• Title/Summary/Keyword: school bonding

Search Result 893, Processing Time 0.028 seconds

Effect of Multiple Reflows on the Mechanical Reliability of Solder Joint in LED Package (LED 패키지 솔더 접합부의 기계적 신뢰성에 미치는 리플로우 횟수의 영향)

  • Lee, Young-Chul;Kim, Kwang-Seok;Ahn, Ji-Hyuk;Yoon, Jeong-Won;Ko, Min-Kwan;Jung, Seung-Boo
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.11
    • /
    • pp.1035-1040
    • /
    • 2010
  • The research efforts on GaN-based light-emitting diodes (LEDs) keep increasing due to their significant impact on the illumination industry. Surface mount technology (SMT) is widely used to mount the LED packages for practical application. In surface mount soldering both the device body and leads are intentionally heated by a reflow process. We studied on the effects of multiple reflows on microstructural variation and joint strength of the solder joints between the LED package and the substrate. In this study, Pb-free Sn-3.0Ag-0.5Cu solder and a finished pad with organic solderability preservatives (OSP) were employed. A $Cu_6Sn_5$ intermetallic compound (IMC) layer was formed during the multiple reflows, and the thickness of the IMC layerincreased with an increasing number of reflows. The shear force decreased after three reflows. From the observation of the fracture surface after a shear test, partially brittle fractures were observed after five reflows.

The Association between Family Mealtime and Depression in Elderly Koreans

  • Kang, Yunhwa;Kang, Soyeon;Kim, Kyung Jung;Ko, Hyunyoung;Shin, Jinyoung;Song, Yun-Mi
    • Korean Journal of Family Medicine
    • /
    • v.39 no.6
    • /
    • pp.340-346
    • /
    • 2018
  • Background: Several studies have revealed the frequency of family mealtimes to be inversely associated with depressive symptoms in adolescents. However, there have been few studies in older populations. This cross-sectional study investigated the association between family mealtime frequency and depressive symptoms in elderly Koreans. Methods: This study analyzed 4,959 elderly men and women (aged 65 years or older) who participated in the Korea National Health and Nutrition Examination Survey. Self-administered questionnaires were used to assess depressive status, family mealtime frequency, and covariates. Multiple logistic regression analysis was performed to evaluate the association using the eating alone group as a reference. Results: After adjusting for all covariates, participants who had family meals 3 times a day had fewer depressive symptoms than the eating alone group; adjusted odds ratios (ORs) (95% confidence intervals [CIs]) were 0.72 (0.58-0.89) for point depressiveness/anxiety and 0.73 (0.56-0.94) for depressiveness lasting for at least 2 weeks. In suicidal ideation, the OR (95% CI) of eating with family twice a day was significant after full adjusting for covariates at 0.67 (0.50-0.88). Conclusion: Family mealtimes were closely associated with depressive symptoms in elderly Koreans, which suggests that maintaining intrafamilial bonding is important for mental health in an older population.

Characterization of Rhizophora SPP. particleboards with SOY protein isolate modified with NaOH/IA-PAE adhesive for use as phantom material at photon energies of 16.59-25.26 keV

  • Samson, Damilola Oluwafemi;Shukri, Ahmad;Mat Jafri, Mohd Zubir;Hashim, Rokiah;Sulaiman, Othman;Aziz, Mohd Zahri Abdul;Yusof, Mohd Fahmi Mohd
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.216-233
    • /
    • 2021
  • In this work, Rhizophora spp. particleboard phantoms were made using SPI-based adhesives, modified with sodium hydroxide and itaconic acid polyamidoamine-epichlorohydrin (0, 5, 10, and 15 wt%). An X-ray computed tomography (CT) imaging system was used to ascertain the CT numbers and density distribution profiles of the particleboards. The SPI-based/NaOH/IA-PAE/Rhizophora spp. particleboard phantoms with 15 wt% IA-PAE addition level had the highest solid content, flexural strength, flexural modulus, and internal bonding strength of 36.06 ± 1.08%, 18.61 ± 0.38 Nmm-2, 7605.76 ± 0.89 Nmm-2, and 0.463 ± 0.053 Nmm-2, respectively. The moisture content, mass density, water absorption, and dimensional stability were 6.93 ± 0.27%, 0.962 ± 0.037 gcm-3, 22.36 ± 2.47%, and 10.90 ± 0.86%, respectively. The results revealed that the mass attenuation coefficients and effective atomic number values within the 16.59-25.26 keV photon energy region, were close to the calculated XCOM values in water, with a p-value of 0.077. Moreover, the CT images showed that the dissimilarities in the discrepancy of the profile density decreased as the IA-PAE concentrations increased. Therefore, these results support the appropriateness of the SPI-based/NaOH/IA-PAE/Rhizophora spp. particleboard with 15 wt% IA-PAE adhesive as a suitable tissue-equivalent phantom material for medical health applications.

