• Title/Summary/Keyword: sensor-less

Search Result 1,060, Processing Time 0.029 seconds

Sensing characteristics of polyaniline sensor coated with porous PVDF layers to methanol gas under various humidity conditions (다공성 PVDF막이 코팅된 Polyaniline 센서의 다양한 습도분위기의 메탄올 가스에 대한 감응특성)

  • Lim, Cheol-Beom;Sohn, Sung-Ok;Huh, Jeung-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.205-210
    • /
    • 2006
  • Hydrophobic polymer [ex. Poly(vinylidenfluoride)] layer was coated on polyaniline (PANi) sensor to reduce the contamination humidity. The differences in sensitivity to methanol gas detection in various humidity condition between pure-PANi sensor and sensor coated with poly(vinylidenfluoride) polymer (PVDF) (coated-PANi sensor) were investigated. Considering the relation between the density of pore, which was coated on the layer of the PANi sensor, and sensitivity was investigated. To fabricate the porous PVDF layer on PANi sensor, poly(vinylalcohol) (PVA), which is water-soluble polymer, was used. Coated-PANi sensor was less affected by humidity compared with pure-PANi sensor. And higher density of pore on PVDF layer led to higher sensitivity.

Signal Characteristics of Fiber Bragg Grating Sensor with Gage Length (광섬유 브래그 격자 센서의 게이지 길이에 따른 신호 특성)

  • 강동훈;김대현;방형준;홍창선;김천곤
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.155-160
    • /
    • 2002
  • A new fabrication method of FBG sensor with gage length shorter than 10 mm is introduced using the reflection prism with special coating on the surface. It is verified that the bandwidth of FBG sensor increases exponentially as the gage length of it decreases. The transverse stress and strain gradient induced by local stress concentration which occurs during curing has an influence on the FBG sensor with gage length of 2 mm less than that of 10 mm.

  • PDF

Design of Temperature System Using BiCMOS (BiCMOS를 이용한 온도 센서 시스템의 설계)

  • 최진호
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.8
    • /
    • pp.330-334
    • /
    • 2003
  • A Temperature sensor system in which the digital output signal is proportional to the operating temperature is designed. The temperature sensor system is designed by using BiCMOS technology and consists of temperature sensor, voltage-to-frequency converter and counter. The proposed temperature sensor system has error less than $1^{\circ}C$ in the temperature range $-25^{\circ}C$ to $55^{\circ}C$.

Design of a Six-axis Force/moment Sensor for Wrist Twist-exercise Rehabilitation Robot (손목회전운동 재활로봇을 위한 6축 힘/모멘트센서 설계)

  • Kim, Hyeon Min;Kim, Gab Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.5
    • /
    • pp.529-536
    • /
    • 2013
  • Most serious stroke patients have the paralysis on their wrists, and can't use their hands freely. But their wrists can be recovered by rehabilitation exercises. Recently, professional rehabilitation therapeutists help stroke patients exercise their wrists in hospital. But it is difficult for them to rehabilitate their wrists, because the therapeutists are much less than stroke patients in number. Therefore, the wrist twist-exercise rehabilitation robot that can measure the twist force of the patients' wrists is needed and developed. In this paper, the six-axis force/moment sensor was designed appropriately for the robot. As a test result, the interference error of the six-axis force/moment sensor was less than 0.85%. It is thought that the sensor can be used to measure the wrist twist force of the patient.

2D Location Estimation of a Magnetized Tip Using Arrayed GMR Sensors (GMR센서 배열을 이용한 자석팁의 2D 위치 추정)

  • Lee, S.C.;Kim, J.K.;Ahn, J.H.;Kim, H.Y.
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.395-401
    • /
    • 2019
  • This paper proposes a method for estimating the location of a magnetized tip that is inside a non-transparent space or body by using arrayed giant magnetoresistance (GMR) sensors. In general, an object located in such an opaque space can be detected using X-rays, magnetic fields, ultra-sonic sensors, etc., depending on its characteristics. X-ray is mostly used for medical purposes but frequent exposure to it could cause harm to patients as well as doctors. In this study, how well a GMR sensor is applicable instead of an X-ray is investigated. The sensor's voltage output is experimentally fitted to distance with a relationship of 3rd degree polynomial. To detect a small magnetized tip with 900 Oe inside a human body, a 2×2 arrayed GMR sensor and a location estimation algorithm based on information acquired from four sensors is developed. Evaluation tests show that the suggested method is applicable to limited cases with a distance less than 33-55 mm, and the location of a magnet tip is estimated relatively well with an error less than 1.5 mm.

Camera Source Identification of Digital Images Based on Sample Selection

  • Wang, Zhihui;Wang, Hong;Li, Haojie
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.7
    • /
    • pp.3268-3283
    • /
    • 2018
  • With the advent of the Information Age, the source identification of digital images, as a part of digital image forensics, has attracted increasing attention. Therefore, an effective technique to identify the source of digital images is urgently needed at this stage. In this paper, first, we study and implement some previous work on image source identification based on sensor pattern noise, such as the Lukas method, principal component analysis method and the random subspace method. Second, to extract a purer sensor pattern noise, we propose a sample selection method to improve the random subspace method. By analyzing the image texture feature, we select a patch with less complexity to extract more reliable sensor pattern noise, which improves the accuracy of identification. Finally, experiment results reveal that the proposed sample selection method can extract a purer sensor pattern noise, which further improves the accuracy of image source identification. At the same time, this approach is less complicated than the deep learning models and is close to the most advanced performance.

