• Title/Summary/Keyword: scattered ray

Search Result 215, Processing Time 0.022 seconds

A Study on external and internal morphology and pattern analysis in 4 kinds of Mok-Hyaeng Radix (4종류 목향류(木香類)의 외부(外部) 및 내부형태(內部形態)와 이화학패턴연구)

  • Kim, Hong-Jun;Kang, Kyoung-Sik;Choi, Go-Ya;Kim, Ho-Kyung;Jeong, Seung-Il;Ju, Young-Sung
    • Korean Journal of Oriental Medicine
    • /
    • v.12 no.3 s.18
    • /
    • pp.117-130
    • /
    • 2006
  • The purpose of this study was to introduce the differential standard of Mok-Hyaeng Radix species. We established the classificatory standard according to the external and internal morphology and the pattern in 4 kinds of Mok-Hyaeng Radix. The results follow: 1. On the external morphology, Radix of Vladimiria souliei had a sticky material in the head of roots and it was yellowish white in the cut surface. It attached to teeth during chewing. Radix of Aucklandia lappa (=Saussurea lappa) was dark grayish brown and was grayish brown in the cut surface. It had special odor and was not attache to teeth chewing it. On the other hand, Radix of Inula helenium was dark brown. In the cut surface, cortical layer was different from wood layer. Radix of Aristolochia contorta was yellowish brown. In the cut surface, it was not smooth and cortical layer was different from wood layer. 2. On the internal morphology, Radix of Vladimiria souliei had many fascicular fibers and scattered large oil chambers in the bast ray, xylem ray, and parenchyma. On Radix of Aucklandia lappa (=Saussurea lappa), it was difficult to find out the trace when the cork layer was exfoliated. The cambium formed circle and the large oil chambers were scattered in the phloem and xylem. On the other hand, external cortical layer of Radix of Inula helenium was detached and cambium was formed to indistinct circle and large oil chambers were scattered in the phloem and xylem. On Radix of Arustolochia contorta, the large oil chambers were scattered in the surface later, bast part was relatively broad and cambium formed circle. 3. On the TLC pattern, Radix of Aristolochia contorta, Inula helenium, Aucklandia lappa, and Vladimiria souliei were chromogenic to violet and purple according to sulfuric acid colour pattern, especially faint on Aristolochia contorta. 4. On the pattern analysis of HPLC, we compared the content and the pattern of constunolide and dehydrocostus lactone, Radix of Aucklandia lappa was similar to Radix of Vladimiria souliei and Radix of Aristolochia contorta was similar to Radix of Inula helenium. On the total HPLC component pattern, constunolide and dehydrocostus lactone were similar in all four types, but it showed the Rf 5-6 peak was only in Radix of Aristolochia contorta, not in Radix of Inula helenium, Aucklandia lappa, and Vladimiria souliei. It is considered the results of this study will be furnished the basis to succeeding studies and it is needed to extensive comparative study for the same genus-degree of relatedness.

  • PDF

Measurement of Comparison to Scattering Dose Space According to the Presence or Absence of Protective Clothing in the X-ray Room (X선 촬영실에서 방호복 유무에 따른 공간산란선량의 측정 비교)

  • Heo, Ye-Ji;Kim, Kyo-Tae;Cho, Chang-Hoon;Kang, Su-Man;Park, Ji-Koon;Kang, Sang-Sik;Noh, Si-Cheul;Jung, Bong-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.313-320
    • /
    • 2012
  • Current medical institutions with the development of medical technology to the increased demand for health use of radiation equipment is increasing rapidly. Direct radiation from the patient receives the aim of reducing exposure as much as possible is important and the spatial dose of scattered radiation with in the space to engage in reducing healthcare physician, radiation workers and carers need to reduce indirect exposure. X-ray radiation workers and caregivers in the X-ray room to wearing of protective clothing is advised. However Radiation worker sand caregivers of patients with secondary is done, by wearing protective clothing to wear protective clothing because of the weight and discomfort have been neglected. In this study, based on the presence or absence of clothing scattered radiation from space to measure distances, depending on the horizontal and height by measuring the angle of the importance of wearing protective clothing were investigated.

