• Title/Summary/Keyword: second lens

Search Result 150, Processing Time 0.022 seconds

A Single Lens Micro-Angle Sensor

  • Saito, Yusuke;Gao, Wei;Kiyono, Satoshi
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.2
    • /
    • pp.14-19
    • /
    • 2007
  • Angle sensors based on the principle of autocollimation, which are usually called autocollimators, can accurately measure small tilt angles of a light-reflecting flat surface. This paper describes a prototype micro-angle sensor that is based on the laser autocollimation technique. The new angle sensor is compact and consists of a laser diode as the light source and a quadrant photodiode as a position-sensing device. Because of its concise design, the microangle sensor facilitates dynamic measurements of the angular error motions of a precision stage without influencing the original dynamic properties of the stage. This is because the sensor only requires a small extra target mirror to be mounted on the stage. The sensitivity of the angle detection is independent of the focal length of the objective lens; therefore, an objective lens with a relatively short focal length is employed to reduce the size of the device. The micro-angle sensor uses a single lens for the both the laser collimation and focusing, which distinguishes it from the conventional laser autocollimation method that has separate collimate and objective lenses. The new micro-angle sensor has dimensions of $15.1\times22.0\times14.0mm$ and its resolution is better than 0.1 arc-second The optical design and performance of this micro-angle sensor were verified by experimental results.

Improved Image Restoration Algorithm about Vehicle Camera for Corresponding of Harsh Conditions (가혹한 조건에 대응하기 위한 차량용 카메라의 개선된 영상복원 알고리즘)

  • Jang, Young-Min;Cho, Sang-Bock;Lee, Jong-Hwa
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.2
    • /
    • pp.114-123
    • /
    • 2014
  • Vehicle Black Box (Event Data Recorder EDR) only recognizes the general surrounding environments of load. In addition, general EDR is difficult to recognize the images of a sudden illumination change. It appears that the lens is being a severe distortion. Therefore, general EDR does not provide the clues of the circumstances of the accident. To solve this problem, we estimate the value of Normalized Luminance Descriptor(NLD) and Normalized Contrast Descriptor(NCD). Illumination change is corrected using Normalized Image Quality(NIQ). Second, we are corrected lens distortion using model of Field Of View(FOV) based on designed method of fisheye lens. As a result, we propose integration algorithm of two methods that correct distortions of images using each Gamma Correction and Lens Correction in parallel.

Optical Design of an Inspection Apparatus for Dynamic Visual Acuity (동체시력 검사기의 광학계 설계)

  • Lee, Dong-Hee;Kim, Hye-Dong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.473-480
    • /
    • 2004
  • Recently, they are interested in the relation between night's vehicle accidents of drivers and the dynamic visual acuity at home and aboard. So, in this research, we tried to design an optical system of the inspection equipment to measure the dynamic visual acuity. A optotype standard did to Landolt's ring with 45mm of diameter and 9mm of gap to maintain the visual acuity of 1.0 in the 30m distance. An optical structure of the inspection equipment was composed of the sequence of an observer, a plus refraction lens system, a minus refraction lens system, and an optotype that was arranged to have characteristics that the size of the first virtual image of the optotype made by the minus refraction lens system grows bigger gradually according to the optotype movement to near distance from far distance, and also the first virtual image moves to the principle plane from the focal point of the plus refraction lens system as the size of the first virtual image arranged to the inside of focal distance of plus refraction lens system grows bigger gradually. As doing these processes, we completed the optical system of which characteristic is that the position of the final second virtual image moves to 3m from 50m as the size of the second virtual image made by the plus refraction lens system maintains to be regular.

