• Title/Summary/Keyword: savings amount

Search Result 148, Processing Time 0.022 seconds

Watermarking of Compressed Video in the Bitstream Domain: An Efficient Algorithm and its Implementation

  • Drobouchevitvh Inna G.;Lim Sung-Jun;Han Byung-Wan;Chang Hang-Bae;Kim Kyung-Kyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.4C
    • /
    • pp.458-471
    • /
    • 2006
  • Digital watermarking of multimedia data is a very active research area that has enjoyed a considerable amount of attention in recent years. In this paper, we propose an algorithm for embedding/detecting a fragile watermark in MPEG-4 compressed video domain (Simple and Advance Simple Profiles). The watermark bits are put directly into Huffman VLC-codespace of quantized DCT domain. The advantage of watermark embedding into the compressed domain is the significant savings for a real-time implementation as it does not require a full decoding operation. The watermark embedding does not change the video file size. The algorithm demonstrates high watermarking capacity, thereby providing reliable foolproof authentication. The results of experimental testing demonstrate that watermark embedding preserves the video quality. Watermark detection is performed without using the original video.

R&D OF FREEZING AND REFRIGERATION SYSTEM USING CHP. (가역 화학 열 펌프(CHP)를 이용한 냉장.냉동 시스템 개발 연구)

  • 이종호;김석종
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.04a
    • /
    • pp.132-135
    • /
    • 1996
  • This study is to develop an ammonia based chemical heat pump(STELF) for a freezing and refrigeration system coupled to gas, fuel and/or waste from industrial processes as heat sources. Recently it has been continually taking a growing interest in chemical heat pumps without electric power and having higher COP's than those of existing compression type refrigeration systems using freon. By introducing STELF technology, efficient heat recovery utilizing enormous amount of waste heat in energy consuming large scale industries or building for their own refrigeration purposes is possible. Moreover, air-conditioning systems coupled to city gas for small scale industries or building can be realized. Therefore, STELF technology can contribute much for overall energy savings and efficient energy management.

  • PDF

The Effectiveness Analysis of the Waste Recycling System of Voluntary Agreements (자발적협약 제도의 폐기물 재활용 효과 분석)

  • Jeong, Jong-Chul
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.1
    • /
    • pp.117-124
    • /
    • 2013
  • The introduction of Extended Producer Responsibility(EPR), voluntary agreements and operating were analyzed in this study. The voluntary agreement to participate in the manufacturers, recyclers and management reporting agency data and literature data to verify through research and analysis assessing the performance of the management plan for this system was analyzed. The effectiveness of Voluntary Agreement(VA) on waste analysis system of voluntary agreements with the voluntary agreement of waste reduction savings exemption amount and reductions in greenhouse gases, such as comparison and understanding of business organizations participate waste recycling effects were verified. The Voluntary Agreements as a means of future regulatory system for the ongoing operation of the waste recycling operations and systems effectiveness analysis of the problems appearing in operators and manufacturers suggest ways to improve it.

Heuristic based Energy-aware Resource Allocation by Dynamic Consolidation of Virtual Machines in Cloud Data Center

  • Sabbir Hasan, Md.;Huh, Eui-Nam
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.8
    • /
    • pp.1825-1842
    • /
    • 2013
  • Rapid growth of the IT industry has led to significant energy consumption in the last decade. Data centers swallow an enormous amount of electrical energy and have high operating costs and carbon dioxide excretions. In response to this, the dynamic consolidation of virtual machines (VMs) allows for efficient resource management and reduces power consumption through the live migration of VMs in the hosts. Moreover, each client typically has a service level agreement (SLA), this leads to stipulations in dealing with energy-performance trade-offs, as aggressive consolidation may lead to performance degradation beyond the negotiation. In this paper we propose a heuristic based resource allocation of VM selection and a VM allocation approach that aims to minimize the total energy consumption and operating costs while meeting the client-level SLA. Our experiment results demonstrate significant enhancements in cloud providers' profit and energy savings while improving the SLA at a certain level.

MODELING OF PRESSURE CONTROL SYSTEM OF BOILER (보일러 풍압 제어 계통의 모델링)

  • Park, Min-Ho;Mok, Hyung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.362-366
    • /
    • 1987
  • The amount of inflowing Air into the boiler has controlled by manipulating the opening of valve, damper and vane, as fan operated by induction motor operats at constant speed, but these control methods are not efficient. Thus VVVf(Variable Voltage Variable Frequency) control of fan has selected to improve efficiency and to acquire power savings. Control system of Air Flow is affected by nonlinearity caused by load variation, vane opening, etc. The analysis of control parameter causing nonlinearity is needed to acquire optimal control and excellent transient response. This paper provides modeling of boiler with various load conditions and vane opening, and analysis of this system.

