• 제목/요약/키워드: scatter radiation

검색결과 125건 처리시간 0.025초

흉부 전·후방향 검사 시 고관전압 및 산란선 후처리 소프트웨어 적용이 화질과 선량에 미치는 영향 (Effect of High Tube Voltage and Scatter Ray Post-processing Software on Image Quality and Radiation Dose During Chest Anteroposterior Radiography)

  • 김종석;주영철;이승근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권4호
    • /
    • pp.295-300
    • /
    • 2021
  • This study aims to present new chest AP examination exposure conditions through a study on the effect on image quality and patient dose by applying high tube voltage and scatter ray post-processing software during chest AP examination in digital radiography equipment. This study was used a human body phantom and in the chest AP position, the dosimeter was placed horizontally at the thoracic spine 6. The experiment was conducted by dividing into a low tube voltage (70 kVp, 400 mA, 3.2 mAs) group and a high tube voltage (100 kVp, 400 mA, 1.2 mAs) group. The collimation size (14″× 17″) and the source to image receptor distance(110 cm) were same applied to both groups. Radiation dose was presented to dose area product and entrance surface dose. Image quality was compared and analyzed by comparing the difference between the signal-to-noise ratio and the contrast-to-noise ratio of the image according to the application of the scatter ray post-processing software under each condition. The average value of the entrance surface dose in the low and high tube voltage conditions was 93.04±0.45 µGy and 94.25±1.51 µGy, which was slightly higher in the high tube voltage condition, but the dose area product was 0.97±0.04 µGy and 0.93±0.01 µGy. There was a statistically significant difference in the group mean value(p<0.01). In terms of image quality, the values of the signal-to-noise ratio and the contrast noise ratio were higher in the high tube voltage than in the low tube voltage, and decreased when the scattering line post-processing function was used, but the contrast resolution was improved. If there is a scatter ray post-processing function during chest AP examination, it is helpful to actively utilize it to improve the image quality. However, when this function is not available, I thought that applying a higher tube voltage state than a low tube voltage state will help to realize images with a large amount of information without changing the dose.

Recent progress in the theoretical understanding of relativistic electron scattering and precipitation by electromagnetic ion cyclotron waves in the Earth's inner magnetosphere

  • Lee, Dae-Young
    • Journal of Astronomy and Space Sciences
    • /
    • 제36권2호
    • /
    • pp.45-60
    • /
    • 2019
  • The Earth's outer radiation belt has long received considerable attention mainly because the MeV electron flux in the belt varies often dramatically and at various time scales. It is now widely accepted that the wave-particle interaction is one of the major mechanisms responsible for such flux variations. The wave-particle interaction can accelerate electrons to MeV energies, explaining the observed flux increase events, and can also scatter the electrons' motion into the loss cone, resulting in atmospheric precipitation and thus contributing to flux dropouts. In this paper, we provide a review of the current state of research on relativistic electron scattering and precipitation due to the interaction with electromagnetic ion cyclotron (EMIC) waves in the inner magnetosphere. The review is intended to cover progress made over the last ~15 years in the theory and simulations of various issues, including quasilinear resonance diffusion, nonlinear interactions, nonresonant interactions, effects of finite normal angle on pitch angle scattering, effects due to rising tone emission, and ways to scatter near-equatorial pitch angle electrons. The review concludes with suggestions of a few promising topics for future research.