  • PDF

The Difference of Tear Break-Up Time by the Fitting States of Soft Contact Lens in Normal and Dry Eyes (정상안과 건성안에서 소프트렌즈 피팅 상태에 따른 비침입성 눈물막 파괴 시간의 차이)

  • Jung, Da I;Lee, Heum Sook;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.339-346
    • /
    • 2010
  • Purpose: The study was performed to compare the difference of non-invasive tear break-up time (NIBUT) with alignment or steep fitting of soft contact lens in normal and dry eyes. Methods: Total 40 eyes (aged 20~30 years) were classified to the normal (n=20) or dry eye group (n=20) by the diagnosis methods for dry eyes and worn soft contact lens (polymacon material) with alignment or steep fitting. NIBUTs of lens wearers were separately measured at the points of before wearing, immediately after wearing and after stabilization of tear film. Results: With alignment fitting, averaged NIBUT in the dry eye group after stabilization of tear film was not significantly different from that of the normal eye group. However, averaged NIBUTs in the normal and dry eyes had significant difference when measured immediately after lens wearing. However, the number of eyes having NIBUT less than 4.0 second was 30% higher compared to the number of normal eyes with steep fitting when measured immediately after wearing. Some shorten NIBUT in dry eyes with steep fitting was also shown after stabilization of tear film. Conclusions: These results suggest that wearing soft contact lens in dry eyes differently affect tear film compared to normal eyes. Thus, dry eyes need more advertent fitting for contact lens wearing because of unstable tear film.

Fabrication and Performance Evaluation of MR-16 Lamp Series with Narrow Angular Distribution of Luminous Intensity Using an Aspherical Planar-convex 2×2 Fly-eye Lens Type (평면-비구면 2×2 fly-eye 렌즈형태의 2차 렌즈를 사용한 고효율의 좁은 배광각을 갖는 MR-16 램프 시리즈 제작 및 성능평가)

  • Chu, Kyung-duk;Ryu, Jae Myung;Hong, Chun-Gang;Jeong, Youn Hong;Jo, Jae Heung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.8
    • /
    • pp.25-33
    • /
    • 2017
  • This paper reports the optical design of the MR-16 lamp series with a LED second lens and an aspherical plano-convex lens suitable for a simple and rapid injection molding fabrication method. The fabrication and performance evaluation of the MR-16 lamp series, which was designed with a narrow angular distribution of luminous intensity, were conducted to replace halogen lamps with LED lamps. Four types of LED lamps were fabricated, which have angular distributions of luminous intensity of $22.4^{\circ}$, $31.1^{\circ}$, $37.3^{\circ}$, and $59.9^{\circ}$ and luminous efficiencies of 76.5 lm/W, 75.2 lm/W, 72.0 lm/W, and 77.8 lm/W, respectively, while their spreading angles with an illuminance uniformity of 81% were $3^{\circ}$, $15^{\circ}$, $22^{\circ}$, and $49^{\circ}$, respectively. After eliminating a yellow tail of the LED lamps using a diffusion sheet, the angular distributions of the luminous intensity were measured to be $20.8^{\circ}$, $31.5^{\circ}$, $37.8^{\circ}$, and $68.7^{\circ}$.

Analysis of Concentration Distribution and Diffusion Depth in Tinted Lenses Using the Law of Diffusion (확산법칙을 이용한 착색렌즈에서의 농도분포와 확산깊이의 분석)

  • Choi, Eun Jung;Lee, Sin Ui
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.403-408
    • /
    • 2011
  • Purpose: To study the concentration distribution and diffusion depth in tinted lenses using the law of diffusion. Methods: The measured values taken from experiments were fitted with the theoretical fitting curve induced on the basis of Fick's second law of diffusion. Results: The fitting curves were in very good agreement with the measured values. As the results, we found the quantitative relationship between mass of dye solution diffused into the tinted lens per unit area and dyeing time, and evaluated concentration distribution of dye in tinted lens, diffusion depth, etc. Conclusions: The dyeing mechanism of tinted lenses can be well described by diffusion theory.

Strain-induced islands and nanostructures shape transition's chronology on InAs (100) surface

  • Gambaryan, Karen M.;Aroutiounian, Vladimir M.;Simonyan, Arpine K.;Ai, Yuanfei;Ashalley, Eric;Wang, Zhiming M.
    • Advances in nano research
    • /
    • v.2 no.4
    • /
    • pp.211-217
    • /
    • 2014
  • The self-assembled strain-induced sub-micrometric islands and nanostructures are grown from In-As-Sb-P quaternary liquid phase on InAs (100) substrates in Stranski-Krastanow growth mode. Two samples are under consideration. The first sample consists of unencapsulated islands and lens-shape quantum dots (QDs) grown from expressly inhomogeneous liquid phase. The second sample is an n-InAs/p-InAsSbP heterostructure with QDs embedded in the p-n junction interface. The morphology, size and shape of the structures are investigated by high-resolution scanning electron (SEM) and transmission electron (TEM) microscopy. It is shown that islands, as they decrease in size, undergo shape transitions. Particularly, as the volume decreases, the following succession of shape transitions are detected: sub-micrometric truncated pyramid, {111} facetted pyramid, {111} and partially {105} facetted pyramid, completely unfacetted "pre-pyramid", hemisphere, lens-shaped QD, which then evolves again to nano-pyramid. A critical size of $5{\pm}2nm$ for the shape transformation of InAsSbP-based lens-shaped QD to nano-pyramid is experimentally measured and theoretically evaluated.

