• Title/Summary/Keyword: school indoor facilities

Search Result 110, Processing Time 0.027 seconds

A Study on the Educational Welfare Facilities for Disability-friendly Campus (장애친화적 캠퍼스를 위한 교육복지시설에 관한 연구)

  • Kim, Hak Cheol
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.24 no.4
    • /
    • pp.25-32
    • /
    • 2022
  • The purpose of this study is to provide design guidelines necessary for creating disability-friendly campuses. To this end, a literature survey and a survey on the current educational welfare facilities for disabled college students were conducted. The fact-finding survey was conducted in writing and visiting evaluations on 19 campuses located in Gangwon-do(province). The results of this study are summarized as follows: 1) The college enrollment rate of the disabled has doubled since 2000, but it was found to be half of the enrollment rate based on school enrollment, and the number of students who gave up in the middle is increasing. This is due to an obstacle in the learning environment, so it is necessary to improve welfare facilities. 2) As a result of evaluating the status of educational welfare support for students with disabilities, it was found that the overall evaluation result was improved, but the absolute evaluation result was less than 70%, and it was not improved. 3) As a result of evaluating the actual conditions of the intermediate facilities, indoor facilities, sanitary facilities, guidance and other facilities, and unit spaces, it is necessary to expand and improve them due to the lack of disabled parking marks, continuity of access roads, pedestrian safety passages, lifts, and rest areas for the disabled.

A Study on the Energy Level of Education Facilities in Green Building Certification Criteria (학교시설 친환경인증 사례를 통한 에너지 평가항목에 대한 연구)

  • Kwon, Young-Cheol;Kwag, Moon-Geun;Choi, Chang-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.12
    • /
    • pp.688-694
    • /
    • 2009
  • With the increase in the demand for sustainable and environmentally-friendly development, Green Building Certification System came into force in 2002, Evaluation parts of Green Building Certification System are divided into land use and transportation, energy, ecological environment, and indoor environment. Alloted point for the part of energy is larger than other part, thus we can say that this part is very important to increase the green building performance. This study aims to analyze the present condition of design and construction for the part of energy in the certificated green school building. Total 40 certificated school buildings were selected and average scoring rate of each item was evaluated. Key particular to be considered were suggested to improve the item of energy consumption.

Indoor Air Quality Monitoring Systems in the IoT Environment (IoT 기반 실내 공기질 모니터링 시스템)

  • Oh, Chang-Se;Seo, Min-Seok;Lee, Jung-Hyuck;Kim, Sang-Hyun;Kim, Young-Don;Park, Hyun-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.5
    • /
    • pp.886-891
    • /
    • 2015
  • Recently, The World Health Organization announced that harms human health because of air pollution that are emerging as threats to human health worldwide. according to the, Seoul, 2011 According to a July 2014 - Public Facilities indoor air quality measurements, were examined to be in violation of indoor air pollution standards in most multi-use facility. Indoor air pollution resulting from this is present in the paper, and cause disease, such as pulmonary disease, asthma, bronchitis and to In this connection, the measurement of indoor air quality by using the environment sensor, analyzing the measured data to generate an actuator signal required for ventilation and improve indoor air quality by implementing a monitoring system with real-time measurement, autonomously managing the air quality in our lives so that it can be.

A Study on Microbial Pollution of Indoor Air at Elderly Care Facilities (노인요양시설의 실내공기 중 미생물 오염에 관한 연구)

  • Kim, Sang-Ha;Kim, Young-Kwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2485-2491
    • /
    • 2009
  • Culture was performed by using Sheep Blood Agar Plate (BAP, Asan Pharmaceutical) and Sabouraud Dextrose Ager (SDA, Asan Pharmaceutical) along with air $IDEAL^{TM}$ (Biomerieux), which is a microbe interceptor based on inertial impaction interception, in order to investigate bioaerosol in indoor and outdoor air at five elderly care facilities in a metropolis and an urban-rural consolidated city for two months from April 1 to May 31, 2007. From the culture followed by isolation and identification, the following conclusions were drawn. 1. As for the general isolation of microbes in each facility, care center S had the largest amount of microbes (263 cfu/$m^3$) isolated in a 300L room, followed by care center U having 123 cfu/$m^3$ isolated. 2. As for the number of bacteria isolated from a medium intercepting 300 L indoor, the largest amount of other unidentified or non-pathogenic Gram positive cocci (321 cfu/$m^3$) was isolated and most of the other Gram positive cocci were CNS (Coagulase Negative Staphylococcus). 3. As for the number of fungi isolated from a medium intercepting 300 L in a room, the largest number of Aspergillus spp. (66) was isolated, followed by Mucor spp. (62 cfu/$m^3$), Penicillium spp. (53 cfu/$m^3$), Alternaria spp. (50), and other unidentified or non-pathogenic fungi (42 cfu/$m^3$). 4. As for the rate of indoor and outdoor pollution, the average number of interceptions was all larger indoor than outdoor; the research differentiating the amount of air into 300 L and 500 L demonstrated that the larger amount of air led to more bacteria, making no great variation in the species.

