• 제목/요약/키워드: sandwich insulation

검색결과 59건 처리시간 0.021초

타설형 콘크리트 중단열 벽체의 요구성능 분석 (Performance Requirement of Cast-in-place Concrete with Sandwich Insulation)

  • 박준호;유정호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.10-11
    • /
    • 2014
  • Energy load of building affected by insulation performance of building's exterior. and insulation system can be classify interior insulation, exterior insulation, sandwich insulation according to install place of insulation. but within interior insulation system, corner wall and the cross outer wall-slab insulation part may occur thermal bridges. And then, within exterior insulation system is more superior insulation performance than interior insulation, but it has difficult to apply, easily broken at high building because of strong wind load. And also difficult to maintenance exterior insulation system. So, in this study, to found requirement performance of cast-in-place sandwich insulation system that is superior insulation performance and easy construction and maintenance. requirement performance of cast-in-place sandwich insulation system is 1) To avoid thermal bridges in the insulation performance, 2) Both sides concrete wall can be composite action in the structural performance. Because of this study, can develops cast-in-place sandwich insulation system and this insulation system contribute to improve insulation performance of apartment-house and high building.

  • PDF

현장타설 중단열 RC벽체의 구조적 성능 (Structural Performance for Sandwich Insulation of Reinforced-Concrete)

  • 박준호;유정호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.19-20
    • /
    • 2015
  • Building exterior wall's energy loss is very high rate comparing to all part of a buildings. And it account for upper 40% of cooling and heating load. So many studies conducted improving insulation performance of building's exterior, appeared about sandwich insulation wall which could be gaining merit of traditional insulation method those are exterior insulation and interior insulation. In this study, we inform structural performance of sandwich insulation wall for RC wall. For this, first, we define each wall's role and design sandwich insulation wall. At last, analyze structural performance of sandwich insulation wall. This study can contribute to apply it safely where side wall which toilet, stair area, etc.

  • PDF

중단열 시스템의 문제점 분석 (Problem Analysis of Sandwich Insulation Wall System)

  • 박준호;유정호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.166-167
    • /
    • 2015
  • Because of energy crisis at all around the world, there is many method and system which for improving energy efficiency has appeared in construction industry. And then, 20% of entire building energy loss is emissed to exterior of buildings, that is important to building's entire energy efficiency. So, many research has been conducted for imporve exterior energy efficiency and generally it called insulation of wall. Method for wall insulation can be classified interior system and exterior system which defined installation place of insulation board whether interior or exterior of structural wall. However, interior system has thermal problem such as thermal-bridge which can be necessarily occur condensation. and exterior system has constructional problem such as difficult to construction because exterior and finish work so expensive construction cost than other insulation method. Thus, sandwich insulation wall system has been appeared for solving these problems. Sandwich insulation system must using wall connecting things because both side walls is divided by center insulation. At this, Through the heat at wall connecter, it can be occured thermal-bridge and broken insulation board when under construction will be bring negative effect by reducing wall thickness and insulation deficit. At this study, we were compared previous sandwich insulation system and analysis these system's problem for develop the improving constructability and performance of sandwich insulation system.

  • PDF

폼타이 종류에 따른 중단열 벽체의 단열성능 평가 (Evaluating Insulation Performance of Form-tie in Sandwich Insulation Wall)

  • 박준호;유정호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.188-189
    • /
    • 2014
  • Nowadays, many research execute about sandwich-insulation wall for durability of wall and retaining insulation performance. But sandwich-insulation, different exterior and interior insulation, need to form-tie which supporting both side form. And because of it penetrate concrete wall, it is worried about thermal-bridge phenomenon to form-tie. So, this research classify penetration type and buried type and analysis thermal-phenomenon of each type's form-tie and insulation performance. As a result, all form-tie type little occur thermal-bridge but penetration form-tie have superior insulation performance and low U-value.

  • PDF

허니컴 샌드위치판의 투과손실 개선에 관한 실험적 연구 (An Experimental study to Improving the Sound Transmission Loss of Honeycomb sandwich Plates)

  • 유영훈;양보석
    • 한국자동차공학회논문집
    • /
    • 제6권2호
    • /
    • pp.92-99
    • /
    • 1998
  • The sound insulation capacity of honeycomb sandwich plates which have relatively higher strength ratios to weight is poorer than those of uniform and another sandwich plates. Therefore, improvement of the sound insulation capacity of the honeycomb sandwich plate which has a meritof lightness is required to use it in automobile and rapid rail road industries. In this study, to improving the sound insulation capacity of the honeycomb sandwich plate, the sound transmission loss of the structure is experimentally investigated by adding a viscoelastic damping layer, The effective add position and thickness of the layer were investigated from the viewpoints of both sound transmission loss and improved sound transmission loss over the frequency range from 800Hz to 10kHz.

  • PDF

EPS Bead와 유리섬유를 혼입한 샌드위치 패널 심재의 단열 특성 (Thermal Insulation Properties of Sandwich Panel Core with EPS Bead and Glass Wool)

  • 전은영;이창우;황우준;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.77-78
    • /
    • 2022
  • To improve the fire vulnerability of the organic insulation sandwich panel core, which is the main culprit of the large-scale fire disaster, an experiment was conducted to examine the thermal conductivity properties of the core material mixed with the organic insulation material EPS Bead and the inorganic insulation material glass wool. As the Additional ratio of glass wool increased, the thermal conductivity decreased, and it was determined that the replacement of glass wool of 3% or more had little effect on the decrease in thermal conductivity. In addition, it can be seen that the most ideal thermal conductivity is exhibited when 1% Replacement ratio of EPS and 3% glass wool are added. The core material of such organic and inorganic insulation materials is judged to be a core material that can compensate for the fire vulnerability of existing insulation materials. Therefore, in order to determine whether it is used as a core material for sandwich panels, additional studies such as fire resistance experiments and sound absorption experiments are needed in the future.

