• 제목/요약/키워드: sampling frequency

검색결과 1,498건 처리시간 0.026초

하이브리드 업샘플링을 이용한 베이시안 초해상도 영상처리 (Super-Resolution Image Processing Algorithm Using Hybrid Up-sampling)

  • 박종현;강문기
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.294-302
    • /
    • 2008
  • In this paper, we present a new image up-sampling method which registers low resolution images to the high resolution grid when Bayesian super-resolution image processing is performed. The proposed up-sampling method interpolates high-resolution pixels using high-frequency data lying in all the low resolution images, instead of up-sampling each low resolution image separately. The interpolation is based on B-spline non-uniform re-sampling, adjusted for the super-resolution image processing. The experimental results demonstrate the effects when different up-sampling methods generally used such as zero-padding or bilinear interpolation are applied to the super-resolution image reconstruction. Then, we show that the proposed hybird up-sampling method generates high-resolution images more accurately than conventional methods with quantitative and qualitative assess measures.

국가지하수 관측소의 장기수위관측자료를 활용한 관측주기 결정 연구

  • 김규범;김정우;원종호;이명재;이진용;이강근
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.199-201
    • /
    • 2003
  • The monitoring effectiveness not only depends on the effectiveness of the network, but also the costs of the network. Generally the costs of the monitoring network are mainly on the equipment and personnel; the implementation and maintenance; the observation and sample connection; the sample analysis; and the data storage and processing. The cost of the monitoring network can be expressed as a function of monitoring frequency because the monitoring method can be an automatic or a manual measurement. To determine the sampling frequency of subsidiary groundwater monitoring stations, time series data of national groundwater monitoring stations were used. The proposed optimal sampling frequency for subsidiary groundwater monitoring station is about 7 to 20 days and the average frequency is about 2 weeks.

  • PDF

MRPID 제어기의 튜닝 방법연구 (A Study on the MRPID parameter tuning method)

  • 류현준
    • 전자공학회논문지SC
    • /
    • 제44권6호
    • /
    • pp.21-28
    • /
    • 2007
  • Mutiresolution proportional-integral-derivative(MRPID) 제어기는 웨이브렛 기반의 다해상도 응답을 이용해서 에러 신호에 포함되어 있는 잡음과 외란을 제거하는 필터 역할을 해준다. 다해상도 응답의 특징상 샘플링 주파수가 높을 경우 상대적으로 고주파성분이 남아있음으로 인해 응답속도가 떨어지는 대신에 오버슈트가 제거되고, 낮을 경우 신호 성분이 제거되므로 인해 응답속도가 향상되지만 오버슈트가 증가 되는 결과를 보였다. 본 논문에서는 proportional-integral-derivative(PID) 제어기와 MRPID 제어기의 응답을 이용한 샘플링 주파수를 설정하는 기법과, MRPID 제어기의 특성을 고려한 파라미터 설정기법을 제안한다. 모의실험을 통해서 제안된 기법의 타당성을 검증하였다.

A 1.2-V Wide-Band SC Filter for Wireless Communication Transceivers

  • Yang, Hui-Kwan;Cha, Sang-Hyun;Lee, Seung-Yun;Lee, Sang-Heon;Lim, Jin-Up;Choi, Joong-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제6권4호
    • /
    • pp.286-292
    • /
    • 2006
  • This paper presents the design of a low-voltage wide-band switched-capacitor (SC) filter for wireless communication receiver applications. The filter is the 5th-order Elliptic lowpass filter. With the clock frequency of 50MHz implying that an effective sampling frequency is 100MHz with double sampling scheme, the cut-off frequency of the filter is programmable to be 1.25MHz, 2.5MHz, 5MHz and 10MHz. For low-power systems powered by a single-cell battery, the SC filter was elaborately designed to operate at 1.2V power supply. Simulation result shows that the 3rd-order input intercept point (IIP3) can be up to 27dBm. The filter was fabricated in a $0.25-{\mu}m$ 1P5M standard CMOS technology and measured frequency responses show good agreement with the simulation ones. The current consumption is 34mA at a 1.2V power supply.

홍수 빈도 예측을 위한 통계학적 모형 (The Statistical Model for Predicting Flood Frequency)

  • 노재식;이길춘
    • 물과 미래
    • /
    • 제25권2호
    • /
    • pp.89-97
    • /
    • 1992
  • 본 연구는 한강유역내 수위표지점 중에서 댐에 의한 인위적 유량 조작을 받지 않는 자연하천유역에서의 지점들을 대상으로 홍수빈도예측을 위한 통계학적 모형의 적용성을 비교 검토하였고 그 결과 적용 가능한 것으로 입증하였다. 또한 홍수빈도모형에 의한 홍수추정량으로 부터모형의 통계학적 효용성을 검토한 결과, 단 기간 기록년수의 자료에서 유용한 부분기간치계열 방법에 의한 POT모형이 연최대치계열 방법에 의한 ANNMAX형보다 효과적임이 판명되었다.

  • PDF

광대역 주파수 합성기용 YTO 모듈 설계 및 제작 (Design and Fabrication of YTO Module for Wideband Frequency Synthesizer)

  • 채명호;홍성용
    • 한국전자파학회논문지
    • /
    • 제23권11호
    • /
    • pp.1280-1287
    • /
    • 2012
  • 3.2~6.5 GHz 광대역 특성을 갖는 YTO(YIG Tuned Oscillator) 모듈을 설계 및 제작하였다. 위상 잡음 특성을 개선하기 위해 샘플링 믹서를 이용한 offset PLL(Phase Locked Loop) 구조로 설계하였다. 이 방식은 샘플링 믹서, 위상 비교기, 루프 필터, 전류 드라이버 회로, YTO로 구성된다. 측정 결과, 4.5 GHz에서 위상 잡음은 수식으로 도출한 값과 유사한 10 kHz offset 주파수에서 -100 dBc/Hz를 얻었다. 제작된 YTO 모듈의 위상 잡음은 동작 주파수 대역에서 기존 PLL 구조에 비해 10 dB 이상 우수함을 확인하였다.