An analysis of Noise Conditions in Elementary Schools Located near Airport and Roads (항공 및 도로 교통 소음권내 초등학교의 소음실태분석)

  • Choi Yoon Jung
    • Journal of the Korean Home Economics Association
    • /
    • v.43 no.4 s.206
    • /
    • pp.31-47
    • /
    • 2005
  • This study is a preliminary investigation into improving the environmental quality of schools. The purpose was to clarify the present conditions and reasons of noise in elementary schools located near airports and roads by noise level measurements and questionnaire surveys of subjective responses. fold measurements on equivalent and instantaneous noise levels, indoor and outdoor, were carried out in 3 schools during the periods 11th~ 13th of February and 2nd~ 7th of July,2003. The respondents were 94 teachers working in the 3 schools. The results were as follows. 1) Indoor noise levels of the 3 schools were 36.g~73 dB(A) in winter, and 46.9~ 91 dB(A) in summer. These values were higher than the indoor noise standard of 50 dB(A), except for the average of equivalent noise levels in winter.2) Outdoor noise levels of the schools were 41.1 ~ 101 dB(A) in winter, and 52.4~ 102 dB(A) in summer. These values were generally inappropriate relative to the standard for environmental noise of 65 dB(A). 3) The respondents showed relatively non- positive responses during school hours for interruptions by environmental noise.4) The frequently checked types of environmental noise of the schools were 'airplane noise','surrounding facilities', and 'traffic noise'. The frequently checked types of damage by environmental noise were 'Interrupting school hours' and 'Interrupting business'.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2010 (설비공학 분야의 최근 연구 동향 : 2010년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo-Young;Choi, Jong-Min;Kim, Su-Min;Kwon, Young-Chul;Baik, Yong-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.449-469
    • /
    • 2011
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering during 2010. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery, and new and renewable energy. Various topics were presented in the field of general thermal and fluid flow. Research issues mainly focused on the thermal reliability of axial fan and compressor in the field of fluid machinery. Studies on the design of ground source heat pump systems and solar chemical reactors were executed in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (3) Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and CO2 were studied. Performance improvement of refrigeration systems are tried applying various ideas of refrigerant subcooling, dual evaporator with hot gas bypass control and feedforward control. The hybrid solar systems combining the solar collection devices with absorption chillers or compression heat pumps are simulated and studied experimentally as well to improve the understanding and the feasibility for actual applications. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. Various studies on heating and cooling systems, HVAC facilities, indoor air environments and energy resources were carried to improve the maintenance and management of building service equipments. In the field of heating and cooling systems, papers on a transformer cooling system, a combined heat and power, a slab thermal storage and a heat pump were reported. In the field of HVAC facilities, papers on a cooling load, an ondol and a drying were presented. Also, studies on HVAC systems using unutilized indoor air environments and energy resources such as air curtains, bioviolence, cleanrooms, ventilation, district heating, landfill gas were studied. (5) In the field of architectural environment and energy, studies of various purposes were conducted such as indoor environment, building energy, renewable energy and green building. In particular, renewable energy and building energy-related researches have mainly been studied reflecting the global interest. In addition, many researches which related the domestic green building certification of school building were performed to improve the indoor environment of school.

