• Title/Summary/Keyword: severe accidents

Search Result 419, Processing Time 0.031 seconds

A Study of Explosion Risk Assessment for Designation of Dangerous Goods Transshipment Pier at Ulsan Port (울산항 위험물 환적부두 지정을 위한 폭발 위험성 평가에 관한 연구)

  • Kang, Min-Kyoon;Lee, Yun-Sok;Ahn, Young-Joong
    • Journal of Navigation and Port Research
    • /
    • v.45 no.3
    • /
    • pp.109-116
    • /
    • 2021
  • The explosion of a chemical tanker ship during cargo transshipment via double-banking at Ulsan Port, resulted in major damage including fires involving nearby ships. As a follow-up measure to prevent the recurrence of similar accidents, the 'Safety Management of Dangerous Goods in Port' was established, and the designation of a transshipment pier for dangerous goods is required given the risk of explosion and the impact on major facilities in the port. This study evaluated the Fire & Explosion Index of major transshipment cargoes in Ulsan Port to design a transshipment pier based on the Explosion Risk Assessment. Based on the results of Fire & Explosion Index evaluation of styrene monomer and benzene, severe explosion risk was confirmed, and the exposure radius was calculated. Based on the results of the exposure radius, the risk range for each major pier was calculated, and 12 terminals were proposed as transshipment pier candidates considering port facilities, surrounding dangerous facilities, and residential aspects. Since the results of the study suggest transshipment piers based on the risk radius alone, maritime traffic safety, pier and mooring facilities, safety facilities and accessibility for emergency response should be considered comprehensively to designate actual transshipment piers.

A Study on the Importance of Real-Name System for Safety Management through Investigation of Construction Sites (건설현장 실태조사를 통한 안전관리 실명제 중요성에 관한 연구)

  • Yeon Cheol Shin;Sang Hyun Kim;Yu Mi Moon
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.4
    • /
    • pp.817-827
    • /
    • 2022
  • The real-name safety management system is to indicate "safety" after inspection by construction personnel before workers use it for the purpose of preventing safety accidents caused by unsafe conditions in temporary facilities and temporary constructions installed at construction sites. Purpose: By implementing the real-name system for safety management at construction sites, the objective is to respond to the "Severe Accident Punishment Act" and to improve the level of safety management at the same time. Method: In this study, a hierarchical analysis model was produced through previous studies of actual conditions such as types of safety incidents and causality at construction sites. The AHP model was used to calculate integrated weights and rankings with a pairwise comparison questionnaire for experts. Conclusion: As a result of the analysis of the upper classes, construction machinery was evaluated the highest, and real-name management system was evaluated the lowest. As a result of the lower-level analysis, it was considered that opening doors for safety facility management, tower cranes for construction equipment, management under the "Occupational Safety and Health Act" under the real-name management system, and CEO duties for safety management organizations were the most important.

Improvement and Estimation of Effect for Speed Limit Tolerance (속도위반 단속 허용범위 개선안 제시 및 효과 추정)

  • Su-hwan Jeong;Kyeung-hee Han;Min-ho Lee;Choul-ki Lee
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.22 no.2
    • /
    • pp.164-181
    • /
    • 2023
  • In a low speed limit environment, the speed limit tolerance of automated traffic enforcement devices is very high, which is one of the main factors for the low compliance rate. Therefore, in this study, we aimed to the improve the speed limit tolerance and to present a new standard. The effects of the operator and user errors that can cause speeding by drivers were analyzed. Based on the results of the analysis, an improvement of the tolerance was proposed by applying an error in the enforcement device and GPS speed. In addition, long-term expected safety effects such as the accident rate and severity were estimated from the operator's perspective when improving the tolerance. As a result of the estimation, the speed limit compliance rate, accident rate, and change rate of a number of severe accidents due to speed change, and pedestrian traffic accident mortality rate were all improved in all speed limit environments. The introduction of the proposed improvement is expected to improve road safety significantly.

Development of Accident Response Information Sheets for Hydrogen Fluoride (불화수소에 대한 사고대응 정보시트 개발)

