number that can not processed by computer. This paper suggests simple and exact divisibility method for m completely irrelevant n and m of digits. The proposed method sets $r_1=n_1n_2{\cdots}n_l(mod m)$ for $n=n_1n_2n_3{\cdots}n_k$, $m=m_1m_2{\cdots}m_l$. Then this method computes $r_i=r_{i-1}{\times}10+n_i(mod m)$, $i=2,3,{\cdots}k-l+1$ and reduces the digits of n one-by-one. The proposed method can be get the quotient and remainder with easy, fast and correct for various n,m experimental data.

GENERATING PAIRS FOR THE HELD GROUP He

  • Ashrafi, Ali-Reza
    • Journal of applied mathematics & informatics
    • /
    • v.10 no.1_2
    • /
    • pp.167-174
    • /
    • 2002
  • A group G is said to be (l, n, n)-generated if it is a quotient group of the triangle group T(p,q,r)=(x,y,z|x$\^$p/=y$\^$q/=z$\^$r/=xyz=1). In [15], the question of finding all triples (l, m, n) such that non-abelian finite simple groups are (l , m, n)-generated was posed. In this paper we partially answer this question for the sporadic group He. We continue the study of (p, q, r) -generations of the sporadic simple groups, where p, q, r are distinct primes. The problem is resolved for the Held group He.

Time-dependent stresses and curvatures in cracked R.C. sections under working loads

  • Al-Zaid, Rajeh Z.
    • Structural Engineering and Mechanics
    • /
    • v.18 no.3
    • /
    • pp.363-376
    • /
    • 2004
  • The present study provides a relatively simple and accurate analytical model for the prediction of time-dependent stresses and curvatures of cracked R.C. sections under working loads. A more simplified solution is also provided. The proposed models are demonstrated by considering a numerical example and conducting a parametric study on the effects of relevant R.C. design parameters. In contrary to tension reinforcement, the compression reinforcement is found to contribute significantly in reducing tensile stresses in tension steel and in reducing the total section curvatures. The good accuracy of the proposed approximate solution opens a new vision towards a simple yet accurate model for the prediction of time-dependent effects in R.C. structures.

MININJECTIVE RINGS AND QUASI FROBENIUS RINGS

  • Min, Kang Joo
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.13 no.2
    • /
    • pp.9-17
    • /
    • 2001
  • A ring R is called right mininjective if every isomorphsim between simple right ideals is given by left multiplication by an element of R. In this paper we consider that the necessary and sufficient condition for that Trivial extension of R by V, i.e. T(R; V ) is mininjective. We also study the split null extension R and S by V.

  • PDF