• Title/Summary/Keyword: scaling parameter

검색결과 144건 처리시간 0.024초

Nonlinear analysis using load-displacement control

  • Kwon, Young-Doo;Kwon, Hyun-Wook;Lim, Beom-Soo
    • Structural Engineering and Mechanics
    • /
    • 제19권2호
    • /
    • pp.153-172
    • /
    • 2005
  • A new load/displacement parameter method is proposed for the simultaneous control of applied loads and structural displacements at one or more points. The procedure is based on a generalized Riks' method, which utilizes load/displacement parameters as scaling factors to analyze post-buckling phenomena including snap-through or snap-back. The convergence characteristics are improved by employing new relaxation factors through an incremental displacement parameter, particularly in a region that exhibits severe numerical instability. The improved performance is illustrated by means of a numerical example.

토양 수리학적 함수를 이용한 불포화 수리전도도로부터 공극크기분포의 모사 (The Simulation of Pore Size Distribution from Unsaturated Hydraulic Conductivity Data Using the Hydraulic Functions)

  • 윤영만;김정규;신국식
    • 한국토양비료학회지
    • /
    • 제43권4호
    • /
    • pp.407-414
    • /
    • 2010
  • 토양의 공극 크기별 분포는 토양중 수분의 함량과 수분퍼텐셜의 관계를 나타내는 토양수분특성 자료로부터 계산된다. 그러나 기존의 토양수분특성 측정방법들은 교란된 토양을 이용하거나 코어시료를 채취한다 하여도 동역학적으로 변화하는 현장 토양 공극분포를 반영하는 데는 많은 어려움이 있었다. 또한 이러한 토양수분특성 자료를 얻기 위해서는 많은 시간과 노력이 요구되어 왔다. 따라서 본 연구에서는 교란되지 않은 현장 토양에서 측정한 불포화 수리전도도 자료로부터 토양의 공극 크기별 분포 곡선을 추정하는 이론적 체계를 제시하고자 하였다. 이를 위해 Brooks-Corey와 van Genuchten의 수리학적 모델을 이용하여 토양의 불포화 수리전도도 자료로부터 공극의 크기별 분포를 추정하는 이론적 모델을 전개하였으며, 이러한 이론적 모델에 근거하여 Brooks-Corey와 van Genuchten의 soil parameter들의 변화에 따른 불포화수리전도도와 공극 크기별 분포곡선의 모사하였다. 공극크기별 분포곡선의 모사는 토성별 불포화수리전도도 곡선의 scaling factor 역할을 하는 $K_s$를 1.0 cm $h^{-1}$로 설정하고, 수리학적 모델별로 일정한 경계조건 (Brooks-Corey soil parameters, ${\alpha}_{BC}=1-5L^{-1}$, b = 1 - 10; van Genuchten soil parameters, ${\alpha}_{VG}=0.001-1.0L^{-1}$, m = 0.1 - 0.9)에서 수행하였다. Brooks-Corey 모델을 이용한 공극 크기별 분포곡선의 모사에서는 parameter b가 공극분포곡선의 형태에 영향을 주었으며, ${\alpha}_{BC}$는 공극분포곡선의 민감도에 영향을 주었다. 또 van Genuchten 모델을 이용한 공극 크기별 분포곡선의 모사에서는 ${\alpha}_{VG}$가 scaling factor의 역할을 하였으며, parameter m은 공극분포곡선의 형태에 영향을 주었다. 따라서 경계조건 안에서 불포화 수리전도도 자료로부터 공극의 크기별 분포 모사가 가능하였으며, 토양 parameter들이 토성, 입자분포 등의 물리적 특성을 잘 반영하는 경우 이론적으로 현장 토양의 공극 크기별 분포의 추정이 가능할 것으로 판단되었다.

단일 입출력 시스템에 대한 IMC-PID의 새로운 최적 동조법 (New Optimal Tuning Method of IMC-PID for SI/SO Systems)

  • 김창현;임동규
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2008년도 춘계종합학술대회 A
    • /
    • pp.213-217
    • /
    • 2008
  • 본 논문에서는 표준 IMC-PID 제어기에 시스템 식별상의 위상 조절 인자를 설계 변수로 추가함으로 새로운 IMC-PID 제어기 설계 방법을 제안한다. 제안된 제어기의 동조법으로 해석적으로 구해진 주파수 영역 특성을 통해 주파수 영역 성능을 보장하도록 하는 설계 변수의 구속 조건 하에서 시간영역의 적분 오차 지표를 가격함수로 최소화하는 최적 해를 얻는다. 이 제안된 동조법은 다양한 설계 사양을 동시에 고려하도록 하여 기존의 IMC-PID의 단일 설계 변수 동조가 갖는 비유연성 문제를 개선하였다. 사례 연구에서 기존의 동조법들과의 성능 비교를 통해 그 유용성을 검토했다.