  • Yoon, Young Sam;Park, Yeon Shin;Kim, Ki Joon;Cho, Mun Sik;Hwang, Dong Gun;Yoon, Jun heon;Choi, Kyung Hee
    • Korean Journal of Hazardous Materials
    • /
    • v.2 no.1
    • /
    • pp.18-26
    • /
    • 2014
  • We analyzed the demand of competent authorities requiring adequate technical information for initial investigation of chemical accidents. Reflecting technical reports on chemical accident response by environmental agencies in the U.S. and Canada, we presented information on environmental diffusion and toxic effects available for the first chemical accident response. Hydrogen fluoride may have the risk potential to corrode metals and cause serious burns and eye damages. In case of inhalation or intake, it could have severe health effects. The substance itself is inflammable, but once heated, it decomposes producing corrosive and toxic fume. In case of contact with water, it can produce toxic, corrosive, flammable or explosive gases and its solution, a strong acid, may react fiercely with a base. In case of hydrogen fluoride leak, the preventive measures are to decrease steam generation in exposed sites, prevent the transfer of vapor cloud and promptly respond using inflammable substances including calcium carbonate, sodium bicarbonate, ground limestone, dried soil, dry sand, vermiculite, fly ash and powder cement. The method for fire fighting is to suppress fire with manless hose stanchions or monitor nozzles by wearing the whole body protective clothing equipped with over-pressure self-contained breathing apparatus from distance. In case of transport accident accompanied with fire, evacuation distance is 1,600m radius. In cae of fire, fire suppression needs to be performed using dry chemicals, CO2, water spray, water fog, and alcohol-resistance foam, etc. The major symptoms by exposure route are dyspnoea, bronchitis, chemical pneumonia and pulmonary edema for respiration, skin laceration, dermatitis, burn, frostbite and erythema for eyes, and nausea, diarrhea, stomachache, and tissue destruction for digestive organs. In atmosphere, its persistency is low, and its bioaccumulation in aquatic organism is also low.

A Review on the Improvement of the Meaning and Composition Requirements of Interference with Fire Protection Activities - Focusing on Interference with 119 EMS Activities - (소방활동방해죄의 의미와 구성요건 개선에 관한 검토 -119구급활동 방해를 중심으로-)

  • Young Pyo Hong
    • The Korean Society of Law and Medicine
    • /
    • v.24 no.3
    • /
    • pp.105-124
    • /
    • 2023
  • Modern society is facing an unstable environment due to unexpected accidents and hazardous situations. For example, incidents such as the collapse of the Bundang Bridge and the crushing accident in Itaewon could serve as examples. In addition to these, critical emergencies like sudden cardiac arrests and strokes frequently occur, requiring swift actions and smooth transfers to specialized medical institutions for effective responses. In response to these risks, the country has been establishing various systems to protect the lives and safety of its citizens. Among these, the 119 First Aid Activities plays a crucial role within the emergency medical system. Its goal is to promptly respond to critical emergency situations involving severe trauma patients or patients with serious illnesses, minimizing damage and safeguarding lives by swiftly transferring them to emergency medical institutions for specialized treatment. The core activity related to this is emergency rescue operations. In particular, the 119 First Aid system serves as a crucial institution responsible for the hospital transportation of emergency patients. However, rescue personnel still encounter cases of interference with their activities during their duties. Despite efforts from the police, these interference cases persist, and they share similarities with the crime of obstructing official duties. Interference with emergency activities exhibits a comparable nature to instances such as physical assaults and equipment damage against emergency medical practitioners working within the emergency medical system. Therefore, a comprehensive understanding and improvement efforts regarding the issues of interference that arise during the process of emergency medical activities, including the 119 First Aid system, are necessary. The solution to these problems is to establish and improve the conditions for obstruction of first aid activities, focusing on the "Framework Act on Firefighting" and the "Act on 119 Rescue and Emergency."

Episode Analysis of the Habit and Phase Changes of Snow Crystals in the Wintertime Yeongdong Region (겨울철 영동지역 눈 결정 습성과 성상 변화 에피소드 분석)

  • Young-Gil Choi;Byung-Gon Kim;Ji-Yun Kim;Tae-Yeon Kim;Jin-Heon Han;GyuWon Lee;Kwonil Kim;Ki-Hoon Kim;Byung-Hwan Lim
    • Atmosphere
    • /
    • v.34 no.2
    • /
    • pp.139-151
    • /
    • 2024
  • The Yeongdong region has suffered from severe snowstorms and the relevant damage such as traffic accidents on slippery roads, and the collapse of greenhouses and temporary buildings. While a lot of research on snowfall has been conducted, the detailed study of snow crystals' phase and habit through intensive observations and the relevant microphysical analysis is still lacking. Therefore, a snowflake camera, PARSIVEL, and intensive radiosonde soundings were utilized to investigate phase and habit changes in solid precipitation. Two remarkable episodes of phase and habit changes were selected such as 19 March 2022 and 15 February 2023. Both events occurred in the synoptic condition of the High in the north and the Low passing by the south, which was accompanied by rapid temperature cooling below 2.5 km. During the events of a short period between 3 to 6 hours, the temperature at 850 hPa decreased by about 4 to 6℃. This cooling led to a change in the main habit of snow particles from riming to aggregate, identified with both MASC and PARSIVEL. Meanwhile, the LDAPS model analyses do not successively represent the rapid cooling and short-term variations of solid precipitation, probably by virtue of overestimating low-level equivalent potential temperature during these periods. The underlying causes of these the low-level temperature variations within 6 hours, still remain unclear. It might be associated with mesoscale orographic phenomenon due to the mountains and East Sea effects, which certainly needs an intensive and comprehensive observation campaign.