Reduction of Radiation Exposure Dose of Eyeball and Thyroid for Chest and Abdomen CT Scan (흉부 및 복부 CT 검사 시 안구와 갑상선의 방사선 피폭선량 저감)

  • Lee, Jun Seok;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.147-151
    • /
    • 2019
  • In chest and abdomen CT scans, the radiation exposure doses by scattering lines were measured at the eyeball and thyroid. Radiation exposure was investigated by using shielding devices. The chest and abdomen CT scan protocols used in the real examination were applied to measure and compare radiation doses before and after the use of shielding devices at the eyeball and the thyroid. The radiaton doses were measured with OSLD dosimeters. Barium, tungsten sheets, goggles and neck shields were used to protect the scattered X-ray. The chest CT scans showed respectively 3.01 mSv and 6.21 mSv at the eyeball and the thyroid by the scattered X-ray. The abdomen CT scans showed 0.55 mSv and 3.22 mSv for the eyeball and the thyroid respectively. Barium and tungsten sheets had 11% to 13% protection rates at the eyeball and the thyroid for chest CT scan, and 34% to 49% reduction in radiation dose for the abdomen CT scan. Because of the significant radiation dose, which causes cataracts and thyroid cancer by the repeated and continuous radiation exposure, for the chest and the abdomen CT scans, it is required to use shielding devices to reduce radiation dose for examinations.

Shielding Capability Evaluation of Mobile X-ray Generator through the Production assembled Shield (일체형 방어벽 제작을 통한 이동형 엑스선 발생기의 차폐능 평가)

  • Kim, Seung-Uk;Han, Byeoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.895-908
    • /
    • 2018
  • As modern science is developed and advanced, examination and number of times using radiation are increasing daily. General diagnostic X-ray generator is installed on stationary form, But X-ray generator was developed because patient who is in the intensive care unit, operation room, emergency room can not move to general x-ray room. What we examine patient by x-ray generator is certainly necessary, So patient exposure is inevitable. but reducing radiation exposure is highly important matter about radiation technology, guardian, patient in the same hospital room, nurse etc. For this reason, rule regarding safety control of diagnostic x-ray generator revised for radiation worker, patient and protector proclaim that mobile diagnostic x-ray shield must placed in case of examine different location excluding operation room, emergency room, intensive care unit. But, radiogical technologist is having a lot of difficulties to examine with mobile x-ray generator, diagnostic x-ray shield partition, image plate and lead apron. So, when we use x-ray generator, we manufacture shield tools can be attached to the mobile x-ray generator On behalf of x-ray shield partition and conduct analysis and in comparison to part of body and distribution of dose rate and find way to reduce radiation exposure through distribution of dose rate of patient within the radiogical technologist, medical team. Mobile x-ray generator aimed at SHIMADZU inc. R-20, We manufactured equipment for shielding x-ray scattered x-ray by installing shielding wall from side to side based on support beam on the mobile x-ray generator. Shielding wall when moving can be folded and designed to expand when examine. Experiment measured five times in each by an angle for dose rate of eyes, thyroid, breast, abdomen and gonad on exposure condition of upper and lower extremity, chest, abdomen which is examined many times by mobile x-ray generator. We used dosimeter RSM-100 made by IJRAD and measured a horizontal dose rate by body part. The result of an experiment, shielding decreasing rate of the front and the rear showed 77 ~ 98.7%. Therefore using self-production shielding wall reduce scattered x-ray occurrence rate and confirm can decrease exposure dose consequently. Therefore, through this study, reduction result which is used shielding wall of self-production will be a role of shielding optimization and it could be answer about reduction of medical exposure recommended by ICRP 103.

A Study of Tissue-equivalent Compensator for 10MV X-ray and Co-60 Gamma-ray (고에너지 방사선치료용 조직등가보상체에 관한 고찰)

  • CHOI Tae Jin;HONG Young Rak;LIM Charn Soo;JEUNG Ho Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.1 no.1
    • /
    • pp.47-51
    • /
    • 1985
  • Authors describe some useful data when constructing tissue-equivalent compensators which would compensate tissue deficit in the treatment field of high energy electromagnetic radiation Tissue equivalent compensator is made of lucite. The ratio of compensator thickness to the thickness of tissue deficit depends on radiation energy, field size and the distance from the compensator to patient skin. When the compensator is separated from skin surface, the thickness ratio is always smaller than 1.0. This means that the larger the separation, the contribution to the total dose by means of scattered radiation from a tissue equivalent compensator is smaller. Authors propose that the thickness of lucite as tissue equivalent compensator is 0.57 times tissue deficit and the separation between compensator and skin is at least 15m for Co-60 gamma ray and 25cm for 10MV X-ray.