3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가 (Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT))

  • 김진수;이재성;이병일;이동수;정준기;이명철
    • 대한핵의학회지
    • /
    • 제38권4호
    • /
    • pp.318-324
    • /
    • 2004
  • 목적: Philips GEMINI PET/CT 스캐너는 GSO 섬광결정을 사용해 제작된 전신용 PET/CT 스캐너이다. 이 연구에서는 NEMA에서 새롭게 제안한 NEMA NU2-2001에 따라 GEMINI PET/CT 스캐너의 공간분해능, 민감도, 산란분획, NECR 등을 평가하고 그 결과를 BGO, LSO등의 섬광결정의 특성과 비교하였다. 대상 및 방법: GEMINI는 Philips ALLEGRO PET과 MX8000 D multi-slice CT 스캐너를 결합한 PET/CT 스캐너로서 검출기는 GSO 섬광결정 ($4{\times}6{\times}20mm^3$)을 사용하였고 축방향 시야는 18 cm이다. 공간분해능. 민감도, 산란분획, NECR 등을 평가하기 위하여 PET 데이터를 획득하였다(동시계수창: 8 ns, 에너지창: $409{\sim}664$ keV). 공간분해능 측정을 위하여 축횡단면의 중심에서 1 cm, 10 cm 떨어진 지점의 각 3지점((a) x=0, y=1, (b)x=10, y=0, (c)x=0, y=10)에서 영상을 획득한 다음 여과후역투사방법(램프필터 사용)과 3D RAMLA를 이용하여 영상재구성을 하고 FWHM을 구하였다. 민감도 측정을 위하여 선선원(F-18)을 축횡단면의 중심과 중심에서 10 cm 벗어난 지점에서 5개의 알루미늄관을 차례로 씌워 매질감쇠에 따라 달라지는 참계수를 구하고 이 값을 회귀분석하여 감쇠매질이 없는 이상적인 상황에서의 민감도를 측정하였다(랜덤계수가 참계수의 1%이내). 산란분획과 NECR을 측정하기 위하여 F-18 선선원(1110 MBq)을 산란팬텀에 주입하여 7반감기동안 계수를 획득하였다. SSRB을 사용하여 3D 데이터를 재구성한 다음 랜덤계수율이 참계수율이 1% 미만인 영역에서 산란분획을 구하고 각 횡단면의 값을 평균하여 전체 산란분획을 얻었다. 이 값을 기초로 각 프레임, 각 횡단면에 대한 랜덤계수율, 산란계수율, NECR을 구하였다. 결과: 스캐너의 중심에서 1 cm 벗어난 지점에서 횡축방향, 축방향 공간분해능은 (1) 5.3, 6.5 mm (FBP), (2) 5.1, 5.9 mm (3D RAMLA)이었다. 횡단면의 중심에서 10 cm 벗어난 지점에서 횡축반경방향, 횡축접선방향, 축방향 공간분해능은 (1) 5.7, 5.7, 7.0 mm (FBP), (2) 5.4, 5.4, 6.4 mm (3D RAMLA)이었다. 감쇠매질이 없는 이상적인 상황에서의 민감도는 횡단면의 중심에서 3,620 counts/sec/MBq, 횡단면의 중심에서 10 cm 벗어난 지점에서 4,324 counts/sec/MBq이었다. 산란분획은 40.6%, 최대 참계수율과 최대 NECR은 각각 88.9 kcps @ 12.9 kBq/mL, 34.3 kcps @ 8.84 kBq/mL이었다. 결론: 이 실험에서 NEMA NU2-2001을 이용해 GSO 섬광결정을 사용해 제작된 PET/CT에 대한 성능 평가를 실시하였다. 이는 BGO, LSO 섬광결정을 사용해 제작된 PET 스캐너의 특성과 비교할 수 있는 자료를 제공하며 PET 영상 획득 시 객관적 평가와 분석에 유용하였다.