Secondary School Students' Perceptions of School Spaces: What They Like and Dislike (중·고등학생의 호·불호 학교공간 인식에 관한 연구)

  • Park, Jong-Hyang;Shin, Na-Min
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.22 no.1
    • /
    • pp.47-57
    • /
    • 2015
  • This study aimed to identify secondary school students' perceptions of school spaces by researching their place preferences and the reasons for them. For the purpose, we analyzed students' written statements regarding places they like and dislike at school, which were collected from 836 middle and 1,100 high school students enrolled at 4 middle and 4 high schools, respectively. Data were transcribed, encoded, and analyzed so as to be clustered to themes revealing the students' senses of places at school. The results are as follows: (1) for middle school students, the most preferred places had to do with physical activities, including playground, auditorium, gymnasium etc., whereas high school students preferred indoor places such as classrooms; (2) the reasons for like-places were categorized into three themes: functions (physical, social, learning, and everyday activities), emotions (belonging, healing, and aesthetics), and physical characteristics; (3) both middle and high school students regarded restroom as the place that they disliked most; (4) the reasons for dislike-places included physical conditions, atmosphere, person-related, subject-related, and circumstances such as the happening of violence or punishment. These may provide educators, parents, school architects and administrators with practical considerations needed for making school a better place for students at secondary schools.

Users' Satisfaction on the Dormitory of High School in Jeonju City (고등학교 기숙사 주거시설에 대한 사용자 만족도 - 개인공간 단위실을 중심으로 -)

  • An, Jin-Sook;Choi, Byung-Sook
    • Journal of the Korean housing association
    • /
    • v.18 no.6
    • /
    • pp.93-101
    • /
    • 2007
  • This study was to find out users' satisfaction on the dormitory of high school in Jeonju City and to propose it's physical environmental improvement directions. This was performed by a questionnaire survey method, and the questionnaire was designed by researchers considering relative literatures. Data were collected from 200 students, who had been dwelling 4 high school dormitories in Jeonju City. By analyzing those data, findings were as follows: 1) Users of students were satisfied the whole of their dormitory; facilities, spaces, and living. 2) They were highly concerned about a library and a personal unit space in their dormitory. 3) They needed their personal unit space to be designed bedroom+bathroom type with 2 persons' sharing and be equipped one story bed and desk furniture. Also, they needed improvement on heating & cooling, small space and indoor air quality of unit space. 4) The users' satisfaction on unit space were 2.88, and their satisfaction of the technical factor was 2.71 that was the lowest score in them. And The functional factor was highly effected their satisfaction. 5) The space utility and the space size of functional factor, the soundproof, the heating/ventilation and the indoor quality of technical factor, and the privacy of behavior factor were highly correlative to their satisfaction of unit space.

A Study on the Environmental Design of the classroom in Elementary Schools with Particular Reference to Natural Lighting and Sound Insulation Performance (채광 및 차음성능을 고려한 초등학교 교실의 환경계획적 연구)

  • Son, Chang-Hwan;Choi, Young-Jun;Lee, Kyung-Hoi
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.4 no.2
    • /
    • pp.13-20
    • /
    • 1997
  • The total evaluation of educational environment is needed with the rapid growth of the number of students. Especially it is very important to evaluate the physical environment of the classroom in elementary schools where the students spend their whole school life. This study aims to evaluate the daylighting and sound insulation performance of the classroom in elementary school, considering factors such as ceiling height and Wi/Wa (Window/Wall) ratio and then to plan the classroom. Analytic results of the daylighting and sound insulation performance show that the optimum Wi/Wa ratio is $35{\sim}45%$. Reduction of the ceiling height from 3.3m has little influence on the distribution of the indoor daylight factor and sound insulation performance

  • PDF

A Study on the Improvement of the School Green Building Certification System based on Life Cycle Assessment Methodology (LCA개념을 도입한 학교시설 녹색건축인증기준 개선방향에 관한 연구)

  • Lee, Jae-Ok;Kim, Sung-Joong;Lee, Sang-Min;Lee, Seung-Min
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.20 no.3
    • /
    • pp.53-61
    • /
    • 2013
  • The purpose of this study is to suggest the way how to improve the school green building certification system based on life cycle assessment methodology and to assess $LCCO_2$ in outline. Green Building Certification System for School is comprised of 7 categories and 39 items. 7 categories include Land use and Transport, Energy and Atmosphere, Materials and Resources, Water, Management, Ecology, Indoor environmental quality. School is a public facility for students. So Green Building Certification System for School must have educational point of view adding to energy saving, reduction of greenhouse gas emission, etc. Also it needs to be classified into three categories ; kindergarten, elementar/middl/high school and university. Improvement plans for items are as follows ; energy consumption and $LCCO_2$ assessment considering life cycle, deletion or integration of duplicate items by comparing other systems, application of passive solar systems, consideration of the law and standards change, and selection of items considering specific building use.