Polymorphism Assessment of Six Lentil (Lens culinaris Medik.) Genotypes Using Isozyme

  • Madina, M. Hur;Rahman, M. Saifur;Deb, A. Chandra;Choi, Yun Hee;Kim, Mi Ri;Shin, Jihoon;Yoo, Jin Cheol
    • Journal of Integrative Natural Science
    • /
    • v.8 no.2
    • /
    • pp.117-127
    • /
    • 2015
  • Lentil (Lens culinaris Medik.) is one of the important legumes and cheaper source of protein in Bangladesh that displays great biological diversity. Isozyme, one of the most important protein markers to detect genetic polymorphism in lentil, whereas we considered thirteen-isozyme in six varieties viz., BARI masur-1, BARI masur-2, BARI masur-3, BARI masur-4, BARI masur-5 and BARI masur-6. The highest polymorphism was found in tyrosinase isozyme system. UPGMA analysis revealed that the highest similarity between BARI masur-5 and BARI masur-6 whereas, the highest genetic distance between BARI masur-1 and BARI masur-5 reflecting higher intervarietal variation. Principal component analysis (PCA) also revealed the similar results that of unweighted pair group method with arithmetic mean (UPGMA). The first, second and third PCs contributed 81.58%, 11.19% and 4.94% variation respectively, with cumulative variation of the first three PCs was 75.45%. Consequently, Isozyme could clearly assed the genetic diversity at intervarietal levels and these two varieties can be considered as valuable gene resources for future breeding and conservation programs.

A Study on Pressing Conditions in the molding of Aspheric Glass Lenses for Phone Camera Module using Design of Experiments (DOE를 적용한 카메라폰 모듈용 비구면 Glass 렌즈의 가압성형조건 연구)

  • Kim, Hye-Jeong;Cha, Du-Hwan;Lee, Jun-Key;Kim, Sang-Suk;Kim, Jeong-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.8
    • /
    • pp.720-725
    • /
    • 2007
  • This study investigated the pressing conditions in the molding of aspheric glass lenses for the mega pixel phone camera module using the DOE method. Tungsten carbide (WC; Japan, Everloy Co., 002K),which contained 0.5 w% cobalt (Co), was used to build the mold. The mold surface was ultra-precision ground and polished, and its form accuracy (PV) was 0.85um in aspheric surface. We selected four factors, pressing temperature, force and time of first step, and force of second step, respectively, as the parameters of the pressing process. in order to reduce the number of experiments, we applied fractional factorial design considering the main effects and two-way interactions. The analysis results indicate that the only two main effects, the pressing temperature and the time of pressing step 1, are available for the form accuracy (PV) of the molded lens. The analysis results indicated that the best combination of the factors for lowering the form accuracy(PV) value of molded lens was to have them at their low levels.

The setup of the moiré deflectometry using the virtual grating and the measurement of the effective focal length (가상격자를 사용한 무아레 무늬 발생기의 구성과 유효초점거리 측정)

  • Kim, Sang Gee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.181-186
    • /
    • 2000
  • The setup of the moir$\acute{e}$ deflectometry using the virtual grating was done, so the convergence and divergence of a pencil of ray was determined. The light source was He-Ne laser(3mW). The focal length of the first lens, the second lens being 18 mm, 250 mm respectively was used for the setup of the beam expander. The optics of the moir$\acute{e}$ deflectometry determining the vergence was used a diffraction grating(pitch = $1.6{\mu}m/line$) and a front flat reflection mirror. The effective focal length of the trial lens set was measured and compared with the theoretical value.

  • PDF