  • PDF

Cleaner Production Option in a Food (KIMCHI) Industry

  • Choo, Kwang-Ho;Lee, Chung-Hak
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1999.04b
    • /
    • pp.1-12
    • /
    • 1999
  • In Kimchi (a salt-pickled and fermented food) manufacturing industry, the process of brining and rinsing the raw vegetable produces a vast amount of wastewater of high salinity. Instead of expensive and low-efficient conventional treatment system, brining wastewater reuse system was developed using hybrid chemical precipitation / microfiltration. In the microfiltration of chemically treated brining wastewater, comparison of flux, backwashing frequency and energy consumption was made between dead-end and crossflow filtration mode. The optimum location of neutralization step in this system was also discussed in connection with the micro filtration performance. The quality test of Kimchi prepared by the reuse system conformed the new approach was successful in terms of water/raw material (salt) savings and wastewater reduction.

  • PDF

Weight minimum design of concrete beam strengthened with glass fiber reinforced polymer bar using genetic algorithm

  • Rahman, Md. Moshiur;Jumaat, Mohd Zamin;Islam, A.B.M. Saiful
    • Computers and Concrete
    • /
    • v.19 no.2
    • /
    • pp.127-131
    • /
    • 2017
  • This paper presents a generalized formulation for optimizing the design of concrete beam reinforced with glass fiber reinforced polymer bar. The optimization method is formulated to find the design variables leading to the minimum weight of concrete beam with constraints imposed based on ACI code provisions. A simple genetic algorithm is utilized to solve the optimization task. The weights of concrete and glass fiber reinforced polymer bar are included in the formulation of the objective function. The ultimate limit states and the serviceability limit states are included in formulation of constraints. The results of illustrated example demonstrate the efficiency of the proposed method to reduce the weight of beam as well as to satisfy the above requirement. The application of the optimization based on the most economical design concept have led to significant savings in the amount of the component materials to be used in comparison to classical design solutions.

Analysis of Life Cycle Assessment of Renovation Building Through Case Study (리모델링 건축물의 전과정 탄소배출량 사례 평가 분석)

  • Lim, Hyojin;Jang, Hyeongjae;Tae, Sungho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.47-48
    • /
    • 2022
  • In Korea, construction and development has been continued rapidly since the 1970s, and the reconstruction and renovation market has recently been activated to improve old buildings. Most of the environmental evaluation of reconstruction and renovation projects is focused on the use of operating energy, and It is necessary to analyze carbon emissions throughout the life cycle for a comprehensive evaluation of reconstruction and remodeling projects. Therefore, this study quantitatively predicted carbon emissions from reconstruction and renovation based on ISO 14040s through case analysis for the purpose of evaluating the carbon emissions of renovated buildings from the perspective of the whole life cycle. In additional, the amount of carbon savings of each was analyzed through comparison with existing building.

  • PDF

How Much Discrepancy Can Happen from BIM-based Quantity Take?

  • Kim, Seong-Ah;Chin, Sangyoon
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.263-267
    • /
    • 2015
  • Stakeholders of a construction project expect cost savings through fast and accurate cost analysis by performing BIM-based quantity take-off (BQT). However, authors have observed that there can be discrepancies in the results of BQT depending on the level of development (LOD) and modeling methods. In addition, since quantity take-off methods are different depending on the construction work items, the combination of LOD, modeling methods of BIM, features of construction work items can cause serious overestimate or underestimate in BQT results. It is necessary to identify what kind of problems can happen and how those problems can be avoided in various construction work items, since the discrepancy of quantity take-off results has great impact on not only cost analysis but also the determination of contract amount and it can cause claims, poor construction quality, cost overruns, and many others later in the construction project. Therefore, this paper focuses the identification of issues and problems of BQT at each construction work item level based on two categorizations of structural works and interior works.

  • PDF

Analysis on Energy Demand Resulting From the Change in Window Area & Installation of Interior Exterior Blinds (건축물에너지효율등급 기밀시험이 등급에 미치는 영향분석)

  • Kim, Dae-Won;Chung, Kwang-Seop;Kim, Young-Il;Nam, Ariasae;Ju, Jung-Kyeong
    • Journal of Energy Engineering
    • /
    • v.23 no.1
    • /
    • pp.40-45
    • /
    • 2014
  • The ventilation frequency of 0.5 times in residential facilities is applied mandatorily to the housing facilities containing more than 100 house units to improve the indoor air quality and create comfortable interior conditions and pleasantness for residents. The Building Energy Efficiency Rating system requires the implementation of leakage test based on ventilation frequency with the test results being reflected in the efficiency ratings, thereby stimulating the precise construction of the fittings in the periphery of windows and savings of energy that can be lost due to the infiltration air. The inspection results of the Building Energy Efficiency Rating at the site showed that the ventilation frequency was in the range between 0.63 and 0.71 and that the difference was found to have a significant effect on the amount of energy reduction. It is urgent to conduct the study on highly leakage-proof buildings and construction methods, along with the expansion of mandatory leakage-proof diagnosis of non-residential buildings, considering the mandatory ventilation frequency below 0.6 for passive houses under the European standards and the target set by Korea to introduce the passive house, the rigorous standard for energy efficiency in buildings and mitigating their ecological footprint, by 2017 and achieve the zero house by 2025.