Constructing a Automatic Real-time Line-Scan Inspection System (실시간 자동 검사를 위한 라인 스캔 컴퓨터 비전 시스템의 연구)

  • Jang, Dong-Sik;Kim, Yong-Deok
    • IE interfaces
    • /
    • v.9 no.1
    • /
    • pp.73-82
    • /
    • 1996
  • The purpose of this research is to construct real-time image acquisition system for a line-scan inspection system as a computer vision system. To construct the line-scan inspection system, many problem arise. However, problems of image acquisitions using linear CCD are practically studied in this paper. These problems are concerned to proper lighting systems, relations with handling system, camera systems, and impacts due to the noise of environment. These problems are examined separately, and proper configurations for each case are suggested to construct the line-scan image acquisition system.

  • PDF

A Study On Temperature Changes In Thigh According To Diagnostic Ultrasonography Scan Time (진단용 초음파 검사시간에 따른 허벅지의 온도 변화에 관한 고찰)

  • Kim, Ji-Won;Lim, Hyun-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.3
    • /
    • pp.201-206
    • /
    • 2012
  • Effect of prenatal ultrasound diagnosis have serious damage for the possibility has been reported very low. Long time ultrasound scan can rise the temperature in body tissues and affect the physical. Changes in body temperature have been studied with ultrasound scan time. Fetal ultrasonography were evaluated without the influence of time. The findings, ultrasound scan time in 40 minutes the temperature was reduced. 50 minute tissue temperature rose more than $1^{\circ}C$. If within 40 minutes of ultrasound to be safe guess

Usefulness of Audio-visual Methods that is used to Customer to Help Smooth Public Prosecutor at CT Examination (CT Scan Positioning시 고객의 검사진행의 이해를 돕기 위한 시청각 자료의 유용성)

  • Ahn, Hyeong-Taek;Jeon, Jung-Keun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.2
    • /
    • pp.17-22
    • /
    • 2008
  • It is to improve customer satisfaction measurement and CT Scan process without delay of examination time when is using Scan positioning time(Planning time) that time is happened always between research reactor CT examination to increase fear and examination satisfaction by the customer's comprehension tribe which get the latest contrast enhancement CT examination. Needs and interests that customer wants to compose visual and auditory Contents to be played to Scan positioning time did questionnaire about curiosity later before CT examination to 600 people for October - November 2 months of 2006 to customer whole that get CT examination on source. Data getting through questionnaire investigated examination comprehension and satisfaction through questionnaire after experiment Scan Positioning to 500 coming to help customers to be source CT examination for 3 months February December - 2007 year in 2006 manufacturing Voice and Visual announce media for reference. To customer who interest degree appeared, and answers preparatory audit from preparatory audit about curiosity of CT examination customer to order of examination time required(43%), contrast media side effect(26%), examination region(20%), breath(10%), etc..(1.5%) audio-visual materials in questionnaire that attain after do reclamation among examination age, sex, reception type of irrelatively in 91% of target increase of hailing degree and examination satisfaction appear. Searched that customer hailing and satisfaction are increased greatly when use of audio-visual materials in satisfaction result that use CT Positioning delay time. In experiment process, It took lacking part by method that use hearing in case of do not use sight as is unavoidable in subject position or old age. Through this, audio-visual materials could analogize that it is more useful method that use sight and hearing at the same time.

  • PDF

The real-time scheduling algorithms based on the Insertion technique and Two-way SCAN technique (삽입기법과 양방향 스캔 기법에 기반한 실시간 디스크 스케줄링 알고리즘)

  • Lee Myung Sub;Park Chang Hyeon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.6B
    • /
    • pp.377-386
    • /
    • 2005
  • Recently, to increase throughput per hour on real-time disk scheduling, a lot of algorithms that apply SCAN technique to EDF(Earliest Deadline First) that is representative real-time disk scheduling algorithm are studied. However, existing disk scheduling algorithms have several limitations because they consider continuous I/O requests when create SCAN group. Also, because SCAN technique was fixed direction, the existing algorithms have shortcoming that there are a lot of time damages. This paper proposes a new real-time disk scheduling algorithm based on the insertion technique and the two-way SCAN technique to solve the problems of the exiting real-time disk scheduling algorithms in hard real-time system. The simulation result shows that, when using our techniques, the disk throughput and the number of serviceable I/O requests are enhanced.

Design of High-Speed Image Processing System for Line-Scan Camera (라인 스캔 카메라를 위한 고속 영상 처리 시스템 설계)

  • 이운근;백광렬;조석빈
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.2
    • /
    • pp.178-184
    • /
    • 2004
  • In this paper, we designed an image processing system for the high speed line-scan camera which adopts the new memory model we proposed. As a resolution and a data rate of the line-scan camera are becoming higher, the faster image processing systems are needed. But many conventional systems are not sufficient to process the image data from the line-scan camera during a very short time. We designed the memory controller which eliminates the time for transferring image data from the line-scan camera to the main memory with high-speed SRAM and has a dual-port configuration therefore the DSP can access the main memory even though the memory controller are writing the image data. The memory controller is implemented by VHDL and Xilinx SPARTAN-IIE FPGA.