Comparative evaluation of shear bond strength of orthodontic brackets bonded to three-dimensionally-printed and milled materials after surface treatment and artificial aging

  • Ameer Biadsee;Ofir Rosner;Carol Khalil;Vanina Atanasova;Joel Blushtein;Shifra Levartovsky
    • The korean journal of orthodontics
    • /
    • v.53 no.1
    • /
    • pp.45-53
    • /
    • 2023
  • Objective: This study aimed to evaluate the shear bond strength (SBS) of orthodontic brackets bonded to three-dimensionally (3D)-printed materials after various surface treatments and artificial aging compared with that bonded to computer-aided design/computer-aided manufacturing (CAD-CAM) polymethyl methacrylate (PMMA)-milled materials. Methods: Eighty cylindrical specimens were 3D printed and divided into the following four subgroups (n = 20 each) according to the surface treatment and artificial aging procedure. Group A, sandblasted with 50 ㎛ aluminum oxide particles (SA) and aging; group B, sandblasted with 30 ㎛ silica-coated alumina particles (CO) and aging; group C, SA without aging; and group D, CO without aging. For the control group, 20 CAD-CAM PMMA-milled cylindrical specimens were sandblasted with SA and aged. The SBS was measured using a universal testing machine (0.25 mm/min), examined at ×2.5 magnification for failure mode classification, and statistically analyzed (p = 0.05). Results: The retention obtained with the 3D-printed materials (groups A-D) was higher than that obtained with the PMMA-milled materials (control group). However, no significant difference was found between the study and control groups, except for group C (SA without aging), which showed significantly higher retention than the control group (PMMA-SA and thermocycling) (p = 0.037). Study groups A-D predominantly exhibited a cohesive specimen mode, indicating specimen fracture. Conclusions: Orthodontic brackets bonded to 3D-printed materials exhibit acceptable bonding strengths. However, 3D-printed materials are prone to cohesive failure, which may result in crown fractures.

Pomegranate extract on eroded dentin: antioxidant action, bond strength and morphology of the adhesive interface after aging

  • Thiago Vinicius Cortez;Nathalia Mancioppi Cerqueira;Julia Adornes Gallas;Wanderley Pereira Oliveira;Silmara Aparecida Milori Corona;Aline Evangelista Souza-Gabriel
    • Restorative Dentistry and Endodontics
    • /
    • v.49 no.1
    • /
    • pp.9.1-9.14
    • /
    • 2024
  • Objectives: This study aimed to evaluate the effect of pomegranate solution (Punica granatum) on eroded dentin through antioxidant action, shear bond strength (SBS) and interface morphology. Materials and Methods: The 10% pomegranate peel extract was prepared by the lyophilization method. Punicalagin polyphenol was confirmed by high-performance liquid chromatography. Antioxidant activity was evaluated by capturing the 2,2-diphenyl1-picrylhydrazyl (DPPH) radical. For the SBS, 48 dentin fragments were divided into sound or eroded, and subdivided according to the pretreatment (n = 12): water or P. granatum. The surfaces were restored with self-etch adhesive and a bulk-fill resin (Ecosite; DMG). The SBS was done immediately (24 hours) and after thermal cycling + water storage (12 months). For scanning electron microscopy, 48 dentin fragments (24 sound and 24 eroded) received the same treatments as for SBS (n = 6), and they were analyzed after 24 hours and 12 months. Results: The P. granatum had antioxidant action similar (p = 0.246) to the phenolic standard antioxidants. After 24 hours, eroded dentin had lower SBS than sound dentin (p < 0.001), regardless of the pretreatment. After 12 months, P. granatum maintained the SBS of sound dentin (13.46 ± 3.42 MPa) and eroded dentin (10.96 ± 1.90 MPa) statistically similar. The lowest values were found on eroded dentin treated with water (5.75 ± 1.65 MPa) (p < 0.001). P. granatum on eroded dentin caused peritubular demineralization and hybrid layer with resin tags. Conclusions: The pomegranate extract had antioxidant action and preserved the adhesive interface of the eroded dentin.

THE EFFECT OF THE REMOVAL OF CHONDROITIN SULFATE ON BOND STRENGTH OF DENTIN ADHESIVES AND COLLAGEN ARCHITECTURE (비교원성 단백질이 상아질 접착제의 결합강도와 교원질의 형태에 미치는 영향)

  • Kim, Jong-Ryul;Park, Sang-Jin;Choi, Gi-Woon;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.3
    • /
    • pp.211-221
    • /
    • 2010
  • Proteoglycan is highly hydrophilic and negatively charged which enable them attract the water. The objective of study was to investigate the effects of Proteoglycan on microtensile bond strength of dentin adhesives and on architecture of dentin collagen matrix of acid etched dentin by removing the chondroitin sulphate attached on Proteoglycan. A flat dentin surface in mid-coronal portion of tooth was prepared. After acid etching, half of the specimens were immersed in 0.1 U/mL chondroitinase ABC (C-ABC) for 48 h at $37^{\circ}C$, while the other half were stored in distilled water. Specimens were bonded with the dentin adhesive using three different bonding techniques (wet, dry and re-wet) followed by microtensile bond strength test. SEM examination was done with debonded specimen, resin-dentin interface and acid-etched dentin surface with/without C-ABC treatment. For the subgroups using wet-bonding or dry-bonding technique, microtensile bond strength showed no significant difference after C-ABC treatment (p > 0.05). Nevertheless, the subgroup using rewetting technique after air dry in the Single Bond 2 group demonstrated a significant decrease of microtensile bond strength after C-ABC treatment. Collagen architecture is loosely packed and some fibrils are aggregated together and relatively collapsed compared with normal acid-etched wet dentin after C-ABC treatment. Further studies are necessary for the contribution to the collagen architecture of noncollagenous protein under the various clinical situations and several dentin conditioners and are also needed about long-term effect on bond strength of dentin adhesive.