Design of Force Measuring System for Deburring Using Industrial Robot (산업용로봇을 이용한 디버링을 위한 힘측정시스템 설계)

  • Lee, Gyeong Jun;Kim, Han Sol;Kim, Chong Jin;Kim, Hyeon Min;Kim, Gab Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.7
    • /
    • pp.653-660
    • /
    • 2015
  • This paper describes the design of the force measuring system for an industrial robot's deburring work. The force measuring system is composed of a three-axis force sensor, a measuring device, a housing and a cover. The three-axis force sensor can detect x-direction force, y-direction force and z-direction force at the same time. The measuring device is designed using DSP(Digital Signal Processor), and have a RS-232 and a RS-485 communication port for sending force data to PC or other controller. As a result of test, the repeatability error and the non-lineality error of the three-axis force sensor are less than 0.03%, and the interference error of the sensor is less than 0.95%. It is thought that the force measuring system can be used for an industrial robot's deburring work.

A Time Synchronization Protocol for Wireless Body Sensor Networks (무선 인체 센서 네트워크용 시각 동기화 프로토콜)

  • Bae, Shi-Kyu
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.5 no.6
    • /
    • pp.127-134
    • /
    • 2016
  • WBSN (Wireless Body Sensor Network), also called WBAN (Wireless Body Area Networks) generally, is a kind of WSN (Wireless Sensor Network) applications, which is composed of the various sensor nodes residing in human body embodied or in wearable way. The measured data at each sensor node in WBSN requires being synchronized at sink node for exact analysis for status of human body, which is like WSN. Although many time synchronization protocols for WSN has been already developed, they are not appropriate to WBSN. In this paper, a new time synchronization protocol for WBSN considering the characteristics of WBSN is proposed. The proposed scheme is not only simple, but also consumes less power, leading to increasing network life time. We will show that the proposed scheme is appropriate to WBSN by evaluating its performance by simulation.

Simulated Analysis on Cooling System Performance Influenced by Faults Occurred in Enthalpy Sensor for Economizer Control

  • Minho KIM;San JIN;Ahmin JANG;Beungyong PARK;Sung Lok DO
    • International conference on construction engineering and project management
    • /
    • 2024.07a
    • /
    • pp.1002-1009
    • /
    • 2024
  • An economizer control is used for cooling a building by modulating outdoor air(OA) intake rate according to measured OA conditions. An OA enthalpy sensor can be faulty during the operating after installation. The sensor mainly is fault in the form of offset. It leads value differences between measured enthalpy and actual enthalpy. The enthalpy differences occurred by the faulty sensor may result in more OA intake or less OA intake than designed OA intake value. The unwanted amount of OA intake negatively affects cooling system performance, especially cooling energy consumption. Therefore, this study analyzed cooling system performance resulted from occurring the faulty sensor in economizer enthalpy control. To conduct the analysis, this study utilized the Fault model in EnergyPlus, a building energy simulation tool. As a result of the analysis, the faulty sensor with positive offset intaked less OA amount than the available OA amount. It lead more cooling energy consumed by cooling equipment such as chiller and circulation pump. On the other hand, the faulty sensor with negative offset intaked more unnecessary OA amount than the required OA amount. It also lead more cooling energy consumption in the cooling equipment. Based on the resultant analysis, this study suggests continuous maintenance and diagnosis for an enthalpy sensor used in the economizer system. It may allow proper operation control for the economizer system, and thus the maximum cooling energy saving can be achieved.

A Continuous Conduction mode/Critical Conduction Mode Active Power Factor Correction Circuit with Input Voltage Sensor-less Control (입력전압을 감지하지 않는 전류연속/임계동작모드 Active Power Factor Correction Circuit)

  • Roh, Yong-Seong;Yoo, Changsik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.151-161
    • /
    • 2013
  • An active power factor correction (PFC) circuit is presented which employs a newly proposed input voltage sensor-less control technique operated in continuous conduction mode (CCM) and critical conduction mode (CRM). The conventional PFC circuit with input voltage sensor-less control technique degrades the power factor (PF) under the light load condition due to DCM operation. In the proposed PFC circuit, the switching frequency is basically 70KHz in CCM operation. In light load condition, however, the PFC circuit operates in CRM and the switching frequency is increased up to 200KHz. So CCM/CRM operation of the PFC circuit alleviates the decreasing of the PF in light load condition. The proposed PFC controller IC has been implemented in a $0.35{\mu}m$ BCDMOS process and a 240W PFC prototype is built. Experimental results shows the PF of the proposed PFC circuit is improved up to 10% from the one employing the conventional CCM/DCM dual mode control technique. Also, the PF is improved up to 4% in the light load condition of the IEC 61000-3-2 Class D specifications.