Real-Time PCB Inspection System using the Line Scan Camera (Line Scan Camera를 이용한 실시간 PCB 검사 시스템)

  • 하종수;이영아;이영동;최강선;고성제
    • Proceedings of the IEEK Conference
    • /
    • 2002.06d
    • /
    • pp.81-84
    • /
    • 2002
  • This paper presents the real-time PCB(Printed circuit board) inspection system that can detect thin open/short error using the line scan camera. After a overall introduction of our system, the outline of our inspection methods are described. The goal of our inspection system is the real time and detailed inspection using the line scan camera. To perform inspection processing in real-time, we utilize double buffering structure. In order to solve the problem of unexpectable pixels of PCB, we propose melting process which eliminates unexpectable pixels of PCB. The design and development of our prototype of PCB ins- pection system is discussed and test results are presented to show the effectiveness of the developed inspection algorithm.

  • PDF

Efficient Test Data Compression and Low Power Scan Testing in SoCs

  • Jung, Jun-Mo;Chong, Jong-Wha
    • ETRI Journal
    • /
    • v.25 no.5
    • /
    • pp.321-327
    • /
    • 2003
  • Testing time and power consumption during the testing of SoCs are becoming increasingly important with an increasing volume of test data in intellectual property cores in SoCs. This paper presents a new algorithm to reduce the scan-in power and test data volume using a modified scan latch reordering algorithm. We apply a scan latch reordering technique to minimize the column hamming distance in scan vectors. During scan latch reordering, the don't-care inputs in the scan vectors are assigned for low power and high compression. Experimental results for ISCAS 89 benchmark circuits show that reduced test data and low power scan testing can be achieved in all cases.

  • PDF

An Effective Multiple Transition Pattern Generation Method for Signal Integrity Test on Interconnections (Signal Integrity 연결선 테스트용 다중천이 패턴 생성방안)

  • Kim, Yong-Joon;Kang, Sung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.10
    • /
    • pp.39-44
    • /
    • 2008
  • Scan architecture is very effective design-for-testability technique that is widely used for high testability, however, it requires so much test time due to test vector shifting time. In this paper, an efficient scan test method is presented that is based on the Illinois scan architecture. The proposed method maximizes the common input effect via a scan chain selection scheme. Experimental results show the proposed method requires very short test time and small data volume by increasing the efficiency of common input effect.

Establishment of Injection Protocol of Test Bolus for Precise Scan Timing in Canine Abdominal Multi-Phase Computed Tomography

  • Choi, Sooyoung;Lee, In;Choi, Hojung;Lee, Kija;Park, Inchul;Lee, Youngwon
    • Journal of Veterinary Clinics
    • /
    • v.35 no.3
    • /
    • pp.93-96
    • /
    • 2018
  • This study aimed to establish an injection protocol to determine the precise CT scan timing in canine abdominal multi-phase CT using the test bolus method. Three dynamic scans with different contrast injection parameters were performed using a crossover design in eight normal beagle dogs. A contrast material was administered at a fixed dose of 200 mg iodine/kg as a test bolus for dynamic scans 1 and 2, and 600 mg iodine/kg as a main bolus for dynamic scan 3. The contrast materials were administered with 1 ml/s in dynamic scan 1, and 3 ml/s in dynamic scan 2 and 3. The mean arrival time to the appearance of aortic enhancement in dynamic scan 3 was similar to that in dynamic scan 2, and different significantly to that in dynamic scan 1. The mean arrival time to the peak aortic and pancreatic parenchymal enhancement in dynamic scan 3 was similar to that in dynamic scan 1, and different significantly to that in dynamic scan 2. In multi-phase CT scan, a test bolus should be injected with the same injection duration of a main bolus, to obtain the precise arrival times to peak of arterial or pancreatic parenchymal enhancement.

TomoTherapy: Analysis of treatment time and influencing factor (TomoTherapy: 치료 소요시간 및 영향 요인 분석)

  • Son, Jong Gi;Kang, Hyun Sung;Hwang, Chul Hwan;Se, Seung Jeong;Choi, Min Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.119-128
    • /
    • 2017
  • Purpose: The purpose of this study was to measure the average actual treatment time at the time of Tomotherapy treatment. We want to investigate the time required for the procedure in the treatment process that affects the actual treatment time. Patients and Methods: We measured the time required by the procedure in 31 patients who were treated with tomography therapy. Beam-on time, Image registration time, Set-up with scan time and Actual treatment time were measured and stepwise regression analysis was performed. Result: The average treatment time per a patient was 21.44 - 23.92 minutes. Beam-on time, Image registration time, and Set-up with Scan time were the important factors affecting the actual treatment time. The biggest influence was Beam-on time and Registration time was less affected by analysing. Conclusion: The average treatment time per a patient in tomotherapy treatment was $22.68{\pm}3.37$ minutes. The Approximately 21 patients are expected to be treated within 8 hours of regular work time. However, if the treatment is interrupted or the time of the procedure is changed during the treatment process, it affects the schedule of the daily treatment patients and the workload is expected to increase.

  • PDF