• Title/Summary/Keyword: shape dimension

Search Result 582, Processing Time 0.024 seconds

Non-Dimensional Analysis of a Two-Dimensional Beam Using Linear Stiffness Matrix in Absolute Nodal Coordinate Formulation (절대절점좌표계에서 선형 강성행렬을 활용한 2차원 보의 무차원 해석)

  • Kim, Kun Woo;Lee, Jae Wook;Jang, Jin Seok;Oh, Joo Young;Kang, Ji Heon;Kim, Hyung Ryul;Yoo, Wan Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.1
    • /
    • pp.31-40
    • /
    • 2017
  • Absolute nodal coordinate formulation was developed in the mid-1990s, and is used in the flexible dynamic analysis. In the process of deriving the equation of motion, if the order of polynomial referring to the displacement field increases, then the degrees of freedom increase, as well as the analysis time increases. Therefore, in this study, the primary objective was to reduce the analysis time by transforming the dimensional equation of motion to a non-dimensional equation of motion. After the shape function was rearranged to be non-dimensional and the nodal coordinate was rearranged to be in length dimension, the non-dimensional mass matrix, stiffness matrix, and conservative force was derived from the non-dimensional variables. The verification and efficiency of this non-dimensional equation of motion was performed using two examples; cantilever beam which has the exact solution about static deflection and flexible pendulum.

A Preliminary Study for Assessing the Risk of Road Collapse Using Accelerated Pavement Testing (도로함몰 위험도 평가를 위한 실대형 포장가속시험 기초 연구)

  • Park, Hee Mun;Kim, Yeon Tae;Choi, Ji Young;Kim, Ki Hyun
    • International Journal of Highway Engineering
    • /
    • v.18 no.5
    • /
    • pp.57-62
    • /
    • 2016
  • PURPOSES : The objective of this study is to evaluate the effect of size and depth of cavities on the pavement failure using the full-scale accelerated pavement testing. METHODS : A full-scale testbed was constructed by installing the artificial cavities at a depth of 0.3 m and 0.7 m from the pavement surface for accelerated pavement testing. The cavities were made of ice with a dimension of 0.5 m*0.5m*0.3m, and the thickness of asphalt and base layer were 0.2 m and 0.3 m, respectively. The ground penetrating radar and endoscope testing were conducted to determine the shape and location of cavities. The falling weight deflectometer testing was also performed on the cavity and intact sections to estimate the difference of structural capacity between the two sections. A wheel loading of 80 kN was applied on the pavement section with a speed of 10 km/h in accelerated pavement testing. The permanent deformation was measured periodically at a given number of repetitions. The correlation between the depth and size of cavities and pavement failure was investigated using the accelerated pavement testing results. RESULTS : It is found from FWD testing that the center deflection of cavity section is 10% greater than that of the intact section, indicating the 25% reduction of modulus in subbase layer due to the occurrence of the cavity. The measured permanent deformation of the intact section is approximately 10 mm at 90,000 load repetitions. However, for a cavity section of 0.7 m depth, a permanent deformation of 30 mm was measured at 90,000 load repetitions, which is three times greater than that of the intact section. At cavity section of 0.3 m, the permanent deformation reached up to approximately 90 mm and an elliptical hole occurred at pavement surface after testing. CONCLUSIONS : This study is aimed at determining the pavement failure mechanism due to the occurrence of cavities under the pavement using accelerated pavement testing. In the future, the accelerated pavement testing will be conducted at a pavement section with different depths and sizes of cavities. Test results will be utilized to establish the criteria of risk in road collapse based on the various conditions.

Study on Manufacturing Process of Hollow Main Shaft by Open Die Forging (자유단조공법을 통한 중공형 메인샤프트 제조공정에 관한 연구)

  • Kwon, Yong Chul;Kang, Jong Hun;Kim, Sang Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.2
    • /
    • pp.221-227
    • /
    • 2016
  • The main shaft is one of the key components connecting the rotor hub and gear box of a wind power generator. Typically, main shafts are manufactured by open die forging method. However, the main shaft for large MW class wind generators is designed to be hollow in order to reduce the weight. Additionally, the main shafts are manufactured by a casting process. This study aims to develop a manufacturing process for hollow main shafts by the open die forging method. The design of a forging process for a solid main shaft and hollow shaft was prepared by an open die forging process design scheme. Finite element analyses were performed to obtain the flow stress by a hot compression test at different temperature and strain rates. The control parameters of each forging process, such as temperature and effective strain, were obtained and compared to predict the suitability of the hollow main shaft forging process. Finally, high productivity reflecting material utilization ratio, internal quality, shape, and dimension was verified by the prototypes manufactured by the proposed forging process for hollow main shafts.