  • PDF

Effects of scaling and root planing with or without a local drug delivery system on the gingival crevicular fluid leptin level in chronic periodontitis patients: a clinico-biochemical study

  • Meharwade, Vinayak Venkoosa;Gayathri, Gunjiganur Vemanaradhya;Mehta, Dhoom Singh
    • Journal of Periodontal and Implant Science
    • /
    • 제44권3호
    • /
    • pp.118-125
    • /
    • 2014
  • Purpose: The present split mouth study evaluates the effect of nonsurgical periodontal treatment on the gingival crevicular fluid (GCF) leptin level in chronic periodontitis. Methods: Ninety sites from 30 nonobese chronic periodontitis patients were selected and divided as follows: group I, 30 healthy sites receiving no treatment; group II, 30 periodontitis sites receiving scaling and root planing (SRP); and group III, 30 periodontitis sites receiving SRP with tetracycline local drug delivery. At baseline, after GCF sampling and clinical parameter recording, the assigned treatment was performed for the study groups. During recall visits, GCF sampling followed by clinical parameter recording was done for groups II and III. Results: Reductions in the probing depth and the clinical attachment level (CAL) were highly significant at different time intervals (except between day 0 and 45) in both groups II and III. Upon comparison, group III showed significant gain in CAL between day 0 and 15 and between day 0 and 45. After treatment, the reduction in the GCF leptin level was more significant in group III than in group II at day 15 but re-elevated almost to the pretreatment levels at day 45. Conclusions: Nonsurgical periodontal therapies were not effective in maintaining stable reduction in the GCF leptin level during the study period.

오토스테레오그램을 이용한 워터마킹에서 $\alpha$스켈링 파라미터 최적화 ($\alpha$ Scaling Parameter Optimization On Watermarking Using Autostereogram)

  • 허덕규;이인정;김성옥
    • 인터넷정보학회논문지
    • /
    • 제2권4호
    • /
    • pp.101-109
    • /
    • 2001
  • 최근의 화상 정보와 디지털 화상정보의 사용량은 무한히 커지고 있다. 하지만 이러한 화상정보는 인터넷과 CD-ROM등을 통해 수없이 많은 무단 복사와 저작권 피해 사례가 많이 발생되고 있다. 또한 워터마킹 방법에 의한 원본 데이터의 왜곡과 워터마크 데이터의 사용으로 인한 원본 데이터의 방대성 등의 문제점을 해결하고 검증을 위한 방법들이 여러 가지로 제안되고 있다. 그중 일반적으로 화상정보의 저작권 소유권에 대해서는 워터마킹 방법이 일반적으로 많이 사용되고 있다. 이런 워터마킹 방법은 화상정보의 검증 절차의 복잡성과 계산 량의 증가가 발생하는 경우가 많다. 본 논문에서는 이런 문제점을 해결할 수 있도록 정지 화상정보에 오토스테레오그램(Autosterogram)을 합성하면서 워터마킹 정보의 삽입과 추출에 있어서 발생되는 원 데이터의 변형, 왜곡을 방지하기 위해 삽입되는 정보의 양을 결정하는 scaling 파라미터를 부분적으로 최적화, 워터마크 정보 추출의 최대화, 복원 시 워터마크 정보를 극대화하는 방법에 대해 알아보았다.

  • PDF

C-Sphere Strength-Size Scaling in a Bearing-Grade Silicon Nitride

  • Wereszczak, Andrew A.;Kirkland, Timothy P.;Jadaan, Osama M.;Strong, Kevin T.;Champoux, Gregory J.
    • 한국세라믹학회지
    • /
    • 제45권9호
    • /
    • pp.507-511
    • /
    • 2008
  • A "C-sphere" specimen geometry was used to determine the failure strength distributions of a commercially-available bearing-grade silicon nitride ($Si_3N_4$) with ball diameters of 12.7 and 25.4 mm. Strengths for both diameters were determined using the combination of failure load, C-sphere geometry, and finite element analysis and fitted using two-parameter Weibull distributions. Effective areas of both diameters were estimated as a function of Weibull modulus and used to explore whether the strength distributions predictably scaled between each size. They did not. That statistical observation suggested that the same flaw type did not limit the strength of both ball diameters indicating a lack of material homogeneity between the two sizes. Optical fractography confirmed that. It showed there were two distinct strength-limiting flaw types common to both ball diameters, that one flaw type was always associated with lower strength specimens, and that a significantly higher fraction of the 25.4-mm-diameter C-sphere specimens failed from it. Predictable strength-size-scaling would therefore not result as a consequence of this because these flaw types were not homogenously distributed and sampled in both C-sphere geometries.