뇌혈관 중재적시술에 있어 측방향 차폐체를 이용한 시술자 피폭 선량 저감화 방법 연구 (Reducing Radiation Exposure Dose on Operator by Using Lateral Protection in Neuro-Intervention)

  • 김종덕;안병주;이준행
    • 한국방사선학회논문지
    • /
    • 제8권1호
    • /
    • pp.1-10
    • /
    • 2014
  • 양방향 뇌혈관촬영기는 하나의 선원에서 방사선이 나오는 것이 아니라 정방향과 측방향에서 방사선 피폭이 이루어지기 때문에 방사선 관계종사자의 피폭이 더욱 많아질 수밖에 없다. 따라서 환자가 받는 선량도 중요하겠지만 시술을 시행하고 있는 방사선 관계종사자 역시 피폭선량을 줄일 수 있는 방법에 대해 많은 관심을 보이고 있다. 본 연구의 목적은 양방향 뇌혈관촬영기의 혈관검사 및 중재적방사선시술에 있어 X-선 관구에서 직접 조사되는 1차 방사선, 정방향관구와 측방향 검출기사이에서 발생하는 1차 산란방사선, 상대적으로 적지만 촬영실 벽이나 바닥에서 반사되는 2차 산란방사선 발생을 간과하지 않을 수 없기에 기존의 일반적인 차폐방법인 천정형 차폐, 테이블형 차폐방법에서 보다 더 적극적인 차폐방법인 측방향 차폐체의 방어용구를 설치하여 시술자가 받는 직접방사선 및 산란방사선에 의한 피폭선량을 최대한 줄이고자 노력하였다. 그 결과 투시측정에서는 생식샘 약 3.64배, 갑상샘 약 3.13배, 눈 약 4.42배 정도 더 감소하였고, 디지털 감산 혈관조영측정에서는 생식샘 약 4.98배, 갑상샘 약 3.00배, 눈 약1.67배의 피폭선량 감소효과를 얻어내었다. 결론적으로 양방향 뇌혈관촬영기의 혈관검사 및 중재적방사선시술시 설치하였던 측방향 차폐체의 방어용구는 일반적인 차폐방법보다 시술자의 피폭선량을 감소시키는데 많은 효과를 주었다고 사료된다.

선형가속기의 6MV X선에 대한 소형조사면의 선량측정 (Dose Characteristics of Small Radiation Fields for 6MV X-ray of Linear Accelerator)

  • 최태진;김옥배;김영훈;손은익;김인홍
    • Radiation Oncology Journal
    • /
    • 제7권2호
    • /
    • pp.287-291
    • /
    • 1989
  • Radiation dosimetry has been extended to small fields less than $4\times4cm^2$ which may be suitable for irradiation of small intracranial tumors. Special consideration was given to the percentage depth dose and scatter correction factors with 0.14ml ion chamber, film dosimetry and TLD measurement. Calculated dose distributions were compared with measured data.

  • PDF

Computation of daily solar radiation using adaptive neuro-fuzzy inference system in Illinois

  • Kim, Sungwon
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.479-482
    • /
    • 2015
  • The objective of this study is to develop adaptive neuro-fuzzy inference system (ANFIS) model for estimating daily solar radiation using limited weather variables at Champaign and Springfield stations in Illinois. The best input combinations (one, two, and three inputs) can be identified using ANFIS model. From the performance evaluation and scatter diagrams of ANFIS model, ANFIS 3 (three input) model produces the best results for both stations. Results obtained indicate that ANFIS model can successfully be used for the estimation of daily global solar radiation at Champaign and Springfield stations in Illinois. These results testify the generation capability of ANFIS model and its ability to produce accurate estimates in Illinois.

  • PDF

adaptive neuro-fuzzy inference system;daily solar radiation;Illinois;limited weather variables;

  • Kim, Sungwon
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.483-486
    • /
    • 2015
  • The objective of this study is to develop generalized regression neural networks (GRNN) model for estimating daily solar radiation using limited weather variables at Champaign and Springfield stations in Illinois. The best input combinations (one, two, and three inputs) can be identified using GRNN model. From the performance evaluation and scatter diagrams of GRNN model, GRNN 3 (three input) model produces the best results for both stations. Results obtained indicate that GRNN model can successfully be used for the estimation of daily global solar radiation at Champaign and Springfield stations in Illinois. These results testify the generation capability of GRNN model and its ability to produce accurate estimates in Illinois.