IS AN OXYGEN INHIBITION LAYER ESSENTIAL FOR THE INTERFACIAL BONDING BETWEEN RESIN COMPOSITE LAYERS? (Layering시 복합레진 층간의 계면 결합에서 oxygen inhibition layer가 필수적인가?)

  • Kim, Sun-Young;Cho, Byeong-Hoon;Baek, Seung-Ho;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.405-412
    • /
    • 2008
  • This study was aimed to investigate whether an oxygen inhibition layer (OIL) is essential for the interfacial bonding between resin composite layers or not. A composite (Z-250, 3M ESPE) was filled in two layers using two aluminum plate molds with a hole of 3.7 mm diameter. The surface of first layer of cured composite was prepared by one of five methods as followings, thereafter second layer of composite was filled and cured: Group 1 - OIL is allowed to remain on the surface of cured composite; Group 2 - OIL was removed by rubbing with acetone-soaked cotton; Group 3 - formation of the OIL was inhibited using a Mylar strip; Group 4 - OIL was covered with glycerin and light-cured; Group 5 (control) - composite was bulk-filled in a layer. The interfacial shear bond strength between two layers was tested and the fracture modes were observed. To investigate the propagation of polymerization reaction from active area having a photo-initiator to inactive area without the initiator, a flowable composite (Aelite Flow) or an adhesive resin (Adhesive of ScotchBond Multipurpose) was placed over an experimental composite (Exp_Com) which does not include a photoinitiator and light-cured. After sectioning the specimen, the cured thickness of the Exp_Com was measured. The bond strength of group 2, 3 and 4 did not show statistically significant difference with group 1. Groups 3 and 4 were not statistically significant different with control group 5. The cured thicknesses of Exp_Com under the flowable resin and adhesive resin were 20.95 (0.90) urn and 42.13 (2.09), respectively.

Development of Device for the Separation between Touch Panel and LCD Module (터치패널과 LCD 모듈 접착면 분리용 장비 개발)

  • Wang, Wenping;Park, Kyoungseok;Shin, Dongwon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.2
    • /
    • pp.31-37
    • /
    • 2015
  • Recently, mobile phones have become necessary tools for everyday life. In this study, a device that can serve as a separation between a touch panel and an LCD module in a mobile phone was devised for mass repair processes at a smaill business. We used a wire cutting method to separate the bonding plate area between the modules. The device is composed of DC motors and stepping motors that can deliver a precise cutting motion. The motor control system is connected by individual control modules to a CAN network. The developed device showed excellent performance at high temperature conditions.

REPORT ON A CASE TREATED WITH LINGUAL MULTIBRACKET APPLIANCE

  • Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.26 no.6
    • /
    • pp.705-715
    • /
    • 1996
  • The lingual multibracket appliance was developed to overcome the unesthetic nature of traditional fixed orthodontic labial appliances; however, treatment with this appliance was regarded as very difficult as well as a time-consuming. Recently, these problems have been reduced because of advances in lingual bracket systems, improved indirect bonding technique and the development of more flexible wires. There has been a marked increase in the number of adults desiring orthodontic treatment over recent years and many of these patients tend to seek invisible orthodontic appliances due to esthetic reasons. Although the lingual multibracket treatment is not ideal, this form of treatment is currently the best option for the patients with esthetic concerns. Here, I would like to present a case treated successfully with lingual multibracket appliance.

  • PDF

Theoretical Study of Trioxane Derivatives as Amphi-ionophores: Importance of Charge-Dipolar Moiety Orientation

  • Cho, Seung Joo
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.9
    • /
    • pp.2723-2725
    • /
    • 2014
  • Recently we have reported a novel class of anion receptors which are based on 2n-crown-n topology. Trioxane derivatives are capable of anion sensing through pure aliphatic C-H hydrogen bonding. In this work, we highlight another interesting property, i.e., they can also recognize cations as normal crown ethers (3n-crown-n topology). Since the same functional moiety can recognize anions and cations, these coronands are predicted to be amphi-ionophores. However, we could not detect cations even in the gas phase. Considering trioxane is analogous to [$1_6$]starand, this was rather counter-intuitive. The calculation results show that these coronands can detect alkali metals with very low affinity. The low affinity toward cations should be responsible for this failure of experimental detection. With careful theoretical study, we found that this low affinity toward cations could be explained by the unfavorable charge-dipolar moiety orientations as proposed by Cui et al. As in the case of [$1_6$]starand, this is an example that underscores the importance of charge-dipolar moiety orientation in supramolecular interactions.