Challenges for Nanoscale MOSFETs and Emerging Nanoelectronics

  • Kim, Yong-Bin
    • Transactions on Electrical and Electronic Materials
    • /
    • 제11권3호
    • /
    • pp.93-105
    • /
    • 2010
  • Complementary metal-oxide-semiconductor (CMOS) technology scaling has been a main key for continuous progress in silicon-based semiconductor industry over the past three decades. However, as the technology scaling enters nanometer regime, CMOS devices are facing many serious problems such as increased leakage currents, difficulty on increase of on-current, large parameter variations, low reliability and yield, increase in manufacturing cost, and etc. To sustain the historical improvements, various innovations in CMOS materials and device structures have been researched and introduced. In parallel with those researches, various new nanoelectronic devices, so called "Beyond CMOS Devices," are actively being investigated and researched to supplement or possibly replace ultimately scaled conventional CMOS devices. While those nanoelectronic devices offer ultra-high density system integration, they are still in a premature stage having many critical issues such as high variations and deteriorated reliability. The practical realization of those promising technologies requires extensive researches from device to system architecture level. In this paper, the current researches and challenges on nanoelectronics are reviewed and critical tasks are summarized from device level to circuit design/CAD domain to better prepare for the forthcoming technologies.

서브마이크론 MOSFET의 파라메터 추출 및 소자 특성 (1)

  • 서용진;장의구
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제7권2호
    • /
    • pp.107-116
    • /
    • 1994
  • In the manufacturing of VLSI circuits, variations of device characteristics due to the slight differences in process parameters drastically aggravate the performances of fabricated devices. Therefore, it is very important to establish optimal process conditions in order to minimize deviations of device characteristics. In this paper, we used one-dimensional process simulator, SUPREM-II, and two dimensional device simulator, MINIMOS 4.0 in order to extract optimal process parameter which can minimize changes of the device characteristics caused by process parameter variation in the case of short channel nMOSFET and pMOSFET device. From this simulation, we have derived the dependence relations between process parameters and device characteristics. Here, we have suggested a method to extract process parameters from design trend curve(DTC) obtained by these dependence relations. And we have discussed short channel effects and device limitations by scaling down MOSFET dimensions.

  • PDF

분포형 강우-유출 모형에서 토양도 격자크기 효과가 Green-Ampt 모형의 매개변수와 모의된 강우손실에 미치는 영향 (Impact of Different Green-Ampt Model Parameters on the Distributed Rainfall-Runoff Model FLO-2D owing to Scale Heterogeneity)

  • 황지형;이길하
    • 한국환경과학회지
    • /
    • 제29권1호
    • /
    • pp.15-23
    • /
    • 2020
  • The determination of soil characteristics is important in the simulation of rainfall runoff using a distributed FLO-2D model in catchment analysis. Digital maps acquired using remote sensing techniques have been widely used in modern hydrology. However, the determination of a representative parameter with spatial scaling mismatch is difficult. In this investigation, the FLO-2D rainfall-runoff model is utilized in the Yongdam catchment to test sensitivity based on three different methods (mosaic, arithmetic, and predominant) that describe soil surface characteristics in real systems. The results show that the mosaic method is costly, but provides a reasonably realistic description and exhibits superior performance compared to other methods in terms of both the amount and time to peak flow.

Frequency Scaling을 통한 LSP 파라미터 Fitting에 관한 연구 (A Study on the Fitting of LSP(Line Spectrum Pairs) Parameter using Frequency Scaling)

  • 민소연;배명진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 제14회 신호처리 합동 학술대회 논문집
    • /
    • pp.801-804
    • /
    • 2001
  • LSP 파라미터는 음성코덱(codec)이나 인식기에서 음성 신호를 분석하여 전송형이나 저장형 파라미터로 변환되어, 주로 저전송률 음성부호화기에 사용된다. 그러나 LPC 계수를 LSP로 변환하는 방법이 복잡하여 계산시간이 많이 소요된다는 단점이 있다[1]. 기존의 LSP 변환 방법 중 음성 부호화기에서 주로 사용하는 real root 방법은 근을 구하기 위해 주파수 영역을 순차적으로 검색하기 때문에 계산시간이 많이 소요되는 단점을 갖는다. 본 논문에서 비교 평가한 알고리즘은 첫 번째, 기존의 real root 알고리즘, 두 번째는, LSP 파라미터의 분포 특성을 조사하여 이를 토대로 검객구간의 순서와 검색간격을 달리한 경우, 세 번째는 검색 시 mel scale을 사용한 알고리즘이다. 실험결과, 기존의 real root 방식에 비하여 두 가지 방식 모두가 변환시간의 40% 이상이 감소되는데 반하여 통일한 관을 찾음을 알 수가 있었고, 특히 분포특성을 이용하여 검색순서와 간격조절을 한 경우에 있어서, 기존의 방식보다 40%이상이 감소되었다.

  • PDF