The Product Color Effect on Product Color Preference, Product Image and Product Attitude (제품의 색채가 제품의 색채선호도, 이미지, 태도에 미치는 영향)

  • Jang, Nam-Seo;Kim, Sae-Bum
    • Archives of design research
    • /
    • v.20 no.1 s.69
    • /
    • pp.79-88
    • /
    • 2007
  • A company's plan to reform its products' image cannot obtain expected results unless a color plan is included in the reformation plan. A color plan is essential since color conveys to customers much information on function, shape, and material quality of the product. In other words, color is the essential dimension or criteria that customers use when evaluating the quality of goods. Despite the importance of a color plan, companies in Korea are still behind in researching and receiving 'color information' compared to those in more advanced countries. Recognizing the importance of products color, many international companies constantly make their efforts to predict trendy colors and preferred styles of customers before they develop products. It is suggested that domestic companies invest more in color infrastructure to be more successful in making products which can catch the customers' eyes and emotion. Different life styles by age, income level, and gender would be only a few of many factors to be investigated to build color plans for a product. In this study, it is attempted to see the color tendency of young generation by gender, and also to analyze empirically the influence of product's color on its image and customers' behavior. The results are analyzed with frequency analysis, cross tabulation analysis, T-test, one-way ANOVA using SPSS Win 12. The results of this study show that color preference, product image and product attitude are influenced by product's color, and color is an important factor for forming additional emotional value together with the product's original functional value. Judging from the findings, it is recommended that a company undertake careful research before developing a product to find out how customers respond differently to products in different colors especially when the product belongs to the product category where color is considered to be a determinant factor in terms of choosing a brand.

  • PDF

Fractals and Fragmentation of Survivor Grains within Gouge Zones along Boundary Faults in the Tertiary Waeup Basin (제3기 와읍분지 경계단층을 따라 발달하는 단층비지 내 잔류입자의 프랙탈과 파쇄작용)

  • Chang, Tae-Woo
    • The Journal of Engineering Geology
    • /
    • v.20 no.2
    • /
    • pp.183-189
    • /
    • 2010
  • Fault gouge samples were collected from the fault cores of the boundary faults between the Cretaceous Basement and the Tertiary Waeup Basin. Fractal dimensions (D) were obtained by using survivor grains which were analysed from six thin sections of the gouges under the optical microscope. The elliptical survivor grains show a shape preferred orientation almost parallel to clay foliation in matrix, suggesting that it was formed by the rotation of the survivor grains in abundant fine-grained matrix during repeated fault slips. The size distributions of the survivor grains follow power-laws with fractal dimensions in the 2.40-3.02 range. D values of all samples but one are higher than a specific D value equal to 2.58 which predicts the self similarity of fragmentation process in constrained comminution model (Sammis et al., 1987), which indicates large fault slip and multiple faulting. Probably the higher D values than 2.58 mean the non-self-similar evolution of cataclastic rocks where fragmentation mechanism changed from constrained comminution to the grain abrasion accompanying selective fracture of larger grains.

An Experimental Study on the dynamic behavior of 4-Span Cable-Stayed Bridge with ${\pi}$-Type Girder (${\pi}$형 거더를 가진 4경간 사장교의 동적거동에 관한 실험적 연구)

  • Cho, Jae-Young;Kim, Young-Min;Lee, Hak-Eun;Yoon, Ki-Yong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.1 s.12
    • /
    • pp.15-24
    • /
    • 2004
  • Generally, a ${\pi}$-type girder composed of two I-type girders is known to have a significant disadvantage in wind resistance design because of aerodynamic instability. A representative bridge for this girder was Tacoma Narrows Bridge. Since Tacoma Narrows Bridge had very low stiffness of the bridge structure and its cross-section shape had aerodynamic instability, the bridge collapsed after severe torsion and vibration events in 19m/s wind speed. Aerodynamic vibration can be avoided by enhancing structural stiffness and damping factor and conducting a study of cross-section shapes. This study shows the angle of attack for the four-span cable stayed bridge having ${\pi}$-type cross-section and describes the aerodynamic characteristics of the changed cross-section with aerodynamic vibration damping additions, by carrying out two-dimension vibration tests. As a result of uniform flow and turbulent flow, the study shows that because the basic ${\pi}$-type cross-section alone can have efficient wind resistant stability, there is no need to have additional aerodynamic damping equipment. Since this four 230m-main-span bridge has a large frequency and also has a big stiffness compared to other bridges containing a similar cross-section, it has aerodynamic stability under the design wind speed.

The Impact of Humane Entrepreneurship on Business Ecosystem and Economic Development (인간중심 기업가정신이 비즈니스 생태계와 경제개발에 미치는 영향)

  • Kim, Yong Jin;Kim, Ki-Chan;Song, Chang Seok;Kang, Myung Soo
    • The Journal of Small Business Innovation
    • /
    • v.20 no.4
    • /
    • pp.3-10
    • /
    • 2018
  • With the advancement in digital transformation with smart technologies and the collapse of industry borders, increasing is the importance of understanding customer problems, fostering employee capabilities, and enhancing the partner capabilities to properly provide the best service to customers. This is what is called the humane entrepreneurship in the 4th Industrial Revolution. Humane entrepreneurship is believed to play a critical role in developing business ecosystems and thus economic growth of nations. We empirically tested the ideas that 1) entrepreneurship as a meta-structuring action shape the healthiness of business ecosystem and 2) subsequently both entrepreneurship and business ecosystems affect economic development of a country. The results indicate that humane entrepreneurship does not directly affect healthiness of business ecosystem, but the balanced humane entrepreneurship together with opportunity in business ecosystems has a positive relationship with GDP growth. In other words, opportunity can be appropriated by entrepreneurs who have balanced sense between human and enterprise dimension. Data collection and methodologies are discussed further in the paper.