Sampling Jitter Effect on a Reconfigurable Digital IF Transceiver to WiMAX and HSDPA

  • Yu, Bong-Guk;Lee, Jae-Kwon;Kim, Jin-Up;Lim, Kyu-Tae
    • ETRI Journal
    • /
    • 제33권3호
    • /
    • pp.326-334
    • /
    • 2011
  • This paper outlines the time jitter effect of a sampling clock on a software-defined radio technology-based digital intermediate frequency (IF) transceiver for a mobile communication base station. The implemented digital IF transceiver is reconfigurable to high-speed data packet access (HSDPA) and three bandwidth profiles: 1.75 MHz, 3.5 MHz, and 7 MHz, each incorporating the IEEE 802.16d worldwide interoperability for microwave access (WiMAX) standard. This paper examines the relationship between the signal-to-noise ratio (SNR) characteristics of a digital IF transceiver with an under-sampling scheme and the sampling jitter effect on a multichannel orthogonal frequency-division multiplexing (OFDM) signal. The simulation and experimental results show that the SNR of the OFDM system with narrower band profiles is more susceptible to sampling clock jitter than systems with relatively wider band profiles. Further, for systems with a comparable bandwidth, HSDPA outperforms WiMAX, for example, a 5 dB error vector magnitude improvement at 15 picoseconds time jitter for a bandwidth of WiMAX 3.5 MHz profile.

EM Solver 의 주파수 응답 데이터를 이용한 RF 수동 소자의 등가회로 모델링에 관한 연구 (Equivalent Circuit Model of RF passive components based on its simulated frequency response data)

  • 오상배;고재형;한형석;김형석
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2007년도 학술대회
    • /
    • pp.27-30
    • /
    • 2007
  • This paper deals with an equivalent circuit model for RF passive components. Rational functions are obtained from the frequency responses of EM simulation by using Foster canonical partial fraction expressions. The Vector Fitting(VF) and the Adaptive Frequency Sampling(AFS) scheme are also implemented to obtain the rational functions. A passivity enforcement algorithm is applied to ensure the stability of the equivalent circuit model. In order to verify the schemes, S parameters of the equivalent circuit model is compared to those of EM simulation in case of the microstrip line structure with 3 slots in ground.

  • PDF

교류전력 불평형 보상장치용 모델예측기반 전류제어 연구 (A Study on a Current Control Based on Model Prediction for AC Electric Railway Inbalance Compensation Device)

  • 이정현;조종민;신창훈;이태훈;차한주
    • 전력전자학회논문지
    • /
    • 제25권6호
    • /
    • pp.490-495
    • /
    • 2020
  • The power loss of large-capacity systems using single-phase inverters has attracted considerable attention. In this study, optimal switching sequence model prediction control at a low switching frequency is proposed to reduce the power loss in a high-power inverter system, and a compensation method that can be utilized for model prediction control is developed to reduce errors in accordance with sampling values. When a three-level, single-phase inverter using a switching frequency of 600 Hz and a sampling frequency of 12 kHz is adopted, the power factor is improved from 0.95 to 0.99 through 3 kW active power control. The performance of the controller is also verified.

강우시 채수빈도가 논 오염부하량 산정에 미치는 영향 (Effect of Sampling Frequency During Storm Period on Estimation of Pollutant Load from Paddy Field)

  • 한국헌;김진호;이종식;이정택;조재영;윤광식
    • 한국환경농학회지
    • /
    • 제24권1호
    • /
    • pp.17-23
    • /
    • 2005
  • 한정된 수질자료를 이용 오염부하 산정시 집중적으로 많은 샘플을 채취한 경우에 비해 어느 정도 차이를 갖는지를 규명하는 것은 모니터링에 따른 오염부하량 산정결과의 신뢰범위 파악뿐만 아니라 경제적인 수질 샘플 채수빈도 수립에 곡 필요할 것으로 사료된다. 그 결과를 요약하면 다음과 같다. 논에서의 강-은유출시 채수 빈도가 오염부하 산정에 미치는 영향을 파악하기 위해 9개의 강우사상에 대해 2시간 간격으로 연속 수질샘플을 실시하여 분석한 결과 전체적으로 강우-유출과정 중 T-N, T-P, SS 농도는 시간별로 증 감변동을 하였으나 유량과의 상관성은 나타나지 않았다. 수질샘플 횟수에 의한 영향은 강우-유출과정 중 5회 정도 샘플을 실시하면 많은 수의 샘플을 채수한 경우에 비해 T-N ${\pm}15.2%$, T-P는 $-20.0{\sim}26.2%$, SS는 $-28.6{\sim}35.7%$ 범위안에서 오염부하를 추정할 수 있는 것으로 나타났으며, 차이범위가 ${\pm}10%$ 내에 들어가기 위한 샘플수는 일주기 조사시 T-N, T-P의 경우는 6회, SS의 경우는 단기유출시는 4회 정도 실시하면 되고, 장기 유출시에는 11회 정도 실시하면 되는 것으로 조사되었다. 유량-유하부하량 관계식에서 ${\pm}10%$내의 차이를 보일 샘플횟수는 T-N의 경우는 6회 이상, T-P와 SS는 9회 이상 정도 실시하면 되는 것으로 조사되었다.