Evaluation of Hazardous Zones by Evacuation Scenario under Disasters on Training Ships (실습선 재난 시 피난 시나리오 별 위험구역 평가)

  • SangJin Lim;YoonHo Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.30 no.2
    • /
    • pp.200-208
    • /
    • 2024
  • The occurrence a fire on a training ship with a large number of people on board can lead to severe casualties. Hence the Seafarers' Act and Safety Life At Sea(SOLAS) emphasizes the importance of the abandon ship drill. Therefore, in this study, the training ship of Mokpo National Maritime University, Segero, which has a large number of people on board, was selected as the target ship and the likelihood and severity of fire accidents on each deck were predicted through the preliminary hazard analysis(PHA) qualitative risk assessment. Additionally, assuming a fire in a high-risk area, a simulation of evacuation time and population density was performed to quantitatively predict the risk. The the total evacuation time was predicted to be the longest at 501s in the meal time scenario, in which the population distribution was concentrated in one area. Depending on the scenario, some decks had relatively high population densities of over 1.4pers/m2, preventing stagnation in the number of evacuees. The results of this study are expected to be used as basic data to develop training scenarios for training ships by quantifying evacuation time and population density according to various evacuation scenarios, and the research can be expanded in the future through comparison of mathematical models and experimental values.

Analysis on Study Cases of Safety Assessment and Cases for Spent Nuclear Fuel Pool Accident (사용후핵연료 습식저장시설 사고 안전성 평가 연구 현황 및 사고 사례 분석)

  • Shin Dong Lee;Hyeok Jae Kim;Geon Woo Son;Kwang Pyo Kim
    • Journal of Radiation Industry
    • /
    • v.17 no.3
    • /
    • pp.283-292
    • /
    • 2023
  • Spent nuclear fuel corresponds to high-level radioactive waste that has high decay heat and radioactivity. Accordingly, Spent nuclear fuel withdrawn from the reactor core is primarily stored and managed in a spent nuclear fuel pool in the nuclear power plant to reduce decay heat and radioactivity. In Korea, most nuclear power plant store all spent nuclear fuel in a spent nuclear fuel pool. For wet storage, there are no defense in depth different with reactor core. The study related to spent nuclear fuel pool accident should be carried out to ensure safety. Therefore, it is necessary to analyze previous study cases related to safety of spent nuclear fuel pool and accident cases to build foundational knowledge. The Objective of this study is to analyze study cases of safety assessment and cases for spent nuclear fuel pool accident. For analyzing study cases of safety assessment, possible phenomena when spent nuclear fuel pool accident occurring identified, Subsequently, study cases for safety assessment about each phenomena were investigated, and materials & methods and results for each study are analyzed. For analyzing cases for spent nuclear fuel pool accident, we analyzed accident cases caused by loss of cooling and loss of coolant in spent nuclear fuel pool. Subsequently, causes and change of water level and temperature by each accident case are analyzed. As a result of the analysis on study cases of spent nuclear fuel pool accident, the results of the study conducted by each research institute were vary depending on the computer code, materials & methods of experiment and major assumptions used in the study. As a result of analyzing cases for spent nuclear fuel pool accident, it was found that accident cases for loss of cooling is more than cases for loss of coolant accident. Even though the types of accident in spent nuclear fuel pool were similar, the specific causes were different by each accident case. All the accident cases analyzed did not lead to severe accidents, such as nuclear fuel being exposed to the air. The result of this study will be used as fundamental data for study on spent nuclear fuel pool accident that will be conducted in the future.