  • PDF

MEMS Fabrication of Microchannel with Poly-Si Layer for Application to Microchip Electrophoresis (마이크로 칩 전기영동에 응용하기 위한 다결정 실리콘 층이 형성된 마이크로 채널의 MEMS 가공 제작)

  • Kim, Tae-Ha;Kim, Da-Young;Chun, Myung-Suk;Lee, Sang-Soon
    • Korean Chemical Engineering Research
    • /
    • v.44 no.5
    • /
    • pp.513-519
    • /
    • 2006
  • We developed two kinds of the microchip for application to electrophoresis based on both glass and quartz employing the MEMS fabrications. The poly-Si layer deposited onto the bonding interface apart from channel regions can play a role as the optical slit cutting off the stray light in order to concentrate the UV ray, from which it is possible to improve the signal-to-noise (S/N) ratio of the detection on a chip. In the glass chip, the deposited poly-Si layer had an important function of the etch mask and provided the bonding surface properly enabling the anodic bonding. The glass wafer including more impurities than quartz one results in the higher surface roughness of the channel wall, which affects subsequently on the microflow behavior of the sample solutions. In order to solve this problem, we prepared here the mixed etchant consisting HF and $NH_4F$ solutions, by which the surface roughness was reduced. Both the shape and the dimension of each channel were observed, and the electroosmotic flow velocities were measured as 0.5 mm/s for quartz and 0.36 mm/s for glass channel by implementing the microchip electrophoresis. Applying the optical slit with poly-Si layer provides that the S/N ratio of the peak is increased as ca. 2 times for quartz chip and ca. 3 times for glass chip. The maximum UV absorbance is also enhanced with ca. 1.6 and 1.7 times, respectively.

Measurement and Estimation for the Clearance of Radioactive Waste Contaminated with Radioisotopes for Medical Application (의료용 방사성폐기물 자체처분을 위한 방사능 측정 및 평가)

  • Kim, Changbum;Park, MinSeok;Kim, Gi-Sub;Jung, Haijo;Jang, Seongjoo
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.8-14
    • /
    • 2014
  • The amounts of radioactive wastes to be disposed in the medical institute have been increased due to development of radiation diagnosis and therapy rapidly. They are produced mostly by the very short lived radioisotopes such as $^{18}F$ used in PET/CT, $^{99m}Tc$, $^{123}I$, $^{125}I$ and $^{201}Tl$, etc. IAEA proposed a criteria for the clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). Radioactive wastes of $^{18}F$, $^{99m}Tc$, $^{123}I$, $^{125}I$ and $^{201}TI$ in the several types of container like Marinelli beaker, vial and plastic, were collected to measure the concentration of the waste of each nuclide in accordance with IAEA criteria. The measurement method and procedure of determining specific activity of the wastes using gamma emitters like MCA, gamma counter and beta emitters were developed. For the efficiency calibration of the detectors, CRM (certified reference material) which has the same dimension and shape was provided by Korea Research Institute of Standards and Science (KRISS). Correction factor of the radioactivity decay was calculated based on the measurement results, and the consideration of mutual relation with theoretical equation. The result of this study will be proposed as ISO standard.

Property of Focal Spot of Electron Beam Depending on the Anode Angle of X-ray Tube Using a Finite Element Method (유한요소법을 이용한 X-선관 양극각도에 의존하는 전자빔 초점 특성 연구)

  • Park, Tae-Young;Noh, Young-Il;Lee, Sang-Suk;Park, Rae-Jun;Kim, Ki-Seon
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.2
    • /
    • pp.52-57
    • /
    • 2015
  • The focal spot of electron beam depending on the anode angle in the structure and major parts of the X-ray tube was investigated by the OPERA-3D/SCALAR simulation program. The simulation worked on four spaces with with two spaces, including anode and cathode of X-ray tube, by applying the finite element method analysis. The analytical model and dimension for the emission orbit of thermal electrons made from one filament of the focused X-ray cathode is affected to the penumbra of detector for the X-ray depending on any real focal spot size. The model shape of focusing cap and focusing tube with an anode target angle and a cathode filament is analyzed by the current density distribution of thermal electrons. The focusing width of thermal electrons for the X-ray tube depended on the anode angle (${\theta}$). The focusing value of electron beams at a region of anode angle having $10^{\circ}{\sim}17^{\circ}$ maintained to below value of $70{\mu}m$. The minimum focal size of the electron beam was $40{\mu}m$ at an anode angle of $15^{\circ}$. The focused X-ray tube of many variables depended on the thermionic emission of hot electrons from the target trajectory. The focusing tube will contribute to the real design of X-ray for the development of future diagnosis medical device.