• Title/Summary/Keyword: signal measurement

Search Result 3,137, Processing Time 0.028 seconds

Comparison of Human Responses to Transportation Noise in Monaural and Binaural Hearing, Part I: Measurement and Analysis (교통소음의 모노럴과 바이노럴 청감 비교 연구 I: 측정 및 분석)

  • Kim, Jaehwan;Lim, Chang-Woo;Jeong, Wontae;Hong, Jiyoung;Cheung, Wansup;Lee, Soogab
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1268-1278
    • /
    • 2004
  • Measurement of noise is not only to know the information of acoustic pressure but to assess human response to noise. To find human response to transportation noise through the laboratory study we have to measure and reproduce noise. The method of noise reproduction is largely divided into monaural and binaural techniques. But human fundamentally hears sound through both ears, referred as binaural hearing. Binaural signal is different from monaural signal because it includes more information of physical phenomena like acoustical reflection, diffraction and refraction. Especially head and pinna play an important role in perceiving change of signal origin. So, the amplitude of binaural signal is higher than that of monaural signal and spectrum of both signals is discriminated. Most of assessment and regulation of transportation noise are, however, based on monaural measurement techniques. The quantitative difference between monaural and binaural measurement is investigated in this study. Comparison on several transportation noisesshows defect of information in monaural measurements.

Measurement Accuracy of Oscillation-Based Test of Analog-to-Digital Converters

  • Mrak, Peter;Biasizzo, Anton;Novak, Franc
    • ETRI Journal
    • /
    • v.32 no.1
    • /
    • pp.154-156
    • /
    • 2010
  • Oscillation-based testing of analog-to-digital converters represents a viable option for low-cost built-in self-testing in mixed-signal design. While numerous papers have addressed implementation issues, little attention has been paid to the measurement accuracy. In this letter, we highlight an inherent measurement uncertainty which has to be considered when deriving the parameters from the oscillation frequency.

Implementation of Extended Kalman Filter for Real-Time Noncontact ECG Signal Acquisition in Android-Based Mobile Monitoring System

  • Rachim, Vega Pradana;Kang, Sung-Chul;Chung, Wan-Young;Kwon, Tae-Ha
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.7-14
    • /
    • 2014
  • Noncontact electrocardiogram (ECG) measurement using capacitive-coupled technique is a very reliable long-term noninvasive health-care remote monitoring system. It can be used continuously without interrupting the daily activities of the user and is one of the most promising developments in health-care technology. However, ECG signal is a very small electric signal. A robust system is needed to separate the clean ECG signal from noise in the measurement environment. Noise may come from many sources around the system, for example, bad contact between the sensor and body, common-mode electrical noise, movement artifacts, and triboelectric effect. Thus, in this paper, the extended Kalman filter (EKF) is applied to denoise a real-time ECG signal in capacitive-coupled sensors. The ECG signal becomes highly stable and noise-free by combining the common analog signal processing and the digital EKF in the processing step. Furthermore, to achieve ubiquitous monitoring, android-based application is developed to process the heart rate in a realtime ECG measurement.

Effect of satellite link noise for satellite range measurement using tone method (Tone 방식을 사용한 위성 거리 측정에 대한 위성 링크 잡음의 영향)

  • Kim Young Wan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.2 s.332
    • /
    • pp.9-16
    • /
    • 2005
  • The performance of satellite range measurement using tone method was analyzed in the presence of satellite link AWGN. The phase errors in range measurement are generated by AWGN of satellite up- and down-link and the degradations of satellite range measurement are dependent on the transmission mode and loop bandwidth of satellite measurement system. The analyzed effects for satellite measurement in presence of satellite link noise were also analyzed with the measured satellite range data via satellite range measurement system operating in satellite link AWGN. In RAU mode, the satellite range differences of 14.4 to 40.6 m were occurred according to the loop bandwidth of satellite range measurement system and the degradation of 0.3 dB compared with theoretical value was generated under condition of the signal-to-noise ratio of 43 dB. In RAU and TM mode, the performances of range measurement were approximately agreed to the that of RAU mode. In order to get the equal performance characteristics with RAU mode, the signal-to-noise ratio of satellite link for RAU and TM mode should be increased by signal power of 2.3 dB, which is a power loss due to transmission of telemetry signal.

Realization of High Precision Position Measurement System Using M-sequence Encoded Laser Beam Scanning

  • Takayama, Jun-ya;Shinji Ohyama;Akira Kobayashi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.107.5-107
    • /
    • 2001
  • In this report, as the active position measurement system, a new method for two-dimensional position measurement system using a concept of semi-open type signal field has proposed. The feature of this system is realizing a position measurement only by scanning the encoded laser beams from scanning points to a measurement field, and observed it. First, both system configuration and encoding method are considered concretely, and M-sequence signal is selected for encoding. Next system design is performed to realize the theoretical measurement accuracy, and applied to a position measurement experiments. Experimental results show that measurement precision is larger than theoretical values. Furthermore, method for improving the measurement ...