  • PDF

SEPARATION OF GAMMA-RAYS PRODUCTION FROM $^{13}C(p,\;{\gamma})^{14}N,\;^{14}N({\gamma},\;{\gamma})^{14}N$ REACTIONS USING DOPPLER SHIFT EFFECT

  • Kim, Y.K.;Ha, J.H.;Youn, M.;Han, S.H.;Chung, C.E.;Moon, B.S.
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.287-290
    • /
    • 2001
  • The 9.17MeV gamma-rays from the $^{13}C(p,\;{\gamma})^{14}N,\;^{14}N({\gamma},\;{\gamma})^{14}N$ reactions were measured. The incident 9.17MeV gamma-ray was produced from the $^{13}C(p,\;{\gamma})^{14}N$ reaction at Ep=1.75MeV resonance. The 1.75MeV proton beam was accelerated using the 3MV SNU-AMS Tandetron and 1.7MV KIGAM Tandem accelerators. The enriched 13C target was $121{\mu}g/cm^2$ self-supporting foil, and we used liquid nitrogen as a resonant absorption target. We used a HP-Ge detector with 30% efficiency and less 2keV energy resolution. We developed new method to detect the scattered 9.17MeV gamma-ray from the nitrogen target by using the energy difference between the Doppler shifted gamma-ray from the $^{13}C(p,\;{\gamma})^{14}N$ reaction and the resonant absorbed and rescattered gamma-ray from the $^{14}N({\gamma},\;{\gamma})^{14}N$ reaction.

  • PDF

Structure and Identification of Ancient Wood (I) -Construction Wood of Yi-dynasty m Jeju Province- (고재(古材)의 구조(構造)와 수종식별(樹種識別)(제(第) 1 보(報)) -제주도지방(濟州道地方)에 있어서 조선시대(朝鮮時代)의 목조건축재(木造建築材)-)

  • Park, Sang-Jin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.15-23
    • /
    • 1978
  • This report observed for anatomical structure and identified species of small wood debris collected at Chungi-Hyankyo, Yunbuk-Chung, Jeju-Hyankyo, Teachung-Hyangkyo and Kwanduk-Chung in Jeju province constructed in a central period of Yi-dynasty, and now named as local cultral assets. 1. Sample of Chungi-Hyangkyo is gymnosperm with window-like pit, axial and radial cannal & dentate ray tracheid. This sample with identified with Pinus densiflora or Pinus thunbergii. 2. Samples of Yunbuk-Chung and Jeju-Hyangkyo are diffuse porous wood having small vessels with scalariform perforation plates scattered almost equally in annual ring, possess heterogenus ray parenchyma & banded apotracheal parenchyma. This sample is identified with Distylium racemosum. 3. Sample of Teachung-Hyangkyo is ring porous wood composed of big vessels of pore zone and compound vessels outside pore zone. It also has simple perforation plates, tylosis, homogenlls uniseriate ray parenchyma & diffuse parenchyma This sample is identified with Castanopsis cuspidata. 4. Sample of kwanduk-Chung is ring porous wood composed of big vessels of pore zone and compound vessels outside pore zone. It has simple perforation plates, heterogenus ray parenchyma, crystal, vasicentric parenchyma. This sample is identified with Zelkova serrata.

  • PDF

Analysis of Scattering Characteristics by the Double Impedence Wedge (두 개의 임피던스 ?지에 의한 산란 특성 해석)

  • 서용원;장정민이민수이상설
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.363-366
    • /
    • 1998
  • High frequency scattered fields by a double impedence wedge are computed. In the procedure of the computation, arbitrary impedence faces and wedge angles are considered. The diffraction coefficients for the single, double and triple diffraction mechanism are founded. The second-order and third-order diffracted fields are approximated via the extended spectral ray method and the modified Pauli-Clemmow method of the steepest descent. The maliuzhinets function which is very difficult to obtain accurate value is approximated by the Volakis's asymtotic expression. Numerical computations are performed for the various wedge angles and surface impedence values.

  • PDF

A Dynamically Segmented DCT Technique for Grid Artifact Suppression in X-ray Images (X-ray 영상에서 그리드 아티팩트 개선을 위한 동적 분할 기반 DCT 기법)

  • Kim, Hyunggue;Jung, Joongeun;Lee, Jihyun;Park, Joonhyuk;Seo, Jisu;Kim, Hojoon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.8 no.4
    • /
    • pp.171-178
    • /
    • 2019
  • The use of anti-scatter grids in radiographic imaging has the advantage of preventing the image distortion caused by scattered radiation. However, it carries the side effect of leaving artifacts in the X-ray image. In this paper, we propose a grid line suppression technique using discrete cosine transform(DCT). In X-ray images, the grid lines have different characteristics depending on the shape of the object and the area of the image. To solve this problem, we adopt the DCT transform based on a dynamic segmentation, and propose a filter transfer function for each individual segment. An algorithm for detecting the band of grid lines in frequency domain and a band stop filter(BSF) with a filter transfer function of a combination of Kaiser window and Butterworth filter have been proposed. To solve the blocking effects, we present a method to determine the pixel values using multiple structured images. The validity of the proposed theory has been evaluated from the experimental results using 140 X-ray images.