  • PDF

전단연결재를 적용한 무기계 경량기포콘크리트(ALC) 샌드위치 외벽 패널의 단열성능에 미치는 영향요인 분석 (An Analysis of Factors Influencing Insulation Performance of Inorganic Autoclaved Lightweight Concrete Sandwich Wall Panels Using Shear Connectors)

  • 강동화;강동화;신동현;김형준
    • 대한건축학회논문집:구조계
    • /
    • 제34권1호
    • /
    • pp.79-87
    • /
    • 2018
  • The purpose of this study was to analyze factors influencing insulation performance of inorganic Autoclaved Lightweight Concrete(ALC) sandwich wall panels with the application of shear connectors. To analyze the effect of shear connectors on the thermal performance of sandwich wall panels, heat transfer analysis was conducted by using the three-dimensional heat transfer simulation software. Four types of shear connector such as Pin, Clip, Grid, and Truss were selected for insulation performance analysis. Thermal bridge coefficient was calculated by varying typical panel thickness and shear connector thickness and materials such as steel, aluminum, and stainless steel. The results showed that Grid and Truss type widely distributed along the section of sandwich wall panel had a great influence on the thermal bridge coefficient by changing the influence factors. Based on the results of thermal and structural performance analysis, effective heat transmission coefficient of the sandwich wall panel satisfying the passive house insulation criteria was calculated. As a result, it was found that heat transmission coefficient was increased from $0.132W/m^2{\cdot}K$ to $0.141{\sim}0.306W/m^2{\cdot}K$ depending on the shear connector types and materials. In the majority of cases, the passive house insulation criteria was not satisfied after using shear connectors. The results of this study were likely to vary according to how influence factors were set, but it is important to apply the methods that reduce the thermal bridge when there would be a possibility of greatly affecting the insulation performance.

노출콘크리트 중단열 벽체의 단열성능 분석 (Insulation Performance Analysis of Exposed Concrete Sandwich Wall)

  • 여창재;유정호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.105-106
    • /
    • 2016
  • The study of the sandwich wall with the increasing interest in building energy consumption have been actively conducted. This study designed exposed sandwich wall in the light of energy saving design standard and thermal bridge of share connection. The heat insulating performance was analyzed U-fator using calculation program provided in passive houses association and KS F 2277 (method of measuring thermal insulation of construction component materials).

  • PDF

샌드위치 복합소재가 적용된 틸팅 차량의 단열 특성 평가 연구 (Evaluation of the Property of adiabatic Insulation for TTX Train with Sandwich Composite bodyshell)

  • 이상진;오경원;정종철;조세현;서승일
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.251-256
    • /
    • 2005
  • This study was performed the heat transportation ratio of three types of the following sandwich panel by KS F 2278(2003) ; Type ${\sharp}1$ : Carbon/epoxy Aluminum Honeycomb and Balsa Core Sandwich Panel(Thickness : 37mm), Type ${\sharp}2$ : Carbon/epoxy Aluminum Honeycomb Core Sandwich Panel(Thickness : 57mm), and Type ${\sharp}3$ : Carbon/epoxy Aluminum Honeycomb Core Sandwich Panel(Thickness : 37mm). Also was performed the heat transportation of next three types of the following sandwich panel by KS F2277(2002) ; Type ${\sharp}4$ and ${\sharp}5$ : 27mm, and 35mm thick-Aluminum Honeycomb Sandwich Panels, and Type ${\sharp}6$ : 27mm thick-Foaming Aluminum Sandwich Panel. It is the larger area between the skin and core, the heat transportation ratio is the higher, and when it is composed of the hybrid composite structure, good insulation property was shown.

  • PDF

복합자재 콘칼로리미터평가방법에 대한 연구 (A Study on the Cone Calorimeter Evaluation Method of Sandwich Panels)

  • 박정우;조남욱
    • 한국화재소방학회논문지
    • /
    • 제31권6호
    • /
    • pp.74-82
    • /
    • 2017
  • 유기단열재를 사용한 샌드위치패널(복합자재) 건축물 화재는 소화가 어려우며, 가연성 심재를 통한 빠른 화재 확산으로 화재 시 피해가 크다. 샌드위치패널은 양면이 불연재로 되어있고, 불연재 사이에 심재인 단열재로 이루어져 있다. 단열재는 유기단열재와 무기단열재가 사용되고 있으며, 유기단열재가 무기단열재에 비하여 약 80% 이상 사용되고 있다. 유기단열재는 무기단열재에 비하여 경제적인 장점이 있지만 화재에 취약하다는 단점을 가지고 있기 때문에 샌드위치패널 화재 시 일반화재에 비하여 피해가 크다. 가스유해성시험의 경우 복합자재의 심재 위험성을 측정하기 위해 패널에 지름 25 mm 크기 3개의 원형 천공을 하여 시험하지만 콘칼로리미터 시험은 샌드위치패널 형태 그대로 시험을 진행한다. 본 연구에서는 KS F ISO 5660-1 콘칼로리미터 시험에서 복합자재의 경우 불연재인 표면에 가열한 경우와 천공을 통한 심재 노출 시험 및 심재에 직접가열 시 발생하는 화재의 위험성을 측정하였다. 시험에 사용된 유기단열재는 일반 EPS와 난연 EPS를 사용하였으며, 시험체 구성은 샌드위치패널, 천공된 샌드위치 패널, 심재의 3가지 형태로 시험을 진행하였다. 본 연구의 목적은 콘칼로리미터 시험 시 복합자재 심재의 화재 위험성을 평가하는 방안을 제시하고자 하였다.