  • PDF

A Study on HMI Assessment of Joystick Driving System Using the Physiological Signal Measurement Method (생리신호 측정기법을 이용한 Joystick 운전방식의 HMI 평가연구)

  • Kim, Bae-Young;Koo, Tae-Yun;Bae, Chul-Ho;Park, Jung-Hoon;Suh, Myung-Won
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.3
    • /
    • pp.1-7
    • /
    • 2010
  • Recently, the vehicle driving device has been designed for driver's convenience. Especially, the automobile industry develops the vehicle using the joystick instead of steering wheel from the concept car. The biggest strength of using the joystick is that the driver feels less workload and fatigue than when the driver uses steering wheel. However, this kind of study still needs more research and experiments for more accurate result. Therefore, this research evaluated workload according to the driving device by the survey and the measurement of physiological signal. The reason not only using the survey also using the measurement of physiological signal is to support the result of the survey which is not enough to bring the accurate result. There were tow different kinds of methods to carry out this research; SWAT (Subjective Workload Assessment Technique) for the survey and the biopac equipment for the measurement of physiological signal. Furthermore, previously established driving simulator, GPS (Global Positioning System), and Seoul-Cheonan virtual expressway DB were used for the experiment. As the result of the experiment with 13 subjects, it was certain that using joystick device brings less workload and fatigue to the drivers than using steering wheel following both methods-the survey and the measurement of physiological signal. Also, it confirmed the significant result from the SPSS (Statistical Package for the Social Sciences) statistics analysis program.

Impedance Measurement and Matching Technique for Medium-Voltage Powerline Communication (고압전력선 통신을 위한 임피던스 측정 및 정합 방안 연구)

  • 이재조;유정훈;홍충선;이대영
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.5
    • /
    • pp.345-352
    • /
    • 2004
  • Currently, high data rate PLC(Power Line Communications), up to 100 Mbps, which use frequency bandwidth between 2 MHz and 30 MHz is investigated very hard, and commercial PLC modem for low voltage powerline network (indoor) is coming soon into communication market. For the purpose of developing a fit communication system which has little distortion of signal and attenuation, it is surely necessary to know about channel environments of powerline. Especially, the impedance measurement of the powerline and impedance matching are very important. As is known, since medium-voltage powerline (22.9 ㎸) is still working, it is not so simple to measure the powerline impedance. In our study, a portable impedance measurement equipment is developed. It consists of coupling capacitor, a drain coil and impedance matching transformer. The equipment is easily connected to medium voltage line and impedance of power line is measured using a network analyzer. Also, measurement results are used for impedance matching of PLC signal. In fact, matching transformer with several different impedances are used. The matching transformer is connected between coupling capacitor and signal port. In this paper, the developed portable impedance measurement equipment and impedance measurement results are presented. Also impedance matching technique using matching transformers will be explained. We showed the result of the improved performance by the impedance matching.

Measurement of the Flying Characteristics of HDD Slider Air Bearing Using AE Signal (AE 신호를 이용한 HDD 슬라이더 공기베어링의 부상상태 측정)

  • Kim, Jae-Jic;Jeong, Tae-Gun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.9
    • /
    • pp.1391-1399
    • /
    • 2001
  • The AE measurement is one of the most convenient methods for detecting contacts between the slider and the disk. The AE method has been widely used in the investigation of the tribology of sliding interfaces due to its convenience. We examined the relationship between the AE signal and the flying height of a slider. We investigated the influence of the disk linear velocity on the AE rms signal by using the AE measurement system. The experiment also gives the relationship between the take-off velocity and the disk surface conditions. To investigate the behavior of the slider further, the variances of the AE signals are analyzed. The experimental results indicate that the increase in the magnitude of the AE rms signal does not necessarily mean the slider/disk contacts.

Measured Intensity Control Method of a Phase-shift Measurement Based Laser Scanner by using APD Bias Voltage Characteristic (위상 검출 방식 레이저 스캐너의 APD bias 전압 특성을 이용한 검출신호세기 제어 방법)

  • Jang, Jun-Hwan;Yoon, Hee-Sun;Hwang, Sung-Ui;Park, Kyi-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.10
    • /
    • pp.1096-1100
    • /
    • 2012
  • In the phase-shift measurement method, the distance light travels can be obtained based on the phase difference between the reference signal and the measured signal. When the object having various colors is measured, the intensity of the measured signal much varies even at the same distance, and it causes different phase delay due to wide dynamic range input to a signal processing circuit. In this work, an measured intensity control method is proposed to solve this phase delay problem.

Biological Signal Measurement, Archiving, and Communication System (SiMACS) (생체신호 측정 및 종합관리 시스템 (SiMACS))

  • Woo, Eung-Je;Park, Seung-Hun
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.05
    • /
    • pp.49-52
    • /
    • 1994
  • We have developed a biological signal measurement, archiving, and communication system (SiMACS). The front end of the system is the intelligent data processing unit (IDPU) which includes ECG, EEG, EMG, blood pressure, respiration, temperature measurement modules, module control and data acquisition unit, real-time display and signal processing unit. IDPUS are connected to central data base unit through LAN(Ethernet). Workstations which receive signals from central DB and provide various signal analysis tools are also connected to the network. The developed PC-based SiMACS is described.

  • PDF