COATED PARTICLE FUEL FOR HIGH TEMPERATURE GAS COOLED REACTORS

  • Verfondern, Karl;Nabielek, Heinz;Kendall, James M.
    • Nuclear Engineering and Technology
    • /
    • v.39 no.5
    • /
    • pp.603-616
    • /
    • 2007
  • Roy Huddle, having invented the coated particle in Harwell 1957, stated in the early 1970s that we know now everything about particles and coatings and should be going over to deal with other problems. This was on the occasion of the Dragon fuel performance information meeting London 1973: How wrong a genius be! It took until 1978 that really good particles were made in Germany, then during the Japanese HTTR production in the 1990s and finally the Chinese 2000-2001 campaign for HTR-10. Here, we present a review of history and present status. Today, good fuel is measured by different standards from the seventies: where $9*10^{-4}$ initial free heavy metal fraction was typical for early AVR carbide fuel and $3*10^{-4}$ initial free heavy metal fraction was acceptable for oxide fuel in THTR, we insist on values more than an order of magnitude below this value today. Half a percent of particle failure at the end-of-irradiation, another ancient standard, is not even acceptable today, even for the most severe accidents. While legislation and licensing has not changed, one of the reasons we insist on these improvements is the preference for passive systems rather than active controls of earlier times. After renewed HTGR interest, we are reporting about the start of new or reactivated coated particle work in several parts of the world, considering the aspects of designs/ traditional and new materials, manufacturing technologies/ quality control quality assurance, irradiation and accident performance, modeling and performance predictions, and fuel cycle aspects and spent fuel treatment. In very general terms, the coated particle should be strong, reliable, retentive, and affordable. These properties have to be quantified and will be eventually optimized for a specific application system. Results obtained so far indicate that the same particle can be used for steam cycle applications with $700-750^{\circ}C$ helium coolant gas exit, for gas turbine applications at $850-900^{\circ}C$ and for process heat/hydrogen generation applications with $950^{\circ}C$ outlet temperatures. There is a clear set of standards for modem high quality fuel in terms of low levels of heavy metal contamination, manufacture-induced particle defects during fuel body and fuel element making, irradiation/accident induced particle failures and limits on fission product release from intact particles. While gas-cooled reactor design is still open-ended with blocks for the prismatic and spherical fuel elements for the pebble-bed design, there is near worldwide agreement on high quality fuel: a $500{\mu}m$ diameter $UO_2$ kernel of 10% enrichment is surrounded by a $100{\mu}m$ thick sacrificial buffer layer to be followed by a dense inner pyrocarbon layer, a high quality silicon carbide layer of $35{\mu}m$ thickness and theoretical density and another outer pyrocarbon layer. Good performance has been demonstrated both under operational and under accident conditions, i.e. to 10% FIMA and maximum $1600^{\circ}C$ afterwards. And it is the wide-ranging demonstration experience that makes this particle superior. Recommendations are made for further work: 1. Generation of data for presently manufactured materials, e.g. SiC strength and strength distribution, PyC creep and shrinkage and many more material data sets. 2. Renewed start of irradiation and accident testing of modem coated particle fuel. 3. Analysis of existing and newly created data with a view to demonstrate satisfactory performance at burnups beyond 10% FIMA and complete fission product retention even in accidents that go beyond $1600^{\circ}C$ for a short period of time. This work should proceed at both national and international level.

The Risk Assessment of the Fire Occurrence According to Urban Facilities in Jinju-si (진주시 도시시설물별 화재발생 위험도 평가)

  • Bae, Gyu Han;Won, Tae Hong;Yoo, Hwan Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.1
    • /
    • pp.43-50
    • /
    • 2016
  • Urbanization in Korea has increased significantly and subsequently, various facilities have been concentrated in urban areas at high speed in accordance with a growing urban population. Accordingly, damages have occurred due to a variety of disasters. In particular, fire damage among the social disasters caused the most severe damage in urban areas along with traffic accidents. 44,432 cases of fire occurred in 2015 in Korea. Due to these accidents, 253 were killed and property damage of 4,50 billion won was generated. However, despite the efforts to reduce a variety of damage, fire danger still remains high. In this regard, this study collected fire data, generated from 2007 to 2014 through the Jinju Fire Department and the National Fire Data System(NFDS) and calculated fire risk by analyzing the clustering of fire cases and facilities in Jinju-si based on the current DB of facilities, offered by the Ministry of Government Administration and Home Affairs. As a result, the risk ratings of fire occurrence were classified as four stages under the standards of the US Society of Fire Protection Engineers(SEPE). Business facilities, entertainment facilities, and automobile facilities were classified as the highest A grade, detached houses, Apartment houses, education facilities, sales facilities, accommodation, set of facilities, medical facilities, industrial facilities, and life service facilities were classified as U grade, and other facilities were classified as EU grade. Finally, hazardous production facilities were classified as BEU grade, the lowest grade. In addition, in the case of setting the standard with loss of life, the highest risk facility was the hazardous production facilities, while in the case of setting the standard with property damage, a set of facilities and industrial facilities showed the highest risk. In this regard, this study is expected to be effectively utilized to establish the fire reduction measures against facilities, distributed in urban space by calculating risk grades regarding the generation frequency, casualties, and property damage, through the classification of fire, occurred in the city, according to the facilities.