  • PDF

건식분말화 장치설계를 위한 $U_3O_8$ 분말의 미세입자 유동해석 (Analysis on the flow of $U_3O_8$ powder for design of the voloxidizer)

  • 김영환;정재후;홍동희;윤지섭
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.454-457
    • /
    • 2005
  • Voloxidizer for hot cell demonstration that handle spend fuel of high radiation virulence in limited space should become a small size and not scatter in its exit. This study determine optimum velocity of $U_3O_8$ using Newton-Raphson Method. We have conducted fortran programing on the Newton-Raphson Method, obtained a theory results and, predicted optimum velocity on the particle size distribution of $U_3O_8$. We have conducted experimentation using acrylic experimental device for verification of theory method, sampled and analyzed using the particle size analyzer In the results, we have found maximum $5\~7\%$ error rate in the comparative value of theory and experimentation. Optimum velocity and experimental results of $U_3O_8$ for scatter prevention have applied for design of demonstration voloxidizer, and produced operation condition of voloxidizer.

  • PDF

모의치료(Simulation) 영상을 이용한 Broad-beam CT 영상 구현 (The Broad-beam CT Image Reconstruction from Simulator Images)

  • 이병용
    • Radiation Oncology Journal
    • /
    • 제16권1호
    • /
    • pp.81-86
    • /
    • 1998
  • 목적 : Broad-beam Simulator-CT 개발을 위한 예비연구로서 통상의 모의 치료 영상에서 축상면, 시상면, 관상면 영상을 구현하려 하였다. 대상 및 방법 : 120kVp, 2mAs 동일 조건에서 갠트리 각도를 $4^{\circ}$ 간격으로 90장의 필름을 얻어 입체적인 Filtered back-projection을 시도하였다 외곽선을 찾아 제거하였고, 산란선 성분을 Deconvolution 방법으로 제거하여 좋은 영상을 얻도록 하였다. 결과 : 이 방법으로 축상면, 시상면, 관상면 영상을 얻었으며 각 방향에 대해 동일한 분해능을 갖았다. 그러나 영상의 질은 대단히 나빴다. 결론 : Broad-beam으로 된 CT 영상을 구현할 수 있었다. 이를 위하여 산란선 성분의 Deconvolution이 필요하였으며, 입체적인 back-projection을 실시하였으므로 축상, 시상, 관상 모든 방향에 대해 동일한 분해능을 갖고 있어서 DRR 등 Simulator-CT에 응용할 수 있음을 알 수 있었다. 그러나 실용적인 임상응용을 위해서는 영상의 질 개선이 필요하였다.

  • PDF

중재적 시술 시 팬텀을 이용한 환자의 피폭선량 분석 (TA Study on Patient Exposure Dose Used the Phantom for Interventional Procedure)

  • 강병삼;동경래
    • 대한디지털의료영상학회논문지
    • /
    • 제13권2호
    • /
    • pp.71-76
    • /
    • 2011
  • Because interventional procedure operates looking at premier as real time when perate intervention enemy, by patient is revealed during suitableness time in radiation, side effect such as radiation injury of skin is apt to happen. It established by purpose of study that measure exposure dose that patient receives about these problem, and find solution for radiation injury and repletion method. In this study, we used Rando phantom of identical structure with the human body which becomes accomplished with 4 branch ingredient of the attempt and system equivalent material them and absorbed dose were measured by TLD. According to the laboratory, it shows that operations such as TFCA procedure or uterine myoma embolization are more dangerous than TACE procedure. If both operations are inspected during a short time, it is not affected in being bombed. However, it can lead to palliative agenesis or depilate, definitive agenesis only if operations are repeated more than three times. Dose distibution based on experiment, to reduce radiation exposure to patients result from reduction of scatter ray as we control field size of radiation and protection of side organs except for tumor. also we knew that we can protect patients form radiation exposure, if we increas SOD and decrease SID.

  • PDF